powerflex 70
-
Upload
palmer-dionicio -
Category
Documents
-
view
231 -
download
0
description
Transcript of powerflex 70
![Page 1: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/1.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
POWER FLEX 70PRIMERO REALIZAMOS LA CONFIGURACION INICIAL AÑADIENDO LOS SLOT :ETHERNET, DEVICENET, RIO
LUEGO ABRIMOS RSNetWorx for Devicenet
CLICK EN ONLINE
1
![Page 2: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/2.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
CLICK EN OK
SE CARGARAN TODOS LOS DISPOSITIVOS ENCONTRADOS POR LA RED DEVICENET
2
![Page 3: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/3.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
AHORA HACEMOS DOBLE CLICK EN POWER FLEX 70, EL CUAL ABRIRA UNA NUEVA VENTANA:
CLICK EN UPLOAD PARA QUE EXTRAIGA LA INFORMACION DEL DISPOSITIVO
LUEGO ACEPTAR.
AHORA NOS VAMOS AL ICONO DE NUESTRO SCANER 1756-DNB
NOS ABRIRA ESTA VENTANA, HACEMOS CLICK EN SCANLIST
CLICK EN UPLOAD
3
![Page 4: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/4.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
NOS APARECE ESTA LISTA DONDE AÑADIMOS EL POWER FLEX 70, FIJENCE QUE ESTE CON UN CHEK donde dice AUTOMAP ON ADD:
LUEGO CLICK EN Output donde nos aparecerá esta información, le damos click en aplicar.
4
![Page 5: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/5.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
AHORA CREAMOS NUESTRO LADER DONDE PONDREMOS NUESTRO START, STOP, HORARIO, ANTIHORARIO EN EL EDIT TAGS
LAS DIRECCIONES SON SEGÚN EL MANUAL DEL POWER FLEX 70
5
![Page 6: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/6.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
CARGAMOS EL LADER Y MODO RUN
REALIZAMOS PRUEBAS CON EL MONITOR TAG.
6
![Page 7: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/7.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
AHORA LO LLEVAREMOS A FACTORYTALK VIEW STUDIO
LOS PASO SON:
NEWS
DISPLAYS, CREAMOS NUESTRO ICONOS
LE DAMOS NOMBRES Y CAMBIAMOS DE COLOR
LUEGO ENTRAMOS A RSLINX ENTERPRISE – CONMUNICATION SETUP
HACEMOS EL COPIADO
LE DAMOS LAS DIRECCIONES CORRESPONDIENTES A NUESTROS ICONOS
LUEGO EL STARTUP DONDE PONEMOS QUE SE INICIE PRIMERO NUESTRA CREACION
GUARDAMOS EL TEST
7
![Page 8: powerflex 70](https://reader035.fdocuments.ec/reader035/viewer/2022081505/55cf857b550346484b8e8684/html5/thumbnails/8.jpg)
Control Industrial Docente: Ing. Manuel Vaca Oliver
TRANSFER UTILITY
APARECERA EN EL PANELVIEW
8