FINAL ELECTRICA.docx
Transcript of FINAL ELECTRICA.docx
DISEO DE ILUMINACION1ER PISOI. COCINAA. AREA
S = a * b = 3 *4 = 12 m2 Area del ambiente
B. INDICE LOCAL
C- INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30D- FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 POR TABLA = n = 0.26 PAREDES = 0.50 PISO = 0.30
E- FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F- ILUMINARIA MEDIA En tabla, de cocina general = 300 lux
G- FLUJO TOTAL T = = = 23,076.923 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H- NUMERO DE LUMINARIAS
N = = = 1.846 = 2 LUMINARIAS
LAMPARAS HID(CDM-TD 150/83)
II. COMEDORA. AREA
S = a * b = 3.55 *5.4 = 19.17 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1.2 TECHO = 0.30 POR TABLA = n = 0.30 PAREDES = 0.50 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 200 lux
G. FLUJO TOTAL T = = = 21300 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.71 = 1 LUMINARIAS
SODIO DE ALTA PRESION OVOIDE (SON Plus 250W)
III. SALAA. AREA
S = a * b = 5.55 *4 = 22.2 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1.3 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.32 PAREDES = 0.50 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
G. FLUJO TOTAL T = = = 11562.5 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.8894 = 1 LUMINARIAS
HALOGENURO METALICO DE BAJA POTENCIA(MHW-TD 150W)
IV. SALA ESTUDIOI. AREA
S = a * b = 3.1 *3.65 = 11.315 m2 Area del ambiente
J. INDICE LOCAL
K. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.10
L. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.50 PISO = 0.10
M. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
N. ILUMINARIA MEDIA En tabla, de cocina general = 500 lux
O. FLUJO TOTAL T = = = 36266.025 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
P. NUMERO DE LUMINARIAS
N = = = 0.6716 = 1 LUMINARIAS
SODIO DE ALTA PRESION OVOIDE(SON Plus 400W) V. BAOQ. AREA
S = a * b = 1.85 *1.0973 = 2.03 m2 Area del ambiente
R. INDICE LOCAL
S. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30
T. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.50 PISO = 0.30
U. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
V. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
W. FLUJO TOTAL T = = = 1301.28 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
X. NUMERO DE LUMINARIAS
N = = = 0.7229 = 1 LUMINARIAS
FLUORECENTE COMPACTA(PLC/2p 18/84)
2DO PISOl. SALA STARA. AREA
S = a * b = 2.55 *3.1 = 7.905 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 POR TABLA = n = 0.26 PAREDES = 0.50 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
G. FLUJO TOTAL T = = = 5067.307 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.7677 = 1 LUMINARIAS
SODIO DE ALTA PRESION TUBULAR(SON-T Plus 70W)
al. DORMITORIO PRINCIPAL
A. AREA
S = a * b = 3.1 *5.1507 = 15.97 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.30 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1.4 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.31 PAREDES = 0.30 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 50 lux
G. FLUJO TOTAL T = = = 4293.01 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.987 = 1 LUMINARIAS
SODIO DE ALTA PRESION OVOIDE(SON-T Plus 50W)
al. DORMITORIO 1
A. AREA
S = a * b = 3.15 *4.1 = 12.915 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.30 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1.3 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.32 PAREDES = 0.30 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 50 lux
G. FLUJO TOTAL T = = = 3363.28125 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.773 = 1 LUMINARIAS
SODIO DE ALTA PRESION OVOIDE(SON-T Plus 50W)
lll. DORMITORIO 2
I. AREA
S = a * b = 3.55 *4.1 = 14.555 m2 Area del ambiente
J. INDICE LOCAL
K. INDICE LOCAL
Techo = 0.30 Paredes = 0.30 Piso = 0.10
L. FACTOR DE UTILIZACION (n)
K= 1.4 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.31 PAREDES = 0.30 PISO = 0.10
M. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
N. ILUMINARIA MEDIA En tabla, de cocina general = 50 lux
O. FLUJO TOTAL T = = = 3912.634 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
P. NUMERO DE LUMINARIAS
N = = = 0.899 = 1 LUMINARIAS
SODIO DE ALTA PRESION OVOIDE(SON-T Plus 50W)
lV. BAO 1
A. AREA
S = a * b = 2.8 *2.05 = 5.74 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30
D. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.30 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
G. FLUJO TOTAL T = = = 3679.487 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.845 = 1 LUMINARIAS
FLUORECENTE COMPACTA(PLC/2p 18/84)
lV. BAO 2I. AREA
S = a * b = 2.4 *1.9 = 4.56 m2 Area del ambiente
J. INDICE LOCAL
K. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30
L. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.30 PISO = 0.10
M. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
N. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
O. FLUJO TOTAL T = = = 2923.07 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
P. NUMERO DE LUMINARIAS
N = = = 0.68 = 1 LUMINARIAS
FLUORECENTE COMPACTA(PLC/2p 18/84)
3ER PISO
I. DORMITORIO 1
A. AREA
S = a * b = 3 *2.85 = 8.55 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.30 Piso = 0.10
D. FACTOR DE UTILIZACION (n)
K= 1.27 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.284 PAREDES = 0.30 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 50 lux
G. FLUJO TOTAL T = = = 2508.8 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 0.865 = 1 LUMINARIAS
FLUORECENTE COMPACTA(PLL/4p 36/84)
ll. BAO A. AREA
S = a * b = 2.55 *1.1 = 2.808 m2 Area del ambiente
B. INDICE LOCAL
C. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30
D. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.30 PISO = 0.10
E. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
F. ILUMINARIA MEDIA En tabla, de cocina general = 100 lux
G. FLUJO TOTAL T = = = 1800 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
H. NUMERO DE LUMINARIAS
N = = = 1 LUMINARIAS
FLUORECENTE COMPACTA(PLC/2p 26/83)
lll. TRABAJO DOMESTICOI. AREA
S = a * b = 4.55 *2.25 = 10.2375 m2 Area del ambiente
J. INDICE LOCAL
K. INDICE LOCAL
Techo = 0.30 Paredes = 0.50 Piso = 0.30
L. FACTOR DE UTILIZACION (n)
K= 1 TECHO = 0.30 INTERPOLANDO POR TABLA = n = 0.26 PAREDES = 0.30 PISO = 0.10
M. FACTOR DE MANTENIMIENTO (Fm)
Cogeremos el mas desfaborable para tener un valor mayor al necesario = 0.6 (sucio)
N. ILUMINARIA MEDIA En tabla, de cocina general = 300 lux
O. FLUJO TOTAL T = = = 19687.5 lumenes
E = Iluminacion mediaS = Arean= factor de utilizacionFm = Factos de mantenimiento
P. NUMERO DE LUMINARIAS
N = = = 0.89 = 1 LUMINARIAS
MERCURIO(HPLN 400W)