LAS 10-15 MT 22TT

download LAS 10-15 MT 22TT

of 44

Transcript of LAS 10-15 MT 22TT

  • 7/29/2019 LAS 10-15 MT 22TT

    1/44

    Montage- undGebrauchsanweisung Deut

    sch

    English

    FranaisInstructions dinstallation

    et dutilisation

    Installation andOperating Instructions

    Luft/Wasser-Wrmepumpe frSchwimmbad-erwrmung zur

    Auenaufstellung

    LAS 10MT

    LAS 15MT

    LAS 22TT

    Air-to-WaterHeat Pumps forSwimming PoolHeating (Outdoor

    Installation)

    Chauffage depiscine parpompe chaleurair/eau monte

    lextrieur

    Bestell-Nr. / Order no. / No de commande : 452159.66.11 FD 8812

  • 7/29/2019 LAS 10-15 MT 22TT

    2/44

  • 7/29/2019 LAS 10-15 MT 22TT

    3/44

    www.dimplex.de D-1

    Deut

    sch

    Inhaltsverzeichnis

    1 Bitte sofort lesen .......................................................................................................................... D-2

    1.1 Wichtige Hinweise ..................................................................................................................................D-2

    1.2 Bestimmungsgemer Gebrauch...........................................................................................................D-2

    1.3 Gesetzliche Vorschriften und Richtlinien ................................................................................................D-2

    1.4 Energiesparende Handhabung der Wrmepumpe.................................................................................D-2

    2 Verwendungszweck der Wrmepumpe...................................................................................... D-3

    2.1 Anwendungsbereich ...............................................................................................................................D-3

    2.2 Arbeitsweise ...........................................................................................................................................D-3

    2.3 Projektierung Schwimmbad-Wrmepumpe ............................................................................................D-3

    3 Lieferumfang................................................................................................................................. D-4

    3.1 Grundgert..............................................................................................................................................D-4

    3.2 Schaltkasten ...........................................................................................................................................D-4

    4 Transport....................................................................................................................................... D-4

    5 Aufstellung.................................................................................................................................... D-4

    5.1 Allgemein................................................................................................................................................D-4

    5.2 Kondensatleitung....................................................................................................................................D-5

    6 Montage......................................................................................................................................... D-5

    6.1 Allgemein................................................................................................................................................D-5

    6.2 Schwimmbadseitiger Anschluss .............................................................................................................D-5

    6.3 Elektrischer Anschluss............................................................................................................................D-5

    7 Inbetriebnahme............................................................................................................................. D-6

    7.1 Allgemein................................................................................................................................................D-6

    7.2 Inbetriebnahme.......................................................................................................................................D-6

    8 Funktionsbeschreibung............................................................................................................... D-6

    8.1 Fernversteller-Wrmepumpe..................................................................................................................D-6

    8.2 Steuerplatine...........................................................................................................................................D-7

    8.3 Funktion Heizen......................................................................................................................................D-7

    9 Reinigung / Pflege ........................................................................................................................ D-7

    9.1 Pflege......................................................................................................................................................D-7

    9.2 Reinigung Leitungssystem Wrmetauscher ...........................................................................................D-7

    9.3 Reinigung Luftseite .................................................................................................................................D-7

    9.4 Winterstilllegung / berwinterung...........................................................................................................D-89.5 Wartung ..................................................................................................................................................D-8

    10 Strungen / Fehlersuche ............................................................................................................. D-8

    11 Auerbetriebnahme / Entsorgung .............................................................................................. D-8

    12 Gerteinformation ........................................................................................................................ D-9

    13 Garantieurkunde......................................................................................................................... D-10

    Anhang / Appendix / Annexes ............................................................................................................ A-I

  • 7/29/2019 LAS 10-15 MT 22TT

    4/44

    D-2

    1

    1 Bitte sofort lesen

    1.1 Wichtige Hinweise

    ACHTUNG!Die Wrmepumpe darf beim Transport nur bis zu einer Neigung von 45

    (in jeder Richtung) gekippt werden.

    ACHTUNG!Wrmepumpe und Transportpalette sind nur durch die Verpackungsfolieverbunden.

    ACHTUNG!Der Ansaug- und Ausblasbereich darf nicht eingeengt oder zugestelltwerden.

    ACHTUNG!Rechtsdrehfeld (bei mehrphasigen Gerten) beachten: Bei Betrieb desVerdichters mit falscher Drehrichtung kann es zu Verdichterschdenkommen. Eine falsche Phasenfolge bewirkt eine falsche Drehrichtungdes Ventilators und damit verbunden eine deutlicheLeistungsminderung.

    ACHTUNG!Die Wrmepumpe darf nicht ohne Wasserdurchsatz betrieben werden!

    ACHTUNG!Der Strmungswchter muss auf den erforderlichen Volumenstromausgelegt sein und ein permanentes Durchschalten gewhrleisten.

    ACHTUNG!Verwenden Sie nie sand-, soda-, sure- oder chloridhaltige Putzmittel, dadiese die Oberflche angreifen.

    ACHTUNG!Vor ffnen des Gertes ist sicherzustellen, dass alle Stromkreisespannungsfrei geschaltet sind.

    ACHTUNG!Schden durch falsche berwinterung sind von der Garantieausgeschlossen.

    ACHTUNG!Arbeiten am Kltekreis drfen nur von fachkundigen Personendurchgefhrt werden.

    1.2 BestimmungsgemerGebrauch

    Dieses Gert ist nur fr den vom Hersteller vorgesehenen Ver-wendungszweck freigegeben. Ein anderer oder darber hinausgehender Gebrauch gilt als nicht bestimmungsgem. Dazuzhlt auch die Beachtung der zugehrigen Produktschriften. n-

    derungen oder Umbauten am Gert sind zu unterlassen.

    1.3 Gesetzliche Vorschriften undRichtlinien

    Bei der Konstruktion und Ausfhrung der Wrmepumpe wurdenalle entsprechenden EG-Richtlinien, DIN- und VDE-Vorschrifteneingehalten (siehe CE-Konformittserklrung).

    Beim elektrischen Anschluss der Wrmepumpe sind die entspre-chenden VDE-, EN- und IEC-Normen einzuhalten. Auerdemmssen die Anschlussbedingungen der Versorgungsnetzbetrei-ber beachtet werden.

    Beim wasserseitigen Anschluss sind die einschlgigen Vorschrif-ten einzuhalten.

    Personen, insbesondere Kinder, die aufgrund ihrer physischen,sensorischen oder geistigen Fhigkeiten oder ihrer Unerfahren-heit oder Unkenntnis nicht in der Lage sind, das Gert sicher zubenutzen, sollten dieses Gert nicht ohne Aufsicht oder Anwei-sung durch eine verantwortliche Person benutzen.

    Kinder sollten beaufsichtigt werden, um sicherzustellen, dass sienicht mit dem Gert spielen.

    1.4 Energiesparende Handhabungder Wrmepumpe

    Besonders wichtig fr die Effektivitt einer Wrmepumpe ist es,die Temperaturdifferenz zwischen Warmwasser und Wrme-quelle mglichst gering zu halten.

    Angepasste Heizwassertemperaturen, eine gezielte Wahl desStandortes des Freibeckens und der Einsatz von wrmeisolie-renden Poolabdeckungen sind nur einige Manahmen, um denHeizenergiebedarf zustzlich zu senken.

    Whrend des Betriebes ist es wichtig, dass keine Verunreinigun-gen der Wrmetauscher auftreten, weil dadurch die Temperatur-differenz erhht und damit die Leistungszahl verschlechtert wird.

  • 7/29/2019 LAS 10-15 MT 22TT

    5/44

    www.dimplex.de D-3

    Deut

    sch

    2.3

    2 Verwendungszweck der

    Wrmepumpe

    2.1 AnwendungsbereichDie Schwimmbad-Wrmepumpe ist fr die Erwrmung von

    Schwimmbadwasser oder salzhaltigem Wasser geeignet.Die Wrmepumpe ist mit einer automatischen Abtaueinrichtung(Enteisung) des Verdampfers ausgestattet. Der Wrmepumpen-betrieb ist unter Beachtung der Einsatzgrenzen und Einsatzbe-dingungen auch bei frostigen Auenlufttemperaturen mglich.

    2.2 ArbeitsweiseUmgebungsluft wird vom Ventilator angesaugt und dabei bereinen Lamellenwrmetauscher geleitet, der der Luft Wrme ent-zieht. Diese Energiedifferenz wird im Wrmetauscher auf das Ar-beitsmedium (Kltemittel) bertragen.

    Mit Hilfe eines elektrisch angetriebenen Verdichters wird aufge-

    nommene Wrme durch Druckerhhung auf ein hheres Tempe-raturniveau gepumpt und ber den Titanwrmeaustauscher andas Wasser abgegeben.

    Im Heizbetrieb wird die elektrische Antriebsenergie eingesetzt,um die Wrme der Umwelt auf ein hheres Temperaturniveauanzuheben. Da die der Luft entzogene Energie auf das zu erwr-mende Wasser bertragen wird, bezeichnet man dieses Gertauch als Luft-Wasser-Wrmepumpe.

    Die Schwimmbad-Wrmepumpe speziell besteht aus den Haupt-bauteilen Verdampfer, Ventilator und Expansionsventil, sowiedem geruscharmen Verdichter, dem Verflssiger (Titanwrme-tauscher) und der elektrischen Steuerung.

    Im Heizbetrieb lagert sich bei tiefen UmgebungstemperaturenLuftfeuchtigkeit als Reif auf dem Verdampfer an und verschlech-tert die Wrmebertragung. Der Verdampfer wird nach Bedarfautomatisch abgetaut. Je nach Witterung knnen dabei bei Wie-deranlauf kurzzeitig Dampfschwaden (Wasserdampf) amLuftaus- oder Lufteintrittsbereich sichtbar werden.

    2.3 Projektierung Schwimmbad-Wrmepumpe

    FreibadDer Wrmebedarf fr eine Schwimmbeckenwasser-Erwrmungim Freibad hngt stark von den Nutzungsgewohnheiten ab.

    Er kann grenordnungsmig dem Wrmebedarf einesWohnhauses entsprechen und ist in solchen Fllen gesondert zuberechnen.

    Die berschlgige Ermittlung des Wrmebedarfs ist abhngigvon Windlage des Beckens, der Beckentemperatur, den klimati-schen Bedingungen, der Nutzungsperiode und ob eine Abde-ckung der Beckenoberflche vorliegt.

    Anhaltswerte fr den Wrmebedarf von Freibdern bei einerNutzung von Mai bis September

    Fr die Erstaufheizung des Beckens auf eine Temperatur vonber 20 C ist eine Wrmemenge von ca. 12 kWh/m3 Beckenin-halt erforderlich. Je nach Beckengre und installierter Heizleis-tung sind damit Aufheizzeiten von ein bis drei Tage erforderlich.

    Hallenbad Raumheizung

    Die Raumheizung erfolgt im allgemeinen ber eine Radiato-ren- oder Fubodenheizung und/oder ein Heizungsregisterin der Entfeuchtungs-/Belftungsanlage. In beiden Fllen isteine Wrmebedarfsberechnung je nach technischer L-sung notwendig.

    Schwimmbeckenwasser-ErwrmungDer Wrmebedarf hngt von der Beckenwassertemperatur,der Temperaturdifferenz zwischen Beckenwasser undRaumtemperatur sowie der Nutzung des Schwimmbadesab.

    Anhaltswerte fr den Wrmebedarf von Hallenbdern

    Bei privaten Schwimmbdern mit einer Abdeckung des Beckensund einer Nutzung von max. 2 Stunden pro Tag knnen dieseLeistungen um bis zu 50 % verringert werden.

    Wassertemperatur

    20 C 24 C 28 C

    mit Abdeckung1

    1. Verminderte Werte fr Becken mit Abdeckung gelten nur bei privatenSchwimmbdern bei einer Nutzung von bis 2h pro Tag.

    100 W/m2 150 W/m2 200 W/m2

    ohne AbdeckungLage geschtzt 200 W/m

    2 400 W/m2 600 W/m2

    ohne AbdeckungLage teilgeschtzt 300 W/m

    2 500 W/m2 700 W/m2

    ohne Abdeckungungeschtzt (wind-stark)

    450 W/m2 800 W/m2 1000 W/m2

    RaumtemperaturWassertemperatur

    20 C 24 C 28 C

    23 C 90 W/m2 165 W/m2 265 W/m2

    25 C 65 W/m2 140 W/m2 240 W/m2

    28 C 20 W/m2 100 W/m2 195 W/m2

  • 7/29/2019 LAS 10-15 MT 22TT

    6/44

    D-4

    3

    3 Lieferumfang

    3.1 GrundgertDie Wrmepumpe wird in Kompaktbauweise geliefert und enthltunten aufgefhrte Bauteile.

    Der Kltekreis enthlt das vom Kyoto-Protokoll erfasste fluorierteKltemittel R407C mit einem GWP-Wert von 1525. Es ist FCKW-frei, baut kein Ozon ab und ist nicht brennbar.

    1) Verdampfer

    2) Schaltkasten

    3) Ventilator

    4) Filtertrockner

    5) Verdichter

    6) Titanwrmetauscher

    (Abbildung: Gehusefassadierung demontiert)

    3.2 SchaltkastenDer Schaltkasten befindet sich in der Wrmepumpe und ist nach

    Abnahme des davorliegenden Verkleidungsbleches zugnglich(die Schraubenbefestigungslcher der Verkleidungsbleche sindmit Abdeckkappen verschlossen).

    Im Schaltkasten befinden sich die Netzanschlussklemmen, dieLeistungsschtze, die Sanftanlauf-Einheit und die Anschluss-klemmen fr den Fernversteller.

    Die Steuerung der Wrmepumpe erfolgt ber den im Lieferum-fang enthaltenen Fernversteller (siehe hierzu auch Punkt 8).

    4 Transport

    ACHTUNG!Die Wrmepumpe darf beim Transport nur bis zu einer Neigung von 45(in jeder Richtung) gekippt werden.

    Der Transport zum endgltigen Aufstellungsort sollte mit dem

    Holzrost erfolgen. Die Wrmepumpe kann mit einem Hubwagen,oder mittels 3/4"-Rohren, die durch Bohrungen in der Grund-platte bzw. im Rahmen gefhrt werden, transportiert werden.

    ACHTUNG!Wrmepumpe und Transportpalette sind nur durch die Verpackungsfolieverbunden.

    Bei der Verwendung von Tragrohren ist darauf zu achten, dassdiese gegen Verschieben gesichert werden mssen, um Verlet-zungen (der Hnde) whrend des Transportierens zu vermeiden!

    Beim Durchstecken der Tragrohre durch den Rahmen ist daraufzu achten, dass keine Bauteile (insbesondere die Kunststoffkon-densatwanne bzw. der Ablaufstutzen) beschdigt werden.

    5 Aufstellung

    5.1 AllgemeinDas Gert ist grundstzlich auf einer dauerhaft ebenen, glattenund waagerechten Flche aufzustellen. Dabei sollte der Rahmen(mit seinen Auflageflchen) vollflchig am Boden anliegen, umeiner evtl. Krperschallentwicklung entgegen zu wirken. Ist diesnicht mglich, knnten zustzliche bauseitige Manahmen zurSchalldmmung notwendig werden. Wartungsarbeiten mssen

    problemlos durchgefhrt werden knnen. Dies ist gewhrleistet,wenn ein Abstand von 1,2 m um das Gert eingehalten wird.

    ACHTUNG!Der Ansaug- und Ausblasbereich darf nicht eingeengt oder zugestelltwerden.

    )UHLH$XVEODVULFKWXQJ

  • 7/29/2019 LAS 10-15 MT 22TT

    7/44

    www.dimplex.de D-5

    Deut

    sch

    6.3

    5.2 KondensatleitungDas im Betrieb anfallende Kondensatwasser muss frostfrei ab-geleitet werden. Um einen einwandfreien Abfluss zu gewhrleis-ten, muss die Wrmepumpe waagerecht stehen. Das Konden-satwasserrohr muss mindestens einen Durchmesser von 50 mmhaben und muss frostsicher in den Abwasserkanal oder in eineausreichend dimensionierte und tief gelegte Kiessickergrube ge-

    fhrt werden.

    Das Kondensatrohr ist zentrisch unter dem Ablaufstutzen derKondensatwanne zu platzieren (siehe auch Mabild im Anhang).

    Alternative Kondensatabfhrungen sind mit dem Hersteller zuvereinbaren.

    Kondensat nicht direkt in Klrbecken und Gruben einleiten, daaufsteigende aggressive Dmpfe den Verdampfer zerstrenknnen.

    6 Montage

    6.1 AllgemeinAn der Schwimmbad-Wrmepumpe sind folgende Anschlsseherzustellen:

    Vor-/Rcklufe der Schwimmbadanlage

    Kondensatablauf

    Steuerleitung zum Fernversteller

    Stromversorgung

    Steuerleitung zu bauseitigem Freigabekontakt (potentialfrei)

    6.2 Schwimmbadseitiger

    AnschlussDie wasserseitigen Anschlsse an der Wrmepumpe sind mit 1"-bzw. 1 1/2"-Auengewinde versehen. Beim Anschluss an dieWrmepumpe muss an den bergngen mit einer Rohrzangegegengehalten werden.

    Der wasserseitige Anschluss erfolgt ber einen Bypass am Fil-terkreislauf des Schwimmbeckens hinter dem Filter und vor derWasseraufbereitung. Bei Anschluss von Kunststoffrohren solltengeeignete Temperaturmessstellen direkt an den Vorlauf- undRcklaufanschlssen der Schwimmbadwrmepumpe vorgese-hen werden (z. B. Tauchhlsen).

    Bevor die wasserseitigen Anschlsse der Wrmepumpe erfol-gen, muss das Schwimmbadwassersystem gesplt werden, umeventuell vorhandene Verunreinigungen, Reste von Dichtmate-rial oder hnliches zu entfernen. Es wird dringend empfohlen, imWasserkreislauf eine Filteranlage zu installieren. Ein Ansam-meln von Rckstnden (Bltter, Gras und andere organischeoder anorganischer Verunreinigungen) im Verflssiger knnenzum Totalausfall der Wrmepumpe fhren. Durch eine geeignetehydraulische Einbindung und Einregulierung sowie Bemessungder Filter-/Umwlzpumpe ist fr einen strungsfreien Betrieb derMindestwasserdurchsatz durch die Wrmepumpe zu gewhr-leisten.

    Nach erstellter wasserseitiger Installation ist die Anlage zu fllen,zu entlften und abzudrcken.

    MindestwasserdurchsatzDie Schwimmbad-Wrmepumpe enthlt keine eigene Umwlz-pumpe. Der bentigte Wasserdurchsatz muss durch eine ex-terne Filterpumpe sichergestellt werden und der Wrmepumpeber den entsprechenden Eingang rckgemeldet werden.

    ACHTUNG!

    Die Wrmepumpe darf nicht ohne Wasserdurchsatz betrieben werden!

    FrostschutzBei Wrmepumpen, die frostgefhrdet aufgestellt sind, musseine manuelle Entleerung (siehe Anhang Hydraulische Prinzip-schemen) vorgesehen werden. Fr die Sicherung der Frost-schutzfunktion ist bei Lufttemperaturen unterhalb 5 C ein Dau-erlauf der Filterpumpe bauseitig sicherzustellen (z.B. durcheinen Frostschutz-Thermostaten) (siehe Hinweise Kap. 9.4Winterstilllegung / berwinterung).

    6.3 Elektrischer AnschlussDer Leistungsanschluss der Wrmepumpe erfolgt je nach Ger-

    tetyp ber ein handelsbliches 3-adriges (Gerte 1-phasig) bzw.5-adriges (Gerte 3-phasig) Kabel.

    Das (die) Kabel ist (sind) bauseits beizustellen und der Leitungs-querschnitt gem der Leistungsaufnahme der Wrmepumpe(siehe Anhang Gerteinformation) sowie der einschlgigen VDE-(EN-) und VNB-Vorschriften zu whlen.

    In der Leistungsversorgung fr die Wrmepumpe ist eine allpo-lige Abschaltung mit mindestens 3 mm Kontaktffnungsabstand(z.B. EVU-Sperrschtz, Leistungsschtz), sowie ein 3-poligerbzw. 1-poliger (Gerte 1~) Sicherungsautomat, mit gemeinsa-mer Auslsung aller Auenleiter, vorzusehen (Auslsestromgem Gerteinformation).

    Beim Anschlieen der mehrphasigen Gerte ist das Rechtsdreh-feld der Lasteinspeisung sicherzustellen.

    Phasenfolge: L1, L2, L3.

    ACHTUNG!Rechtsdrehfeld (bei mehrphasigen Gerten) beachten: Bei Betrieb desVerdichters mit falscher Drehrichtung kann es zu Verdichterschdenkommen. Eine falsche Phasenfolge bewirkt eine falsche Drehrichtungdes Ventilators und damit verbunden eine deutlicheLeistungsminderung.

    Die Steuerspannung fr den Fernversteller wird durch die Span-nungsversorgung am Gert bereitgestellt.

    Die Verbindungsleitung (Steuerleitung) vom Fernversteller zur

    Wrmepumpe (nicht im Lieferumfang) muss fr die Netzspan-nung von 230 V geeignet sein. Die Leitung muss (mindestens)5-adrig sein und ber einen Einzeladerquerschnitt von min.0,5 mm verfgen.

    Die Verbindungsleitung von der Wrmepumpe zu einem bausei-tigen Freigabekontakt muss fr die Netzspannung von 230 V ge-eignet sein.

    Die Wrmepumpe hat keine eigene Umwlzpumpe. Der ben-tigte Wasserdurchsatz muss durch eine externe Filterpumpe si-chergestellt und der Wrmepumpe ber den entsprechendenEingang zurckgemeldet werden. Hierfr sind die Klemmen 2und 3 der Klemmleiste X2 zu verwenden. Die Freigabe erfolgtber einen bauseitigen, potentialfreien Kontakt (K29).

    ACHTUNG!Der Strmungswchter muss auf den erforderlichen Volumenstromausgelegt sein und ein permanentes Durchschalten gewhrleisten.

  • 7/29/2019 LAS 10-15 MT 22TT

    8/44

    D-6

    7

    Die Stromversorgung der Wrmepumpe erfolgt entsprechendden Technischen Daten des Gertes mit 1/N/PE ~ 230 V, 50 Hzoder 3/N/PE ~ 400 V, 50 Hz.

    Der Anschluss in der Wrmepumpe erfolgt ber die Klemmleis-ten im Schaltkasten. Detaillierte Informationen siehe AnhangStromlaufplne.

    7 Inbetriebnahme

    7.1 AllgemeinUm eine ordnungsgeme Inbetriebnahme zu gewhrleisten,sollte diese von einem vom Werk autorisierten Kundendienstdurchgefhrt werden. Nur dann wird eine verlngerte Garantievon insgesamt 3 Jahren gewhrt (vgl. Garantieleistung).

    7.2 InbetriebnahmeVor der Inbetriebnahme mssen folgende Punkte geprft wer-

    den:

    Alle Anschlsse der Wrmepumpe mssen, wie in Kapitel 6beschrieben, montiert sein.

    Im Wasserkreislauf mssen alle evtl. vorhandenen Absperr-organe, die den korrekten Fluss des Wassers behindernknnten, geffnet sein.

    Der Luftansaug-/-ausblasweg muss frei sein.

    Die Drehrichtung des Ventilators muss der Pfeilrichtung ent-sprechen.

    Der Fernversteller muss betriebsbereit eingestellt sein.

    Der Kondensatablauf muss sichergestellt sein.

    Nach dem Anlegen der Betriebsspannung bzw. dem Ein-

    schalten der Schwimmbad-Wrmepumpe ist eine betriebs-bedingte Verdichterstillstandszeit von 5 Minuten bis zum

    Anlauf der Wrmepumpe vorprogrammiert.

    Die Bypass- und Regulierventile mssen so eingestellt sein,dass der Mindestwasserdurchfluss gem Gerteinforma-tion sichergestellt ist. Im Betriebspunkt stellen sich nachfol-gende maximale Temperaturspreizungen zwischen Wasse-rein- und -austritt ein.

    8 Funktionsbeschreibung

    8.1 Fernversteller-WrmepumpeMit dem im Gebudeinneren (frostfrei und trocken) platziertenFernversteller kann die Wrmepumpe ein- und ausgeschaltetwerden. Bei Wassertemperaturen

  • 7/29/2019 LAS 10-15 MT 22TT

    9/44

    www.dimplex.de D-7

    Deut

    sch

    9.3

    8.2 Steuerplatine

    8.3 Funktion HeizenMit Schalter (1) auf Stellung Ein (I) wird die Wrmepumpe in Be-triebe genommen. Die gewnschte Rcklauftemperatur wirdber Drehknopf (4) eingestellt, die Anforderung hierzu erfolgtber das Potentiometer und liegt im Bereich zwischen min. 10 Cund max. 40 C. Wird die eingestellte Temperatur erreicht, schal-tet die Wrmepumpe aus, sinkt die Rcklauftemperatur um1 Kelvin unter den eingestellten Wert, schaltet die Wrmepumpewieder ein. Eine Wiedereinschaltung der Wrmepumpe ist erstnach einer Mindeststandzeit von 20 Minuten (nach einem Abtau-vorgang im Verdampfer) mglich. Bei einer maximalen Vorlauf-temperatur von ca. 45 C, bzw. bei zu niedriger Lufttemperatur(untere Einsatzgrenze -10 C) schaltet die Wrmepumpe aus.

    9 Reinigung / Pflege

    9.1 PflegeVermeiden Sie zum Schutz des Lackes das Anlehnen und Able-gen von Gegenstnden am und auf dem Gert. Die Auenteileder Wrmepumpe knnen mit einem feuchten Tuch und mit han-

    delsblichen Reinigern abgewischt werden.

    ACHTUNG!Verwenden Sie nie sand-, soda-, sure- oder chloridhaltige Putzmittel, dadiese die Oberflche angreifen.

    Um Strungen durch Schmutzablagerungen im Titanwrme-austauscher der Wrmepumpe zu vermeiden, ist dafr zu sor-gen, dass der Wrmeaustauscher in der Wrmepumpe nicht ver-schmutzen kann (Wasseraufbereitung bzw. Filteranlage isterforderlich). Sollte es dennoch zu Betriebsstrungen wegenVerschmutzungen kommen, ist die Anlage wie unten angegebenzu reinigen. (Achtung die Lamellen des Rippenrohrtauscherssind scharfkantig -> Schnittverletzungsgefahr!)

    9.2 Reinigung LeitungssystemWrmetauscher

    Verunreinigungen im Leitungssystem bzw. im Wrmetauscherknnen dazu fhren, dass sich die Leistungsfhigkeit des Titan-wrmetauschers der Wrmepumpen verringert. Ist dies der Fall,muss die Reinigung vom Leitungssystem und Wrmetauscherdurch den Installateur durchgefhrt werden.

    Die Reinigung sollte nur mit druckbeaufschlagtem Trinkwassererfolgen.

    9.3 Reinigung LuftseiteLamellenwrmetauscher, Lfter und Kondensatablauf sind vorder Heizperiode von Verunreinigungen (Bltter, Zweige usw.) zureinigen. Verunreinigungen dieser Art knnen manuell mit Druck-luft oder durch Absplen mit klarem Wasser beseitigt werden.

    Erforderlichenfalls sind der Gertedeckel und das Luftansaug-gitter hierfr zu entfernen.

    ACHTUNG!Vor ffnen des Gertes ist sicherzustellen, dass alle Stromkreisespannungsfrei geschaltet sind.

    Die Verwendung von scharfen und harten Gegenstnden ist beider Reinigung zu vermeiden, um eine Beschdigung am Ver-dampfer und der Kondensatwanne zu verhindern.

    Bei extremen Witterungsbedingungen (z.B. Schneeverwehun-gen) kann es vereinzelt zu Eisbildung an den Ansaug- und Aus-blasgittern kommen. Um den Mindestluftdurchsatz sicherzustel-len, ist in diesem Fall der Ansaug- und Ausblasbereich von Eisund Schnee zu befreien.

    / EOLQNWEHL%HWULHE

    / QLFKWEHQXW]W

    / EOLQNWEHL6W|UXQJURW

    ', QLFKWEHQXW]W

    ', QLFKWEHQXW]W

    ', QLFKWEHQXW]W

    ', HLQ)LOWHUSXPSHHLQXQG+RFKGUXFNSUHVVRVWDWLQ2UGQXQJ

    '2 HLQ9HUGLFKWHUXQG9HQWLODWRUODXIHQ

    '2 QLFKWEHQXW]W

    '2 $EWDXKHL]XQJDXV+HL]HQHLQ$EWDXXQJ

    '2 QLFKWEHQXW]W

    '2 QLFKWEHQXW]W

    '2 HLQ)URVWVFKXW]DQIRUGHUXQJ

    '2 QLFKWEHQXW]W

    '2 QLFKWEHQXW]W

    ',QLFKWEHQXW]W', QLFKWEHQXW]W

    ', HLQ1LHGHUGUXFNSUHVVRVWDWLQ2UGQXQJ

    ', QLFKWEHQXW]W

    ', QLFKWEHQXW]W

    ', QLFKWEHQXW]W

    /

    /

    /

    ',

    ',

    ',

    ',

    '2 '2 '2 '2 '2

    '2

    '2

    '2

    ',

    ',

    ',

    ',

    ',

    ',

  • 7/29/2019 LAS 10-15 MT 22TT

    10/44

    D-8

    9.4

    9.4 Winterstilllegung /berwinterung

    Bei Frostgefahr auerhalb der Badesaison und abgeschalteterSchwimmbadheizung sowie bei zu erwartenden Auentempera-turen unterhalb der Einsatzgrenze ist vorbeugend der Wasser-kreislauf der Wrmepumpe vllig zu entleeren oder durch geeig-

    nete bauseitige Manahmen die Wrmepumpe vorFrostschden zu schtzen.

    ACHTUNG!Schden durch falsche berwinterung sind von der Garantieausgeschlossen.

    9.5 WartungGem der Verordnung (EG) Nr. 842/2006 mssen alle Klte-kreise, die eine Kltemittelfllmenge von mindestens 3 kg, beihermetisch geschlossenen Kltekreisen von mindestens 6 kgenthalten, einmal jhrlich durch den Betreiber auf Dichtheit ge-prft werden.

    10 Strungen / FehlersucheDiese Wrmepumpe ist ein Qualittsprodukt und sollte strungs-und wartungsfrei arbeiten. Tritt dennoch eine Strung auf, ber-prfen Sie anhand der folgenden Hinweise, ob Sie die Strungselbst beheben knnen.

    Die Wrmepumpe luft nicht!

    Bitte berprfen Sie, ob: die Spannungsversorgung sichergestellt ist (Sicherung aus-

    gelst, Stromausfall).

    der Betriebsschalter an der Fernbedienung eingeschaltenist, sowie die richtige Sollwerttemperatur eingestellt ist.

    Das eingestellte Temperaturniveau wird nicht erreicht!Bitte berprfen Sie, ob

    die zulssigen Betriebsbedingungen der Wrmepumpe ein-gehalten werden (zu hohe oder zu tiefe Lufttemperaturen).

    der Luftansaug- oder Ausblasbereich verdeckt, eingeengtoder stark verschmutzt ist.

    in den Wasserleitungen Ventile oder Absperrhhne ge-

    schlossen sind.Wenn die Strung nicht selbst behoben werden kann, verstndi-gen Sie bitte den zustndigen Kundendienst (siehe Garantieur-kunde).

    Arbeiten an der Wrmepumpe drfen nur vom autorisierten undfachkundigen Kundendienst durchgefhrt werden.

    11 Auerbetriebnahme /

    EntsorgungBevor die Wrmepumpe ausgebaut wird, ist die Maschine span-

    nungsfrei zu schalten und abzuschiebern. Umweltrelevante An-forderungen, in Bezug auf Rckgewinnung, Wiederverwendungund Entsorgung von Betriebsstoffen und Bauteilen gem dengngigen Normen, sind einzuhalten. Dabei ist besonders Wertauf eine fachgerechte Entsorgung des Kltemittels und Klteleszu legen.

  • 7/29/2019 LAS 10-15 MT 22TT

    11/44

    www.dimplex.de D-9

    Deut

    sch

    12

    12 Gerteinformation

    1 Typ- und Verkaufsbezeichnung LAS 10MT LAS 15MT LAS 22TT

    2 Bauform

    2.1 Schutzart nach EN 60 529 fr Kompaktgert bzw. Heizteil IP 24 IP 24 IP 24

    2.2 Aufstellungsort Auen Auen Auen

    3 Leistungsangaben3.1 Temperatur-Betriebseinsatzgrenzen:

    Beckenwasser-Vorlauf / -Rcklauf1 C / C

    1. siehe Einsatzgrenzendiagramm

    bis 40 / ab 10 bis 40 / ab 10 bis 40 / ab 10

    Luft C -10 bis +35 -10 bis +35 -10 bis +35

    3.2 Wrmeleistung / Leistungszahl bei A20 / W24 2 kW / -

    2. Diese Angaben charakterisieren die Gre und die Leistungsfhigkeit der Anlage. Fr wirtschaftliche und energetische Betrachtungen sind weitere Einflussgren, insbesondereAbtauverhalten, Bivalenzpunkt und Regelung zu bercksichtigen. Dabei bedeuten z.B. A20 / W24: Auenlufttemperatur 20C und Schwimmbadvorlau ftemperatur 24 C.

    12,1 / 4,2 16,6 / 4,7 22,3 / 5,1

    3.3 Schall-Leistungspegel dB(A) 70 70 71

    3.4 Schall-Druckpegel in 10 m Entfernung (Ausblasseite) dB(A) 45 45 46

    3.5 Beckenwasserdurchfluss bei interner Druckdifferenz m/h / Pa 1,6 / 7200 2,0 / 12000 2,5 / 8000

    3.6 Kltemittel; Gesamt-Fllgewicht Typ / kg R407C / 1,5 R407C / 1,6 R407C / 2,5

    3.7 Schmiermittel; Gesamt-Fllmenge Typ / Liter FV68S / 1,7 FV68S / 1,7 FV68S / 1,7

    3.8 El. Leistung der Abtauheizung kW 1,8 2,4 3,0

    4 Abmessungen, Anschlsse und Gewicht4.1 Gerteabmessungen H x B x L cm 86 x 127 x 67 86 x 127 x 67 86 x 127 x 67

    4.2 Gerteanschlsse fr Heizung Zoll G 1'' auen G 1'' auen G 1 1/2'' auen

    4.3 Gewicht der Transporteinheit(en) incl. Verpackung kg 147 155 162

    5 Elektrischer Anschluss

    5.1 Nennspannung; Absicherung V / A 230 / 20 230 / 25 400 / 16

    5.2 Nennaufnahme 2 A15 / W32 kW 3,3 4,0 5,1

    5.3 Anlaufstrom m. Sanftanlasser A 33 43 25

    5.4 Nennstrom A15 / W32 / cos M A / --- 17,0 / 0,8 21,0 / 0,8 10,0 / 0,8

    6 Entspricht den europischen Sicherheitsbestimmungen 3

    3. s. CE-Konformittserklrung

    3 3

    7 Sonstige Ausfhrungsmerkmale

    7.1 Abtauung automatisch automatisch automatisch

    Abtauart elektrisch elektrisch elektrisch

    Abtauwanne vorhanden ja (beheizt) ja (beheizt) ja (beheizt)

    7.2 Heizwasser im Gert gegen Einfrieren geschtzt 4

    4. Der Dauerlauf der Filterpumpe muss bauseitig gewhrleistet, sowie der Regler der Wrmepumpe betriebsbereit sein.

    ja ja ja

    7.3 Leistungsstufen 1 1 1

  • 7/29/2019 LAS 10-15 MT 22TT

    12/44

  • 7/29/2019 LAS 10-15 MT 22TT

    13/44

    www.dimplex.de E-1

    English

    Table of contents

    1 Please Read Immediately .............................................................................................................E-2

    1.1 Important Information:.............................................................................................................................E-21.2 Intended Use ..........................................................................................................................................E-21.3 Legal Regulations and Directives ...........................................................................................................E-2

    1.4 Energy-Efficient Use of the Heat Pump ..................................................................................................E-22 Purpose of the Heat Pump ...........................................................................................................E-3

    2.1 Application ..............................................................................................................................................E-32.2 Operating Principle .................................................................................................................................E-32.3 Dimensioning the Swimming Pool Heat Pump .......................................................................................E-3

    3 Scope of Delivery ..........................................................................................................................E-4

    3.1 Basic Device ...........................................................................................................................................E-43.2 Switch Box..............................................................................................................................................E-4

    4 Transport........................................................................................................................................E-4

    5 Installation .....................................................................................................................................E-4

    5.1 General Information................................................................................................................................E-45.2 Condensed Water Pipe...........................................................................................................................E-5

    6 Installation .....................................................................................................................................E-5

    6.1 General Information................................................................................................................................E-56.2 Swimming Pool Connections..................................................................................................................E-56.3 Electrical Connection..............................................................................................................................E-5

    7 Start-Up ..........................................................................................................................................E-6

    7.1 General Information................................................................................................................................E-67.2 Start-Up ..................................................................................................................................................E-6

    8 Description of Functions..............................................................................................................E-68.1 Heat Pump Remote Control....................................................................................................................E-68.2 Controller Board......................................................................................................................................E-78.3 Heating Function.....................................................................................................................................E-7

    9 Maintenance / Cleaning ................................................................................................................E-7

    9.1 Maintenance ...........................................................................................................................................E-79.2 Cleaning the Pipe System in the Heat Exchanger..................................................................................E-79.3 Cleaning the Air System.........................................................................................................................E-79.4 Winter Shutdown / Lay-Up......................................................................................................................E-79.5 Maintenance ...........................................................................................................................................E-8

    10 Faults / Trouble-Shooting.............................................................................................................E-8

    11 Decommissioning / Disposal .......................................................................................................E-8

    12 Device Information ........................................................................................................................E-9

    Anhang / Appendix / Annexes ............................................................................................................ A-I

  • 7/29/2019 LAS 10-15 MT 22TT

    14/44

    E-2

    1

    1 Please Read

    Immediately

    1.1 Important Information:

    ATTENTION!When transporting the heat pump, ensure that it is not tilted more than45 (in any direction).

    ATTENTION!The heat pump and transport pallet are only joined by the packing film.

    ATTENTION!Do not restrict or block the area around the air intake or outlet.

    ATTENTION!Ensure that there is a clockwise rotating field (for multiphase devices):Operating the compressor in the wrong rotational direction could causedamage to the compressor. Incorrect phase sequence causes wrong

    rotational direction of the ventilator and, thus, a significantly reducedperformance.

    ATTENTION!Never operate the heat pump without water flow!

    ATTENTION!The flow monitor must be designed for the required volume flow andensure permanent interconnection.

    ATTENTION!Never use cleaning agents containing sand, soda, acid or chloride asthese can damage the surfaces.

    ATTENTION!Before opening the device, ensure that all circuits are isolated from thepower supply.

    ATTENTION!The warranty does not cover damage caused by inadequate lay-upmeasures during the winter.

    ATTENTION!Work on the refrigerating circuit may only be performed by competentpersonnel.

    1.2 Intended UseThis device is only intended for use as specified by the manufac-turer. Any other use beyond that intended by the manufacturer isprohibited. This includes the user's abiding by the manufacturer'sproduct brochures. Please refrain from tampering with or alteringthe device.

    1.3 Legal Regulations andDirectives

    The construction and design of the heat pump complies with allrelevant EU directives, DIN/VDE regulations (see CE declarationof conformity).

    When connecting the heat pump to the power supply, the rele-vant VDE, EN and IEC standards are to be fulfilled. Any furtherconnection requirements stipulated by local utility companiesmust also be observed.

    When connecting the heating system, all applicable regulationsmust also be adhered to.

    Persons, especially children, who are not capable of operatingthe device safely due to their physical, sensory or mental abilitiesor their inexperience or lack of knowledge, must not operate thisdevice without supervision or instruction by the person in charge.

    Children must be supervised to ensure that they do not play withthe device.

    1.4 Energy-Efficient Use of theHeat Pump

    To maintain heat pump efficiency, it is particularly important tokeep the temperature difference between the domestic hot water

    and heat source to a minimum.Suitable heating water temperature, a carefully chosen locationfor the open-air pool, and the use of heat insulating pool coversare just some of the measures used to reduce heat energy re-quirements.

    It is important to ensure that the heat exchangers are not con-taminated during operation because this increases the tempera-ture difference, in turn reducing the COP.

  • 7/29/2019 LAS 10-15 MT 22TT

    15/44

    www.dimplex.de E-3

    English

    2.3

    2 Purpose of the Heat

    Pump

    2.1 ApplicationThe swimming pool heat pump is suitable for heating swimming

    pool water or saline water.The heat pump is equipped with an automatic evaporator de-frosting (de-icing) system. The heat pump may also be operatedin frosty external air temperatures, providing operating limits andconditions are observed.

    2.2 Operating PrincipleThe surrounding air is drawn in by the ventilator and fed via afinned heat exchanger, which extracts heat from the air. This en-ergy difference is then transferred to the working medium (refrig-erant) in the heat exchanger.

    An electrically driven compressor pumps this extracted heat to

    a higher temperature level by increasing its pressure. The heat isthen transferred to the water via a titanium heat exchanger.

    During heating operation, electrical operating energy is used toraise the temperature of the heat in the environment to a higherlevel. Because energy extracted from the air is transferred to thewater that is to be heated, this device is referred to as an air-to-water heat pump.

    The swimming pool heat pump consists of the main components:evaporator, ventilator and expansion valve, as well as the low-noise compressor, liquifier (titanium heat exchanger) and theelectrical control system.

    During heating operation at low ambient temperatures, humidityaccumulates on the evaporator in the form of frost, impairing heattransfer. The evaporator is automatically defrosted according toneed. Depending on atmospheric conditions, steam (water va-pour) may be briefly visible in the immediate vicinity of the airinlet or outlet when restarting.

    2.3 Dimensioning the SwimmingPool Heat Pump

    Outdoor swimming poolThe heat consumption for heating the water in an outdoor swim-ming pool depends strongly on the respective usage.

    In terms of size, it can easily be the same as the heat consump-tion of a house - and in such cases must be calculated sepa-rately.

    An approximate estimation of the heat consumption is dependenton the windage factor, the climatic conditions, the periods of useand whether or not the pool has a cover.

    Reference values for the heat consumption of outdoorswimming pools used between May and September

    For initially heating the pool to a temperature of over 20 C, thequantity of thermal energy required is approx. 12 kWh/m3 poolvolume. Heating-up periods ranging from one to three days arerequired depending on the size of the pool and the output of theinstalled heating system.

    Indoor swimming pool Space heating

    Space heating is carried out using radiators or underfloorheating and/or a heat exchanger in the dehumidification/ventilation system. In both cases it is necessary to calculatethe heat consumption - according to the system installed.

    Hot water heating for a swimming poolThe heat consumption depends on the pool temperature,

    the temperature difference between the pool temperatureand the room temperature, and the pool usage.

    Reference values for the heat consumption of indoor swim-ming pools

    These outputs can be reduced by up to 50 % for private swim-ming pools with a cover that are used for a maximum of 2 hoursper day.

    Water temperature

    20 C 24 C 28 C

    With cover1

    1. Reduced values for pools with a cover only refer to private swimming poolsused on average up to 2 h per day.

    100 W/m2 150 W/m2 200 W/m2

    Without coverSheltered location 200 W/m

    2 400 W/m2 600 W/m2

    Without coverPartly sheltered loca-

    tion

    300 W/m2 500 W/m2 700 W/m2

    Without coverUnsheltered location(subject to high winds)

    450 W/m2 800 W/m2 1,000 W/m2

    Room tempera-ture

    Water temperature

    20 C 24 C 28 C

    23 C 90 W/m2 165 W/m2 265 W/m2

    25 C 65 W/m2 140 W/m2 240 W/m2

    28 C 20 W/m2 100 W/m2 195 W/m2

  • 7/29/2019 LAS 10-15 MT 22TT

    16/44

    E-4

    3

    3 Scope of Delivery

    3.1 Basic DeviceThe heat pump is of compact design and is supplied completewith the components listed below.

    The refrigerant circuit contains the Kyoto protocol approved re-frigerant R407C with a GWP value of 1525. It is CFC-free, doesnot deplete ozone and is non-flammable.

    1) Evaporator

    2) Switch box

    3) Ventilator

    4) Fi lter dryer

    5) Compressor

    6) Titanium heat exchanger

    (Illustration: Front casing removed)

    3.2 Switch BoxThe switch box is located in the heat pump and can be accessedby removing the covering panel assembly (the panel assemblyscrew-holes are sealed by cover caps).

    The switch box contains the supply connection terminals, as wellas the power contactors, the soft starter unit and the remote con-trol connection terminals.

    Heat pump control is via the remote control provided in the scopeof supply (see also Section 8).

    4 Transport

    ATTENTION!When transporting the heat pump, ensure that it is not tilted more than45 (in any direction).

    Use the wooden pallet for transporting the heat pump to its final

    installation location. Either a lifting truck or 3/4" pipes fed throughthe holes in the base plate or frame can be used for transportingthe heat pump.

    ATTENTION!The heat pump and transport pallet are only joined by the packing film.

    To avoid injuring your hands, ensure that the pipes cannot slipwhen being used to lift the pump.

    When inserting the pipes through the frame, ensure that the com-ponents are not damaged (especially the plastic condensate trayand/or the drain stubs).

    5 Installation

    5.1 General InformationThe device should always be installed on a permanently smooth,even and horizontal surface. To counteract development of anysolid-borne sound, the entire frame (and its supporting surface)should be in contact with the floor. If this is not possible, addi-tional constructional measures to improve sound insulation mayneed to be provided by the customer. It must be possible to carryout maintenance work without hindrance. This can be ensured bymaintaining a clearance of 1.2 m around the device.

    ATTENTION!Do not restrict or block the area around the air intake or outlet.

    &OHDUHGDLURXWOHWGLUHFWLRQ

  • 7/29/2019 LAS 10-15 MT 22TT

    17/44

    www.dimplex.de E-5

    English

    6.3

    5.2 Condensed Water PipeCondensed water that forms during operation must be drainedoff frost-free. The heat pump must be mounted on a level planeto guarantee proper drainage. The condensed water pipe musthave a minimum diameter of 50 mm and must be fed frost-freeinto a sewer or a suitably dimensioned, deep gravel drainage pit.

    The condensate pipe should be centrically placed under thedrain stubs of the condensate tray (see also the dimension draw-ing in the Appendix). Alternative means of condensate drainageare to be agreed upon with the manufacturer.

    Condensate should not be drained directly into clearing tanksand cesspits because any rising, aggressive vapours could de-stroy the evaporator.

    6 Installation

    6.1 General InformationThe following connections need to be established on the swim-ming pool heat pump:

    Flow and return flow of the swimming pool system

    Condensate outflow

    Control line to remote control

    Power supply

    Control line to on-site release contact (floating)

    6.2 Swimming Pool ConnectionsThe water pipe connections on the heat pump have 1" and/or1 1/2" external threads. A pipe wrench must be used to firmly grip

    the transitions when connecting the heat pump.The water pipes are connected via a bypass on the filter circuit ofthe swimming pool located downstream of the filter and upstreamof the water preparation system. When plastic pipes are con-nected, suitable temperature measuring points should be pro-vided directly on the flow and return flow connections of theswimming pool heat pump (e.g. immersion sleeves).

    Before the water pipes are connected to the heat pump, theswimming pool water system must be flushed to remove any im-purities, sealant residue, etc. We strongly recommend installinga filter system in the water circuit. Any accumulation of deposits(leaves, grass or other organic contaminants) in the liquifier maycause total breakdown of the heat pump. Suitable hydraulic in-

    stallation, adjustment and dimensioning of the filter/circulatingpump ensures the minimum water flow rate through the heatpump for trouble-free operation.

    Once the water pipes have been installed, the system must befilled, de-aerated and pressure-tested.

    Minimum water flow rateThe swimming pool heat pump does not have an integrated cir-culation pump. The required water flow rate must be provided byan external filter pump and signalled back to the heat pump viathe respective input.

    ATTENTION!

    Never operate the heat pump without water flow!

    Antifreeze (frost protection)Manual drainage (see Hydraulic Plumbing Diagram in the Ap-pendix) has to be provided for heat pumps exposed to frost. Toensure frost protection, continuous operation of the fil ter pump atair temperatures below 5C must be ensured on site (e.g. byusing a frost protection thermostat) (see the information inChapter 9.4 Winter Shutdown / Lay-Up).

    6.3 Electrical ConnectionDepending on device type, the heat pump is connected to thepower supply via a standard 3-core cable (1-phase devices) orstandard 5-core cable (3-phase devices).

    The cable(s) is(are) to be provided by the customer. The con-ductor cross section is selected in accordance with the powerconsumption of the heat pump (see Appendix Device Informa-tion) and the applicable VDE (EN) and VNB regulations.

    Both an all-pole disconnecting device with a contact gap of atleast 3 mm (e.g. utility blocking contactor or power contactor), aswell as a 3-pole and/or 1-pole circuit breaker with common trip-

    ping for all external conductors (tripping current in compliancewith the Device Information) must be installed.

    Ensure that the incoming supply has a clockwise rotating fieldwhen connecting multiphase devices.

    Phase sequence: L1, L2, L3.

    ATTENTION!Ensure that there is a clockwise rotating field (for multiphase devices):Operating the compressor in the wrong rotational direction could causedamage to the compressor. Incorrect phase sequence causes wrongrotational direction of the ventilator and, thus, a significantly reducedperformance.

    The device supplies the control voltage to the remote control.

    The connecting cable (control line) from the remote control to theheat pump (not included in the scope of supply) must be suitablefor a 230 V supply voltage. The cable must be 5-core (at least)and have a single-core cross section of at least 0.5 mm.

    The connection line from the heat pump to an on-site releasecontact must be suitable for a network voltage of 230 V.

    The heat pump does not have an integrated circulating pump.The required water flow must be provided by an external filterpump and signalled back to the heat pump via the respective in-put. Terminals 2 and 3 of terminal strip X2 should be used for thispurpose. Release is made via a floating on-site contact (K29).

    ATTENTION!The flow monitor must be designed for the required volume flow andensure permanent interconnection.

    The heat pump power supply is in accordance with the technicaldata of the device: 1/N/PE ~ 230 V, 50 Hz or 3/N/PE ~ 400 V,50 Hz.

    The heat pump is connected via the terminal strips in the switchbox. For detailed information see Circuit Diagrams in the Appen-dix.

  • 7/29/2019 LAS 10-15 MT 22TT

    18/44

    E-6

    7

    7 Start-Up

    7.1 General InformationTo ensure that start-up is performed correctly, it should only becarried out by an after-sales service technician authorized by themanufacturer. Only then can an extended warranty period of

    3 years in total be granted (see Warranty Service).

    7.2 Start-UpThe following items need to be checked prior to start-up:

    The heat pump must be fully connected, as described inChapter 6.

    Any valves that might impair proper water flow in the watercircuit must be opened.

    The air intake and air outlet paths must be clear.

    The ventilator must turn in the direction indicated by the ar-row.

    The remote control must be operational. Ensure the condensate outflow functions.

    After connecting the operating voltage and switching on theswimming pool heat pump, there will be a pre-programmed5-minute compressor pause time before the heat pumpstarts up.

    The bypass and regulator valves must be set so that theminimum water flow is in accordance with the Device Infor-mation. The following maximum temperature spreads be-tween water inlet and water outlet are set for the operatingpoint.

    8 Description of Functions

    8.1 Heat Pump Remote ControlThe heat pump can be switched on and off inside the building(Frost-free and dry) via the remote control. The heat pump is op-erational at water temperatures

  • 7/29/2019 LAS 10-15 MT 22TT

    19/44

    www.dimplex.de E-7

    English

    9.4

    8.2 Controller Board

    8.3 Heating FunctionStart the heat pump by moving the switch (1) to the On position(I). The desired return temperature is set via the rotary knob (4).This is requested via the potentiometer and lies within a range of10 C min. and 40 C max. Once the set temperature is reached,the heat pump switches off. It switches on again when the returntemperature sinks to 1 Kelvin below the set value. It is not possi-

    ble to re-start the heat pump until after a minimum pause time of20 minutes (after defrosting of the evaporator). The heat pumpswitches off at a maximum flow temperature of 45 C, or whenthe air temperature is too low (lower operating limit -10 C).

    9 Maintenance / Cleaning

    9.1 MaintenanceTo protect the paintwork, avoid leaning or putting objects on thedevice. External heat pump parts can be wiped with a damp clothand domestic cleaner.

    ATTENTION!Never use cleaning agents containing sand, soda, acid or chloride asthese can damage the surfaces.

    To prevent faults due to sediments in the titanium heatexchanger of the heat pump, ensure that the heat exchangercannot be contaminated (water treatment and filter system nec-essary). In the event that operating malfunctions due to contam-ination still occur, the system should be cleaned as described be-low. (Warning: the fins on the finned tube heat exchanger aresharp-edged -> danger of being cut!)

    9.2 Cleaning the Pipe System inthe Heat ExchangerContamination in the pipes and heat exchanger can reduce theperformance of the heat pumps titanium heat exchanger. If thisis the case, the pipe system and heat exchanger must becleaned by a technician.

    Use only pressurised drinking water for cleaning.

    9.3 Cleaning the Air SystemThe finned heat exchanger, ventilator and condensate outflowshould be cleaned of contaminants (leaves, twigs, etc.) before

    each new heating period. These types of contaminants can bemanually removed using compressed air or by flushing withclean water.

    It may be necessary to remove the device cover and air inlet gridfirst.

    ATTENTION!Before opening the device, ensure that all circuits are isolated from thepower supply.

    To prevent the evaporator and the condensate tray from beingdamaged, do not use hard or sharp objects for cleaning.

    Under extreme weather conditions (e.g. snow drifts), ice may

    form on the air intake and exhaust air outlet grids. If this happens,the ice must be removed in the vicinity of the air intake and ex-haust air outlet grids to ensure that the minimum air flow rate ismaintained.

    9.4 Winter Shutdown / Lay-UpIf there is a chance of frost after the bathing-season has endedwhen the swimming pool heating is switched off and the externaltemperature is expected to drop below the operating limit, thewater circuit of the heat pump should be completely drained. Oth-erwise, suitable constructional measures should be taken by thecustomer to protect the heat pump against damage from frost.

    ATTENTION!The warranty does not cover damage caused by inadequate lay-upmeasures during the winter.

    / IODVKHVGXULQJRSHUDWLRQ

    / QRWXVHG

    / IODVKHVLIDIDXOWRFFXUVUHG

    ', QRWXVHG

    ', QRWXVHG

    ', QRWXVHG

    ', RQILOWHUSXPSRQDQGKLJKSUHVVXUHVZLWFKLQZRUNLQJRUGHU

    '2 RQFRPSUHVVRUDQGYHQWLODWRUDUHUXQQLQJ

    '2 QRWXVHG

    '2 'HIURVWKHDWHURIIKHDWLQJRQ'HIURVW

    '2 QRWXVHG

    '2 QRWXVHG

    '2 RQ)URVWSURWHFWLRQUHTXHVW

    '2 QRWXVHG

    '2 QRWXVHG

    ',QRWXVHG', QRWXVHG

    ', RQORZSUHVVXUHVZLWFKLQZRUNLQJRUGHU

    ', QRWXVHG

    ', QRWXVHG

    ', QRWXVHG

    /

    /

    /

    ',

    ',

    ',

    ',

    '2 '2 '2 '2 '2

    '2

    '2

    '2

    ',

    ',

    ',

    ',

    ',

    ',

  • 7/29/2019 LAS 10-15 MT 22TT

    20/44

    E-8

    9.5

    9.5 MaintenanceDevices with a minimum of 3 kg refrigerant, or hermeticallysealed devices with a minimum of 6 kg refrigerant must be leak-proof tested yearly by the operator according to ES842/2006.

    10 Faults / Trouble-

    ShootingThis heat pump is a quality product and is designed for trouble-free and maintenance-free operation. However, if a fault does oc-cur, use the following information to check whether you can elim-inate the fault yourself.

    The heat pump will not run!

    Please check whether:

    There is supply voltage (tripped fuse, power failure).

    The operating switch on the remote control is switched on,and whether the correct setpoint temperature has been set.

    The set temperature level cannot be reached!Please check whether:

    The permissible operating conditions for the heat pumphave been adhered to (air temperatures too high or too low).

    The air inlet or outlet area is blocked, restricted or very dirty.

    There are closed valves or stop-cocks in the water pipes.

    If you cannot correct the fault yourself, please contact your after-sales service technician (see Warranty Certificate).

    Work on the heat pump may only be carried out by authorisedand qualified after-sales service technicians.

    11 Decommissioning /

    DisposalBefore removing the heat pump, disconnect it from the powersource and close all valves. Observe all environmentally-relevantrequirements regarding the recovery, recycling and disposal of

    materials and components in accordance with all applicablestandards. Particular attention should be paid to the proper dis-posal of refrigerants and refrigeration oils.

  • 7/29/2019 LAS 10-15 MT 22TT

    21/44

    www.dimplex.de E-9

    English

    12

    12 Device Information

    1 Type and order code LAS 10MT LAS 15MT LAS 22TT

    2 Design

    2.1 Degree of protection according to EN 60 529 for compact devices andheating components

    IP 24 IP 24 IP 24

    2.2 Installation location Outdoors Outdoors Outdoors

    3 Performance data

    3.1 Operating temperature limits:

    Heating water flow / return flow 1 C / C

    1. See operating limits diagram

    Up to 40 / above 10 Up to 40 / above 10 Up to 40 / above 10

    Air C -10 to +35 -10 to +35 -10 to +35

    3.2 Heat output / COP at A20 / W24 2 kW / -

    2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrostingcapacity, the bivalence point and regulation, should also be taken into consideration. E.g. A20 / W24 have the following meaning: external air temperature 20C and swimmingpool flow temperature 24 C.

    12.1 / 4.2 16.6 / 4.7 22.3 / 5.1

    3.3 Sound power level dB(A) 70 70 71

    3.4 Sound pressure levelat a distance of 10 m (air outlet side) dB(A)

    45 45 46

    3.5 Pool water flow with an internal pressure differential of m/h / Pa 1.6 / 7200 2.0 / 12000 2.5 / 8000

    3.6 Refrigerant; total filling weight type / kg R407C / 1.5 R407C / 1.6 R407C / 2.5

    3.7 Lubricant; total filling weight type / litres FV68S / 1.7 FV68S / 1.7 FV68S / 1.7

    3.8 El. output of defrost heater kW 1.8 2.4 3.04 Dimensions, connections and weight

    4.1 Device dimensions H x W x L cm 86 x 127 x 67 86 x 127 x 67 86 x 127 x 67

    4.2 Device connections to heating system Inch G 1'' external G 1'' external G 1 1/2'' external

    4.3 Weight of the transportable unit(s) incl. packing kg 147 155 162

    5 Electrical Connection

    5.1 Nominal voltage; fuse protection V / A 230 / 20 230 / 25 400 / 16

    5.2 Nominal power consumption 2 A15 / W32 kW 3.3 4.0 5.1

    5.3 Starting current with soft starter A 33 43 25

    5.4 Nominal current A15 / W32 / cos M A / --- 17.0 / 0.8 21.0 / 0.8 10.0 / 0.8

    6 Complies with the European safety regulations 3

    3. See CE declaration of conformity

    3 3

    7 Additional model features

    7.1 Defrosting Automatic Automatic Automatic

    Type of defrosting Electrical Electrical Electrical

    Defrosting tray included Yes (heated) Yes (heated) Yes (heated)

    7.2 Heating water in device protected against icing 4

    4. Continuous operation of the filter pump must be ensured on-site and the heat pump controller must be ready for operation.

    Yes Yes Yes

    7.3 Performance levels 1 1 1

  • 7/29/2019 LAS 10-15 MT 22TT

    22/44

    E-10

    12

  • 7/29/2019 LAS 10-15 MT 22TT

    23/44

    www.dimplex.de F-1

    Franais

    Table des matires

    1 Lire immdiatement S.V.P. ...........................................................................................................F-2

    1.1 Informations importantes ........................................................................................................................F-2

    1.2 Utilisation conforme ................................................................................................................................ F-2

    1.3 Dispositions lgales et directives............................................................................................................ F-2

    1.4 Utilisation de la pompe chaleur pour conomiser de l'nergie ............................................................ F-2

    2 Utilisation de la pompe chaleur ................................................................................................F-3

    2.1 Domaine dutilisation............................................................................................................................... F-3

    2.2 Fonctionnement ...................................................................................................................................... F-3

    2.3 Etude et conception dune pompe chaleur de piscine .........................................................................F-3

    3 Fournitures ....................................................................................................................................F-4

    3.1 Appareil de base.....................................................................................................................................F-4

    3.2 Botier lectrique..................................................................................................................................... F-4

    4 Transport........................................................................................................................................F-4

    5 Emplacement de montage............................................................................................................F-4

    5.1 Remarques dordre gnral ....................................................................................................................F-4

    5.2 Ecoulement de leau de condensation....................................................................................................F-5

    6 Installation .....................................................................................................................................F-5

    6.1 Remarques dordre gnral ....................................................................................................................F-5

    6.2 Raccordement la piscine .....................................................................................................................F-5

    6.3 Branchements lectriques......................................................................................................................F-5

    7 Mise en service..............................................................................................................................F-6

    7.1 Remarques dordre gnral ....................................................................................................................F-6

    7.2 Mise en service....................................................................................................................................... F-6

    8 Fonctionnement ............................................................................................................................F-6

    8.1 Rgleur distance de la pompe chaleur .............................................................................................F-6

    8.2 Panneau de commande.......................................................................................................................... F-7

    8.3 Fonction chauffage ................................................................................................................................. F-7

    9 Nettoyage / entretien.....................................................................................................................F-7

    9.1 Entretien ................................................................................................................................................. F-7

    9.2 Nettoyage du systme de conduites de lchangeur thermique............................................................. F-7

    9.3 Nettoyage ct air................................................................................................................................... F-7

    9.4 Mise hors service dhiver / hivernage .....................................................................................................F-89.5 Entretien ................................................................................................................................................. F-8

    10 Dfaillances / recherche des pannes ..........................................................................................F-8

    11 Mise hors service / mise au rebut................................................................................................F-8

    12 Informations sur les appareils .....................................................................................................F-9

    Anhang / Appendix / Annexes ............................................................................................................ A-I

  • 7/29/2019 LAS 10-15 MT 22TT

    24/44

    F-2

    1

    1 Lire immdiatement

    S.V.P.

    1.1 Informations importantes

    ATTENTION !Lors du transport, langle dinclinaison de la pompe chaleur ne doit pasdpasser 45 (quel que soit le sens).

    ATTENTION !Pompe chaleur et palette de transport ne sont en contact que par lafeuille demballage.

    ATTENTION !Les canaux daspiration et dvacuation d'air ne doivent tre ni rtrcis,ni obturs.

    ATTENTION !Garantir la rotation droite du champ magntique de l'alimentation

    (appareils polyphass) : Le compresseur peut tre endommag si le sensde rotation est le mauvais. Un ordre incorrect des phases engendre unmauvais sens de rotation du ventilateur et par consquent une fortediminution des performances.

    ATTENTION !Ne jamais faire fonctionner la pompe chaleur sans dbit d'eau !

    ATTENTION !Le contrleur de dbit doit tre dimensionn en fonction du fluxvolumique ncessaire et permettre une commutation tout moment.

    ATTENTION !

    Ne jamais utiliser de produits dentretien contenant du sable, de la soude,de lacide ou du chlore, car ils attaquent les surfaces.

    ATTENTION !Avant douvrir lappareil, vrifier que tous les circuits lectriques sontbien hors tension.

    ATTENTION !Les dommages engendrs par de mauvaises mesures dhivernage nesont pas couverts par la garantie.

    ATTENTION !Les travaux sur le circuit rfrigrant ne doivent tre effectus que par despersonnes qualifies.

    1.2 Utilisation conformeCet appareil est destin uniquement l'utilisation prvue par lefabricant. Toute autre utilisation est considre comme non con-forme. La documentation accompagnant les produits doit gale-ment tre prise en compte. Toute modification ou transformationde l'appareil est interdite.

    1.3 Dispositions lgales etdirectives

    Lors de la construction et de la ralisation de la pompe chaleur,toutes les normes CE et prescriptions DIN et VDE concernesont t respectes (voir dclaration de conformit CE).

    Les normes VDE, EN et CEI correspondantes sont respecterlors du branchement lectrique de la pompe chaleur. D'autrepart, les prescriptions de branchement des exploitants de r-seaux d'alimentation doivent tre respectes.

    Les prescriptions affrentes sont respecter lors du branche-ment sur le circuit d'eau.

    Les personnes, en particulier les enfants, qui, compte tenu deleurs capacits physiques, sensorielles ou intellectuelles, ou deleur manque d'exprience ou de connaissances, ne sont pas enmesure d'utiliser l'appareil en toute sret, ne devraient pas lefaire en l'absence ou sans instructions d'une personne responsa-ble.

    Les enfants doivent tre surveills pour viter qu'ils ne jouentavec l'appareil.

    1.4 Utilisation de la pompe chaleur pour conomiser de

    l'nergiePour utiliser une pompe chaleur de manire efficace, il est par-ticulirement important de maintenir un cart de tempratureaussi rduit que possible entre leau chaude et la source de cha-leur.

    Une temprature d'eau de chauffage adapte, un choix appro-pri de l'emplacement du bassin et lutilisation dun revtementcalorifuge pour la piscine sont quelques exemples de mesurespermettant une rduction supplmentaire du besoin d'nergie.

    Pendant le fonctionnement, veiller ce quaucune impuret nepntre dans lchangeur thermique car ceci lverait l'cart detemprature, faisant ainsi diminuer le coefficient de performance.

  • 7/29/2019 LAS 10-15 MT 22TT

    25/44

    www.dimplex.de F-3

    Franais

    2.3

    2 Utilisation de la pompe

    chaleur

    2.1 Domaine dutilisationLa pompe chaleur de piscine est destine rchauffer leau de

    piscine ou leau charge de sel.La pompe chaleur est quipe dun dispositif de dgivrageautomatique de lvaporateur. A condition den respecter les limi-tes et conditions dutilisation, la pompe chaleur peut aussi treutilise par des tempratures extrieures en-dessous de zro.

    2.2 FonctionnementLair environnant est aspir par le ventilateur et dirig vers unchangeur thermique lamelles qui soustrait lair sa chaleur.La diffrence en nergie est transmise au fluide utilis (fluide fri-gorigne) dans lchangeur thermique.

    Au moyen dun compresseur commande lectrique, la chaleur

    absorbe est pompe par augmentation de pression un ni-veau de temprature plus lev puis rendue l'eau via lchan-geur thermique titane.

    En mode chauffage, c'est lnergie lectrique motrice qui faitpasser la chaleur de l'environnement un niveau de tempratureplus lev. Comme lnergie soustraite lair est transmise leau rchauffer, on appelle cet appareil galement pompe chaleur air/eau .

    La pompe chaleur pour piscine comprend un vaporateur, unventilateur et une vanne dexpansion (composants principaux),ainsi quun compresseur peu bruyant, un condenseur (chan-geur thermique titane) et une commande lectrique.

    En mode chauffage et basses tempratures de lenvironne-ment, lhumidit de lair saccumule sous forme de givre sur lva-porateur, limitant ainsi la transmission de chaleur. Lvaporateurest dgivr automatiquement selon les besoins. En fonction desconditions mtorologiques, des nuages de vapeur peuvent ap-paratre temporairement lors du redmarrage lentre ou lasortie dair.

    2.3 Etude et conception dunepompe chaleur de piscine

    Piscine dcouverteLe besoin en chaleur ncessaire au rchauffement de leau

    dune piscine extrieure dpend fortement des habitudes dutili-sation.

    Ce besoin peut correspondre, selon lordre de grandeur, celuidune maison individuelle et doit, dans de tels cas, tre calculsparment.

    La dtermination approximative du besoin en chaleur dpend delexposition au vent du bassin, de la temprature du bassin, desconditions climatiques, de la priode dutilisation et de la pr-sence ou non dun systme de couverture de la surface du bas-sin.

    Valeurs de rfrence pour le besoin en chaleur de piscinesextrieures utilises de mai septembre.

    Pour la premire chauffe du bassin une temprature de plus de20 C, il est ncessaire davoir une quantit de chaleur denv.12 kWh/m3 de contenance du bassin. Des temps de chauffagede 1 3 jours sont ncessaires selon la taille du bassin et la puis-sance calorifique installe.

    Piscine couverte Chauffage du btiment

    Le chauffage du btiment seffectue gnralement par ra-diateurs ou chauffage au sol et/ou par registres de chauf-fage dans linstallation de dshumidification / daration.Dans les deux cas, un calcul du besoin en chaleur est n-cessaire, en fonction de la solution technique utilise.

    Chauffage de leau de piscineLe besoin en chaleur dpend de la temprature de leau dubassin, de la diffrence entre la temprature de leau dubassin et celle du btiment, ainsi que de lutilisation faite dela piscine.

    Valeurs de rfrence pour le besoin en chaleur de piscinescouvertes

    Dans le cas de piscines prives munies dun systme de couver-ture du bassin et dont lutilisation ne va pas au-del de 2 heurespar jour, ces puissances peuvent tre rduites jusqu 50%.

    Temprature de leau

    20 C 24 C 28 C

    avec couverture1

    1. Les valeurs rduites pour bassins couverts ne sont valables que pour les pis-cines prives utilises jusqu 2 h par jour.

    100 W/m2 150 W/m2 200 W/m2

    sans couverture ;emplacement protg 200 W/m

    2 400 W/m2 600 W/m2

    sans couverture ;emplacement protg

    en partie

    300 W/m2 500 W/m2 700 W/m2

    sans couverture ;emplacement non pro-tg (vent fort)

    450 W/m2 800 W/m2 1000 W/m2

    Tempratureambiante

    Temprature de leau20 C 24 C 28 C

    23 C 90 W/m2 165 W/m2 265 W/m2

    25 C 65 W/m2 140 W/m2 240 W/m2

    28 C 20 W/m2 100 W/m2 195 W/m2

  • 7/29/2019 LAS 10-15 MT 22TT

    26/44

    F-4

    3

    3 Fournitures

    3.1 Appareil de baseLa pompe chaleur est livre sous forme compacte et contientles composants numrs ci-dessous.

    Le circuit rfrigrant contient le fluide frigorigne fluor R407Cavec une valeur de PRG de 1525, rpertori dans le protocole deKyoto. Il est sans HCFC, inoffensif pour la couche dozone etininflammable.

    1) Evaporateur

    2) Botier lectrique

    3) Ventilateur

    4) Sche-fi ltre

    5) Compresseur

    6) Echangeur thermique titane

    (Figure : face avant du botier dmont)

    3.2 Botier lectriqueLe botier lectrique est mont dans la pompe chaleur et estaccessible une fois retir le panneau dhabillage se trouvant de-vant lui (les orifices de fixation par vis des panneaux dhabillagesont obturs par des caches).

    Dans le botier lectrique se trouvent les bornes de branchementsecteur, les contacteurs de puissance, lunit de dmarrage pro-gressif et les bornes de connexion du rgleur distance.

    La commande de la pompe chaleur seffectue via un rgleur distance fourni la livraison (cf. galement point 8.).

    4 Transport

    ATTENTION !Lors du transport, langle dinclinaison de la pompe chaleur ne doit pasdpasser 45 (quel que soit le sens).

    Le transport vers lemplacement dfinitif doit de prfrence s'ef-

    fectuer sur une palette en bois. La pompe chaleur peut tretransporte avec un chariot lvateur ou au moyen de tubes 3/4"passs au travers des orifices de lembase ou du chssis.

    ATTENTION !Pompe chaleur et palette de transport ne sont en contact que par lafeuille demballage.

    En cas dutilisation de tubes porteurs, veiller ce que ceux-ci nepuissent se dloger afin dviter dventuelles blessures (auxmains par ex.) lors du transport !

    Lors du passage des tubes porteurs travers le chssis, veiller ne pas endommager les composants (en particulier le bacplastique d'eau de condensation ou le tube de vidange).

    5 Emplacement de

    montage

    5.1 Remarques dordre gnralD'une manire gnrale, lappareil doit tre install sur une sur-face durablement plane, lisse et horizontale. Le chssis (plusexactement ses surfaces dappui) doivent adhrer au sol surtoute leur surface pour parer la formation ventuelle de bruits

    de structure. Si cela nest pas possible, des travaux supplmen-taires dinsonorisation peuvent s'avrer ncessaires. Les travauxde maintenance doivent pouvoir tre effectus sans problme.Ceci n'est possible que si un dgagement de 1,2 m autour delappareil est respect.

    ATTENTION !Les canaux daspiration et dvacuation d'air ne doivent tre ni rtrcis,ni obturs.

    6HQVGpYDFXDWLRQOLEUH

  • 7/29/2019 LAS 10-15 MT 22TT

    27/44

    www.dimplex.de F-5

    Franais

    6.3

    5.2 Ecoulement de leau decondensation

    Leau de condensation produite en cours de fonctionnement doittre vacue sans risque de gel. Pour garantir un coulement ir-rprochable, la pompe chaleur doit se trouver lhorizontale.Le tuyau deau de condensation doit avoir un diamtre dau

    moins 50 mm, tre protg du gel et dboucher dans la canalisa-tion deaux uses ou dans un puisard en gravier suffisammentgrand et profond.

    Le tuyau dvacuation deau de condensation doit tre centrsous le tube de vidange du bac (cf. galement schma cot enannexe). Tout autre type dvacuation de leau de condensationdoit faire l'objet d'un accord du fabricant.

    Ne pas diriger directement leau de condensation vers les bas-sins de dcantation ou les fosses car les vapeurs corrosives as-cendantes pourraient dtruire lvaporateur.

    6 Installation

    6.1 Remarques dordre gnralLa pompe chaleur de piscine doit tre quipe des raccorde-ments suivants :

    Circuits dpart et retour pour la piscine

    Ecoulement de leau de condensation

    Cble de commande vers rgleur distance

    Alimentation lectrique

    Ligne de commande menant au contact de validation (librede potentiel) de fourniture client

    6.2 Raccordement la piscineLes raccordements lalimentation en eau de la pompe cha-leur ont des filetages extrieurs de 1" ou 1 1/2". Lors du raccor-dement la pompe chaleur, bloquer les raccords avec une clserre-tubes.

    Le raccordement au circuit deau se fait par une drivation du cir-cuit de filtrage du bassin, en aval du filtre et en amont du traite-ment deau. Lors du raccordement de tuyaux en plastique, pr-voir directement sur les raccords aller et retour de la PAC depiscine des points de mesure de la temprature adapts (doigtsde gant par ex.).

    Avant de raccorder la pompe chaleur au circuit d'eau, rincer lesystme deau de piscine pour liminer les impurets et les res-tes de matriaux dtanchit ventuels, ou autres salets. Il estvivement conseill de monter une installation de filtrage dans lecircuit deau. Une accumulation de dpts (feuilles, herbe etautres dtritus organiques ou inorganiques) dans le condenseurpeut entraner une dfaillance totale de la pompe chaleur. Unraccordement et un rglage hydrauliques appropris et un di-mensionnement correct de la pompe de filtrage et de circulationgarantissent le dbit deau minimal de la pompe chaleur nces-saire un fonctionnement sans heurts.

    Une fois termin le raccordement l'alimentation en eau, linstal-lation doit tre remplie, purge et teste sous pression.

    Dbit deau minimalLa pompe chaleur de piscine ne possde pas de pompe de cir-culation propre. Une pompe de fitration externe garantit le dbitdeau ncessaire et envoie cette information la pompe cha-leur via lentre correspondante.

    ATTENTION !

    Ne jamais faire fonctionner la pompe chaleur sans dbit d'eau !

    Protection antigelDans le cas de pompes chaleur exposes au gel, il faut prvoirune vidange manuelle (cf. annexe Schma hydraulique ).Lorsque la temprature de l'air descend au-dessous de 5 C, leclient devra assurer le fonctionnement continu de la pompe de fil-tration (au moyen d'un thermostat de protection antigel par ex.)pour garantir le bon fonctionnement de la fonction antigel (cf. re-marque Chap. 9.4 Mise hors service dhiver / hivernage ).

    6.3 Branchements lectriquesLe raccordement en puissance de la pompe chaleur seffectue,

    en fonction du type dappareil, par un cble 3 fils (appareils mo-nophass) ou 5 fils (appareils triphass) disponible dans le com-merce.

    Le(s) cble(s) doi(ven)t tre mis disposition par le client et lasection de chaque conducteur doit tre choisie en fonction de laconsommation de puissance de la pompe chaleur (cf. annexeinformations sur les appareils) et selon les prescriptions VDE,EN et CEI affrentes.

    Prvoir pour lalimentation de puissance un dbranchement detous les ples avec au moins 3 mm dcartement douverture decontact (par ex. sur le disjoncteur gnral ou sur le contacteur depuissance), ainsi quun coupe-circuit automatique tripolaire ouunipolaire (appareil 1), avec dclenchement simultan de tous

    les conducteurs extrieurs (intensit de dclenchement con-forme aux informations sur les appareils).

    Lors du raccordement dappareils polyphass, garantir la rota-tion droite du champ magntique de lalimentation de charge.

    Ordre des phases : L1, L2, L3. L1, L2, L3.

    ATTENTION !Garantir la rotation droite du champ magntique de l'alimentation(appareils polyphass) : Le compresseur peut tre endommag si le sensde rotation est le mauvais. Un ordre incorrect des phases engendre unmauvais sens de rotation du ventilateur et par consquent une fortediminution des performances.

    L'alimentation en tension de l'appareil procure au rgleur dis-tance la tension ncessaire.

    Le cordon de raccordement (ligne de commande) du rgleur distance de la pompe chaleur (non fourni) doit tre adapt une tension secteur de 230 V. Le cordon doit avoir 5 fils (au mi-nimum) et la section de chaque conducteur doit tre de 0,5 mmmin.

    Le cble de raccordement entre la pompe chaleur et le contactde validation de fourniture client doit tre dimensionn pour unetension secteur de 230 V.

    La pompe chaleur n'est pas quipe d'un circulateur propre.Une pompe de filtration externe doit garantir le dbit d'eau n-cessaire qui est communiqu la pompe chaleur via l'entre

    correspondante. Utiliser dans ce but les bornes 2 et 3 du bornierX2. Un contact libre de potentiel (K29) de fourniture client permetla validation.

  • 7/29/2019 LAS 10-15 MT 22TT

    28/44

    F-6

    7

    ATTENTION !Le contrleur de dbit doit tre dimensionn en fonction du fluxvolumique ncessaire et permettre une commutation tout moment.

    Lalimentation en courant de la pompe chaleur rpond aux don-nes techniques de lappareil, soit 1/N/PE ~ 230 V, 50 Hz ou3/N/PE ~ 400 V, 50 Hz.

    Le raccordement la pompe chaleur seffectue via les borniersdu botier lectrique. Pour des informations plus dtailles, cf.schmas lectriques en annexe.

    7 Mise en service

    7.1 Remarques dordre gnralPour garantir une mise en service en rgle, cette dernire doittre effectue par un service aprs-vente agr par le construc-teur. C'est uniquement ces conditions qu'une garantie de d-sormais 3 ans au total sera accorde (cf. Garantie).

    7.2 Mise en serviceAvant la mise en service, il est impratif de procder aux vrifica-tions suivantes :

    tous les raccordements de la pompe chaleur doivent treraliss comme dcrit au chapitre 6.

    les lments de robinetterie ventuellement monts sur lecircuit deauet susceptibles d'en perturber la circulation doi-vent tre ouverts.

    les voies daspiration et d'vacuation de lair doivent tre d-gages.

    le sens de rotation du ventilateur doit correspondre la di-rection de la flche.

    le rgleur distance doit toujours tre prt fonctionner.

    lcoulement de leau de condensation doit tre assur.

    Aprs la mise sous tension oula mise en marche de lapompe chaleur de piscine, celle-ci ne dmarre rellementquaprs une priode darrt du compresseur de 5 minutesinhrente son fonctionnement et prprogramme.

    Les vannes de drivation et de rgulation doivent tre r-gles pour assurer le dbit deau minimal mentionn dansles informations sur les appareils. Les diffrences de temp-rature maximales enregistres au point de fonctionnemententre dpart et retour d'eau sont les suivantes :

    8 Fonctionnement

    8.1 Rgleur distance de la pompe chaleur

    Le rgleur distance plac lintrieur ( l'abri du gel et au sec)

    du btiment permet d'allumer et d'teindre la pompe chaleur.Eteindre signifie ici commuter en fonction stand-by , c--d.que la fonction de protection antigel de la pompe chaleur resteactive tant que la pompe est alimente en tension secteur. Lapompe chaleur fonctionne lorsque la temprature de l'eau< 10 C. En cas de risque de gel, le client devra assurer le fonc-tionnement continu de la pompe de filtration pour garantir le bonfonctionnement de la fonction antigel (au moyen d'un thermostatexterne de protection antigel par ex.).

    Le bouton rotatif du rgleur distance permet de fixer la temp-rature de leau de la piscine.

    La plage de temprature de l'eau permettant une utilisation de laPAC s'tend de +10 C +40 C.

    1) Commutateur marche/arrt

    2) Diode lectroluminescente (verte), sallume indpendam-ment de la position du commutateur (indique que la pompe chaleur est en tat de marche)

    3) sans fonction

    4) Rgulateur de la temprature consigne de leau

    Position max. (bute droite) temprature consigne de leau :40 C.

    Position min. (bute gauche) temprature consigne de leau :10 C.

    Deux bagues sur le bouton de rglage permettent de limiter m-caniquement la plage de rglage. (remarque : avant dajuster lesbagues, placer le bouton de rglage peu prs au milieu de laplage de rglage dsire).

    Temprature de l'airextrieure Diffrence de temprature max.

    entre arrive et sortie deaude

    18 C 20 C 6-7 K

    15 C 18 C 5-6 K

  • 7/29/2019 LAS 10-15 MT 22TT

    29/44

    www.dimplex.de F-7

    Franais

    9.3

    8.2 Panneau de commande

    8.3 Fonction chauffageLa pompe chaleur est mise en service lorsque le commutateur(1) est regl sur la position marche (I). La temprature du circuitretour dsire est rgle via le slecteur rotatif (4), l'activationtant effectue par potentiomtre dans la plage de 10 C min. 40 C max. La pompe chaleur sarrte lorsque la tempraturergle est atteinte et se remet en marche lorsque la temprature

    du circuit retour descend de 1 degr Kelvin au-dessous de la va-leur rgle. Un renclenchement de la pompe chaleur nestpossible quaprs une priode minimale d'inactivit de 20 minu-tes (aprs dgivrage de lvaporateur). La pompe chaleur sar-rte lorsque la temprature du circuit dpart atteint 45 C environou lorsque la temprature extrieure de l'air est trop basse (limiteinfrieure dutilisation -10 C).

    9 Nettoyage / entretien

    9.1 EntretienAfin de protger lenduit, viter dappuyer ou de dposer des ob-jets sur lappareil. Les parties extrieures de la pompe chaleurpeuvent tre essuyes avec un linge humide et des produits net-

    toyants usuels disponibles dans le commerce.

    ATTENTION !Ne jamais utiliser de produits dentretien contenant du sable, de la soude,de lacide ou du chlore, car ils attaquent les surfaces.

    Pour viter tout dysfonctionnement d des dpts danslchangeur thermique titane de la pompe chaleur, veiller ceque l'changeur de chaleur de la PAC ne puisse pas sencrasser(un traitement de leau ou une insta