P R O D U C T O V E R V I E W
P R O D U C T O V E R V I E W
DIMENSIONS
Features: Two-piece die-cast aluminum ballast housing mounted to galvanized steel
trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion
features vertical and horizontal aiming scale with vertical repositioning stop.
All external hardware is stainless steel.
White corrosion resistant polyester powder finish standard; other architectural
colors available.
Heavy-gauge anodized reflector with six distributions available. “Flux man-
ager” available for optimal glare and spill light control. Transverse mounting
of lamp. Lamp support included. Optical chamber sealed to inhibit entrance of
contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered
glass. Lens frame is galvanized and secured by stainless steel spring clips for
servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014.
Fixture mounted by securing trunnion directly to cross arm. Mounting hard-
ware provided.
Suitable for -30°C MH / -40°C HPS
UL listed, suitable for wet locations. Below horizontal aiming orientation only.
Listed and labeled to comply with Canadian Standards.
All electrical components warranted by American Electric Lighting’s 6-year
guarantee.
Applications: Stadiums
Sports fields
Arenas
Tracks
Courts
AmeriSport™ Series ASP
Sports Floodlight400W,1000W,1500W MH
-
8/18/2019 Estudio de Iluminación - Planos Aucas
2/12
O R D E R I N G I N F O R M A T I O N
AmeriSport™ Series ASP
Sports Floodlight 400W,1000W,1500W MH
Example: A S P X 5 M C A M T 1 G N
Optics/ Distribution
ASP AmeriSport
Series
G General Purpose
H Heavy Duty
Ballast
CA CWA 2
SC SCWA
(Pulse Start)
Notes:
1 When ordered with metal halide, these wattages do notcomply with California Title 20 regulations.
2 CA ballast not available with 175W - 400W metal halide in
the U.S.; must use SC
3 Voids UL and CSA Listing; not available in MT TT
Voltage
120 120V
208 208V
240 240V
277 277V
347 347V
480 480V
MT1 Multi-tap Wired 120V
MT2 Multi-tap Wired 240V
MT7 Multi-tap Wired 277V
TT3 Tri-tap Wired 277V
5T4 5-tap Wired 480V
Listing
(blank) UL Listed (standard)
CS CSA Certified
XL No Listing
Fusing 3
Lamp
LC Lamp Included, Clear
(Ships separately)
Filter
CF Charcoal Filter 4
Options
N Narrow Beam
M Medium Beam
W Wide Beam
NX Narrow Beam with
Flux Manager DX Medium Beam with
Flux Manager
WX Wide Beam with
Flux Manager
Wattage / Source
40 400W 1
X1 1000W
X5 1500W
M Metal
Halide 2
See ballast matrix for
EISA compliant options
-
8/18/2019 Estudio de Iluminación - Planos Aucas
3/12
P H O T O M E T R I C S
ASP X1M G NASP X5M G W X ASP X5M G W
AmeriSport™ Series ASP
Sports Floodlight 400W,1000W,1500W MH
B A L L A S T M A T R I X
ASPWatts 120 208 240 277 347 480 MT1 MT2 MT7 TT340M SC SC SC SC SC SC SC SC SC -
X1M CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SCX5M CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC CA,SC
-
8/18/2019 Estudio de Iluminación - Planos Aucas
4/12
LuminaireSchedule
S ym bo l Q ty L ab el A rr an ge me nt T ot al L am p L um en s L LF D es cr ip ti on
4 32 Na r S ING LE 1 65 00 0 0 .70 0 T SP 1 50 0M G P2 4N
Calculation Summary
Label CalcType Units A v g M ax Mi n Avg/Mi n Max/Mi n #Pts CV UG MeterZ
CalcPts Illuminance Lux 2533 3010 1778 1.40 1.68 126 0.13 1.38 N.A
1 939 26 23 262 1 273 4 2 58 2 2 43 5 2 348 2 235 22 70 25 07 27 32 26 39 27 13 213 4
20 96 28 88 284 6 288 2 2 96 3 2 98 3 2 982 2 991 29 96 30 08 29 55 28 66 29 47 223 0
21 34 27 52 266 9 260 7 2 75 0 2 87 1 2 932 30 05 30 00 28 77 26 96 26 46 26 87 213 8
1 964 23 96 233 7 229 0 2 36 0 2 44 0 2 510 2 582 25 60 24 56 23 28 22 74 22 78 19 01
1 844 21 85 215 3 212 0 2 17 0 2 26 4 2 344 2 393 23 44 22 20 21 10 20 51 20 51 1778
1 958 23 84 232 6 229 2 2 35 5 2 43 2 2 490 2 528 24 95 23 92 22 72 22 26 22 59 19 36
21 21 27 23 265 9 262 9 2 74 9 2 85 8 2 901 2 940 29 12 27 79 26 13 25 79 26 65 222 4
2056 2802 2837 2958 3001 2982 2977 3005 3010 3009 2962 2830 2893 2314
1 885 25 01 259 4 285 9 2 68 1 2 47 7 2 421 2 430 24 82 26 67 28 65 26 24 26 12 212 8
-
8/18/2019 Estudio de Iluminación - Planos Aucas
5/12
LuminaireSchedule
S ym bo l Q ty L ab el A rr an ge me nt T ot al L am p L um en s L LF D es cr ip ti on
432 Nar SINGLE 165000 0.700 TSP 1500M GP24N
-
8/18/2019 Estudio de Iluminación - Planos Aucas
6/12
-
8/18/2019 Estudio de Iluminación - Planos Aucas
7/12
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 33
Ing. Fernando Orbea
VERSION A 24/06/20151
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.
01 02
DIAGRAMA UNIFILAR
-
8/18/2019 Estudio de Iluminación - Planos Aucas
8/12
3000
300 3000 300
3600
1000 1620380
2 0 0 0
2 6 0 0
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 33
Ing. Fernando Orbea
VERSION A 24/06/20151
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.
03 04
PRINCIPAL Y SECUNDARIO
-
8/18/2019 Estudio de Iluminación - Planos Aucas
9/12
ESTRUCTURA
DE LA TAPAVISTA SUPERIOR VISTA DE CORTE A - A'
1
3
2
4
5
15
EN ACERAS 2" X 1/4"EN CRUCE DE CALLES 5" X 1/4"
1
PROFUNDIDAD DE 1000 mm.
LAS DIMENSIONES ESTAN EXPRESADAS EN MILIMETROS.
NOTA:
10
5
A A'
15
15
15
15
10
10
10 1 5 15 15 15 15 10
5
5
5
850
900
9 0 0
1 0 0
50
2
VARILLA DE HIERRO:EN ACERAS 1/2"EN CRUCE DE CALLES 5/8"
3
4
DUCTOS5
50
1 1 0
3 5 0
1 0 0
2 8 0
2 0 0
1 1 0
800
1 0 0
100
8 0 0
7 0
3 1 0
110 110
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 33
Ing. Fernando Orbea
VERSION A 24/06/20151
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.
01 02
VEHICULAR Y PEATONAL
-
8/18/2019 Estudio de Iluminación - Planos Aucas
10/12
PUERTA1
PUERTA2
PUERTA3
PUERTA9
PUERTA5
PUERTA6
PUERTA7
PUERTA8
1 9 5
. 2 6
2 6 3 .7 8
2 0 3 .7 8
INGRESO
PUERTA3
INGRESOPUERTA2
INGRESO
PUERTA1
INGRESO
PUERTA8
INGRESO
PUERTA7
INGRESO
PUERTA6
INGRESOPUERTA5
INGRESO
PRINCIPAL
INGRESO
SECUNDARIO
INGRESOSECUNDARIO
I
NIVEL +2885
NIVEL +2886
NIVEL +2884
NIVEL +2882.50
NIVEL +2881
NIVEL +2880
NIVEL +2879.40
A R E A D E
C A M E R I N
O S
Y O F I
C I N
A S
N I V E L + 2 8 8 5
NIVEL +2891
N I V E L
+ 2 8 8 4 . 4 0
NIVEL +2885
INGRESO
PUERTA9
6 8 .0 4
6 3
. 0 3
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 33
Ing. Fernando Orbea
VERSION A 24/06/20151
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.
01 02
PERFORACIONES PARA ESTUDIO DE SUELO
-
8/18/2019 Estudio de Iluminación - Planos Aucas
11/12
L A V A M A N O
S
S S H H
M U
J E
R E S
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 33
Ing. Fernando Orbea
VERSION A 24/06/20151
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.
01 02
-
8/18/2019 Estudio de Iluminación - Planos Aucas
12/12
300
2 0
6 0
1 9 0
150
2000
2 0 0
1 6 9
4 6
1 0 0
47
4 6
2 0 0 0
1 2 0 0
400 1200 400
1 0 0
105 100 100 84 98 100 100113 100 100 100 100 100 100 98 113 84 1 00 100 105
2000
100
2 0 0
4 0
300
2 0
6 0
1 9 0
150
1 0 7 0
1 0 7 0
1 0 6 0
1 9 0
3 2 0 0
Escala 1: 20 Dimensiones en mm.
1 4 0
140
15
91 1 2 0
1 5
6
1 0
1 1
1 3
1 9
3 5
1 9
1 3
1 1
1 0
10 11 13 19 34 19 13 11 10
R = 6
1 5
Vr.
4 0
20
1
Escala 1:10 Dimensiones en mm.
01 ...
DETALLES DE POSTE METALICO
PLACA DE ANCLAJE
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4 5 6 7 8
DIBUJO NO:
PROYECTO: DIBUJO TITULO:DIBUJADO
REVISADO
=
REV. FECHA
FECHA
HOJA:
TOTAL:
SIGUIENTE:
+
APROBADO
FECHA
FECHA A1REV: 1 1
Ing. Daniel Game
Ing. Tito klaereVERSION A 24/06/20151
PIEA-ESTRUCTURAL-01
24/06/2015
24/06/2015
24/06/2015Ing. Wilfrido Veintimilla
MAPRIE S.A.