Catálogo Cable Génesis

download Catálogo Cable Génesis

of 96

Transcript of Catálogo Cable Génesis

  • 8/16/2019 Catálogo Cable Génesis

    1/96

    Honeywell Cable Catalog

    Genesis SeriesLow Voltage Cable

    SECURITY, FIRE, HOME THEATER, SOUND,

    CCTV, CATV, VOICE AND DATA AND

    THERMOSTAT WIRE

  • 8/16/2019 Catálogo Cable Génesis

    2/96

    Welcome

    Dear Industry Professional,

    Welcome to Honeywell’s Genesis Series Cable Catalog. Throughout this catalog you will find an

    outstanding selection of low voltage cables, interconnects and accessories.

    Honeywell’s cable line is continuously growing. At the same time, we focus on our promise of 

    quality, technology and commitment explained in the pages to follow. We are always working on

    improving existing products while introducing new ones that can help you grow your business.

    Recent developments include:

    Improved Packaging and Labeling:

    • We now provide color-coded boxes and wrap-around labels for our cable products

    which aid in the identification of the cable

    • To ease the installation process, we have improved our cable legends which now

    include room and zone markings as well as our countdown footage marking system

    New A/V Cables, Interconnects and Accessories:

    • Our new 7000 Series HDMI Cables include Eye Pattern test results in the packaging

    • A complete new line of interconnects has been introduced including

    , RCA Audio Cables, and RGBHV Video Cables

    • The HDMI Restorer, Tester and Diagnostic Unit are just a few of the new accessories we

    now have to offer

     All of our products, helpful resources and a download of this complete catalog are available on

    our website www.honeywellcable.com. We hope you enjoy exploring all we have to offer, and

    we thank you for your support.

    TM

  • 8/16/2019 Catálogo Cable Génesis

    3/961

    Honeywell’s Genesis Series Cables are produced in

    the newest wire and cable plant in North America,

    utilizing state-of-the-art technology and production

    equipment. Genesis Series Cables are available for 

    a full range of applications.

     Applications:

     Alarm & Security

     Access Control

    Telephone/FaxHigh Speed Internet

    Environmental Control

    Home Theater 

    Whole House Audio

    CATV/CCTV 

    Satellite

    Computer Networking

    and More!

    Security & Control Cables . . . . . . . . . . . . . . . . . . . 9

    Irrigation Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Thermostat Cables . . . . . . . . . . . . . . . . . . . . . . . . 29

    Fire Alarm Cables . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Genesis Crystal Series Cables. . . . . . . . . . . . . . . 39

    Home Theater Cables. . . . . . . . . . . . . . . . . . . . . . 55

    Multimedia Cables . . . . . . . . . . . . . . . . . . . . . . . . 61

    Networking Cables . . . . . . . . . . . . . . . . . . . . . . . . 65

    Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

    Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Genesis SeriesCable Products

  • 8/16/2019 Catálogo Cable Génesis

    4/962 www.honeywellcable.com

    Introduction to Genesis Series Cable. . . . . . . . . . . . . . . 3-7

    Security & Control / Power Limited Circuit Cables - Article 725

    Power Limited Circuit Cables

    Type CM, CL2, CMR, CL2R, CMP, CL2P, FT4, FT6

    CM, CL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-16

    CMR, CL2R, FT4 (RISER). . . . . . . . . . . . . . . . . . . . . . . 17-20

    CMP, CL2P, FT6 (PLENUM) . . . . . . . . . . . . . . . . . . . . . 21-24

    Home Automation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

     Access Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    Irrigation, Tracer and Lighting Cable  - Article 725

    Irrigation, Tracer and lighting Cable. . . . . . . . . . . . . . . . . 27

    Underground Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Thermostat Cables - Article 725

    Thermostat Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Thermostat Cable General Purpose. . . . . . . . . . . . . . . . . 30

    Thermostat Cable Plenum . . . . . . . . . . . . . . . . . . . . . . . . 30

    Fire Alarm / Power Limited Circuit Cables - Article 760

    Fire Power Limited Circuit Cable

    Type FPL, FPLR, FPLP, FPL Direct Burial

    FPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33

    FPLR (RISER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35

    FPLP (PLENUM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36

    LL5 (LOCAL LAW FIVE). . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Crystal Series Cables

    RGB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

     Audio Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

    Serial Digital. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

    HDMI Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43-47

     Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-52

     Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53-54

    Home Theater Cables - Article 725

    Heavy Duty Zip Cable, Clear, Oxygen-free, Zipcord   . . . . . 56

    Home Theater Sound Cable . . . . . . . . . . . . . . . . . . 57-58

     Audacious Sound Cable, Oxygen-Free . . . . . . . . . . . . 59

    Crystal Series Professional Audio and Home Theater . . . 59

    Multimedia Cables - Article 725

    Bundled Multimedia . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

    ProFusion™ Unjacketed Multimedia . . . . . . . . . . . . . . 62

    Dual Zip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

    Networking Cables - Article 800

    Communication Circuits, Voice & Data Cable, Type CM,

    CMR, CMP, Video Surveillance Systems . . . . . . . . 66-70

    CATV Coaxial Cables - Article 820

    CATV (Hyperband Premium Broadband) . . . . . . . . 72-74

    Serial Digital Coax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    CCTV Coaxial Cables - Article 725

    CCTV (Baseband). . . . . . . . . . . . . . . . . . . . . . . . . . . 76-78

    UTP CCTV Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

    Underground Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

    Technical Data

    National Electric Code. . . . . . . . . . . . . . . . . . . . . . . . . . 81

    Cable Substitution Hierarchy Chart . . . . . . . . . . . . . . . 82

    Conductor Color Code Charts. . . . . . . . . . . . . . . . . 83-84

     Voice and Data Cables (Warranty Information) . . . . . . 85

     ANSI / TIA / EIA Telecommunications Cable Standard . . . . 8 6

    Genesis Semi-Extruded Jacket . . . . . . . . . . . . . . . . . . 87

     Voltage Drop and Audio Cable Charts . . . . . . . . . . . . . 88

    Part Number Descriptions. . . . . . . . . . . . . . . . . . . . . . . 89

    Index By Genesis Part Number 

    Index by Genesis Part Number . . . . . . . . . . . . . . . . 91-92

  • 8/16/2019 Catálogo Cable Génesis

    5/963

    Genesis Series Low Voltage Cables are produced

    with innovative equipment and technology in

    a state-of-the-art facility. This leading edge

    production facility enables Honeywell to produce

    the highest quality Security, Fire, Sound, Video,

     Voice and Data wire and cable in the most focused

    facility in North America.

    In addition to operating the premier manufacturing

    facility in our industry, Genesis Series Cables are

    produced by an experienced team. The management

    team has spent their entire career in the wire and

    cable industry, representing over 80 years of wire

    and cable experience. Furthermore, virtually all

    supervisors and line operators boast similar 

    longevity in the wire business, exhibiting an

    uncompromising dedication to their craft.

    Genesis Series Cable

  • 8/16/2019 Catálogo Cable Génesis

    6/964 www.honeywellcable.com

    Quality...unsurpassed equipment, the most

    experienced people and the finest raw materials,

    combine to create the highest quality products in

    the industry. We are so confident in Genesis Series

    products that we offer the most comprehensive

    guarantee in the industry. If any Genesis Series

    product fails to perform to our specification, during

    the life of any original installation, we will replace

    the cable — three spools or boxes for one. No one

    else in the industry makes that guarantee.

    Technology...Genesis Series Cables are the highest

    quality and most cost effective cables in our 

    industry. By understanding the needs of our 

    customers, Genesis Series Cables deliver real

    value. All of our products exceed the industry

    standards of Underwriters Laboratories, ETL,

    EIA/TIA, the Canadian Standards Association

    (where applicable), the National Electric Code and

    the NFPA.

    Commitment...Honeywell has brought together 

    every conceivable resource to ensure that Genesis

    Series Low Voltage Cables deliver ultimate value to

    our customers. This means the highest standards

    of service, quality and efficiency, all backed by our 

    limited lifetime warranty. Our commitment goes

    beyond our products, extending to our distributors

    and our loyal customers.

  • 8/16/2019 Catálogo Cable Génesis

    7/965

    New ImprovedPackaging & Labeling

    Genesis Series Cable now has color-coded

    boxes and wrap-around labels that offer the

    following benefits:

    • Color-coded boxes for easy identification of

    cable type

    • Larger, descriptions for easier identification of

    specific cable constructions

    • Visible Plenum/Riser/General Purpose

    identification to help avoid costly accidental

    shipments of improper rated cable

    • New application section on label for additional

    help with identification of the proper cable

    New Cable Legends, Now with Countdown™

    Footage Markings

    Honeywell Genesis Series Cable has improved its

    cable legends with the addition of room and zone

    markings as well as our countdown footage

    marking system.

    • Countdown™ footage markings allow

    installers to continuously track the amount

    of cable they have remaining

    • Convenient new room and zone markings give

    installers flexibility by allowing them to easily

    mark and identify the cable

    • Minimizes any testing that is required to

    confirm or identify a non-labeled cable

     AUDIO/VIDEO, CATV-MATV, SATELLITE, RADIO FREQUENCY

     AND COMPUTER/DATA TRANSMISSIONSCODE GENERAL PURPOSEUL, CATV, CL2

    NEW LABEL SYSTEMlor Code(Black)

    Large Description   Applications

    Cable TypeGeneral Use

    Footage Remaining

  • 8/16/2019 Catálogo Cable Génesis

    8/966 www.honeywellcable.com

    Introducing Genesis Series Profusion™ bundled

    cables; the simplest, most cost effective solution

    for bundled cable applications. This new bundled

    cable technology eliminates the need for an outer 

     jacket. Individual cables are held together by a

    revolutionary tight, continuous twist scheme.

    The Profusion twist scheme holds the cables

    together without any binder tapes or adhesive

    materials. Our twisting method prevents any

    deterioration of the original cable’s performance.

    Profusion’s unique design lets installers separate

    the individual components effortlessly while

    reducing cold weather cracking and flexibility

    problems. These cables can support voice, data,

    video and other options.

    • Cables are held together by a revolutionary

    twisting method

    • Easy installation; just tape the end and pull

    • Individual cables effortlessly detach,

    unlike other jacketless bundled constructions

    • Lighter, more flexible and has a smaller over-all

    diameter than other bundled constructions

    • Cables are performance tested after bundling

    • Jacketless design saves valuable time for the

    installation professional, eliminating the need

    to remove an outer jacket

    • Eliminates cold weather cracking problems

    • No degradation of performance

    • Multiple constructions available

    • UL/ETL listed and tested

    • 100% Guaranteed

    Profusion Cables

  • 8/16/2019 Catálogo Cable Génesis

    9/967

    Future Proof Your Installations withCategory 6

    Why Install Category 6 In Your Home?

    • Cat 6 bandwidth is 2.5 times that of Cat 5e

    • Cat 6 has 40% less signal loss than Cat 5e

    • Cat 6 has 100 times lower signal to noise ratio

    than Cat 5e

    • Cat 6 is built to support 10 times faster speeds

    • Cat 5e can only transport compressed

    HDTV signals

    • Cat 6 can transport uncompressed HDTV 

    signals running at 1.2 GHz!

    • As applications with digital and data rates

    increase, Cat 6 will be able to handle them

    • Tests of standard Cat 6 have verified that it

    can reliably transport 10 GHz data over 55

    meters (180 feet)

    • TIA-570-B Residential Infrastructure

    Telecommunications Standard recommends

    that Cat 6 be installed in residential applications

    • Category 6 will “future-proof” a home for 

    its lifetime!

  • 8/16/2019 Catálogo Cable Génesis

    10/96

    pixel perfect

    For additional information, please call  1-800-467-5875, or visit  www.honeywell.com/security

    © 2007 Honeywell International Inc. All rights reserved.

    TV the Way it Was Meant to Be Seen

    Everyone knows that a crisp, clear television picture can envelop

    a viewer and heighten the overall home theater experience.

    Thanks to Honeywell’s new HDMI Restorer and Diagnostics Unit

    with ™ Technology, your customers can view TV the

    way it’s meant to be seen…in brilliant, eye-popping detail!

    It solves the most common problems today’s installers face, including

    pixel drop out, audio clipping—even total signal loss. Full, 1080p pristine HD video and audio can

    be delivered up to 30 meters. What’s more, upstream and downstream problems with HDMI and

    HDCP compliance can even be diagnosed for quick and easy troubleshooting.

    Honeywell’s HDMI solutions. It’s picture-perfect thinking from a name you can trust.

  • 8/16/2019 Catálogo Cable Génesis

    11/969

    Our multi-conductor cables are manufactured in

    a wide variety of gage sizes, shielding

    configurations and jacketing materials including

    plenum, riser and general purpose. Applications

    for these cables include control cables (Lutron

    Systems & Crestron Systems), alarms,

    intercoms, speakers and other low voltage

    circuits that are power limited.

    Features:

    • Countdown

    • New Labeling

    System on Boxes

    • Color Coded Boxes

    • Zone and Room

    Markings

     Article 725/800*

    Class 1, Class 2, and Class 3 remote-control,

    signaling and power limited circuits that are not

    an integral part of a device or appliance.

    The scope of this article may include systems

    such as burglar alarm, access control, sound,

    nurse call, intercom circuits, some computer 

    network systems, some control circuits for lighting dimmer systems, and some low voltage

    control circuits that originate from listed

    computer equipment.

    General Purpose Cable:  Type CM, CL2, CMR,

    CL2R, CMP, CL2P.  Cables may be dual rated

    CM/CL2, CMR/CL2R, CMP/CL2P.

    *See Article 800 for more information.

    Security & Control Cables

  • 8/16/2019 Catálogo Cable Génesis

    12/96

        A    R    T    I    C    L    E    7

        2    5

    10 www.honeywellcable.com

    SECURITY & CONTROL CABLES

    Control Cables for Crestron Systems

    CONTROL CABLES FOR CRESTRON SYSTEMS

    COMPARABLE TO DESCRIPTION JACKET COLOR NOM. O.D. AVG. WT. PER MFT PART#

    CRESCAT-NP

    Control Cable 22/1pr Low Cap + 18/2 Teal/Red Stripe .485 78 (LBS)   1270

    Data Cable CAT 5e 350 MHz

    CRESCAT-D-NP

    Control Cable 22/1pr Low Cap + 18/2 Teal/Black Stripe .530 105 (LBS)   1278

    Data Cable 2 X CAT 5e 350 MHzCRESCAT-Q-NP

    Control Cable 22/1pr Low Cap + 18/2  Teal/White Stripe .680 145 (LBS)   1279Data Cable 4 X CAT 5e 350 MHzCRESCAT-DC-NP

    Control Cable 22/1pr Low Cap + 18/2

    Data Cable 2 X CAT 5e 350 MHz Teal/Orange Stripe .800 194 (LBS)   1272

    Coax Cable 2 X RG6 BC Quad Shielded

    DESIGNED FOR USE WITH CRESTRON TOUCH PANELS, KEYPADS, EXPANSION MODULES, TUNERS AND MORE.

    COMPARABLE TO DESCRIPTION JACKET COLOR NOM. O.D. AVG. WT. PER MFT PART#

    CRESNET-NP

    Control Cable 22/1pr Low Cap + 18/2 Power Blue/Yellow Stripe .280 33 (LBS)   1244

    DESIGNED TO PROVIDE A SIGNAL-CABLE SOLUTION FOR WIRING OF MEDIA SYSTEMS.COMPARABLE TO DESCRIPTION JACKET COLOR NOM. O.D. AVG. WT. PER MFT PART#

    CRESCAT-IM-P

    Control Cable 24/4pr Category 5e 100 MHz CMP Blue .200 27 (LBS)   5088

    Dimmer Control Cable

    Control Cable 22/1pr Gray .120 13 (LBS)   1202

    Honeywell Genesis Series Cable offers specialized control cables for Crestron Systems. These bundled cables facilitate fast and easy wiring for Crestron AV distribution switchers,room solution boxes, intercoms and touch panels. The constructions with RG6 cable allowfor distribution of CATV, satellite, broadband or modulated video.

  • 8/16/2019 Catálogo Cable Génesis

    13/9611

    Echelon® Lonworks®  Approved WireEchelon supplies infrastructure hardware and software to the rapidly growing networkingmarket. Echelon Lonworks systems are installed in buildings, factories, utilities and housesallowing users to remotely connect, monitor and diagnose intelligent devices. EchelonLonworks solutions enable multiple key building systems used for security, lighting, elevatorand HVAC to be integrated into a single smart building.

    HONEYWELL GENESIS SERIES – LEVEL 4 CABLES APPROVED FOR ECHELON LONWORKS AWG CONDUCTORS LISTING PART #

    22 1 Pair Stranded Bare Copper, Unshielded CM, CL2   1061

    22 2 Pair Stranded Bare Copper, Unshielded CM, CL2   1062

    22 1 Pair Stranded Bare Copper, Shielded CM, CL2   1063

    22 2 Pair Stranded Bare Copper, Overall Shield CM, CL2   1064

    22 1 Pair Stranded Bare Copper, Unshielded CMP, CL2P   3252

    22 2 Pair Stranded Bare Copper, Unshielded CMP, CL2P   3253

    22 1 Pair Stranded Bare Copper, Shielded CMP, CL2P   3254

    22 2 Pair Stranded Bare Copper, Overall Shield CMP, CL2P   3255

    Echelon and Lonworks are trademarks of Echelon Corporation registered in the United States and Other Countries.

    Control Cables for Lutron

    Honeywell Genesis Series Cable offers specialized lighting control cables for Lutronsystems. These cables are specifically designed to meet the Lutron cable standards.

    Honeywell's Genesis Series Cable provides a full range of low voltage cables for security,fire, sound, video, home theater, structured cabling, voice & data and other low voltagecable applications.

    CONTROL CABLES FOR LUTRON

    JACKETSTYLE CONSTRUCTION COLOR SHIELD LISTING PART#

    HomeWorks 18/2 STR 16/30 BC Gray Aluminum Mylar TC Drain CM   1214

    Dimmer & Switch

    HomeWorks 18/4 STR 16/30 BC Gray Aluminum Mylar TC Drain CM   1215

    Dimmer & Switch

     Vareo Dimmer & Switch 22/2 STR 7/30 BC Gray Aluminum Mylar TC Drain CM   1202

    Keypad Data/Grafik 22/1pr Low Cap Blue/Yellow 22/1pr Aluminum Mylar TC Drain CM   1244Eye 3000 Data 18/2 Power Stripe

    Grafik Eye 22/1pr Low Cap DataBlue 22/1pr Aluminum Mylar TC Drain CM   1260

    4000/6000 12/2 Power 18/1 Ground

    Sovoia 18/4 BCBlue /Red

      Aluminum Mylar

    Shades 16/2 BCStripe

      None CM   1287

    18/1 BC None

    HomeWorks18/2 STR 16/30 BC White Aluminum Mylar TC Drain CMP   3214

    Dimmer & Switch

    HomeWorks18/4 STR 16/30 BC White Aluminum Mylar TC Drain CMP   3215

    Dimmer & Switch

     Vareo Dimmer & Switch 22/2 STR 7/30 BC White Aluminum Mylar TC Drain CMP   3202

    Control Cables for Echelon® Lonworks®

  • 8/16/2019 Catálogo Cable Génesis

    14/96

        A    R    T    I    C    L    E    7

        2    5

    12 www.honeywellcable.com

    Jacketed Cables Unshielded

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available In 500 foot or 1000 foot. Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Flexible Polyvinyl-ChlorideJackets. Standard Jacket Color: Gray. Conductor Color Code, Chart 1(up to 12 conductors). Color Code Chart 2 (13 conductors and over).

    JACKETED CABLES UNSHIELDED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    24 4 SOL. .105 14 CM, CL2 10 (LBS)   1140+

    22 2 SOL. .104 16 CM, CL2 8 (LBS.)   1101*

    22 2 STR. .114 16 CM, CL2 9 (LBS.)   1102*

    22 4 SOL. .116 16 CM, CL2 14 (LBS.)   1103*#

    22 4 STR. .133 16 CM, CL2 15 (LBS.)   1104*

    22 5 STR. .145 16 CM, CL2 19 (LBS.)   1105*

    22 6 SOL. .140 16 CM, CL2 19 (LBS.)   1106*

    22 6 STR. .158 16 CM, CL2 21 (LBS.)   1107*

    22 8 SOL. .152 16 CM, CL2 25 (LBS.)   1108

    22 8 STR. .172 16 CM, CL2 28 (LBS.)   1109

    22 10 SOL. .174 16 CM, CL2 29 (LBS.)   1110

    22 10 STR. .200 16 CM, CL2 33 (LBS.)   1111

    22 12 SOL. .182 16 CM, CL2 35 (LBS.)   1112

    22 12 STR. .204 16 CM, CL2 40 (LBS.)   1113

    20 4 STR. .155 17 CM, CL2 22 (LBS.)   1117

    18 2 STR. .148 18 CM, CL2 18 (LBS.)   1118

    18 2 SOL. .136 18 CM, CL2 16 (LBS.)   113818 3 STR. .159 18 CM, CL2 24 (LBS.)   1130

    18 4 STR. .172 18 CM, CL2 30 (LBS.)   1119

    18 6 STR. .206 18 CM, CL2 44 (LBS.)   1120+

    18 8 STR. .225 18 CM, CL2 55 (LBS.)   1121+

    18 10 STR. .270 18 CM, CL2 70 (LBS.)   1122+

    18 12 STR. .277 18 CM, CL2 80 (LBS.)   1123+

    16 2 STR. .172 19 CM, CL2 24 (LBS.)   1125

    16 4 STR. .202 19 CM, CL2 44 (LBS.)   1126+

    14 1 SOLID INSULATED GROUND WIRE 18 (LBS.)   1131+

    14 2 STR. .208 21 CM, CL2 37 (LBS.)   1127+

    12 2 STR. .264 21 CM, CL2 55 (LBS.)   1129+

    *Not Twisted

    #Color Code = Black, Red, Green, Yellow

    +Spools Only

    MFT=1000 FT.

  • 8/16/2019 Catálogo Cable Génesis

    15/9613

    Jacketed Cables Shielded (Overall Shield)

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Polypropylene Insulation, Aluminum/MylarShield, with Drain Wire, Flexible Polyvinyl-Chloride Jackets. StandardJacket Color: Gray. Conductor Color Code Chart 1 (up to 12 conductors).Color Code Chart 2 (13 conductors and over).

    JACKETED CABLES SHIELDED, (OVERALL SHIELD) 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 STR. .120 33 CM, CL2 13 (LBS.)   1202

    22 4 STR. .139 33 CM, CL2 18 (LBS.)   1204

    22 6 STR. .166 33 CM, CL2 25 (LBS.)   1206

    22 8 STR. .174 33 CM, CL2 30 (LBS.)   1207

    22 10 STR. .210 33 CM, CL2 36 (LBS.)   1208

    22 12 STR. .210 33 CM, CL2 42 (LBS.)   1209

    20 2 STR. .138 37 CM, CL2 16 (LBS.)   1212

    20 3 STR. .144 37 CM, CL2 21 (LBS.)   1227

    20 4 STR. .159 37 CM, CL2 24 (LBS.)   1213

    18 2 STR. .154 43 CM, CL2 20 (LBS.)   1214

    18 3 STR. .161 41 CM, CL2 27 (LBS.)   1228

    18 4 STR. .178 43 CM, CL2 32 (LBS.)   1215

    18 6 STR. .210 43 CM, CL2 45 (LBS.)   1216

    18 8 STR. .230 43 CM, CL2 59 (LBS.)   1217 +

    18 10 STR. .270 43 CM, CL2 63 (LBS.)   1218 +

    18 12 STR. .283 43 CM, CL2 86 (LBS.)   1219 +18 15 STR. .307 43 CM, CL2 104 (LBS.)   1220 +

    16 2 STR. .178 43 CM, CL2 32 (LBS.)   1221

    16 3 STR. .184 43 CM, CL2 41 (LBS.)   1229

    16 4 STR. .202 46 CM, CL2 44 (LBS.)   1222 +

    14 2 STR. .214 46 CM, CL2 45 (LBS.)   1223 +

    14 3 STR. .222 46 CM, CL2 60 (LBS.)   1230

    +Spools Only

    MFT=1000 FT.

  • 8/16/2019 Catálogo Cable Génesis

    16/96

        A    R    T    I    C    L    E    7

        2    5

    14 www.honeywellcable.com

    Multi-Pair Unshielded

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Conductors arranged inpairs, Flexible Polyvinyl-Chloride Jackets. Standard Jacket Color: Gray.Conductor Color Code Chart 3.

    MULTI-PAIR UNSHIELDED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .160 16 CM, CL2 15 (LBS.)   1248**

    22 2 STR. .178 16 CM, CL2 18 (LBS.)   1234

    22 3 SOL. .172 16 CM, CL2 19 (LBS.)   1235

    22 6 SOL. .226 16 CM, CL2 36 (LBS.)   1238

    18 2 STR. .240 17 CM, CL2 40 (LBS.)   124518 3 STR. .260 17 CM, CL2 47 (LBS.)   1246

    18 4 STR. .290 17 CM, CL2 59 (LBS.)   1247+

    *1 Pair Shielded 1 Pair Unshielded

    **Color code=Red/Green, Black/Yellow

    +Spools Only

    MFT=1000 FT.

  • 8/16/2019 Catálogo Cable Génesis

    17/9615

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Polypropylene Insulation, Conductors arearranged in pairs; Aluminum/Mylar Shield applied overall each assembledpair, with Drain Wire for each pair, Flexible Polyvinyl-Chloride Jackets.Standard Jacket Color: Gray. Conductor Color Code Chart 3.

    MULTI-PAIR SHIELDED (EACH PAIR SHIELDED) 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .170 33 CM, CL2 22 (LBS.)   1263

    22 2 STR. .192 33 CM, CL2 23 (LBS.)   1264

    22 3 STR. .197 33 CM, CL2 31 (LBS.)   1266

    18 2 STR. .252 45 CM, CL2 41 (LBS.)   1273

    18 3 STR. .268 45 CM, CL2 56 (LBS.)   1274

    18 4 STR. .300 45 CM, CL2 72 (LBS.)   1275+

    +Spools Only

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with for all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Aluminum/Mylar Shieldwith Drain Wire, Flexible Polyvinyl-Chloride Jackets. Standard Jacket

    MULTI-PAIR SHIELDED (OVERALL SHIELD) 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .165 33 CM, CL2 19 (LBS.)   1280

    22 3 SOL. .178 33 CM, CL2 26 (LBS.)   1282

    18 2 STR. .248 40 CM, CL2 36 (LBS.)   1289

    18 3 STR. .265 40 CM, CL2 51 (LBS.)   1290+

    18 4 STR. .295 40 CM, CL2 64 (LBS.)   1291+

    +Spools Only

    Multi-Pair Shielded (Each Pair Shielded)

    Multi-Pair Shielded (Overall Shield)

  • 8/16/2019 Catálogo Cable Génesis

    18/96

        A    R    T    I    C    L    E    7

        2    5

    16 www.honeywellcable.com

    Unjacketed Twisted Cables

    Zipcord

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, One Conductor Ribbed for Polarity, FlexiblePolyvinyl-Chloride Jackets. Standard Colors: White, Brown, or Clear.

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risersand Plenums.

    Features:   Available In 500 foot or 1000 foot Spools or Reel-in-a-Box withDispensing System.

    Construction:   One TC (Tinned Copper) Conductor, Ribbed for Polarity; and oneSmooth BC (Bare Copper Conductor); PVC Insulation.Colors Available: Brown/Brown, White/White.

    UNJACKETED TWISTED CABLES 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 STR. .147 14 CM, CL2 10 (LBS.)   1051+

    20 2 STR. .165 16 CM, CL2 15 (LBS.)   1052+

    18 2 STR. .183 17 CM, CL2 20 (LBS.)   1053+

    + Spools Only

    • Consult factory for availability.

    ZIPCORD 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    24 2 STR .068 x .145 12 CL2, C(UL), CMG 9 (LBS.)   1001•

    22 2 STR .074 x .164 15 CL2, C(UL), CMG 9 (LBS.)   1002

    20 2 STR .083 x .180 18 CL2, C(UL), CMG 17 (LBS.)   1003•

    18 2 STR .090 x .190 20 CL2, C(UL), CMG 18 (LBS.)   1004

    16 2 STR .100 x .200 22 CL2, C(UL), CMG 24 (LBS.)   1005

    •Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    19/9617

    Jacketed Cables Unshielded, Riser Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms,TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits, except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Flexible Polyvinyl-ChlorideJackets. Standard Jacket Color: Gray. Conductor Color Code Chart 1(up to 12 conductors). Color Code Chart 2 (13 conductor and over).

    JACKETED CABLES UNSHIELDED, RISER RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .106 16 C(UL), FT4, CMR, CL2R 9 (LBS.)   2101*

    22 2 STR. .116 16 C(UL), FT4, CMR, CL2R 11 (LBS.)   2102*

    22 4 SOL. .120 16 C(UL), FT4, CMR, CL2R 14 (LBS.)   2103*#

    22 4 STR. .135 16 C(UL), FT4, CMR, CL2R 16 (LBS.)   2104*

    22 5 STR. .145 16 C(UL), FT4, CMR, CL2R 18 (LBS.)   2105*22 6 STR. .158 16 C(UL), FT4, CMR, CL2R 21 (LBS.)   2106*

    22 8 STR. .174 16 C(UL), FT4, CMR, CL2R 28 (LBS.)   2107

    22 10 STR. .202 16 C(UL), FT4, CMR, CL2R 35 (LBS.)   2108

    22 12 STR. .208 16 C(UL), FT4, CMR, CL2R 37 (LBS.)   2109

    22 15 STR. .232 16 C(UL), FT4, CMR, CL2R 44 (LBS.)   2110+•

    20 2 STR. .136 16 C(UL), FT4, CMR, CL2R 14 (LBS.)   2112

    20 4 STR. .157 16 C(UL), FT4, CMR, CL2R 22 (LBS.)   2113

    18 2 STR. .150 18 C(UL), FT4, CMR, CL2R 18 (LBS.)   2114

    18 4 STR. .174 18 C(UL), FT4, CMR, CL2R 30 (LBS.)   2115

    18 6 STR. .208 18 C(UL), FT4, CMR, CL2R 42 (LBS.)   2116*

    18 8 STR. .228 18 C(UL), FT4, CMR, CL2R 58 (LBS.)   2117+•

    18 10 STR. .268 18 C(UL), FT4, CMR, CL2R 71 (LBS.)   2118+•18 12 STR. .276 18 C(UL), FT4, CMR, CL2R 84 (LBS.)   2119+•

    18 15 STR. .305 18 C(UL), FT4, CMR, CL2R 108 (LBS.)   2120+•

    16 2 STR. .176 19 C(UL), FT4, CMR, CL2R 27 (LBS.)   2121

    16 4 STR. .205 19 C(UL), FT4, CMR, CL2R 46 (LBS.)   2122+

    14 2 STR. .212 21 C(UL), FT4, CMR, CL2R 38 (LBS.)   2123+

    14 4 STR. .248 21 C(UL), FT4, CMR, CL2R 70 (LBS.)   2124+

    12 2 STR. .256 21 C(UL), FT4, CMR, CL2R 58 (LBS.)   2125+

    *Not Twisted

    #Black, Red, Yellow, Green

    +Spools Only

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    20/96

        A    R    T    I    C    L    E    7

        2    5

    18 www.honeywellcable.com

    Jacketed Cables Overall Shield, Riser Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Polypropylene Insulation, Aluminum/MylarShield, with Drain, Flexible Polyvinyl-Chloride Jackets. Standard JacketColor: Gray. Conductor Color Code Chart 1 (up to 12 conductors).Color Code Chart 2 (13 conductors and over).

    JACKETED CABLES SHIELDED (OVERALL SHIELD) RISER RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .112 33 C(UL), FT4, CMR, CL2R 11 (LBS.)   2201

    22 2 STR. .120 33 C(UL), FT4, CMR, CL2R 12 (LBS.)   2202

    22 4 SOL. .127 33 C(UL), FT4, CMR, CL2R 15 (LBS.)   2203

    22 4 STR. .141 33 C(UL), FT4, CMR, CL2R 19 (LBS.)   2204

    22 6 STR. .162 33 C(UL), FT4, CMR, CL2R 25 (LBS.)   220622 8 STR. .175 33 C(UL), FT4, CMR, CL2R 31 (LBS.)   2207

    22 10 STR. .204 33 C(UL), FT4, CMR, CL2R 37 (LBS.)   2208

    22 12 STR. .210 33 C(UL), FT4, CMR, CL2R 41 (LBS.)   2209

    22 15 STR. .234 33 C(UL), FT4, CMR, CL2R 106 (LBS.)   2210+•

    20 2 STR. .142 37 C(UL), FT4, CMR, CL2R 17 (LBS.)   2212

    20 4 STR. .163 37 C(UL), FT4, CMR, CL2R 26 (LBS.)   2213

    18 2 STR. .154 41 C(UL), FT4, CMR, CL2R 21 (LBS.)   2214

    18 4 STR. .180 41 C(UL), FT4, CMR, CL2R 34 (LBS.)   2215

    18 6 STR. .214 41 C(UL), FT4, CMR, CL2R 46 (LBS.)   2216

    18 8 STR. .232 41 C(UL), FT4, CMR, CL2R 59 (LBS.)   2217+

    18 10 STR. .268 41 C(UL), FT4, CMR, CL2R 72 (LBS.)   2218+

    18 12 STR. .281 41 C(UL), FT4, CMR, CL2R 85 (LBS.)   2219+

    18 15 STR. .312 41 C(UL), FT4, CMR, CL2R 103 (LBS.)   2220+•

    16 2 STR. .180 43 C(UL), FT4, CMR, CL2R 32 (LBS.)   2221

    16 4 STR. .209 43 C(UL), FT4, CMR, CL2R 51 (LBS.)   2222+

    14 2 STR. .216 46 C(UL), FT4, CMR, CL2R 46 (LBS.)   2223+

    14 4 STR. .252 46 C(UL), FT4, CMR, CL2R 76 (LBS.)   2224+

    12 2 STR. .262 46 C(UL), FT4, CMR, CL2R 64 (LBS.)   2225+

    +Spools Only

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    21/9619

    Multi-Pair Unshielded, Riser Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStation, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits, except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Conductors are arrangedin pairs, Flexible Polyvinyl-Chloride Jacket. Standard Jacket Color: Gray.Conductor Color Code Chart 3.

    MULTI-PAIR UNSHIELDED, RISER RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 1 STR. .114 16 C(UL), FT4, CMR, CL2R 10 (LBS.)   2232

    22 2 SOL. .150 16 C(UL), FT4, CMR, CL2R 20 (LBS.)   2233

    22 2 STR. .140 16 C(UL), FT4, CMR, CL2R 21 (LBS.)   2234*

    22 3 STR. .199 16 C(UL), FT4, CMR, CL2R 23 (LBS.)   2236

    22 4 SOL. .186 16 C(UL), FT4, CMR, CL2R 26 (LBS.)   2237

    22 6 STR. .255 16 C(UL), FT4, CMR, CL2R 40 (LBS.)   2239

    *1 Pair Shielded 1 Pair Unshielded

  • 8/16/2019 Catálogo Cable Génesis

    22/96

        A    R    T    I    C    L    E    7

        2    5

    20 www.honeywellcable.com

    Multi-Pair Shielded (Each Pair Shielded), Riser Rated

    Multi-Pair Shielded (Overall Shield), Riser Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Conductors are arranged inpairs, Aluminum/Mylar Shield applied overall each assembled pair, with DrainWire for each pair, Flexible Polyvinyl-Chloride Jackets. Standard Jacket Color:Gray. Conductor Color Code Chart 3.

    MULTI-PAIR SHIELDED (EACH PAIR SHIELDED) RISER RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .172 33 C(UL), FT4, CMR, CL2R 22 (LBS.)   2263

    22 2 STR. .194 33 C(UL), FT4, CMR, CL2R 23 (LBS.)   2264

    22 3 STR. .200 33 C(UL), FT4, CMR, CL2R 36 (LBS.)   2266

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStation, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits, except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Aluminum/Mylar Shieldapplied overall the assembled pairs with common Drain Wire and FlexiblePolyvinyl-Chloride Jacket. Standard Jacket Color: Gray. Conductor ColorCode Chart 1.

    MULTI-PAIR SHIELDED (OVERALL SHIELD) RISER RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .156 33 C(UL), FT4, CMR, CL2R 17 (LBS.)   228022 2 STR. .176 33 C(UL), FT4, CMR, CL2R 19 (LBS.)   2281

    22 3 SOL. .180 33 C(UL), FT4, CMR, CL2R 23 (LBS.)   2282

    22 3 STR. .202 33 C(UL), FT4, CMR, CL2R 24 (LBS.)   2283

    22 6 SOL. .230 33 C(UL), FT4, CMR, CL2R 43 (LBS.)   2284

    22 6 STR. .260 33 C(UL), FT4, CMR, CL2R 45 (LBS.)   2285

  • 8/16/2019 Catálogo Cable Génesis

    23/9621

    Jacketed Cables Unshielded, Plenum Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:   OK for use with all Power-Limited Circuits.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Low Smoke PVC insulation, Low Smoke PVCJacket. Standard Jacket Color: Natural. Conductor Color Code Chart 1(up to 12 conductors). Color Code Chart 2 (13 conductors and over).

    JACKETED CABLES UNSHIELDED, PLENUM RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .104 24 C(UL), FT6, CMP, CL2P 10 (LBS.)   3101*

    22 2 STR. .114 24 C(UL), FT6, CMP, CL2P 11 (LBS.)   3102*

    22 3 STR. .120 25 C(UL), FT6, CMP, CL2P 15 (LBS.)   3127

    22 4 SOL. .116 24 C(UL), FT6, CMP, CL2P 15 (LBS.)   3103*

    22 4 STR. .133 24 C(UL), FT6, CMP, CL2P 17 (LBS.)   3104*

    22 5 STR. .145 24 C(UL), FT6, CMP, CL2P 20 (LBS.)   3105*•

    22 6 STR. .158 24 C(UL), FT6, CMP, CL2P 24 (LBS.)   3106*

    22 8 STR. .172 24 C(UL), FT6, CMP, CL2P 30 (LBS.)   3107

    22 10 STR. .200 24 C(UL), FT6, CMP, CL2P 37 (LBS.)   3108+

    22 12 STR. .204 24 C(UL), FT6, CMP, CL2P 43 (LBS.)   3109+

    22 15 STR. .232 24 C(UL), FT6, CMP, CL2P 53 (LBS.)   3110

    20 2 STR. .132 27 C(UL), FT6, CMP, CL2P 15 (LBS.)   3112

    20 3 STR. .140 28 C(UL), FT6, CMP, CL2P 20 (LBS.)   3128

    20 4 STR. .155 27 C(UL), FT6, CMP, CL2P 25 (LBS.)   3113

    18 2 STR. .148 30 C(UL), FT6, CMP, CL2P 19 (LBS.)   3114

    18 2 SOL. .136 30 C(UL), FT6, CMP, CL2P 18 (LBS.)   3134

    18 3 STR. .159 29 C(UL), FT6, CMP, CL2P 26 (LBS.)   312618 4 STR. .172 30 C(UL), FT6, CMP, CL2P 33 (LBS.)   3115

    18 6 STR. .212 30 C(UL), FT6, CMP, CL2P 47 (LBS.)   3116+

    18 8 STR. .232 30 C(UL), FT6, CMP, CL2P 61 (LBS.)   3117+

    18 10 STR. .270 30 C(UL), FT6, CMP, CL2P 75 (LBS.)   3118+

    18 12 STR. .277 30 C(UL), FT6, CMP, CL2P 88 (LBS.)   3119+

    18 15 STR. .316 30 C(UL), FT6, CMP, CL2P 109 (LBS.)   3120+•

    16 2 STR. .172 32 C(UL), FT6, CMP, CL2P 28 (LBS.)   3121

    16 3 STR. .186 31 C(UL), FT6, CMP, CL2P 38 (LBS.)   3129+

    16 4 STR. .202 32 C(UL), FT6, CMP, CL2P 50 (LBS.)   3122+

    14 2 STR. .208 34 C(UL), FT6, CMP, CL2P 39 (LBS.)   3123+

    14 3 STR. .220 33 C(UL), FT6, CMP, CL2P 53 (LBS.)   3130

    14 4 STR. .244 34 C(UL), FT6, CMP, CL2P 70 (LBS.)   3124+12 2 STR. .265 35 C(UL), FT6, CMP, CL2P 61 (LBS.)   3125+

    *Not Twisted

    +Spools Only

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    24/96

        A    R    T    I    C    L    E    7

        2    5

    22 www.honeywellcable.com

    Jacketed Cables Overall Shield, Plenum Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStations, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Available In 500 foot or 1000 foot Tangle-Ffree Boxes or Spools.Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Low Smoke PVC Insulation, Aluminum/Mylar Shield, with Drain Wire applied over assembledconductors, Low Smoke PVC Jacket. Standard Jacket Color: Natural.Conductor Color Code Chart 1 (up to 12 conductors). Color CodeChart 2 (13 conductors and over).

    JACKETED CABLES SHIELDED, (OVERALL SHIELD) PLENUM RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .108 45 C(UL), FT6, CMP, CL2P 13 (LBS.)   3201

    22 2 STR. .120 45 C(UL), FT6, CMP, CL2P 14 (LBS.)   3202

    22 3 STR. .130 48 C(UL), FT6, CMP, CL2P 17 (LBS.)   3227

    22 4 SOL. .125 45 C(UL), FT6, CMP, CL2P 19 (LBS.)   320322 4 STR. .139 45 C(UL), FT6, CMP, CL2P 20 (LBS.)   3204

    22 6 STR. .166 45 C(UL), FT6, CMP, CL2P 27 (LBS.)   3206

    22 8 STR. .174 45 C(UL), FT6, CMP, CL2P 33 (LBS.)   3207

    22 10 STR. .210 45 C(UL), FT6, CMP, CL2P 42 (LBS.)   3208

    22 12 STR. .216 45 C(UL), FT6, CMP, CL2P 51 (LBS.)   3209

    22 15 STR. .234 45 C(UL), FT6, CMP, CL2P 63 (LBS.)   3210+

    20 2 STR. .138 48 C(UL), FT6, CMP, CL2P 19 (LBS.)   3212

    20 3 STR. .138 54 C(UL), FT6, CMP, CL2P 22 (LBS.)   3228

    20 4 STR. .159 48 C(UL), FT6, CMP, CL2P 27 (LBS.)   3213

    18 2 STR. .154 62 C(UL), FT6, CMP, CL2P 23 (LBS.)   3214

    18 3 STR. .161 58 C(UL), FT6, CMP, CL2P 29 (LBS.)   3226

    18 4 STR. .178 62 C(UL), FT6, CMP, CL2P 33 (LBS.)   321518 6 STR. .216 62 C(UL), FT6, CMP, CL2P 50 (LBS.)   3216+

    18 8 STR. .230 62 C(UL), FT6, CMP, CL2P 61 (LBS.)   3217+

    18 10 STR. .270 62 C(UL), FT6, CMP, CL2P 79 (LBS.)   3218+•

    18 12 STR. .283 62 C(UL), FT6, CMP, CL2P 90 (LBS.)   3219+

    18 15 STR. .320 62 C(UL), FT6, CMP, CL2P 114 (LBS.)   3220+•

    16 2 STR. .178 71 C(UL), FT6, CMP, CL2P 34 (LBS.)   3221+

    16 3 STR. .184 63 C(UL), FT6, CMP, CL2P 45 (LBS.)   3229+

    16 4 STR. .202 71 C(UL), FT6, CMP, CL2P 57 (LBS.)   3222+

    14 2 STR. .214 75 C(UL), FT6, CMP, CL2P 45 (LBS.)   3223+

    14 3 STR. .222 63 C(UL), FT6, CMP, CL2P 60 (LBS.)   3230+

    14 4 STR. .248 75 C(UL), FT6, CMP, CL2P 76 (LBS.)   3224+

    12 2 STR. .270 85 C(UL), FT6, CMP, CL2P 66 (LBS.)   3225+

    +Spools Only

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    25/9623

    Multi-Pair Unshielded, Plenum Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStation, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:   OK for use with all Power-Limited Circuits.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Low Smoke PVC Insulation, Conductorsare arranged in pairs, Low Smoke PVC Jacket. Standard JacketColor: Natural. Conductor Color Code Chart 3.

    MULTI-PAIR UNSHIELDED, PLENUM RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 1 SOL. .110 24 C(UL), FT6, CMP, CL2P 10 (LBS.)   3231•

    *1 Pair Shielded 1 Pair Unshielded

    • Consult factory for availability.

    Multi-Pair (Each Pair Shielded), Plenum Rated

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStation, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Low Smoke PVC Insulation, Conductors arearranged in pairs, Aluminum/Mylar Shield applied overall eachassembled pair, with Drain Wire for each pair. Low Smoke PVC Jacket.Standard Jacket Color: Natural. Conductor Color Code Chart 3.

    MULTI-PAIR (EACH PAIR SHIELDED), PLENUM RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 1 STR. .120 45 C(UL), FT6, CMP, CL2P 14 (LBS.)   3262

    22 2 SOL. .172 45 C(UL), FT6, CMP, CL2P 24 (LBS.)   3263

    22 2 STR. .194 45 C(UL), FT6, CMP, CL2P 24 (LBS.)   3264

    22 3 SOL. .183 45 C(UL), FT6, CMP, CL2P 33 (LBS.)   3265

    22 3 STR. .200 45 C(UL), FT6, CMP, CL2P 35 (LBS.)   3266

    22 4 SOL. .201 45 C(UL), FT6, CMP, CL2P 39 (LBS.)   3267

    22 6 SOL. .244 45 C(UL), FT6, CMP, CL2P 57 (LBS.)   3268

  • 8/16/2019 Catálogo Cable Génesis

    26/96

        A    R    T    I    C    L    E    7

        2    5

    24 www.honeywellcable.com

    Multi-Pair Overall Shield, Plenum Rated

    Home Automation Cable

     Applications:   Wiring Burglar Alarm, Public Address Systems, Intercoms, TelephoneStation, Speakers, Instrumentation, Control and other Low VoltageCircuits that are Power-Limited.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Low Smoke PVC Insulation, Aluminum/Mylar Shieldwith Drain Wire applied overall the assembly pairs. Low Smoke PVCJacket. Standard Jacket Color: Natural. Conductor Color Code Chart 3.

    MULTI-PAIR SHIELDED (OVERALL SHIELD), PLENUM RATED 60˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIR STR/SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 2 SOL. .156 45 C(UL), FT6, CMP, CL2P 20 (LBS.)   3280•

    22 2 STR. .176 45 C(UL), FT6, CMP, CL2P 22 (LBS.)   3281

    22 3 SOL. .180 45 C(UL), FT6, CMP, CL2P 24 (LBS.)   3282•

    22 3 STR. .202 45 C(UL), FT6, CMP, CL2P 26 (LBS.)   3283

    22 6 SOL. .240 45 C(UL), FT6, CMP, CL2P 49 (LBS.)   3284•22 6 STR. .272 45 C(UL), FT6, CMP, CL2P 53 (LBS.)   3285

    • Consult factory for availability.

     Applications:   Designed for Lighting Control and other Home Automation applications.Code Restrictions:  OK for Power-Limited Circuits, except those in Risers and Plenums.

    Construction:   22 AWG shielded copper pair for data, 18 AWG unshielded copper pair

    for power.

    HOME AUTOMATION CABLE

    JACKET AVG. WT.DESCRIPTION CONDUCTORS COLOR LISTINGS PER MFT PART#

    18 AWG 1 UNSHIELDED PAIR + STRANDED GREEN CM, CL2 30 (LBS.)   1243

    22 AWG 1 SHIELDED PAIR BC

  • 8/16/2019 Catálogo Cable Génesis

    27/9625

     Access Control Cable

     Applications:   Gated Communities, Limited Access.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Profusion Access Control Cables are held together by a revolutionarytight, continuous twist scheme that secures lock power, card reader,door contact and request for exit (Rex/Spare) cables together withoutan adhesive material, delivering a better bundled cable, while savingthe installer valuable time by eliminating the need to remove an outer jacket. This design eliminates cold weather cracking and cableseparation problems.

    Construction:

    DOOR CARD DOOR REQUEST

    GROUP STRIKE READER CONTACT FOR EXIT

    Conductor 18 AWG BC 22 AWG BC 22 AWG BC 22 AWG BC

    16/30 STR 7/30 STR 7/30 STR 7/30 STR

    Construction 4/C OAS 3 pair OAS 2/C OAS 4/C OAS

    Insulation   BLK, RED, BLK/RED, BLK, RED BLK, RED,

    Colors   WHT, GRN GRN/WHT, WHT, GRN

    ORG/BLU

    Lay Length 3" nom. Pair-2" nom. 1.75" nom. 2" nom.

    Cable-4.5" nom.

    Shield AL/Mylar AL/Mylar AL/Mylar AL/Mylar

    Jacket Color Orange White Blue Green

     ACCESS CONTROL CABLE

    DESCRIPTION PART#

    4 Leg Access Control Cable CM Rated   1298

    4 Leg Access Control Cable CMP Rated   3295

  • 8/16/2019 Catálogo Cable Génesis

    28/96

    Notes: ____________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

    __________________________________________________________________

  • 8/16/2019 Catálogo Cable Génesis

    29/9627

    Single Conductor Sprinkler and Tracer Wire

    (UL Listed Sprinkler and Tracer Wire 600V)

    These cables are designed for underground

    applications where harsh conditions may be

    encountered. One of the common uses is for tracer 

    wire. Typically, yellow tracer wire is used to mark gas

    pipes, blue to mark water pipes, orange to mark fiber 

    optic cables and green for sewage lines. Another use is

    for connecting the remote control valves to an irrigation

    controller in a golf course sprinkler system.

    Multi Conductor Sprinkler Cable

    (UL Listed Direct Burial Solid Bare Copper 30V)

    These underground multi conductor cables are used to

    control the valves in residential and commercial

    irrigation systems.

    Landscape Lighting Cable

    (UL Listed Underground Low Energy Circuit Cable 150V

    These cables are used for low-voltage direct burial

    lighting applications.

    Irrigation Cable

    Tracer Wire

  • 8/16/2019 Catálogo Cable Génesis

    30/96

        A    R    T    I    C    L    E    7

        2    5

    28 www.honeywellcable.com

    Irrigation, Tracer and Lighting Cable

     Applications:   Underground Golf Course Sprinkler Wire, Tracer Wire and Lawn Sprinkler

    Wire. Designed for underground applications where harsh conditions may

    be encountered.

    Code Restrictions:  UL Misc. Wire

    Construction:   Copper Conductor, Polyethylene Insulation. Check Factory for Availability.

    IRRIGATION, TRACER AND LIGHTING CABLE

     AVG. WT. AWG #/COND. STR/SOL DESCRIPTION PER MFT PART#

    18 1 SOL 600V Sprinkler System or Tracer Wire 11   1301

    14 1 SOL 600V Sprinkler System or Tracer Wire 20   1303

    12 1 SOL 600V Sprinkler System or Tracer Wire 28   1304

    • Please check with factory for stock and availability on put-ups and jacket colors.

    Underground Lighting

     Applications:   Underground, Low Energy Circuit Cable. Sunlight Resistant.

    Code Restrictions:   OK for Underground Circuits.

    Features:   Available in 250, 500 or 1000 foot spools. Sequential Footage Markings.

    Construction:   Heavy Wall, Integral Zip Construction. Black Jacket.

    UNDERGROUND LIGHTING

    NOM. AVG. WT. AWG #/COND. STR/SOL O.D. PER MFT PART#

    8 2 7 x 24/30 STR BC .295" x .590" 225 (LBS.)   1017

    10 2 104/30 STR BC .220" x .440" 120 (LBS.)   1018

    12 2 65/30 STR BC .190" x .390" 82 (LBS.)   1019

    14 2 41/30 STR BC .165" x .345" 50 (LBS.)   1021

  • 8/16/2019 Catálogo Cable Génesis

    31/9629

     As the world’s leading thermostat manufacturer,

    Honeywell knows about home comfort systems.

     Although it’s hidden behind the walls, the

    thermostat wire is a key component of heating and

    cooling systems. The quality of the wire can

    impact performance. As systems continue to get

    more intelligent, quality

    wire becomes a more

    important factor.

    Quality:Honeywell thermostat

    wire, like all Honeywell

    products, is manufactured to the highest quality

    standards and is recommended for use with all

    thermostats, ensuring optimal system

    performance.

    Commitment:

    If any Honeywell thermostat wire fails to perform to

    our specification during the life of any original

    installation, we will replace the cable, three for one.

    No one else in the industry makes that guarantee.

    Features:

    • Full range of thermostat and electronic low

    voltage wire

    • Polypropylene insulation provides exceptional

    dielectric and strips easily and cleanly,

    saving time• Available for General Purpose (CL2) or Plenum

    (CL2P) Applications

    • Ripcord for quick jacket removal

    • Room and zone markings printed right on jacket

    • Packaging options: Spools, SpeedbagsTM

    and Pull Boxes

    • Manufactured in ISO 9001:2000 facility to

    exacting quality standards

    • 100% guaranteed

    HoneywellThermostat Wire

  • 8/16/2019 Catálogo Cable Génesis

    32/96

        A    R    T    I    C    L    E    7

        2    5

    30 www.honeywellcable.com

    Thermostat Cable 60˚ C - CL2

    NOM. NOM. CAP. AVG. WT. AWG #/COND. PACKAGING SOL O.D. PF/FT LISTINGS PER MFT PART#

    20 2 4 x 500 S or 1 x 500 SB SOL .118 17 CL2 11   4701

    20 3 4 x 500 S or 1 x 500 SB SOL .124 17 CL2 14   4702

    20 4 4 x 250 S or 1 x 250 SB SOL .136 17 CL2 18   4703

    20 5 4 x 250 S or 1 x 250 SB SOL .148 17 CL2 20   4704

    20 6 4 x 250 S or 1 x 250 SB SOL .161 17 CL2 24   4705

    20 7 4 x 250 S or 1 x 250 SB SOL .161 17 CL2 27   4706

    20 8 4 x 250 S or 1 x 250 SB SOL .174 17 CL2 31   4707

    20 9 4 x 250 S or 1 x 250 SB SOL .188 17 CL2 35   4708•

    20 10 4 x 250 S or 1 x 250 SB SOL .204 17 CL2 39   4709•18 2 4 x 500 S or 1 x 500 SB SOL .136 19 CL2 16   4710

    18 3 4 x 500 S or 1 x 500 SB SOL .144 19 CL2 21   4711

    18 4 4 x 250 S or 1 x 250 SB SOL .157 19 CL2 26   4712

    18 5 4 x 250 S or 1 x 250 SB SOL .172 19 CL2 32   4713

    18 6 4 x 250 S or 1 x 250 SB SOL .188 19 CL2 38   4714

    18 7 4 x 250 S or 1 x 250 SB SOL .188 19 CL2 44   4715

    18 8 4 x 250 S or 1 x 250 SB SOL .204 19 CL2 50   4716

    18 9 4 x 250 S or 1 x 250 SB SOL .220 19 CL2 55   4717

    18 10 4 x 250 S or 1 x 250 SB SOL .240 19 CL2 61   4718

    18 12 1 x 250 S or 1 x 250 SB SOL .248 19 CL2 74   4719

    • Consult factory for availability. S=Spools SB=Speedbags MFT=1000 Feet

    NOM. NOM. CAP. AVG. WT.

     AWG #/COND. PACKAGING SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 2 4 x 500 S SOL .136 28 CMP, CL2P, C(UL) FT6 17   4760

    18 3 4 x 500 S SOL .144 28 CMP, CL2P, C(UL) FT6 23   4761

    18 4 4 x 250 S SOL .157 28 CMP, CL2P, C(UL) FT6 29   4762

    18 5 4 x 250 S SOL .172 28 CMP, CL2P, C(UL) FT6 35   4763

    18 6 4 x 250 S SOL .188 28 CMP, CL2P, C(UL) FT6 42   4764

    18 7 4 x 250 S SOL .188 28 CMP, CL2P, C(UL) FT6 47   4765•

    18 8 4 x 250 S SOL .204 28 CMP, CL2P, C(UL) FT6 54   4766

    18 9 4 x 250 S SOL .220 28 CMP, CL2P, C(UL) FT6 60   4767•

    18 10 4 x 250 S SOL .240 28 CMP, CL2P, C(UL) FT6 67   4768

    18 1 2 1 x 250 S SOL .248 28 CMP, CL2P, C(UL) FT6 79   4769•

    • Consult factory for availability. S=Spools MFT=1000 Feet

     Applications:   Wiring of Thermostat Controls, Heating and Air Conditioning Equipment,

    doorbells, as well as other Low Voltage Applications. Sunlight Resistant

    except CL2P.

    Features:   Sequential Footage Markings on Spools. Braided Ripcord.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risers and

    Plenums.

    Construction:   Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket.

     Applications:   Wiring of Thermostat Controls, Heating and Air Conditioning Equipment,

    doorbells, as well as other Low Voltage Applications. Sunlight Resistant

    except CL2P.

    Features:   Sequential Footage Markings on Spools. Braided Ripcord.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Construction:   Copper Conductors, Low Smoke PVC, Low Smoke PVC Jacket.

    Thermostat Cable, Plenum Rated - CL2P

  • 8/16/2019 Catálogo Cable Génesis

    33/9631

    Our Fire Alarm Cables are manufactured in a

    wide variety of gage sizes, shielding

    configurations and jacketing materials including

    plenum, riser and general purpose. Genesis also

    manufactures fire alarm cables that meet the

    requirements of New York City Local Law 5 and

    New York State Toxicity requirements.

    Features:

    • Countdown

    • New Labeling

    System on box

    • Color Coded

    Boxes

    • Zone and Room

    Markings

     Article 760

    The scope of this article covers the installation

    of wiring and equipment of fire alarm systems

    including all circuits controlled and powered by

    the fire alarm system. These include fire detection

    and alarm notification, guard’s tour, sprinkler 

    waterflow and sprinkler supervisory systems:

    Circuits controlled and powered by the fire alarm

    system include circuits for the control of building

    systems safety functions, elevator capture,

    elevator shutdown, door release, smoke doors

    and damper control, fire doors and damper 

    control and fan shutdown. Applicable only where

    these circuits are powered by and controlled by

    the fire alarm system.

    Fire Power Limited Cable:  Type FPL, FPLR, FPLP

    Fire Alarm

  • 8/16/2019 Catálogo Cable Génesis

    34/96

        A    R    T    I    C    L    E    7

        6    0

    32 www.honeywellcable.com

    Fire Alarm Jacketed Unshielded

    FIRE ALARM CABLES

    Fire Alarm Jacketed Unshielded, Direct Burial

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risers

    and Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.

    Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket.

    Standard Jacket Color: Red or White. Conductor Color Code Chart 4.

    FIRE ALARM JACKETED UNSHIELDED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 4 SOL. .122 15 FPL 15 (LBS.)   4101*

    22 6 SOL. .144 15 FPL 19 (LBS.)   4102

    22 8 SOL. .156 15 FPL 24 (LBS.)   4103

    22 10 SOL. .182 15 FPL 31 (LBS.)   4104

    22 12 SOL. .188 15 FPL 37 (LBS.)   4105

    18 2 SOL. .134 20 FPL 17 (LBS.)   4106

    18 4 SOL. .170 20 FPL 29 (LBS.)   4107*18 6 SOL. .192 20 FPL 41 (LBS.)   4108+

    18 8 SOL. .208 20 FPL 52 (LBS.)   4109+

    18 10 SOL. .244 20 FPL 68 (LBS.)   4110+

    16 2 SOL. .154 20 FPL 24 (LBS.)   4111

    16 4 SOL. .180 20 FPL 43 (LBS.)   4112+

    14 2 SOL. .182 22 FPL 35 (LBS.)   4113+

    14 4 SOL. .214 22 FPL 64 (LBS.)   4114+

    12 2 SOL. .214 22 FPL 52 (LBS.)   4115+

    *Not Twisted

    +Spools Only

     Applications:   Wiring for Outdoor or Underground. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risers

    and Plenums, but intended for Outdoor or Underground Use.

    Features:   Available in 500 foot or 1000 foot Spools. Sequential Footage Markings.

    Construction:   Stranded Copper Conductors, PVC Insulation, High Molecular Weight

    PVC Jacket Color: Black. Conductor Color Code Chart 4.

    FIRE ALARM JACKETED UNSHIELDED, DIRECT BURIAL 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. STR O.D. PF/FT LISTINGS PER MFT PART#

    18 2 STR. .260 19 FPL, CL2 37(LBS.)   4156

    18 4 STR. .295 19 FPL, CL2 59 (LBS.)   4157*

    18 6 STR. .345 19 FPL, CL2 76 (LBS.)   4158

    16 2 STR. .282 21 FPL, CL2 45 (LBS.)   4151

    14 2 STR. .310 23 FPL, CL2 60 (LBS.)   4153

    14 4 STR. .355 23 FPL, CL2 102 (LBS.)   4154

    *Not Twisted

  • 8/16/2019 Catálogo Cable Génesis

    35/9633

    Fire Alarm Jacketed Shielded (Overall Shield)

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risers

    and Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.

    Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Polypropylene Insulation, Aluminum/Mylar

    Shield with Drain Wire applied overall the assembled conductors.

    Flexible Polyvinyl-Chloride Jacket. Standard Jacket Color: Red or White,

    Conductor Color Code Chart 4.

    FIRE ALARM JACKETED SHIELDED (OVERALL SHIELD) 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 4 SOL. .124 31 FPL 17 (LBS.)   4201

    18 2 SOL. .138 42 FPL 20 (LBS.)   4202

    18 4 SOL. .160 42 FPL 31 (LBS.)   4203

    18 6 SOL. .196 42 FPL 50 (LBS.)   4204

    18 8 SOL. .212 42 FPL 57 (LBS.)   4205+

    16 2 SOL. .158 46 FPL 29 (LBS.)   4206

    16 4 SOL. .186 46 FPL 49 (LBS.)   4207+

    14 2 SOL. .186 52 FPL 40 (LBS.)   4208+

    14 4 SOL. .218 52 FPL 67 (LBS.)   4209+

    12 2 SOL. .218 56 FPL 59 (LBS.)   4210+

    +Spools Only

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Risers

    and Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.

    One Conductor Ribbed for Polarity. Sequential Footage Markings.

    Construction:   Copper Conductors Laid Parallel in a Zipcord Style. Integral

    Polyvinyl-Chloride Insulation. Standard Colors: Red, White.

    FIRE ALARM ZIPCORD 75˚ CNOM. NOM. CAP. AVG. WT.

     AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 2 SOL. .105 x .217 17 FPL, C(UL) CMG 18 (LBS.)   4002

    14 2 SOL. .129 x .273 17 FPL, C(UL) CMG 39 (LBS.)   4004

    • Consult factory for availability.

    Fire Alarm Zipcord

  • 8/16/2019 Catálogo Cable Génesis

    36/96

        A    R    T    I    C    L    E    7

        6    0

    34 www.honeywellcable.com

    Fire Alarm Jacketed Unshielded, Riser Rated

    Fire Alarm Jacketed (Overall Shield), Riser Rated

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket.

    Standard Jacket Color: Red or White, Conductor Color Code Chart 4.

    FIRE ALARM JACKETED UNSHIELDED, RISER RATED 75˚C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 4 SOL. .122 15 FPLR/CL2R, C(UL), FT4 15 (LBS.)   4301

    22 6 SOL. .144 15 FPLR/CL2R, C(UL), FT4 19 (LBS.)   4302•

    22 8 SOL. .156 15 FPLR/CL2R, C(UL), FT4 25 (LBS.)   4303•

    22 10 SOL. .182 15 FPLR/CL2R, C(UL), FT4 30 (LBS.)   4304•

    22 12 SOL. .188 15 FPLR/CL2R, C(UL), FT4 36 (LBS.)   4305•

    18 2 SOL. .138 19 FPLR/CL2R, C(UL), FT4 17 (LBS.)   4306

    18 4 SOL. .174 19 FPLR/CL2R, C(UL), FT4 34 (LBS.)   4307

    18 6 SOL. .187 19 FPLR/CL2R, C(UL), FT4 44 (LBS.)   4308+

    18 8 SOL. .208 19 FPLR/CL2R, C(UL), FT4 54 (LBS.)   4309+

    18 10 SOL. .244 19 FPLR/CL2R, C(UL), FT4 67 (LBS.)   4310+

    16 2 SOL. .160 20 FPLR/CL2R, C(UL), FT4 24 (LBS.)   4311

    16 4 SOL. .184 20 FPLR/CL2R, C(UL), FT4 43 (LBS.)   4312+

    14 2 SOL. .184 22 FPLR/CL2R, C(UL), FT4 37 (LBS.)   4313+

    14 4 SOL. .214 22 FPLR/CL2R, C(UL), FT4 65 (LBS.)   4314+

    12 2 SOL. .214 22 FPLR/CL2R, C(UL), FT4 55 (LBS.)   4315+

    +Spools Only

    • Consult factory for availability.

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket.Standard Jacket Color: Red or White, Conductor Color Code Chart 4.

    FIRE ALARM JACKETED (OVERALL SHIELD), RISER RATED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 4 SOL. .126 31 FPLR/CL2R, C(UL), FT4 16 (LBS.)   4401

    18 2 SOL. .138 42 FPLR/CL2R, C(UL), FT4 21 (LBS.)   4402

    18 4 SOL. .163 42 FPLR/CL2R, C(UL), FT4 32 (LBS.)   4403

    18 6 SOL. .196 42 FPLR/CL2R, C(UL), FT4 46 (LBS.)   4404

    18 8 SOL. .212 42 FPLR/CL2R, C(UL), FT4 56 (LBS.)   4405+

    16 2 SOL. .158 46 FPLR/CL2R, C(UL), FT4 31 (LBS.)   4406

    16 4 SOL. .190 46 FPLR/CL2R, C(UL), FT4 49 (LBS.)   4407+

    14 2 SOL. .192 52 FPLR/CL2R, C(UL), FT4 42 (LBS.)   4408+

    14 4 SOL. .218 52 FPLR/CL2R, C(UL), FT4 72 (LBS.)   4409+

    12 2 SOL. .218 56 FPLR/CL2R, C(UL), FT4 60 (LBS.)   4410+

    +Spools Only

  • 8/16/2019 Catálogo Cable Génesis

    37/9635

    Fire Alarm Zipcord, Riser Rated

    Fire Alarm Mid Cap Unshielded, Riser Rated

    Fire Alarm Mid Cap (Overall Shield), Riser Rated

     Applications:   Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.One Conductor Ribbed for Polarity. Sequential Footage Markings.

    Construction:   Copper Conductors, Polyvinyl-Chloride Insulation.

    Standard Colors: White, Blue, Red.

    FIRE ALARM ZIPCORD, RISER RATED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 2 SOL. .088 x .196 17 FPLR/CL2R, C(UL), FT4 18 (LBS.)   4422

    16 2 SOL. .094 x .200 17 FPLR/CL2R, C(UL), FT4 26 (LBS.)   4423

    14 2 SOL. .107 x .220 17 FPLR/CL2R, C(UL), FT4 37 (LBS.)   4424+

    12 2 SOL. .124 x .250 17 FPLR/CL2R, C(UL), FT4 52 (LBS.)   4425+

    +Spools Only

     Applications:   Wiring of Mid-Capacitance Addressable Fire-Protective SignalingCircuits. Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools.Sequential Footage Markings.

    Construction:   Copper Conductors, Polypropylene Insulation, Polyvinyl-ChlorideJacket. Standard Jacket Color: Red, Conductor Color Code Chart 4.

    FIRE ALARM MID CAP UNSHIELDED, RISER RATED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 2 SOL. .144 15 FPLR/CL2R, C(UL), FT4 19 (LBS.)   443116 2 SOL. .170 17 FPLR/CL2R, C(UL), FT4 26 (LBS.)   4432+

    14 2 SOL. .208 19 FPLR/CL2R, C(UL), FT4 38 (LBS.)   4433+

    12 2 SOL. .256 22 FPLR/CL2R, C(UL), FT4 60 (LBS.)   4434+•

    +Spools Only • Consult factory for availability.

     Applications:   Wiring of Mid-Capacitance Fire-Protective Signaling Circuits.Sunlight Resistant.

    Code Restrictions:  OK for use with all Power-Limited Circuits except those in Plenums.

    Features:   Available in 500 foot or 1000 foot Spools. Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Polypropylene Insulation, Aluminum/MylarShield with Drain Wire, Polyvinyl-Chloride Jacket. Standard JacketColor: Red, Conductor Color Code Chart 4.

    FIRE ALARM MID CAP SHIELDED (OVERALL SHIELD) RISER RATED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 2 SOL. .148 34 FPLR/CL2R, C(UL), FT4 21 (LBS.)   4441

    16 2 SOL. .187 38 FPLR/CL2R, C(UL), FT4 32 (LBS.)   4442

    14 2 SOL. .212 41 FPLR/CL2R, C(UL), FT4 43 (LBS.)   4443•

    12 2 SOL. .260 48 FPLR/CL2R, C(UL), FT4 48 (LBS.)   4444

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    38/96

        A    R    T    I    C    L    E    7

        6    0

    36 www.honeywellcable.com

    Fire Alarm Jacketed Unshielded, Plenum Rated

    Fire Alarm Jacketed (Overall Shield), Plenum Rated

     Applications:   Wiring of Fire-Protective Signaling Circuits.

    Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Available in 500 foot or 1000 foot Tangle-Free Boxes or Spools. Sequential

    Footage Markings.

    Construction:   Copper Conductors, Low Smoke PVC Insulation, Low Smoke PVC Jacket

     And Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4.

    FIRE ALARM JACKETED UNSHIELDED, PLENUM RATED 75˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 6 SOL. .144 22 FPLP/CL2P C(UL), FT6 21 (LBS.)   4502

    22 10 SOL. .182 22 FPLP/CL2P C(UL), FT6 33 (LBS.)   4504•

    22 12 SOL. .188 22 FPLP/CL2P C(UL), FT6 38 (LBS.)   4505

    18 2 SOL. .134 24 FPLP/CL2P C(UL), FT6 19 (LBS.)   4506

    18 4 SOL. .156 24 FPLP/CL2P C(UL), FT6 32 (LBS.)   4507

    18 6 SOL. .192 24 FPLP/CL2P C(UL), FT6 45 (LBS.)   4508+

    16 2 SOL. .154 27 FPLP/CL2P C(UL), FT6 26 (LBS.)   4511

    16 4 SOL. .180 27 FPLP/CL2P C(UL), FT6 47 (LBS.)   4512+14 2 SOL. .182 27 FPLP/CL2P C(UL), FT6 38 (LBS.)   4513+

    14 4 SOL. .214 27 FPLP/CL2P C(UL), FT6 68 (LBS.)   4514+

    12 2 SOL. .214 30 FPLP/CL2P C(UL), FT6 55 (LBS.)   4515+

    +Spools Only • Consult factory for availability.

     Applications:   Wiring of Fire-Protective Signaling Circuits.Code Restrictions:  OK for use with all Power-Limited Circuits.

    Features:   Available In 500 foot or 1000 foot Tangle-Free Boxes or Spools.

    Sequential Footage Markings.

    Construction:   Twisted Copper Conductors, Low Smoke PVC Insulation,

     Aluminum /Mylar Shield With Drain Wire Low Smoke PVC Jacket and

    Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4.

    FIRE ALARM JACKETED SHIELDED (OVERALL SHIELD) PLENUM RATED 750 C

    NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART#

    22 4 SOL. .126 53 FPLP/CL2P C(UL), FT6 18 (LBS.)   4601

    18 2 SOL. .140 68 FPLP/CL2P C(UL), FT6 22 (LBS.)   4602

    18 4 SOL. .168 68 FPLP/CL2P C(UL), FT6 35 (LBS.)   4603

    18 6 SOL. .196 68 FPLP/CL2P C(UL), FT6 50 (LBS.)   4604+

    16 2 SOL. .158 77 FPLP/CL2P C(UL), FT6 35 (LBS.)   4606

    16 4 SOL. .186 77 FPLP/CL2P C(UL), FT6 52 (LBS.)   4607+

    14 2 SOL. .186 86 FPLP/CL2P C(UL), FT6 44 (LBS.)   4608+

    14 4 SOL. .218 86 FPLP/CL2P C(UL), FT6 75 (LBS.)   4609+

    12 2 SOL. .218 96 FPLP/CL2P C(UL), FT6 63 (LBS.)   4610+

    +Spools Only

  • 8/16/2019 Catálogo Cable Génesis

    39/9637

    Jacketed Unshielded LL5

    Jacketed Shielded LL5 (Overall Shield)

     Applications:   Fire Protective Signaling Circuits installed in the City of New York.

    Code Restrictions:  Meets the requirements of New York City Local Law 5, and New

     York State Toxicity.

    Features:   Available in 500 foot or 1000 foot Spools. Sequential Footage Markings.

    Construction:   Copper Conductors, Fluoropolymer Insulation and Jacket.

    Standard Jacket Color: Red. Color Code Chart 4.

    JACKETED UNSHIELDED LL5 150˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIRS SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 1 SOL. .198 45 FPLP, NYC LL5 26 (LBS.)   5500•

    18 2 SOL. .312 45 FPLP, NYC LL5 47 (LBS.)   5501•

    16 1 SOL. .214 55 FPLP, NYC LL5 36 (LBS.)   5502

    116 2 SOL. .345 55 FPLP, NYC LL5 62 (LBS.)   5503•

    14 1 SOL. .244 60 FPLP, NYC LL5 47 (LBS.)   5504

    14 2 SOL. .374 60 FPLP, NYC LL5 87 (LBS.)   5506

    12 1 SOL. .272 65 FPLP, NYC LL5 67 (LBS.)   5505•

    • Consult factory for availability.

     Applications:   Fire Protective Signaling Circuits installed in the City of New York.Code Restrictions:  Meets the requirements of New York City Local Law 5, and New

     York State Toxicity.

    Features:   Available in 500 foot or 1000 foot Spools. Sequential Footage

    Markings.

    Construction:   Copper Conductors, Fluoropolymer Insulation, Aluminum/Mylar Shield

    and Fluoropolymer Jacket. Standard Jacket Color: Red. Color Code

    Chart 4.

    JACKETED SHIELDED LL5 (OVERALL SHIELD) 150˚ C

    NOM. NOM. CAP. AVG. WT. AWG #/PAIRS SOL O.D. PF/FT LISTINGS PER MFT PART#

    18 1 SOL. .202 80 FPLP, NYC LL5 28 (LBS.)   5550•18 2 SOL. .316 80 FPLP, NYC LL5 51 (LBS.)   5551•

    16 1 SOL. .215 100 FPLP, NYC LL5 42 (LBS.)   5552

    16 2 SOL. .343 100 FPLP, NYC LL5 71 (LBS.)   5553

    14 1 SOL. .243 110 FPLP, NYC LL5 51 (LBS.)   5554

    14 2 SOL. .398 110 FPLP, NYC LL5 93 (LBS.)   5555•

    12 1 SOL. .276 130 FPLP, NYC LL5 75 (LBS.)   5556•

    • Consult factory for availability.

  • 8/16/2019 Catálogo Cable Génesis

    40/96

    weʼve got the cure

    For more information, please visit   www.honeywellcable.com

    © 2009 Honeywell International Inc. All rights reserved

    Honeywell’s Self-Diagnostic Cable. Your Prescription for Success.

    Relief is on the way with the industry’s only patented self-healing HDMI

    cable with CURE Light Technology. Thanks to a unique, embedded

    line driver designed to detect and “cure” problematic loading and

    communication issues, you can count on our cables to monitor and

    provide instant feedback on Hot Plug Detect, 5 Volt Line, EDID and

    HDCP status.

    The prognosis? You’ll reduce installation costs while delivering the

    superior format and brilliant, crystal-clear resolution your customers

    deserve. It’s your prescription for success!

  • 8/16/2019 Catálogo Cable Génesis

    41/9639

    The Honeywell Genesis Crystal Series is an

    innovative line of advanced, top quality cables,

    developed to assist the CE professional in crafting

    “state-of-the-art” home theater and audio/video

    systems. CE professionals demand cable solutions

    that offer uncompromising performance. They want

    cables that are lightweight, flexible and visually

    appealing. Crystal Series cables are constructed

    with premium materials allowing the ultimate

    synthesis of artistic performance and technical

    sophistication. For example, Crystal Audio Series

    cables use only high-strand count, oxygen-free

    copper conductors for the purest sound transmission.

    Crystal Video Series serial digital coaxial cables

    utilize a bare copper center conductor with a gas

    injected dielectric to deliver bandwidth of 3 GHz.

    They are UL Listed and stringently tested to

    surpass the industry’s high standards.

    Genesis CrystalSeries Cable

  • 8/16/2019 Catálogo Cable Génesis

    42/9640 www.honeywellcable.com

    GENESIS CRYSTAL SERIES

    Mini-RGB Component Video Cable

    Profusion RG59 RGB Component Video

     Applications:   Component video cables are a key element of any home theater

    system. These 75 ohm cables carry video signals from a source

    (e.g. DVD Player) to a load (e.g. TV Monitor).

    Features:   • 100% Foil Shield

    • 95% Tinned Copper Braid Shield

    • Gas Injected Dielectric

    • 81% VP

    • Super Flexible Easy Strip TPE Outer Jacket

    • Ripcord for Jacket Overall Removal

    • 24 AWG Low Loss Solid Bare Copper Center Conductor

    • Sweep Tested

    MINI-RGB COMPONENT VIDEO CABLE

    COAXIAL JACKET NOM. AVE.STYLE COLORS SHIELD OHMS O.D. CAP. LISTING WT/MFT PART#

    3 X Mini-Coax Red, Green 95% TC & 75 0.375 17 CM 90 (LBS.)   5019

    & Blue 100% Foil

    5 X Mini-Coax Red, Green, 95% TC & 75 0.475 17 CM 135 (LBS.)   5029

    Blue, Yellow 100% Foil

    & White

    6 X Mini-Coax Red, Green, 95% TC & 75 0.54 17 CM 145 (LBS.)   5099

    Blue, Yellow 100% Foil

    White & Gray

    5 X Mini-Coax Red, Green, 95% TC & 75 0.620 17 CM 150(LBS.)   5098

    + CAT 5e Blue, Yellow 100% Foil

    White

     Applications:   Component video cables are key elements of any home theatersystem. This 75 ohm cable carries video and audio signals from

    the source (e.g. DVD Player) to a load (e.g. TV Monitor).

    Features:   • 95% TC Braided Shield

    • 100% Aluminum Foil Shield

    • Gas Injected Dielectric

    • Un-Jacketed Profusion Design

    • Sweep Tested to 3 GHz

    • Lighter and More Flexible

    RG59 RGB COMPONENT VIDEO CABLE

    COAXIAL JACKET NOM. AVE.STYLE COLORS SHIELD OHMS O.D. CAP. LISTING WT/MFT PART#

    3 X RG59 Red, Green 95% TC & 75 .360 16.2 CMX 86 (LBS.)   5036& Blue 100% Foil

    5 X RG59 Red, Green, 95% TC & 75 .600 16.2 CMX 144 (LBS.)   5052

    Blue, Yellow 100% Foil

    & Clear

  • 8/16/2019 Catálogo Cable Génesis

    43/9641

    Profusion Mini-RGB Component Cable

    Crystal Series Professional Audio & Home Theater 

     Applications:   Component video cables are key elements of any home theater

    system. This 75 ohm cable carries video and audio signals from

    the source (e.g. DVD Player) to a load (e.g. TV Monitor).

    Features:   • 95% TC Braided Shield

    • 100% Aluminum Foil Shield

    • Gas Injected Dielectric

    • Un-Jacketed Profusion Design

    • Sweep Tested

    • Lighter and More Flexible

    RGB COMPONENT VIDEO CABLE

    COAXIAL JACKET NOM. AVE.STYLE COLORS SHIELD OHMS O.D. CAP. LISTING WT/MFT PART#

    3 X RG59 Red, Green 95% TC & 75 0.315” 16.2 CM 86 (LBS.)   5094

    & Blue 100% Foil

    5 X RG59 Red, Green, 95% TC & 75 0.400” 16.2 CM 144 (LBS.)   5095

    Blue, Yellow 100% Foil

    & Clear

     Applications:   High-End Home Theater, Professional & Studio Sound System& Surround System

    Code Restrictions:  OK for Power-Limited Circuits, except those in Risers and Plenums.

    Construction:   High-Strand Oxygen Free Copper Conductors. Extra-Flexible Jacket.

    CRYSTAL SERIES PROFESSIONAL AUDIO & HOME THEATER

    NOM. #STR#/ STR/ NOM. CAP. OXYGEN JACKET AVG. WT.

     AWG COND. SOL O.D. PF/FT FREE BC COLOR LISTINGS PER MFT PART#

    16 2 STR .225" 19pF/ft 65 STR Light Purple or White CM/CL3 45 (LBS)   5290

    16 4 STR .275" 19pF/ft 65 STR Dk. Purple or White CM/CL3 65 (LBS)   5291

    14 2 STR .275" 19pF/ft 105 STR Light Green or White CM/CL3 62 (LBS)   5292

    14 4 STR .335" 19pF/ft 105 STR Dark Green or White CM/CL3 105 (LBS)   5293

    12 2 STR .320" 21.5pF/ft 168 STR Light Green CM/CL3 93 (LBS)   5294

  • 8/16/2019 Catálogo Cable Génesis

    44/9642 www.honeywellcable.com

    Crystal Series Digital and HDTV Clear RG59 Coaxial Cable

    Crystal Series Digital and HDTV Coaxial Cable

     Applications:   High-End Home Theater, HDTV, Production, Satellite, Digital

    and Analog Broadcast.

    Code Restrictions:  OK for CMX uses.

    Features:   Available in 500 foot Reel-in-a-Box. Tested to 3 GHz.

    Construction:   Foamed Dielectric over Solid Bare Copper Center Conductor.95% Tinned Copper Braid Shield and 100% Foil Shield.

    Jacket Colors: Translucent Red, Green, Blue, Yellow and Clear.

    CRYSTAL SERIES DIGITAL AND HDTV CLEAR RG59 COAXIAL CABLE

    NOM. NOM. CAP. AVG. WT.STYLE SHIELD AWG O.D. PF/FT LISTINGS PER MFT PART#

    RG59 95% TC 20 BC .242 16.2 CMX 29 (LBS.)   5035

    100% Foil

     Applications:   High-End Home Theater, HDTV, Production, Satellite, Analog andDigital Broadcast.

    Code Restrictions:  OK for General Purpose use except in Riser and Plenums.

    Features:   Available in 500 foot Reel-in-a