8/17/2019 CERTIFICACION TAPONES 3M
1/3
Januray18,2002
HearingProtectiveDevice Test Report NumberQ307A Revision
1/9/02
1/10/02-1/17/02
Date of SampleReceipt
Date of SampleTest:
3M OH&ESD.
Attn: Ted Madison
3M Center,Building 260-3B-
SaintPaul MN 55144-1000
Attenuationmeasurementsavebeenperfomled according o the AmericanNational Standards
Institute (ANSI) Specifications,ANSI S3.19-1974, sing he experimenter-fitprotocol, on the
3M corded1270 78-8124-2450-1ev1) (test ll Q307A). The specified hresholdmeasurement
datawere obtainedusing ten nomlal-hearing isteners,six male and our female,with ages
ranging rom 19 o 45 years. These istenerswere selected rom a standbygroup of about35
volunteers,mostly graduate tudents,who regularly serveas isteners or measurementsf this
kind.
The measurements ere made n a room designed or this purpose. All acoustic
characteristics f the room meet he requirements utlined n ANSI S3.19-1974. The ambient
noise evels n this room arebelow the limits specified n ANSI S3.19-1974, nd openear
thresholdsare usedon a continuingbasis o monitor the background oise evels. An automatic
recordingattenuatorwas used o recordboth open and occludedear hresholds.
Eachoften subjectswas ested hree imes at eachof nine test requencies.The attached
Tablesshow grandmeanattenuation alues n decibels dB) for each est signal along with group
attenuation alues. Standard eviations S.D.) for the 30 different attenuation eterminationsor
each est signal are also given. The resultspresentedn this reportpertain o the samples ested
only.
Michael & Associatess accredited y the National Institute of Standards nd
Technology NIST) National LaboratoryAccreditationProgram NVLAP) for testsperfonIled
according o ANSI S3.19-1974 ndANSI S12.6-1984.Theseaccreditation riteria encompass
the requirements fintemational standardsSO 9002:1994 ANSI / ASQC Q92-1987), SO IEC
Guide25:1990,and SO / IEC Guide 58:1993as suppliersof test results. This report may only
be reproduced r transmittedelectronically n it's entirety. This report shall not be used o claim
product endorsement y NVLAP or by any agencyof the U.S. Government.All measurement
equipmentare calibratedwith instrumentationraceable o the NIST.
Use hese aboratory-derivedattenuationdata or comparison urposesonly. Theamountof
protect:on afforded n ield use s often significantly ower depe.flding n how theprotectors are
fitted and worn.
-
Date
Page
of3
Kevin Michael, Ph.D.
President
8/17/2019 CERTIFICACION TAPONES 3M
2/3
Individual and Summary Attenuation Data for
Hearing Protective Devices
Position: Insert
Date: 1/18/02
Test ID
Test Method: ANSI S3.19-1974
Manufacturer: 3M
Model: 78-8124-2450-1 (rev 1)
0307A
FREQUENCY IN HERTZ
SUBJECT
125
250 500
1000 2000
3150
4000
6300 8000
31
27
35
20
23
23
26
21
21
28
30
31
29
27
24
27
28
26
33
30
32
26
25
29
33
32
35
36
37
39
31
25
34
21
24
22
29
26
25
31
31
30
29
29
29
26
26
26
35
28
33
29
30
31
36
32
41
39
38
39
31
33
36
23
24
24
30
30
33
33
32
28
38
32
38
28
28
31
39
33
34
34
35
37
33
33
41
33
41
38
30
34
32
29
30
31
37
32
30
37
36
30
40
43
36
32
32
33
40
42
35
28
27
31
34
35
37
33
35
34
33
35
37
32
32
31
40
38
33
40
41
32
33
36
35
36
32
33
38
38
37
29
28
28
35
39
36
30
35
33
31
38
31
31
35
34
35
36
34
39
40
34
35
36
38
38
31
34
36
39
36
33
31
35
38
41
30
38
42
41
38
44
37
36
35
36
35
39
35
37
41
35
34
32
30
36
35
36
30
37
32
36
31
37
33
36
33
41
46
45
46
46
43
32
36
37
41
37
36
45
46
43
35
36
34
36
33
37
41
40
35
40
38
43
43
42
50
41
42
44
47
49
47
31
37
35
38
40
40
42
44
43
39
37
47
36
35
38
40
41
40
51
51
52
46
46
47
40
43
47
1
2
3
4
5
6
7
8
9
10
MEANS
STD. DEV.
28.7
5.0
30.1
5.0
32.8
4.6
33.8
4.1
34.5
3.5
35.6
3.4
36.2
4.0
39.9
4.5
42.2
5.3
NRR = 24 dB
Use these laboratory-derived data for comparison purposes only. The amount of
protection afforded in field use is often significantly lower depending on how the
protectors are fitted and worn.
Page 2 of 3
8/17/2019 CERTIFICACION TAPONES 3M
3/3
Date:
Test ID:
1/18/02
Q307A
Manufacturer: 3M
Model: 78-8124-2450-1 (rev 1)
Position: Insert
Measurements were made according to American National Standards Institute
Specifications ANSI S3.19-1974.
Center Frequency Mean Attenuation
in Hz . in dB
Group Attenuation
in dB .
Standard Deviation
in dB
125
250
500
1000
2000
3150
4000
6300
8000
28.7
30.1
32.8
33.8
34.5
35.6
36.2
39.9
42.2
58.9
5.0
5.0
4.6
4.1
3.5
3.4
4.0
4.5
5.3
172.9
82.1
Test Item: Q307A
These data were obtained through measurements made at the laboratories
of Michael & Associates, Inc., State College, PA, USA. Michael & Associates,
Inc., is accredited to test to ANSI S3.19-1974 and ANSI S12.6-1984 by the
National Institute of Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Program (NVLAP).
Date
Page 3 of 3
Kevin L. Michael, Ph.D.
President