Grup de Sensors & Biosensors GSB  · HRP-antiDig mismatch DNA digoxigenin probe magnet magnetic...

22
Grup de Sensors & Biosensors GSB http://sensors.uab.es Info: [email protected]

Transcript of Grup de Sensors & Biosensors GSB  · HRP-antiDig mismatch DNA digoxigenin probe magnet magnetic...

Grup de Sensors & Biosensors GSBhttp://sensors.uab.es

Info: [email protected]

GSB[Fundación (1983)]Permanentes (6) Salvador Alegret, CU

Jordi Bartrolí, CUJulian Alonso, CUEsteve Martínez, TUManel del Valle, TUFrancisco Céspedes, AU

Contratados (4) Dmitri Muraviev, RyCMa. José Esplandiu, RyCMa. Isabel Pividori, LUMireia Baeza, LUArben Merkoçi*, ICN

Postdocs (1)Postgrados > 25

GSBtaxonomía evolutiva

1983 1993 2003Potentiometricelectrodes/FIA 1988

GSB

Convergingtechnologies

Biosensor

BioSens

IntegratedAnalyticalSystems

ABIArtificial

BiosensingInterfaces

Sensors

GRUP de SENSORS i BIOSENSORS GRUP de SENSORS i BIOSENSORS -- TECNOLOGIASTECNOLOGIAS

MEMBRANASPOTENCIOMETRICAS

TRANSDUCTORESOPTICOS ELECTRICOS

SPR SENSORES FIBRA OPTICA

SENSORES OPTO-

ELECTRONICOS

TRANSISTORES DE EFECTO DE CAMPO

(ISFET)

ELECTRODOS SELECTIVOSDE IONES

SENSORES AMPEROMETRICOS

MEMBRANASOPTICAS

TECNOLOGIA MICROELECTRONICA

POLIMEROS YCOMPOSITES

MATERIALESBIOCOMPOSITES

TECNOLOGIABIOQUIMICA

ENZIMAS

ANTICUERPOS

INMUNOSENSORESINMUNOSENSORES

TECNOLOGIACONVENCIONAL

ADN

GENOSENSORESGENOSENSORES

ADITIVOSIONOFOROSCROMOFOROS

QUÍMICA

SENSORES IMPEDIMETRICOS

DISPOSITIVOS 1 SOLO USO

(SERIGRAFIA)

DISPOSITIVOS 1 SOLO USO

(SERIGRAFIA)

NANOCOMPÓSITOSNANOCOMPÓSITOS

NANOPARTICULASNANOPARTICULAS

NANOTUBOS DE CNANOTUBOS DE C

SISTEMAS BIOMIMETICOS

LENGUAS ELECTRONICAS

POTENCIOMETRICAS

LENGUAS ELECTRONICAS

VOLTAMPEROMETRICAS

INFORMATICA

BIOSENSORESBIOSENSORESSENSORES QUIMICOSSENSORES QUIMICOS

(BIO)ANALIZADORES(BIO)ANALIZADORES

SISTEMAS ANALITICOSINTEGRADOS

(BIO) ANALIZADORES

AUTOMATIZADOS

FIA

SIA

WILSON & WILSON’SCOMPREHENSIVE

ANALYTICAL CHEMISTRYEDITED BY

D. BARCELÓ

VOLUME XXXIX

INTEGRATED ANALYTICAL SYSTEMS

BY

S. ALEGRET, Ed.

ELSEVIER

AMSTERDAM LONDON NEW YORK OXFORD PARIS SHANNON TOKYO

NANO BIO

INFO

COGNO

CONVERGING TECHNOLOGIES

NANO-BIO-INFO-COGNITIVE SYSTEMS

NANO-BIO-ANALYTICAL SYSTEMS

1. ION-SELECTIVE ELECTRODES (ISE)PVC membrane / graphite-polymer composite

Tubular electrodes Integrated flow-continuous systems

2. ION-SELECTIVE FIELD EFFECT TRANSISTORS (ISFET)

Chip (micro) Probe (meso) Gauge (macro)

[email protected]

3. ANALYSERS FOR ENVIRONMENTAL MONITORING BASED ON THE FIA TECHNIQUE (FLOW INJECTION ANALYSIS) AND ON POTENTIOMETRIC DETECTION

In collaboration with ADASA Sistemas, S.A

4. NETWORK OF AUTOMATIC STATIONS FOR WATER QUALITY CONTROL

[email protected]

Desarrollo y evaluación de analizadores automáticos para el control de parámetros de interés medioambiental en aguas

Estación Automática de Control de la Calidad

RÍO LLOBREGAT EN CASTELLBELL

RIERA DE RUBÍ EN RUBÍ

RÍO ANOIA EN MARTORELL

RED AUTOMÁTICA DE MONITORIZACIÓN DE LA CALIDAD DE LAS AGUAS (XACQA)

GÁLLEGO EN ZARAGOZA

EBRO EN MENDAVIA

ZADORRA EN ARCE

IREGUA EN ISLALLANA

EBRO EN MIRANDA

RED AUTOMÁTICA DE MONITORIZACIÓN DE LA CALIDAD DE LAS AGUAS (SAICA-EBRO)

VENTANAS PARA LA INTEGRACION DE DETECTORES OPTICOS Y TIPO ISFET

5. MICROSISTEMAS DE ANALISIS TOTALTecnología de silicio

[email protected]

ANALIZADOR DE ION PLOMO CON DETECCION POTENCIOMETRICA

MICROSISTEMAS DE ANALISIS TOTAL

Carrier/Sample

Conditioning solution

Cl- solution

Waste

Hydraulic circuit

log (ppmPb2+)

1,5 2,0 2,5 3,0 3,5 4,0 4,5

E (m

V)

10

20

30

40

50

60

70

80

90

E= -69 + 33.log(ppmPb2+ + 367)

Reference electrode

Connections

Ground

ISEGround

a

b

c

d

ISE connection to external set-up

Tecnología LTCC

MICROSISTEMAS DE ANALISIS TOTAL

ANALIZADOR DE ION NITRITO CON DETECCION COLORIMETRICA

2.2cm

2.6c

m

DISPOSITIVO LTCC

Ventana Óptica

Imagen RX

Time (s)

0 20 40 60 80 100 120 140 160 180

Abso

rban

ce

-0,1

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0.1ppm0.5ppm1ppm2ppm5ppm7ppm10ppm

[NO2-] (ppm)

0 2 4 6 8 10 12

AB

SOR

BAN

CIA

0.0

0.5

1.0

1.5

2.0

2.5

Q=5.83µl/svolumen muestray reactivo=29µlRango 0.1-10ppmr2=0.9959

Abs=-3.31·10-3+0.048·[NITRITO]

6. INTEGRATED WAVEGUIDE ABSORBANCE OPTODES ACTIVATED WITH ION-SELECTIVE MEMBRANESIn collaboration with the National Microelectronics Centre of Barcelona (CNM)and the Optical Fibers Group from the University of Zaragoza

input Rib ARROW waveguide 10x4 micronsminimum losses 600-800 nmIsolating cladding

cut waveguide zonecore eliminationmembrane deposition 4 micronsoutput Rib ARROW waveguide50x4 micronsno cladding

[email protected]

7. ELECTROCHEMICAL IMMUNOSENSING BASED ON AFFINITY PLATFORMGraphite-polymer biocomposite

[email protected]

8. ELECTROCHEMICAL IMMUNOSENSING BASED ON mag-GEC

The competitive assay is performed in a solution containing:1.- Antibody modified magnetic particles

2.- Spiked sample

3.- Competitor Tracer (Tx-HRP)

Tx

TX-HRP

TxTxTx-HRPTx-HRP

Magnetic Particles

Size (μm)

Surface Active Group

Antibody Coupling Strategy

MP-COOH 0.196

Covalent Binding

MB-Tosyl

2.8

Covalent Binding

MB-ProtA

2.8

(Protein A)

Affinity Binding

For atrazine determination, specific antibodies were covalently coupled to MB-Tosyl, MP-COOH and MB-ProtA magnetic beads. For sulfonamides specific antibodies, Abs were covalently coupled to MB-Tosyl magnetic beads.

Antibiotics

Pesticides

Pollutants

Antibiotics

Pesticides

Pollutants

[email protected]

Magnetic beads / graphite-polymer composite

AA

CC

BB

M-GEC

streptavidin

biotinylatedprobe

HRP-antiDig

mismatch DNA

digoxigenin probe

magnet

magnetic bead

m-GEC electrode surface

A) Magnetic beads incubations occurs in solution (hybridization of DNA, enzyme or antibody labeling) B) The capture of the modified magnetic beads on the magneto sensor is produced by the magnetic affinity with the magnet inside the sensor body and C) Schematic representation of the electrochemical strategy based on m-GEC electrode.

ne-

HQ

HRP

H2O2H2O

DNA target

AA

CC

BB

M-GEC

streptavidin

biotinylatedprobe

HRP-antiDig

mismatch DNA

digoxigenin probe

magnet

magnetic bead

m-GEC electrode surface

A) Magnetic beads incubations occurs in solution (hybridization of DNA, enzyme or antibody labeling) B) The capture of the modified magnetic beads on the magneto sensor is produced by the magnetic affinity with the magnet inside the sensor body and C) Schematic representation of the electrochemical strategy based on m-GEC electrode.

ne-

HQ

HRP

H2O2H2O

DNA target

33

11 22

44

55

2 µm 10 µm

100 µm50 µm500 µm

33

11 22

44

55

2 µm 10 µm

100 µm50 µm500 µm

Scanning electron microphotographs showing the captured magnetic beads on the surface of m-GEC magneto sensor. Resolution: 2 µm (1), 10 µm (2), 50 µm (3), 100 µm (4) and 500 µm (5). Acceleration voltage: 15 kV.Number of magnetic beads: 6.2 x 106.

ELECTROCHEMICAL IMMUNOSENSING STRATEGY BASED ON mag-GECMagnetic beads / carbon-polymer composite

DIRECT VOLTAMMETRIC DETECTION

PhysicalAdsorption

open circuit

AuIII+ AuIII+AuIII+

Electrochemical oxidation0.1 M HCl

+1.25 V (vs. Ag/AgCl), 120 s

ElectrochemicalReduction

CV (+1.25 V to 0 V)

Cleaning+1.25 V

Au0 Au0

Au0Au0

Au0

M.Pumera, C.Mills, A.Merkoçi, S.Alegret; Electrochimica Acta, 2005, (published in Web )

DIRECT VOLTAMMETRIC DETECTION

PhysicalAdsorption

open circuit

AuIII+ AuIII+AuIII+

Electrochemical oxidation0.1 M HCl

+1.25 V (vs. Ag/AgCl), 120 s

ElectrochemicalReduction

CV (+1.25 V to 0 V)

Cleaning+1.25 V

Au0 Au0

Au0Au0

Au0

M.Pumera, C.Mills, A.Merkoçi, S.Alegret; Electrochimica Acta, 2005, (published in Web )

9. ELECTROCHEMICAL GENOSENSING BASED ON GOLD NANOPARTICLES

[email protected]

(A) introduction of streptavidin coated paramagnetic beads(B) immobilization of the biotinylated probe (DNA2) onto the paramagnetic beads(C) addition of the 1:1 Au67-DNA1 target(D) accumulation of Au67-DNA1/DNA2-paramagnetic bead conjugate on the surface of magnetic electrode(E) magnetically trigged direct DPV electrochemicaldetection of gold quantum dot tag in Au67-DNA1/DNA2-paramagnetic bead conjugate.

Langmuir, 21, 9625-9629 (2005)

Au

A B CAu

AuAu

Au

E

Au

AuAu

AuAu

AuAu

Au

D

DNA2 DNA1

Direct electrochemical detection of magnetically trigged DNA hybridization based Au67 – DNA – paramagnetic bead conjugate

GOLD NANOPARTICLES. Direct electrochemical detection

Au-NPs (Ø < 50 nm) / MBs (Ø < 10 µm)

[email protected]

10. ELECTROCHEMICAL SENSORS BASED ON CARBON NANOTUBESCNT-polymer composite

CNTs as surface modifiers

CNT composites

Carbon nanotubes integration in sensors

, ,

CNTs as surface modifiers

CNT composites

Carbon nanotubes integration in sensors

,

[email protected]

SistemasbiomimèticosSistemasbiomimèticos

11. Matrices de sensores11. Matrices de sensores

Matriz de sensorese-nosee-tongue

[email protected]

Colaboraciones requeridas

Validación interlaboratorios de los prototipos desarrolladosen muestras realesDesarrollo de instrumentación analítica