TECNICAS GEOELECTRICAS PARA DETECCION DE FUGAS SOBRE GEOMEMBRANAS EN
MINERIA
Expositor: Ing. Luis Tobar G.
SERVICIO (Leak Location Survey)
CONTROL DE
CALIDAD FINAL (Integrity Survey)
MEMBRANA
EXPUESTA
MEMBRANA
CUBIERTA
CONDICIÓN
ASTM D7703
ASTM D7002
ASTM D7240
ASTM D7007
ASTM D7007 ASTM D7240
Bipolar (Suelos)
ASTM D7953
Spark Testing
Arc testing
Bipolar (Agua)
Lanza de Agua
Charco de Agua
MAPA SINOPTICO: TDM-LIS
Por lo que resulta de vital importancia velar por la
integridad en estos sistemas
“Por una Minería moderna, limpia e inclusiva”
SISTEMA DE IMPERMEABILIZACION
Water Lance
METODOS
GM Cover water
METODOS
Water Puddle
METODOS
Spark Testing
METODOS
GM Cover Earth
METODOS
ARC Testing
METODOS
Sistema de Contención Secundario Sistema de conducción (canales)
Diques de Retención Estructura de Producción (Leach Pad)
APLICACIONES
Plataforma de Lixiviación
APLICACIONES
Sistema de Contención - Uso Agrícola
APLICACIONES
Sistema de Almacenamiento residuos Solidos
APLICACIONES
• ASTM D4439 - Terminology for Geosynthetics
• ASTM D6747-04 - Standard Guide for selection of techniques for electrical detection of
potencial leak paths in geomembranes
• ASTM D7002-10 - Standard Practices for electrical Leak Location on Exposed
geomembranes using the Water Puddle system
• ASTM D7007-09 - Standard Practices for Electrical Methods for locating leaks in
geomembranes covered with water or earth materials (Dipolo System)
• ASTM D7703-11 - Standard Practices for electrical Leak Location on Exposed
geomembranes using the Water Lance system
• ASTM D7240-06/11 - Standard Practice for Leak Location using Geomembranes with an
Isulanting Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance
Technique (Conductive Geomembrane Spark Test)
• ASTM D7953-14 - Standard Practice for Electrical Leak Location on exposed
Geomembranes using the Arc Testing Method.
NORMATIVIDAD
SERVICIO (Leak Location Survey)
CONTROL DE
CALIDAD FINAL (Integrity Survey)
MEMBRANA
EXPUESTA
MEMBRANA
CUBIERTA
CONDICIÓN
ASTM D7703
ASTM D7002
ASTM D7240
ASTM D7007
ASTM D7007 ASTM D7240
Bipolar (Suelos)
ASTM D7953
Spark Testing
Arc testing
Bipolar (Agua)
Lanza de Agua
Charco de Agua
MAPA SINOPTICO: TDM-LIS
Ing. Luis Tobar G. Sub. Gerente TDM Ingenieria Alameda Los Horizontes_905 Urb. Los Huertos de Villa_Chorrillos Lima_Perú T. (511) 617 4700 | ANX: 4749 | F. (511) 617 4701 Cel: 949108885 www.grupotdm.com
SÍGUENOS EN:
Top Related