MEMORIA DE CÁLCULO
PRIMER NIVEL: Modulo Elasticidad ( Em ): 25,000 kg/cm2
PROPIEDADES DE MUROS DE ALBAÑILERIA ( EJE X - X ) Densidad ( ): 1,900 kg/cm2
Nivel Eje Nombre(Id.) Largo( cm ) Alto( cm ) Espesor( cm ) Masa( Kg. ) Dist. Eje Y( m ) Rigidez ProductoKx.Yi Prod. M.Yi
N X Y1 - Y2 L H T M Yi Kx Kx.Yi M.Yi
1 A - D m1x 220 240 15 1,504.80 5.03 44,295.79 222,586.36 7,561.62
2 B - D m2x 200 240 15 1,368.00 5.03 35,673.52 179,259.42 6,874.20
3 C - F m3x 220 240 25 2,508.00 2.23 73,826.32 164,263.57 5,580.30
4 E - D m4x 400 240 15 2,736.00 0.08 140,765.77 10,557.43 205.20
8,116.80 294,561.40 576,666.78 20,221.32
PROPIEDADES DE MUROS DE ALBAÑILERIA ( EJE Y - Y )
Nivel EjeNombre
(Id.)Largo( cm )
Alto( cm )
Espesor( cm )
Masa( Kg. )
Dist. Eje X( m )
RigidezProducto
Ky.XiProd. M.Xi
N Y X1 - X2 L H T M Xi Ky Ky.Xi M.Xi
A 1 - 2 m1y 510 240 15 3,488.40 0.08 205,072.91 15,380.47 261.63
B 3 - 6 m2y 300 240 25 3,420.00 3.73 140,512.59 523,409.40 12,739.50
C 6 - 8 m3y 510 240 15 3,488.40 6.73 205,072.91 1,379,115.30 23,459.49
10,396.80 550,658.40 1,917,905.17 36,460.62
Centro de Gravedad:
Xcg: 3.51 - 2.49
Centro de Rigideces:
Xcr : 3.48 - 1.96
Excentricidad generada:
ex -t : -0.02 - -0.53
Excentricidad accidental:
e x- acc.: 0.68 - 0.51 A= 5.1 m ex -t : 0.34 Ok !!
Excentricidad a considerar ( + ):
ex -d: 0.64 - -0.29 B= 6.8 m ey -t : 0.255 Error…!
Excentricidad a considerar ( - ):
ex -d: -0.72 - -1.31
*Nota: Verificar que la excentricidad generada siempre sea menor que laexcentricidad accidental.
Ycg:
N1
Muro entre Ejes
Muro entre Ejes
N1
ey -d:
Ycr :
ey -t :
ey- acc.:
ey -d:
_________________________________
Hills and Lenz Company SAC
www.hlcia.net | [email protected]
LIMA‐PERU
Muros en 1er Nivel verif. corte
Ing. Hiroyasu
![Page 3: Cortante en Muros de Albañileria](https://reader036.fdocuments.ec/reader036/viewer/2022082601/5695cf7a1a28ab9b028e4364/html5/thumbnails/3.jpg)
7/23/2019 Cortante en Muros de Albañileria
http://slidepdf.com/reader/full/cortante-en-muros-de-albanileria 3/4
MEMORIA DE CÁLCULO
PRIMER NIVEL:
FUERZA CORTANTE ABSORBIDA EN MUROS DE ALBAÑILERIA ( EJE X - X )
Nivel Eje Nombre(Id.) F. cortante ennivel ( Kg.) M. Torsor ennivel (Kg - m) d i Kd i2
N X Y1 - Y2 Fv Mt Yi-Ycr F.C. Basal F.C. Torsor F.C. total
1 A - D m1x 24,939.00 32,679.27 3.07 416,745.78 3,750.30 765.25 4,515.55
2 B - D m2x 24,939.00 32,679.27 3.07 335,625.26 3,020.29 616.30 3,636.59
3 C - F m3x 24,939.00 32,679.27 0.27 5,274.31 6,250.50 111.14 6,361.64
4 E - D m4x 24,939.00 32,679.27 -1.88 498,959.68 11,917.91 1,492.69 13,410.61
1,256,605.04 24,939.00 2,985.38 27,924.38
5,802,077.83
PROPIEDADES DE MUROS DE ALBAÑILERIA ( EJE Y - Y )
Nivel EjeNombre
(Id.)F. cortante en
nivel ( Kg.)M. Torsor ennivel (Kg - m)
d i Kd i2
N Y X1 - X2 Fv Mt Xi-Xcr F.C. Basal F.C. Torsor F.C. total
A 1 - 2 m1y 24,939.00 32,679.27 -3.41 2,381,715.30 9,287.63 3,936.30 13,223.93
B 3 - 6 m2y 24,939.00 32,679.27 0.24 8,233.68 6,363.73 191.58 6,555.31
C 6 - 8 m3y 24,939.00 32,679.27 3.24 2,155,523.81 9,287.63 3,744.72 13,032.35
4,545,472.79 24,939.00 7,872.59 32,811.59
5,802,077.83
Fuerza cortante aplicada en el mur o ( X )
Fuerza cortante aplicada en el mur o ( Y )
Muro entre Ejes
N1
Muro entre Ejes
N1
_________________________________
Hills and Lenz Company SAC
www.hlcia.net | [email protected]
LIMA‐PERU
Muros en 1er Nivel verif. corte
Ing. Hiroyasu
![Page 4: Cortante en Muros de Albañileria](https://reader036.fdocuments.ec/reader036/viewer/2022082601/5695cf7a1a28ab9b028e4364/html5/thumbnails/4.jpg)
7/23/2019 Cortante en Muros de Albañileria
http://slidepdf.com/reader/full/cortante-en-muros-de-albanileria 4/4
MEMORIA DE CÁLCULO
PRIMER NIVEL:
RESISTENCIA AL CORTANTE EN MUROS DE ALBAÑILERIA ( EJE X - X )
Nivel Eje Nombre(Id.) F. cort ante (Kg.) Area decorte (cm2) Esfuerzo decort. en muro Fuerza deCompresión Esfuerzo Adm.al corte Observaciones
N X Y1 - Y2 Fvm Av (Kg/cm2) (Kg ) Adm (Kg/cm2) Obs.
1 A - D m1x 4,515.55 3,300.00 1.37 1.80 Ok!
2 B - D m2x 3,636.59 3,000.00 1.21 1.80 Ok!
3 C - F m3x 6,361.64 5,500.00 1.16 1.80 Ok!
4 E - D m4x 13,410.61 6,000.00 2.24 1.80 Verificar
PROPIEDADES DE MUROS DE ALBAÑILERIA ( EJE Y - Y )
Nivel EjeNombre
(Id.)F. cort ante (
Kg.)Area de
corte (cm2)Esfuerzo de
cort. en muroFuerza de
CompresiónEsfuerzo cort.
Adm.Observaciones
N Y X1 - X2 Fv Av (Kg/cm2) (Kg ) Adm (Kg/cm2) Obs.
A 1 - 2 m1y 13,223.93 7,650.00 1.73 1.80 Ok!
B 3 - 6 m2y 6,555.31 7,500.00 0.87 1.80 Ok!
C 6 - 8 m3y 13,032.35 7,650.00 1.70 1.80 Ok!
Muro entre Ejes
N1
Muro entre Ejes
N1
_________________________________
Hills and Lenz Company SAC
www.hlcia.net | [email protected]
LIMA‐PERU
Muros en 1er Nivel verif. corte
Ing. Hiroyasu