Par Concrete

download Par Concrete

of 8

description

RCP PIPES

Transcript of Par Concrete

  • ParConcrete P r o d u c t s c o r p o r a t i o n

    MACHINE PRESSED CONCRETE PIPES

    Main Office: 3rd Floor A & E Building, Gov. Fortunato Halili Ave., Bagbaguin, Sta. Maria, BulacanTel. No. (044)641-1867 Fax No. (044)641-1870 Plant Site: Km.38 Pulong Buhanging, Sta. Maria, BulacanTel. No. (044)641-1636

    ParConcrete P r o d u c t s c o r p o r a t i o n

    MACHINE PRESSED CONCRETE PIPES

    3rd Floor A & E Building, Gov. Fortunato Halili Ave., Bagbaguin, Sta. Maria, Bulacan

    Km.38 Pulong Buhanging, Sta. Maria, Bulacan

  • M I S S I O N S T A T E M E N T

    Our main goal is to provide high strength, high quality, concrete products. This endeavor to support the developers, construction companies and builders in their quest to provide and attain high quality drainage and sewer facilities in their developmental projects has always motivated our company to inculcate efficiency and team work in our systems. We have, also, continued our efforts to uplift the discipline involved in concrete pipe casting by introducing new technology through proper research and development and improve our methodologies and production processes.

    Par Concrete Pipe Manufacturing facility at Km.38 Pulong Buhangin, Sta. Maria Bulacan

    Description of Manufacturing Plant

    Our Manufacturing plant is located on a 21,000 square meter property at Km.38 Pulong Buhangin, Sta. Maria, Bulacan. It is 15 kilometers away from the cement factories and 5 kilometers away from aggregate crushing

    plants.

    View of Curing Areas and stockyard from the platform of the Concrete Batching Plant

  • Compartmentalized Materials Storage

    Fine and coarse aggregates are carefully stored in different compartments to ensure the consistency in the proportion of aggregates in our concrete mix. These materials are washed before loading to different hoppers above the batching plant to ensure that the materials we use are free from clay or other indigenous agents that may affect the strength of our concrete mix. Materials Storage Bin 1 & 2 for Fine Aggregates Materials Storage Bin 1 & 2 for Coarse Aggregates

    Proportioning of Materials

    After the proper segregation and cleaning of the fine and coarse aggregates, the materials are then conveyed to the batching plant and are batched by weight in accordance with the specifications to ensure the consistency of the concrete mix.

    Materials being loaded and Conveyed to Batching Plant

  • Concrete Mix

    Our dry cast method of production requires a consistent proportioning of fine and coarse mineral aggregates and Portland Cement, in order to attain concrete strength of up to 4500 psi and sometimes when necessary up to 5000 psi. To achieve this goal, a concrete batching plant have been installed in our manufacturing plant. Fine and coarse aggregates, Portland cement, and water are all measured by weight before loading into our concrete turbine mortar mixer. The materials are then mixed thoroughly to attain a consistent concrete mixture in all the pipes that we manufacture.

    View of the Conveyor, Cement Silo, Batching Plant and Mixer

    Control Panel of the Machines together with the Digital Scales

  • Pipe Casting

    After achieving the desired concrete mixture and fabricating the reinforcing bars, the materials are brought to the concrete pipe casting area. The adequately mixed low slump concrete mix is then distributed on to the vertical moulds while the external vibrators attached to the moulds are activated. The intense vibration applied ensures maimum compaction and produces a high density of concrete in the concrete pipe walls during concrete placement. The upper portion of the mould is sealed and blows of pressure of up to 8000 psi is applied to drive out excess water. The pipe is then lifted to the curing area and are inspected by our quality control technicians. View of the Concrete Pipe Casting Area

    Personnel Assisting the Machine in Loading Concrete to the Pipe Mould

    Reinforcing Bars Fabrication Area

    Steel Reinforcement for our pipes are fabricated in a different building. These reinforcing rings are spliced, formed according to the approved specifications of the client, tied or spot welded, weighed and inspected before being transferred and used in the concrete pipe casting area. View of the Reinforcing Bars Fabrication Area

  • Materials Handling and Delivery

    We have 4 units of Forklifts that are used for the proper handling and storage of our finished products. We also have 10 units of 10-wheeler Cargo Trucks that are used for deliveries to our customers. These are used together with back-up units of two trailers to ensure that our commitment on deliveries always arrive on time. View of the Conveyor, Cement Silo, Batching Plant and Mixer

    View of the Steel Fabrication Area and Stockyard

    View of the Curing Area

    View of the Stockyard from the Platform of the Batching Plant

    View of the Conveyor, Cement Silo, Batching Plant, Mixer and Curing Areas

  • List of Products & Production Capacity

    DAILY

    PRODUCTION

    SIZES OF CONCRETE PIPES CLASS

    I

    CLASS

    II

    CLASS

    III

    CLASS

    IV

    CLASS

    V

    400 pcs 150 mm DIA. X 1.0 m (6 in. DIAMETER) + +

    400 pcs 200 mm DIA. X 1.0 m (8 in. DIAMETER) + +

    400 pcs 250 mm DIA. X 1.0 m (10 in. DIAMETER) + +

    400 pcs 300 mm DIA. X 1.0 m OR 1.25 m (12 in. DIAMETER) + + + +

    250 pcs 375 mm DIA. X 1.0 m OR 1.25 m (15 in. DIAMETER) + + + + +

    250 pcs 450 mm DIA. X 1.0 m OR 1.25 m (18 in. DIAMETER) + + + + +

    200 pcs 600 mm DIA. X 1.0 m OR 1.25 m (24 in. DIAMETER) + + + + +

    180 pcs 750 mm DIA. X 1.0 m OR 1.25 m (30 in. DIAMETER) + + + + +

    150 pcs 900 mm DIA. X 1.0 m OR 1.25 m (36 in. DIAMETER) + + + + +

    100 pcs 1050 mm DIA. X 1.0 m OR 1.25 m (42 in. DIAMETER) + + + + +

    75 pcs 1200 mm DIA. X 1.0 m OR 1.25 m (48 in. DIAMETER) + + + + +

    70 pcs 1350 mm DIA. X 1.0 m OR 1.25 m (54 in. DIAMETER) + + + + +

    70 pcs 1500 mm DIA. X 1.0 m OR 1.25 m (60 in. DIAMETER) + + + + +

    70 pcs 1800 mm DIA. X 1.0 m OR 1.25 m (72 in. DIAMETER) + + + +

    50 pcs 2100 mm DIA. X 1.0 m OR 1.25 m (84 in. DIAMETER) + + + +

    MANHOLE RISERS

    50 pcs 900 mm dia + +

    50 pcs 1200 mm dia + +

    MANHOLE TAPERED SECTIONS

    50 pcs 600 mm dia. X 900 mm dia. + +

    50 pcs 600 mm dia. X 1200 mm dia. + +

    + = Available