Muro No Portante
description
Transcript of Muro No Portante
DISEO 3DISEO DE MUROS NO PORTANTES (CERCOS)PESO ESPECIFICO DEL CIMIENTO (KG/M3)2,300.00PESO ESPECIFICO DEL SOBRECIMIENTO (KG/M3)2,300.00PESO ESPECIFICO DEL MURO (KG/M3)1,800.00PESO ESPECIFICO DE VIGA DE ARRIOSTRE (KG/M3)2,400.00ANCHO DEL CIMIENTO (M)0.60ANCHO DEL SOBRECIMIENTO (M)0.20ESPESOR DEL MURO (M)0.15ANCHO DE VIGA SOLERA (M)0.25ALTURA DEL CIMIENTO (M)0.80ALTURA DEL SOBRECIMIENTO (M)0.50ALTURA DEL MURO (M)2.20ALTURA DE LA VIGA (M)0.25ALTURA DEL RELLENO (M)1.00POSICION DEL EJE DEL SOBRECIMIENTO EN "X" (M)0.30POSICION DEL EJE DEL MURO EN "X" (M)0.30POSICION DEL EJE DE LA VIGA EN "X" (M)0.30PESO ESPECIFICO DEL TERRENO (KG/M3)1,600.00ANGULO DE FRICCION INTERNA DEL TERRENO21.00CAPACIDAD PORTANTE DEL TERRENO (KG/CM2)0.80DE ACUERDO A LA NORMA E.030 SISMORESISTENTE, PARA OBTENER LAS FUERZAS PERPERDICULARES EN MUROS NO PORTANTESSE UTILIZA LA SIGUIENTE FORMULA :DONDE :Z : FACTOR DE ZONAU : FACTOR USO, DE ACUERDO A LA CATEGORIA DE LA EDIFICACION.C1 : DE ACUERDO AL TIPO DE EDIFICACIONP : PESO PROPIOPARA NUESTRO CASO :Z =0.30ZONA 2U =1.50EDIFICACIONES ESCENCIALESC1 =0.60CALCULO DE LAS FUERZAS PERPENDICULARES "V" DE CADA ELEMENTO :CIMIENTO :Pc =0.00KGVc =0.00KGYc =0.00m.SOBRECIMIENTO :Ps/c =138.00KGVs/c =37.26KGYs/c =1.15m.MURO :Pm =594.00KGVm =160.38KGYm =2.40m.VIGA ARRIOSTRE :Pv =150.00KGVv =40.50KGYv =3.63m.CALCULO DEL EMPUJE ACTIVO DEL TERRENO :0.4724377.8841KGYa =0.33m.CALCULO DEL EMPUJE PASIVO DEL TERRENO :2.11711,693.6410KGYa =0.33m.CALCULO DE LAS FUERZAS VERTICALES ACTUANTES :Pi (Tn)Xi (m)Mi (Tn-m)Pc1.10400.30000.3312Ps/c0.23000.30000.0690Pm0.59400.30000.1782Pv0.15000.30000.0450Total2.07800.6234LA POSICION DE LA RESULTANTE DE LAS CARGAS VERTICALES EN "X" ES :0.300m.AHORA TRASLADANDO LA RESULTANTE AL CENTRO DE PRESIONES :2.078Tn-0.000Tn-mHORARIOCALCULO DEL MOMENTO GENERADO POR LAS FUERZAS HORIZONTALES :SE CONSIDERA POSITIVO EN SENTIDO ANTIHORARIO0.136Tn-mANTIHORARIOCALCULO DE LA EXCENTRICIDAD :0.065m.OK SE ENCUENTRA EN EL TERCIO CENTRALCALCULO DE LOS ESFUERZOS EN EL TERRENO :0.573KG/CM2OK0.120KG/CM2OKVERIFICACION POR DESLIZAMIENTO Y VOLTEO :CHEQUEO AL VOLTEO :FSV =2.068OKCHEQUEO AL DESLIZAMIENTO :FSD =1.504OK
MBD00044739.unknown
MBD00044741.unknown
MBD00044745.unknown
MBD00044747.unknown
MBD00044748.unknown
MBD00044746.unknown
MBD00044743.unknown
MBD00044744.unknown
MBD00044742.unknown
MBD0004473D.unknown
MBD0004473F.unknown
MBD00044740.unknown
MBD0004473E.unknown
MBD0004473B.unknown
MBD0004473C.unknown
MBD0004473A.unknown
MBD00044731.unknown
MBD00044735.unknown
MBD00044737.unknown
MBD00044738.unknown
MBD00044736.unknown
MBD00044733.unknown
MBD00044734.unknown
MBD00044732.unknown
MBD0004472D.unknown
MBD0004472F.unknown
MBD00044730.unknown
MBD0004472E.unknown
MBD00044729.unknown
MBD0004472B.unknown
MBD0004472C.unknown
MBD0004472A.unknown
MBD00044727.unknown
MBD00044728.unknown
MBD00044725.unknown
MBD00044726.unknown
MBD00044722.unknown