GeométricaAño Población1980 1780 K80-91 0.0151991 2105 K91-01 0.0162001 2468 K01-10 0.0182010 2895 kprom= 0.016
2010 2895 2895 28952014 3090 3027 30232024 3637 3356 35332034 4281 3685 4128
Años Caudales l/día m3/hora c= 0.0038
2014
Qmd= 901952.89 37.58 Def2014= 233.52QMd= 1217636.40 50.73 Dbr2014= 291.89QMh= 2130863.70 88.79
2024
Qmd= 898840.93 37.45 c= 0.0037 QMd= 1213435.25 50.56 Def2024= 242.20QMh= 2123511.69 88.48 Dbr2024= 247.15
2034
Qmd= 1339522.79 55.81 c= 0.0033QMd= 1808355.77 75.35 Def2034= 250.35QMh= 3164622.60 131.86 Dbr2034= 312.931664
Geometrica (Int.
Compuesto)
Lineal (proy aritmetica)
Log (proy geometrica)
Lineal Logarítmica
K80-91 29.55 K80-91 0.015K91-01 36.30 K91-01 0.016K01-10 47.44 K01-10 0.018kprom= 32.92 Promedio= 0.016
Dotacion al 2010 D2010= 230
K1= 1.35K2= 1.75
Capatciones de Aguas Superficiales.
Informacion para el diseño Vol de la Represa= Qm20 x 30 diasPeriodo de diseño= 20 años 30 dias es el periodo que se considera necesario para reparar daños ocacionados por una crecidaPoblacion =3090 habitantes *no se esta teniendo en cuenta perdida por EVT y las precipitacionesQm20= 1339522.79 l/diaVol de Repr= 40185.6837 (m3)Qcap = Vol de Represa / dias de llenadoDias de llenado= 2Qcap= 0.23 (m3/s)
^
Diseño de la PresaEl ancho de la presa 2.0 mLa lamina de agua en las condiciones de diseño es de:
L= 5H= 0.09
La correcion por las dos contracciones laterales esL´= L - 0.2 H 4.98
Velocidad del rio sobre la presaV= Q/L´ x H
V= 0.54 m/s0.3<0.51<3 Esta entre los limites de manera que puedan ser aplicables las ecuaciones siguientes
Diseño de la rejilla y el canal de aduccionEl ancho del canal de aduccion sera:
Xs= 0.39 m
Xi= 0.24 m
B= Xs + 0.10B= 0.49 m
Adopoto B= 0.50 m
La longitud de la rejilla y el numero de orificios sera:
Se adoptan barrotes del 1/2 pulgada (0.0127m) y separacion entre ellos de 5 cm.Tambien se supone la velocidad entre barrotes igual a 0.10 m/s.
An= Q / 0.9 Vb Vb= 0.15 m/sAn= 1.72 m2
An=(a /a +b )/B Lr
Lr= 4.32Adopto 4.35 m de longitud de rejilla.
Lr= 4.35An= 1.73 m2
El numero de orificios es:N=An/(a x B)
Xs=0.36 Vr2/3+0.60 H4/7
Xi=0.18 Vr4/7+0.74 H3/4
N = 69.38Se adopta 70 orificios separados cada 5 cm y se obtine lo siguiente:
An= 1.75 m2Vb= 0.15 m/sLr= 4.39 mLr= 4.40 m
Los niveles de agua en el canal de aduccion son:
Aguas abajos
he=he= 0.28 m falta terminar las formulas.
Aguas arribaLc=Lr + espesor del muro = 4.40 + 0.30 = 4.70 Lc= 4.70i= 5% ho=[2he2+(
he = hc = (Q2/(g B2))1/3
30 dias es el periodo que se considera necesario para reparar daños ocacionados por una crecida *no se esta teniendo en cuenta perdida por EVT y las precipitaciones
^
1970 1980 1990 2000 2010 2020 2030 20401200
1700
2200
2700
3200
3700
4200
4700Censos
Proy. Geometrica
Proy. Aritmética
Proy. Int. Comp.
Años
Pob
laci
ón
Pérdidas de Carga en la Impulsion:Datos de nivelesNivel del fondo del lago respecto al borde Nfondo= -8.5 mNivel minimo del lago (desde el borde) Nmin= -6.5 mNivel maximo del lago (desde el borde) Nmax= -2.5 mNivel de la camara de carga (respecto al borde) NCC= 5 mNivel minimo de la camara de bombeo NCB= -7.8
CotasCota del borde del lago Cborde= 155 m Obtenido del cad cota a orilla del dique de BaezCota de la camara de carga CCC= 160 mCota del nivel min del lago Cmin= 148.5 mCota del nivel max del lago Cmax= 152.5 mCota del fondo del lago Cfondo= 146.5 m
Debidas a la friccion
0.02093 75.35Diametro (D) = 160 mm
Diametro interno (Di) = 150.6 mm
Viscocidad Cinematica = 1.00E-06Rugosidad Absoluta = 7.00E-06 m
0.02302305 82.88
Numero de Reynolds176952
Factor de Friccion
0.016 0.0120.0168867480.01631279
0.016369121Velocidad 0.016363488
1.17 0.016364050.0163639940.0163639990.0163639990.016363999
Perdida de Carga Unitaria
0.00764585548
Perdida de Carga Total
0.3823 m
Caudal (QMd20) = m3/seg= m3/hora
m2/seg
Caudal de bombeo QMd20*1,10 = m3/seg = m3/hora
fadopt
m/seg
Re=v×Dυ
=
f=−[ 1
2×log [ 2 ,51Re×√ f
+ k3 ,71×D ] ]
2
=
V=4×Q
π×D2=
j= fD
× v2
2×g=
H f= j×L=
L= 50 Longitud de la impulsion adopto que la camara de carga se encuentra a esta longitud desde la camara de bombeo
DEBIDO A SINGULARIDADES:Longitud equivalente de los accesorios (Le = K*D)
CantidadValvula Exclusa: 1
K= 8 Le = 1.20 m1
Curva a 90K= 45 Le = 6.78 m
Valvula de retencion: 1K = 100 Le = 15.06 m
Curva a 45º (4 piezas) 4K= 15 Le = 9.04 m 32.08 0.25
Perdida de Carga Total 0.25 m
PERDIDA DE CARGA TOTAL EN LA IMPULSION:
0.63 m
CALCULO DE LA ALTURA MANOMETRICA:Alturas geometrica de impulsion: 11.50 m Perdida de carga en impulsion: 0.63 m
12.13 m
CALCULO DE LA POTENCIA DE LA BOMBA
5.32 H.P.
Calculo de la curva del sistemaLas perdidas de carga por friccion se calcularan con la ecuacion de Manning
Datos ImpulsionLongitud L = 50.00 mn de Manning n = 0.009
Htimp =
Hgimp =Htimp =
H f= j×L=
H l= j×Leq=
Hm=H gimp+H timp=
Nb=γ×Qb×Hm
η×76=
j =n2× V 2
R4
3
≡ n2×Q2
( π×d2
4 )2
×( d4 )4
3
=
Diametro D = 0.16 mDiamtro interno Di = 0.1506 m
AccesoriosValvula de retencion:K= 100 Le = 15.06 m
Curva a 90K= 45 Le = 6.78 m
Valvula Exclusa:K= 8 Le = 1.20 m
Curva a 45º (4 piezas)K= 15 Le = 9.04
Le tot = 32.08 m
La ecuacion de la curva del sistema debe ser:
Donde:
Altura geometrica total = 11.50 m
Perdida de carga total en funcion del Caudal
Planilla de calculo de curva de sistema
Impulsion
0 0.000000 0.0000 0.0000 11.5000 00.001 0.000020 0.0010 0.0006 11.5017 3.60.002 0.000081 0.0040 0.0026 11.5066 7.20.003 0.000182 0.0091 0.0058 11.5149 10.80.004 0.000324 0.0162 0.0104 11.5266 14.40.005 0.000506 0.0253 0.0162 11.5415 180.006 0.000728 0.0364 0.0234 11.5598 21.60.007 0.000991 0.0496 0.0318 11.5814 25.20.008 0.001295 0.0647 0.0415 11.6063 28.80.009 0.001639 0.0819 0.0526 11.6345 32.40.01 0.002023 0.1011 0.0649 11.6660 36
0.011 0.002448 0.1224 0.0785 11.7009 39.60.012 0.002913 0.1457 0.0934 11.7391 43.20.013 0.003419 0.1709 0.1097 11.7806 46.80.014 0.003965 0.1982 0.1272 11.8254 50.40.015 0.004552 0.2276 0.1460 11.8736 540.016 0.005179 0.2589 0.1661 11.9251 57.60.017 0.005846 0.2923 0.1875 11.9799 61.2
H = Hg + DHT(f(Q2))
Hg =
DHT(f(Q2))=
Q [m3/seg]
Ht[m]Q
[m3/h]jimp[m] Hfimp[m] Hlimp[m]
Datos para eleccion de bomba
11.50 mPotencia = 5.32 HP = 3.97 kW
82.88 23.02 l/s
De acuerdo a esto, se selecciona una bomba sumergible:FLYGT CT 3085 HT 250
Esta en el catalogo general pagina 72Curva del equipo de bombeo
Equipo de bombeo
h
0 25.5 3.2 0.000010 20.5 3.2 0.234120 17.9 3.2 0.408930 15.3 3.2 0.524340 12.3 3.2 0.562050 8.8 3.2 0.502660 4.7 3.2 0.3221
Punto de funcionamiento del sistema
Caudal 38Altura manometrica 13 mrendimiento 0.57Potencia 3.2 HP
Hm =
Qb = m3/hora =
Q[m3/h]Hm[m] Nabs [H.P.]
m3/h
Obtenido del cad cota a orilla del dique de Baez
19384.11169 0.01688674822994.72853 0.0163127922600.57045 0.01636912122639.55875 0.01636348822635.66291 0.0163640522636.0518 0.016363994
22636.01298 0.01636399922636.01685 0.01636399922636.01646 0.01636399922636.0165 0.016363999
fcalcRe×√f
Longitud de la impulsion adopto que la camara de carga se encuentra a esta longitud desde la camara de bombeo
0 5 10 15 20 25 30 35 40 45 50 55 600
5
10
15
20
25
30
0.00
0.10
0.20
0.30
0.40
0.50
0.60BOMBA LAGO
H-Q Bomba H-Q Sistema Rendimiento
Q[m3/h]
H[m
] Ren
dim
ient
o h
Captacion de aguas subterraneasEnsayos de BombeoCaracteristicas del pozo
N.E. (m) = 3.33 Nivel estaticoN.D. (m) = 8.72 Nivel Dinamico
82.88 Caudal de bombeo
5.45 Caudal unitarios (m) = 5.39 Depresion del pozo
d (m) 0.15 Diametro del pozot (min) = 1140 Tiempo total del ensayo de bombeo
ø 1,5 mm sedimento acuifero
ENSAYO DE BOMBEO
Tiempo de lectura
[min] [dias]
0 0 3.33 --- 0.00 ----1 0.0007 4.20 30.15 0.87 34.662 0.0014 4.83 30.15 1.50 20.103 0.0021 5.33 29.38 2.00 14.694 0.0028 5.69 29.38 2.36 12.456 0.0042 5.94 29.38 2.61 11.268 0.0056 6.19 29.38 2.86 10.27
10 0.0069 6.39 29.38 3.06 9.6015 0.0104 6.59 29.38 3.26 9.0120 0.0139 6.78 29.38 3.45 8.5225 0.0174 6.96 29.38 3.63 8.0930 0.0208 7.15 29.38 3.82 7.6940 0.0278 7.33 29.38 4.00 7.3550 0.0347 7.51 29.38 4.18 7.0360 0.0417 7.69 29.38 4.36 6.7490 0.0625 7.86 29.38 4.53 6.49
120 0.0833 8.03 29.38 4.70 6.25180 0.1250 8.19 29.38 4.86 6.05240 0.1667 8.34 29.38 5.01 5.86300 0.2083 8.48 29.38 5.15 5.70480 0.3333 8.58 29.38 5.25 5.60540 0.3750 8.64 29.38 5.31 5.53720 0.5000 8.69 29.38 5.36 5.48900 0.6250 8.71 29.38 5.38 5.46
1140 0.7917 8.72 29.38 5.39 5.45
Calculo de caracteristicas hidraulicas del acuiferoDatos
r (m)= 11 Sondeo del pozo
82.88 Caudal de bombeom (m)= 10 Espesor del acuifero
Metodo de Jacob ( del grafico depresion-tiempo)6.00 Se elijen los tiempo de modo tal que el log se hace igual a 1
Qb (m3/h) =
q (m3/h) =
Nivel del agua desde boca de pozo [m]
Caudal de bombeo
(m3/h)
Depresion s(m)
Caudal especifico (m3/h/m)
Qb (m3/h) =
t1 =
60.00
2.610
4.3601.750
8.67
208.04 Transmisibilidad
20.80 Permeabilidad
0.3 se prolonga la recta hasta s = 0S = 0.000806 Coeficiente de almacenamiento
Calculo de la eficiencia del pozoDatos
t (dias) = 1R (m) = 0.075 Radio del pozo
15.377
Capacidad especifica teorica CRT
Argumento de la funcion de pozo= 5.45E-09
Funcion de pozo W(u) = - 0,5772 – ln u = 19.03
Capacidad esp. teorica CET= 5.73
Longitud del filtro Lf (m) = 8
t2 =
s1'=
s2'=
Ds' =T (m3/h/m) =
T (m3/dia/m) =
k (m3/dia/m2) =
tO(min)=
Capacidad específica real CER [m 3/hr∙m]=
T=2,3⋅Q
4⋅π⋅Δs '
S=2 ,25⋅T⋅t0
r2
r Su
T t
2
4
Q T
s , W u
1 908
ENSAYO DE RECUPERACION
Tiempo Tiempo inicio bombeo "T+ t"( T+ t ) / t
[min] [min] [dias]
0 1140 0.79167 8.72 --- 5.3901 1141 0.79236 5.35 1141.00 2.0202 1142 0.79306 5.16 571.00 1.8303 1143 0.79375 5.07 381.00 1.7404 1144 0.79444 4.96 286.00 1.6305 1145 0.79514 4.90 229.00 1.5706 1146 0.79583 4.81 191.00 1.4808 1148 0.79722 4.72 143.50 1.390
10 1150 0.79861 4.61 115.00 1.28015 1155 0.80208 4.47 77.00 1.14020 1160 0.80556 4.36 58.00 1.03025 1165 0.80903 4.28 46.60 0.95030 1170 0.81250 4.22 39.00 0.89045 1185 0.82292 4.07 26.33 0.74060 1200 0.83333 3.94 20.00 0.61090 1230 0.85417 3.81 13.67 0.480
120 1260 0.87500 3.68 10.50 0.350150 1290 0.89583 3.64 8.60 0.310180 1320 0.91667 3.60 7.33 0.270210 1350 0.93750 3.53 6.43 0.200270 1410 0.97917 3.46 5.22 0.130330 1470 1.02083 3.33 4.45 0.000
Nivel del agua desde boca de pozo [m]
Depresión Residual
s'[m]
0 200 400 600 800 10000.00
1.00
2.00
3.00
4.00
5.00
6.00Depresion - Tiempo
T (minutos)
s (m
)
0.1 1 10 100 1000 100000.00
1.00
2.00
3.00
4.00
5.00
6.00
Depresión - Tiempolog T(minutos)
s (m
)
t0=0,3
1140 1190 1240 1290 1340 1390 14400.00
1.00
2.00
3.00
4.00
5.00
6.00Recuperación - Tiempo
t (minutos)
R (
m)
1000 100000.00
1.00
2.00
3.00
4.00
5.00
6.00Recuperación - Tiempo
log t(minutos)
R (
m)
1.00 10.00 100.00 1000.00 10000.000.00
1.00
2.00
Depresión residual vs (t+t')/t'
(log t+t'/t')
(m)
Calculo del diametro economico
DatosMaterial de tubería: PVC
Caudal (máximo diario): 0.020930
Tiempo de bombeo diario 16 hs
Caudal de bombeo 0.023023Longitud de la cañería L 150 mVida útil: n 20 añosInterés anual: i 15.00%
Costo unitario de excavación: C.U.E. 10
Cota de entrad 280 m
Cota de salida: 310 m
Peso específico del agua: 1000
Viscosidad cinemática: m 1.00E-06Rendimiento: h 0.7
Tiempo de bombeo anual: 5840 hs/año
*Costo unitario de energía: 0.309 $/KwhRugosidad absoluta: k 0.000007 mFactor p/Ec.Hazen-Williams (PVC): c 150
Tarifa Nº1 (pequeña demandas <10kw)T.1.G. Uso general - T.1.G2. Consumo bimestral mayor a 1600 Kwh. e inferior o igual a 4
Cargo fijo (haya o no cons Cargo variable: Cargo total:
Diametros
diametro [mm]Costo total (6m)costo/m serie polinomica
63 53.3 8.88 5.397 0.39 50 0.5075 72.3 12.05 6.765 0.4 63 0.5090 109.2 18.2 9.69 0.43 75 0.50110 152.86 25.48 15.69 0.46 90 0.50125 221.34 36.89 21.765 0.48 110 0.50140 306.08 51.01 29.19 0.39 125 0.50160 400.85 66.81 41.19 0.53 140 0.55200 626.58 104.43 72.39 0.6 160 0.55250 968.46 161.41 124.89 0.75 200 0.55315 1735.44 289.24 215.565 0.94 250 0.60355 2172.06 362.01 283.965 1.02 315 0.60400 2715.12 452.52 372.39 1.12 355 0.60500 4176.9 696.15 612.39 1.35 400 0.70
450 0.75
500 0.80
QMd20 m3/s
Tbd
Qb =1,10*QMd20 m3/s
$/m3
Hent
Hsal
gagua kg/m3
m2/seg
Tba = Tbd∙365
CEner
2009
Diamtro de cañeria
(mm)
Ancho de la zanjas
( m )Vol
excavacion [m3/m]
Øexterior [mm]
Øinterior [mm]
Precio de tuberia K6 x
6m
Precio de tuberia
($/m)
Costo de excavacio
n ($/m)
Costo Tuberia +
Excavación ($/m)
Costo de inversión
($)
CF=121. 80$
Kw⋅bim=0 . 084
$Kwh
CV=0 . 225$
Kwh CEner=CF+CV=0 . 309$
Kwh
63 59.2 53.3 8.88 6.56 15.45 2316.7575 70.6 72.3 12.05 6.63 18.68 2801.2590 84.6 109.2 18.2 6.70 24.90 3735.00
110 103.6 152.86 25.48 6.80 32.28 4842.00125 117.6 221.34 36.89 6.88 43.77 6564.75140 131.8 306.08 51.01 7.65 58.66 8798.25
1 160 150.6 400.85 66.81 7.76 74.57 11184.75200 188.2 626.58 104.43 7.98 112.41 16860.75250 235.4 968.46 161.41 9.00 170.41 25561.50315 296.6 1735.44 289.24 9.39 298.63 44794.50355 334.2 2172.06 362.01 9.63 371.64 55746.00400 376.6 2715.12 452.52 11.55 464.07 69610.50500 470.8 4176.9 696.15 12.75 708.90 106335.00
Costo anual minino= Camin= $ 2,525.06Diametro economico Decon= 160Diametro interno Di = 150.6
Øexterior [mm]
Øinterior [mm]
Precio de tuberia K6 x
6m
Precio de tuberia
($/m)
Costo de excavacio
n ($/m)
Costo Tuberia +
Excavación ($/m)
Costo de inversión
($)
tapada (m)
1.10
0.150 1.30 $ 10.00 6.5000.150 1.31 $ 10.00 6.5650.150 1.33 $ 10.00 6.6250.150 1.34 $ 10.00 6.7000.150 1.36 $ 10.00 6.8000.150 1.38 $ 10.00 6.8750.150 1.39 $ 10.00 7.6450.150 1.41 $ 10.00 7.7550.150 1.45 $ 10.00 7.9750.150 1.50 $ 10.00 9.0000.150 1.57 $ 10.00 9.3900.150 1.61 $ 10.00 9.6300.150 1.65 $ 10.00 11.550
0.150 1.70 $ 10.00 12.750
0.150 1.75 $ 10.00 14.000
Relleno de asiento (m)
Altura de la zanja
(m)
Precio ($/m3)
Precio lineal ($/m)
Costo de amortización
($)
J (m/m)
∆H (m)
N (kW)
E
(kW hs)
Costo de energía
($/kW x hs)
Costo de energía
consumida total
($)
Costo total
($)
347.51 0.912123 136.818 44.2797 ### 0.309 79958.4 80305.9420.19 0.386885 58.033 18.7816 ### 0.309 33915.0 34335.2560.25 0.160312 24.047 7.7825 45479.8 0.309 14053.3 14613.5726.30 0.059767 8.965 2.9014 16955.5 0.309 5239.2 5965.5984.71 0.032239 4.836 1.5650 9145.9 0.309 2826.1 3810.8
1319.74 0.018504 2.776 0.8983 5249.6 0.309 1622.1 2941.91677.71 0.009666 1.450 0.4692 2742.2 0.309 847.4 2525.12529.11 0.003265 0.490 0.1585 926.2 0.309 286.2 2815.33834.23 0.001098 0.165 0.0533 311.5 0.309 96.2 3930.56719.18 0.000356 0.053 0.0173 101.1 0.309 31.2 6750.48361.90 0.000199 0.030 0.0097 56.5 0.309 17.5 8379.4
10441.57 0.000111 0.017 0.0054 31.6 0.309 9.8 10451.315950.25 0.000038 0.006 0.0018 10.7 0.309 3.3 15953.5
Costo de amortización
($)
J (m/m)
∆H (m)
N (kW)
E
(kW hs)
Costo de energía
($/kW x hs)
Costo de energía
consumida total
($)
Costo total
($)
50 100 150 200 250 300 350 400 450 5000
2000
4000
6000
8000
10000
12000
14000
16000
18000
Costo Anualizado
Costo Energía
Costo Total
ø (mm)
($)
Cálculo de la bomba subterraneaLa bomba debe impulsar el agua desde el acuifero al nivel de la superficie
Datos:Nivel de dinamico del acuifero ND = 8.72 mNivel estatico del acuifero NE = 3.33 mEspesor del acuifero m = 10 m
Profundidad de la bombaHg = NE + m
Hg = 16.33 mLe sumo 3 m por encima de la boca del pozo
Pérdidas de Carga en la Impulsion:Debidas a la friccion
0.02302Diametro (D) = 160 mm
Diametro interno (Di) = 150.6 mm
Viscocidad Cinematica = 1.00E-06Rugosidad Absoluta = 7.00E-06 m
Numero de Reynolds194647
Factor de Friccion
0.016
Velocidad 1.29
Perdida de Carga Unitaria
0.0091
Perdida de Carga Total
1.3641 m
Caudal (Qb) = m3/seg=
m2/seg
m/seg
Re=v×Dυ
=
f=−[ 1
2×log [ 2 ,51Re×√ f
+ k3 ,71×D ] ]
2
=
V=4×Q
π×D2=
j= fD
× v2
2×g=
H f= j×L=
L= 150
DEBIDO A SINGULARIDADES:Longitud equivalente de los accesorios (Le = K*D)
Valvula Exclusa:K= 8 Le = 1.28 m
Curva a 90K= 45 Le = 7.20 m
Valvula de retencion:K = 100 Le = 16 m
Curva a 45º (4 piezas) 4K= 20 Le = 12.80 m 37.28
Perdida de Carga Total 0.34 m
PERDIDA DE CARGA TOTAL EN LA IMPULSION:
1.70 m
CALCULO DE LA ALTURA MANOMETRICA:Alturas geometrica de impulsion: 16.33 m Perdida de carga en impulsion: 1.70 m
18.03 m
CALCULO DE LA POTENCIA DE LA BOMBA
7.91 H.P.
Calculo de la curva del sistemaLas perdidas de carga por friccion se calcularan con la ecuacion de Manning
Datos ImpulsionLongitud L = 150.00 mn de Manning n = 0.009Diametro D = 0.16 m
Htimp =
Hgimp =Htimp =
H l= j×Leq=
Hm=H gimp+H timp=
Nb=γ×Qb×Hm
η×76=
j =n2× V 2
R4
3
≡ n2×Q2
( π×d2
4 )2
×( d4 )4
3
=
Diametro interno Di = 0.1506 m
AccesoriosValvula de retencion:K= 100 1 Le = 16.00 m
Curva a 90 1K= 45 Le = 7.20 m
Valvula Exclusa: 1K= 8 Le = 1.28 m
Curva a 45º (4 piezas) 4K= 20 Le = 12.80 m
Le tot = 37.28 m
La ecuacion de la curva del sistema debe ser:
Donde:
Altura geometrica total = 16.33 m
Perdida de carga total en funcion del Caudal
Impulsion
0 0.000000 0.0000 0.0000 16.3300 00.001 0.000015 0.0022 0.0005 16.3327 3.60.002 0.000059 0.0088 0.0022 16.3410 7.20.003 0.000132 0.0198 0.0049 16.3547 10.80.004 0.000234 0.0352 0.0087 16.3739 14.40.005 0.000366 0.0549 0.0137 16.3986 180.006 0.000527 0.0791 0.0197 16.4288 21.60.007 0.000718 0.1077 0.0268 16.4644 25.20.008 0.000937 0.1406 0.0349 16.5056 28.80.009 0.001186 0.1780 0.0442 16.5522 32.40.01 0.001465 0.2197 0.0546 16.6043 36
0.011 0.001772 0.2658 0.0661 16.6619 39.60.012 0.002109 0.3164 0.0786 16.7250 43.20.013 0.002475 0.3713 0.0923 16.7936 46.80.014 0.002871 0.4306 0.1070 16.8676 50.40.015 0.003296 0.4943 0.1229 16.9472 54
Datos para eleccion de bomba
16.33 mPotencia = 7.91 HP
82.88
H = Hg + DHT(f(Q2))
Hg =
DHT(f(Q2))=
Q[m3/seg] Ht[m] Q[m3/h]jimp[m] Hfimp[m] Hlimp[m]
Hm =
Qb = m3/hora
De acuerdo a esto, se selecciona una bomba sumergible:MOTORARG BMS 645/5,5
Curva del equipo de bombeoEquipo de bombeo
h
42 15 5.5 0.418738 20 5.5 0.505133 25 5.5 0.548228 30 5.5 0.558221 35 5.5 0.48849 40 5.5 0.2392
Punto de funcionamiento del sistema
Caudal 39Altura manometrica 19 mrendimiento 0.49Potencia 5.5 HP
Q[m3/h]Hm[m] Nabs [H.P.]
m3/h
0.012 21322.52286 0.0165616690.016561669 25049.55499 0.0160396290.016039629 24651.60058 0.0160900230.016090023 24690.29633 0.0160850730.016085073 24686.49798 0.0160855590.016085559 24686.87048 0.0160855110.016085511 24686.83395 0.0160855160.016085516 24686.83753 0.0160855150.016085515 24686.83718 0.0160855150.016085515 24686.83721 0.016085515
fadopt fcalcRe×√f
0.34
0 10 20 30 40 500
10
20
30
40
50
60
70
0.00
0.10
0.20
0.30
0.40
0.50
0.60Bomba Sumergible
H-Q Bomba H-Q Sistema Rendimiento
Q[m3/h]
H[m
] Ren
dim
ient
o h
DISEÑO DE LA PERFORACION
Caudal a bombear Qb = 82.88297 0.02302305
Velocidad del filtro 0.03 m/seg (según tabla)Area necesaria del filtro
0.767
Tipo de acuifero: ArtesianoEspesor del acuifero m = 10 mLongitud del filtro 8 m
Superficie filtrante por metro de filtro 0.096
Caudal a bombear por metro del filtro 10.3604
Luego, de Tabla de caños de filtros (INTECO) se obtiene el siguiente filtro :Características del filtro seleccionado :
Diametro : 4 '' 101.6Diametro interior : 101.6 mmDiametro exterior : 113.6 mm 12Ranura : 2.00 mm
Superficie : 0.219
Caudal : 23.7
m3/h
Vadm =
m2
m2
m3/h.m
m2/m
m3/h.m
Lf=0,8×m=
A=Qb
V adm
=
A fm=ALf
=
Q fm=Qb
Lf
=