EVALUACIÓN ESTRUCTURAL ESTACIÓN PADRE AMAYA TORRE CADRADA DE SECCIÓN VARIABLE ALTURA 141m

Transcript of rtvc-assets-sistemasenalcolombia.gov.co.s3.amazonaws.comrtvc-assets-sistemasenalcolombia.gov.co.s3.amazonaws.com/images/stories/contrat...FOR-DIS-28...

  •  

     

                                 

     

    EVALUACIÓN ESTRUCTURAL

    ESTACIÓN PADRE AMAYA

    TORRE CADRADA DE SECCIÓN VARIABLE

    ALTURA 141m

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    LEVANTAMIENTO ESTRUCTUAL – TORRE RTVC

    CERRO PADRE AMAYA Con el fin de hacer la identificación de los elementos que componen la torre auto soportada de sección tronco piramidal de la estación Padre Amaya de RTVC, ubicada en el Cerro Padre Amaya al noroccidente de Medellín, en jurisdicción de los corregimientos de Palmitas, San Cristóbal y San Antonio de Prado, se llevó a cabo un levantamiento estructural para hacer una inspección visual y determinar su estado actual, realizando un chequeo detallado desde el punto de vista del estado de los elementos estructurales y redundantes, y la necesidad de mantenimiento, teniendo en cuenta los siguientes parámetros:

    • Identificación de elementos flexionados • Identificación de elementos flojos • Identificación de elementos faltantes • Identificación de tornillos y tuercas faltantes y/o flojos (prueba de torque) • Identificación de accesorios (antenas, escalerillas, pasarelas y plataformas) • Estado de la pintura y/o galvanizado • Estado de oxidación de elementos • Ubicación de luces de obstrucción y pararrayos. • Identificación de cableado existente. • Identificación de elementos de protección de caída. • Elaboración del perfil de la torre. • Verificación de verticalidad y torsión horizontal.

    A continuación se presenta un resumen de cada uno de los ítems contemplados en el levantamiento.

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Iden

    tifica

    ción

    de el

    emen

    tos f

    lexio

    nado

    s, ele

    men

    tos f

    lojo

    s y/o

    falta

    ntes

    En el levantamiento realizado se hizo la revisión desde los elementos de la sección inferior hasta la parte superior donde no se evidenció la presencia de elementos flexionados, ni elementos faltantes. En términos generales, los elementos estructurales y redundantes se encuentran en buen estado.

    Foto 1. Vista en contra picada de la torre Foto 2. Vista interna de la torre

    Foto 3. Vista interior de la torre. Foto 4. Detalle de cierre y plataforma

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Iden

    tifica

    ción

    de to

    rnillo

    s y tu

    erca

    s falt

    ante

    s y/o

    floj

    os

    Se revisaron la totalidad de los tornillos, nudos y uniones para verificar el diámetro, longitud, calidad, faltantes, torque y apriete de los tornillos existentes, verificando si tienen arandelas y wasas de presión. No hay tornillos faltantes y se encuentran colocados ordenadamente, con las longitudes requeridas e instalados con arandela, wasa de presión y en general presentan buenas condiciones de torque. La calidad de los tornillos es A-394 Tipo 0.

    Foto 5. Detalle de tornillos, se muestra que cumple con

    la longitud requerida Foto 6. Detalle de unión atornillada entre dos

    montantes

    Foto 7. Unión de Montantes en tramos rectos

    Foto 8. Detalle de la unión de montantes en la transición de sección.

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Iden

    tifica

    ción

    de ac

    ceso

    rios (

    ante

    nas,

    esca

    lerilla

    s, pa

    sare

    las y

    plat

    afor

    mas

    ) En el levantamiento se identificaron las antenas existentes en la torre con sus dimensiones y posicionamiento, y esta información se muestra en la evaluación estructural del estado actual en un cuadro de antenas. También se identificaron las escalerillas tanto de acceso como la porta cables, las cuales una está al lado de la otra. La estructura no tiene un sistema de protección de caídas. El la escalerilla porta cables se encuentra en un 90% de su capacidad, apantallado por la escalera de acceso a la estructura, el puente guía horizontal se encuentra en buen estado. La torre cuenta con 12 plataformas de descanso correctamente instaladas, las cuales cuentan con guarda cuerpo, guarda pies y pasamanos, y piso en lámina perforada. La torre cuenta con 12 plataformas de descanso tipo rejilla, con una plataforma principal tipo pasarela, que abarca el cuadrante de la torre ubicada a nivel 31 mts.

    Foto 9. Puente guía de onda Foto 10. Escalera porta cables y escalera de acceso sin línea de vida

    Foto 11. Escalera de acceso sin línea de vida Foto 12. Escalera de acceso sin línea de vida y detalle de plataforma de descanso

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Foto 13. Detalle pasarela a la altura de 31.00m, cuenta con pasamanos, guarda cuerpo y guarda pie Foto 14. Detalle de plataforma de descanso tipo rejilla

    Foto 15. Vista general de antenas Foto 16. Antenas UHF existentes

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Iden

    tifica

    ción

    de si

    stem

    as d

    e luc

    es y

    par

    a ray

    os

    En el levantamiento se revisaron los sistemas de luces de obstrucción, faros, caperuzas, caja de control, foto celda, acometida y cableado, El sistema de luces se encuentra en tres partes de la torre: a 45m, 93m y 150m. Los cuales se encontraron en buen estado y correcto funcionamiento. El sistema de para rayos se reviso soporte, cableado, aisladores y soldaduras. Encontrando 2 para rayos en la estructura a 74m y 140m. Se observo que el cableado, no esta aterrizado correctamente ya está pegado con amarres a la estructura y no posee aisladores.

    Foto 17. Detalle luces obstruccion. Foto 18. Detalle de luz a 93m.

    Foto 19. Detalle Para Rayo centro de la torre Foto 20. Detalle cableado pegado a torre sin aisladores.

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Esta

    do d

    e la p

    intu

    ra y/

    o ga

    lvani

    zado

    y es

    tado

    de o

    xidac

    ión

    de el

    emen

    tos

    La pintura en la estructura presenta una muy buena apariencia con alta adherencia y no se evidencian soplos, agrietamientos ni desprendimientos. La Pintura en la estructura cumple con el reglamento de la Aeronáutica Civil (Aerocivil) en su capítulo decimo cuarto Parágrafo 14.3.6.2.4. Referente a la cantidad de flanjas como debe estar pintada la estructura la cual solo debe tener siete flanjas de dos colores (blanco y naranja) empezando y terminando con naranja. El galvanizado en un 99% está en buen estado, presentándose algunos focos de corrosión en elementos no estructurales tal como el material de los soportes de antenas nivel 65m, pero que no afectan la integridad de la torre.

    Foto 13. Prueba de Adherencia pintura de la torre Foto 14. Detalle de las franjas iniciales.

    Foto 21. Detalle de corrosión en soportes, antenas Foto 22. Soportes antenas con oxidación Nivel 65m.

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Iden

    tifica

    ción

    de el

    emen

    tos d

    e pro

    tecc

    ión

    de ca

    ída

    La estructura no cuenta con medidas activas de protección tal como lo señala la resolución numero 003673 de 2008 en su capítulo IV articulo 12 parágrafo del ministerio de protección social, referente de líneas de vida verticales fijas, con la cual debería de contar una estructura de este tipo, reglamentado en la guía de trabajo seguro en torres de telecomunicaciones expedido por el ministerio de protección social. La escalera es tipo gato, cuenta con guarda cuerpo y un ancho de 500 mm hasta los 130 mts. Apartir de esta altura la escalera se reduce a un ancho de 200 mm, y por la gran cantidad de cableado de las antenas tipo panel el acceso se limita y debe ser realizado por la parte externa de la estructura

    Foto 23. Escalera sin hay línea de vida. Foto 24. Vista de escalera, reducida a partir de 130 mt.

    Foto 25. Acceso reducido por cableado de antenas al interior escalera 200 mm.

    Foto 26. Plataforma de descanso, en nivel 31 mts. Plataformas en buen estado.

  • FOR-DIS-28 Version: 01

    INSTATEL COLOMBIA CI LTDA

    DESCRIPCIÓN DEL PROYECTO

    ITEM DESCRIPCIÓN

    Silu

    eta t

    orre

    exist

    ente

    N+141

    Sección transversal: 1.38m

    Sección transversal: 0.70m

    Sección transversal: 0.70m

    N+132

    N+128

    Sección transversal: 1.38m N+118

    Sección transversal: 2.65m N+115

    Sección transversal: 2.65m N+93.54

    Apertura de patas: 15.20m N+0.00

    DESCRIPCIÓN DE LA SILUETA

    Estructura Tronco piramidal decuatro lados, de sección variable.

    Arranca con una apertura de patasde 15.20m y va reduciento su

    sección con una pendienteconstante hasta la altura de

    93.54m, donde la seccióntransversal es de 2.65m. Apartir de

    esta altura continúa con secciónconstante de 2.65m hasta laaltura de 115 sitio en el cual

    comienza una transición troncopiramidal hasta la altura de118.80m, donde la seccion

    transversal es de 1.38m; continúacon sección constante hasta los

    128m, nivel en el cual encontramosotra transición tronco piramidal

    hasta la altura de 132m donde lasección transversal es de 0.70m.

    Apartir de este nivel, continúa consección constante hasta la partesuperior de la torre a la altura de

    141m

    CALIDAD DE LOS MATERIALES

    Perfilería estructural en acero dealta resistencia ASTM A-572

    Platinería en acero de resistencianormal ASTM A-36

    Tornillería de resistencia normal enacero SAE Grado 2

  • Versión: 02

    Edición: 1.0Fecha: 27/03/2010

    Altura de la torre: 141 m Desplazamiento admisible: 0.0025HH = Altura de la torre m

    grad. min. seg. grad. min. seg.0 0 0 0 0 0 Ok

    359 59 42 0 0 18 Ok359 58 26 0 1 34 Ok359 57 11 0 2 49 Ok359 55 55 0 4 5 Ok359 54 40 0 5 20 Ok359 55 55 0 4 5 Ok

    Distancia de la estación a la torre: 173.250 m

    grad. min. seg. grad. min. seg.0 0 0 0 0 0 Ok

    359 59 49 0 0 11 Ok359 58 34 0 1 26 Ok359 57 18 0 2 42 Ok359 56 2 0 3 58 Ok359 54 47 0 5 13 Ok359 56 53 0 3 7 Ok

    Distancia de la estación a la torre: 104.700 m

    Elaboró: Revisó:

    INSTATEL COLOMBIA CI LTDA.VERTICALIDAD DE TORRES

    La torre está ubicada en La Base Militar Cerro Padre Amaya, al noroccidente de Medellín, en jurisdicción de los corregimientos de Palmitas, San Cristóbal y San Antonio de Prado; el acceso al sitio se hace por carreteable hasta la estación. La torre está conformada por cuatrocuerpos de diferente sección transversal, de los cuales el primero es de sección tronco piramidal desde el nivel +0.00m hasta el nivel +93.54m; apartir de éste nivel y hasta +115m, la sección es cuadrada de 2.65m de lado. Desde el nivel +118m hasta el nivel +128 la sección también es cuadrada de 1.38m de ancho. Desde el nivel +132 hasta el nivel +141, la sección es cuadrada de 0.70m de lado.

    RTVCAntioquiaMedellínBase Militar Cerro Padre Amaya Estación total Topcon GTS 226

    113.50 0.159141.00 0.095

    0.2690.206

    Angulo Horizontal Desviación Desplazamiento Desp. Admis.

    0.0790.126

    VERIFICACIÓN DE VERTICALIDAD CARA B

    0.000

    0.284

    0.234

    0.353

    0.034

    0.234

    0.1810.1210.082

    0.0340.079

    0.353

    Verificaciónm13.4031.4050.50

    0.284

    0.0050.044 0.126

    Altura

    Equipo utilizado:

    TOMA DE DATOS

    Desp. Admis.

    0.0000.015

    m

    FOR-DIS-30

    VERIFICACIÓN DE VERTICALIDAD

    EST-015-EVALUACIÓN TORRE PADRE AMAYA

    Angulo Horizontal Desviación Verificaciónm

    VERIFICACIÓN DE VERTICALIDAD CARA CDesplazamiento

    ESQUEMA DEL LEVANTAMIENTO

    DESCRIPCIÓN DEL SITIO

    Descripción general:

    m

    0.0790.142

    72.35

    Propietario:Departamento:Municipio:Dirección:

    Alturam

    13.40

    0.206

    93.55

    31.4050.5072.3593.55

    113.50141.00

    m

    0.181

    Ing. PATROCINIO PARRA GALINDOMP. 15202 146419 BYC

    Cara B

    Cara D

    Cara C

    Cara A

    Mont. BMont.

    C

    Mont.

    AMont. D

    Estación 1

    Estación 2

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    EVALUACIÓN ESTRUCTURAL

    ESTACIÓN CERRO PADRE AMAYA

    TORRE CADRADA DE SECCIÓN VARIABLE

    ALTURA 141m

    Diseñó:

    ING. HELMAN ORLANDO MOZO MOZO Ing Civil

    MP. 15202132829 BYC

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    EVALUACIÓN ESTRUCTUAL TORRE METÁLICA AUTOSOPORTADA ALTURA 150 m INTRODUCCIÓN En el éste documento se describe la memoria de la evaluación estructural de la torre auto soportada cuadrada de sección variable con una altura de 141 m ubicada en la estación Padre Amaya RTVC, ubicada en el Cerro Padre Amaya al noroccidente de Medellín, en jurisdicción de los corregimientos de Palmitas, San Cristóbal y San Antonio de Prado,. Para el análisis matemático se utilizó velocidad de viento de diseño de 120 Km/h. y velocidad de operación de 60 Km/h En una primera parte se incluye la descripción de la estructura estudiada, luego los criterios básicos para el análisis y el diseño, evaluación de cargas, y por último el listado de datos de entrada y de salida del programa Tower de la casa Power Line System Inc.. La evaluación estructural fue realiza de acuerdo con los datos de campo levantados en la estación base estación Padre Amaya RTVC, localizada al noroccidente de Medellín; cualquier cambio genera un estudio diferente. La torre en estudio tiene instaladas antenas para la transmisión de señal de televisión. DESCRIPCIÓN DE LA ESTRUCTURA EXISTENTE La torre actual está conformada por una eestructura tronco piramidal de cuatro lados, de sección variable. Arranca con una apertura de patas de 15.20m y va reduciendo su sección con una pendiente constante hasta la altura de 93.54m, donde la sección transversal es de 2.65m. A partir de esta altura continúa con sección constante de 2.65m hasta la altura de 115 sitio en el cual comienza una transición tronco piramidal hasta la altura de 118.80m, donde la sección transversal es de 1.38m; continúa con sección constante hasta los 128m, nivel en el cual encontramos otra transición tronco piramidal hasta la altura de 132m donde la sección transversal es de 0.70m. A partir de este nivel, continúa con sección constante hasta la parte superior de la torre a la altura de 141m. (Ver figura 1) Para el mantenimiento, la estructura cuenta con una escalera de acceso y una escalera porta cable vertical.

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    Figura 1. Esquema de la silueta de la torre existente

    N+141

    Sección transversal: 1.38m

    Sección transversal: 0.70m

    Sección transversal: 0.70m

    N+132

    N+128

    Sección transversal: 1.38m N+118

    Sección transversal: 2.65m N+115

    Sección transversal: 2.65m N+93.54

    Apertura de patas: 15.20m N+0.00

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    CONDICIONES DE CARGA CARGAS ACTUALES DE LA TORRE En la actualidad, la torre cuenta con las siguientes cargas: UBICACIÓN CANT. TIPO DE ANTENA DIMENSIONES NIVEL

    MONTANTE B 1 ANTENA PARABOLICA D= 2.44 m +6.20m

    MONTANTE C 1 ANTENA PARABOLICA D= 1.20m +12.26m

    MONTANTE B 1 ANTENA PARABOLICA D= 1.20m +14.70m

    MONTANTE C 1 ANTENA PARABÓLICA D= 2.44 m +16.22m

    MONTANTE B 1 ANTENA PARABOLICA D= 1.80 m +18.77m

    MONTANTE C 1 ANTENA PARABOLICA D= 2.44 m + 20.44m

    MONTANTE B 1 ANTENA PARABOLICA D= 1.80 m +22.68m

    MONTANTE C 1 ANTENA RADOME D= 3.00 m +24.28m

    MONTANTE B 1 ANTENA RADOME D= 2.44 m +31.73m

    MONTANTE A 1 ANTENA YAGI L= 3.00 m +31.73m

    MONTANTE A 1 ANTENA YAGI L= 3.00 m +47.00m

    MONTANCE C 1 ANTENA TIPO ONNI RF TECHNOLOGY D=1m ALTURA 1.20 m +37.63m

    CARA C 3 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.74m X 2.50m Entre + 57m y 65m

    CARA D 3 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.74m X 2.50m Entre + 57m y 65m

    CARA C 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.74m X 2.50m Entre + 60m y 65m

    CARA B 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.74m X 2.50m Entre + 60m y 65m

    CARA A 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.74m X 2.50m Entre + 60m y 65m

    MONTANTE A 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.25m X 1.55m Entre + 84m y 87m

    MONTANTE B 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.25m X 1.55m Entre + 84m y 87m

    MONTANTE C 2 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.25m X 1.55m Entre + 84m y 87m

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    CARA A 6 ANTENA THOMSON 1.21m X 2.13m Entre +101m Y 109m

    CARA B 6 ANTENA THOMSON 1.21m X 2.13m Entre +101m Y 109m

    CARA C 6 ANTENA THOMSON 1.21m X 2.13m Entre +101m Y 109m

    CARA D 6 ANTENA THOMSON 1.21m X 2.13m Entre +101m Y 109m

    CARA A 6 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.45m X 1.45m Entre +118m Y 128m

    CARA B 6 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.45m X 1.45m Entre +118m Y 128m

    CARA C 6 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.45m X 1.45m Entre +118m Y 128m

    CARA D 6 ANTENA PANEL VHF BANDA III. 2 DIPOLOS 1.45m X 1.45m Entre +118m Y 128m

    CARA A 8 ANTENA PANEL UHF BANDA ANCHA DIRECCIONAL 1.05m X 0.45m Entre +132m Y 141m

    CARA B 8 ANTENA PANEL UHF BANDA ANCHA DIRECCIONAL 1.05m X 0.45m Entre +132m Y 141m

    CARA C 8 ANTENA PANEL UHF BANDA ANCHA DIRECCIONAL 1.05m X 0.45m Entre +132m Y 141m

    CARA D 8 ANTENA PANEL UHF BANDA ANCHA DIRECCIONAL 1.05m X 0.45m Entre +132m Y 141m

    En esta torre se propone el desmontaje del sistema de antenas radiantes existentes (UHF configuración 6-6-6-6) para luego montar un nuevo sistema de antenas radiantes UHF configuración 6-6-6-6. Es decir se colocaran la misma referencia de antenas (nuevas) pero con una guía de onda más gruesa HIPOTESIS 1 Realizar un estudio estructural con la totalidad de antenas actualmente instaladas e indicar cuales serian las cargas máximas remanentes (cuál es la posibilidad de adicionar antenas y de qué tipo)

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    ESPECIFICACIONES TECNICAS MATERIALES Para la evaluación de la torre se tuvieron en cuenta los siguientes materiales: Perfiles Acero ASTM A-36 A-572 GR50 Platinas Acero ASTM A-36 A-572 GR50 Tornillos ASTM A 394 T-0 NORMAS AISC 2010 ASCE, report 52 EIA/TIA Standard, EIA/TIA-222-G ANSI/ASCE 10-90 (1991) ACI 318 – 08 NSR-98 (1998) CARGAS SOBRE LA TORRE CARGAS DE VIENTO Las cargas de viento sobre la estructura fueron evaluadas y aplicadas como fuerzas horizontales concentradas en los nudos superiores e inferiores de cada una de las secciones en que se halla dividida la estructura, las cuales fueron determinadas por el diseñador. El cálculo de las cargas de viento lo realiza el software Tower V10.2 siguiendo la metodología establecida por la Norma TIA/EIA-222-G (Structural Standard for Steel Antenna Towwers and Antenna Supporting Structures1), para lo cual, el diseñador alimenta el programa con los datos de velocidad de viento de diseño, velocidad de viento de operación, tipo de estructura, categoría de la topografía y categoría de exposición. CARGAS DE VIENTO SEBRE ANTENAS Para el cálculo de las cargas de viento sobre antenas y accesorios, es necesario alimentar el programa con la información del tipo y dimensiones de la antena o accesorio y la altura a la que van a estar ubicados para que éste realice los cálculos y aplique las cargas de acuerdo al procedimiento de la norma2. Para el caso de estudio, se utilizó una velocidad de viento de de diseño de 120km/h y una velocidad de operación de 60 km/h.

                                                                1 Telecomunications Industry Association, TIA/EIA-222-F (revisión de la EIA/TIA- 222-G), Arlington 2 Power Line System Inc, Tower v.10.2, Madison USA, 2010

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    Los coeficientes de forma varían con el ángulo de incidencia del viento sobre la antena y se evalúan con base en los valores máximos indicados en los manuales Parabolic Antennas Andrew y Allen Telecom Group3. Para propósitos de estas memorias, se supuso que la antena está siempre orientada de tal forma que produce la mayor carga y mayor torsión sobre la estructura. A partir de ensayos en túnel de viento realizados a sus antenas, la firma Andrew propone descomponer las acciones del viento en dos fuerzas y un momento como se muestra en la figura 4. 4 La fuerza Fa que actúa según el eje de la antena La fuerza Fs que actúa perpendicular a ese eje Un momento que se supone aplicado en un plano horizontal y actuando en un vértice.

    Figura 2. Acción del viento sobre antenas parabólicas y tipo panel Banda UHF

    En todos los casos, el área expuesta es el área proyectada sobre un plano normal al eje de la antena, independientemente del ángulo de incidencia del viento La presión del viento se calculará de acuerdo con los artículos 2.3.2 y 2.3.3 del EIA Standard, es decir: Presión qz = 0.00256*kz*V2 [1b/ft2]; [V en MPH] qz = 0.00483*kz*V2 [kg/m2]; [V en KPH] qz = 69.552*kz [kg/cm2]                                                             3 Andrew Antenna Company, Wind Forces and Loads Produced by Parabolic Antennas, Bulletin 1015D, London, 1988. 4 Valencia Clement Gabriel, Acciones del Viento Sobre las Estructuras, Bogotá, 2002

    a

    Viento

    F (s)

    F (a)

    Eje antena

    Tubo de anclaje antena

    yM

    Vista superior

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    Donde: kz = Coeficiente de exposición Kz = [z/10](2/7) z en m kz < 2.58 < 2.58 Las fuerzas del viento sobre la torre se calcularan según articulo 2.3.2 con la siguiente ecuación: Fuerza del viento F = qz*Gh*Cf*Ae (Kg) Donde: Cf = Coeficiente de forma, según EIA Standard Cf = 4.0*e2 – 5.9*e + 4.0 art. 2.3.5 Relación de solidez e = An/At At = Area perimetral total (m2) An = Área neta expuesta (m2) Gh = Factor de respuesta de ráfaga Gh = 0.65 +0.60/(h/10)1/7 art. 2.3.4 1.0 < Gh < 1.25 h = Altura total de la estructura (m) Para la incidencia oblicua del viento, según ANSI5, el área neta oblicua será: Anob = Cob*An Donde: Cob = 0.75 para incidencia a 60 grados Cob = 1.00 para incidencia normal CARGAS DE VIENTO SEGUN NORMA NSR-98: Velocidad del viento (B.6.5) Velocidad del viento básico V = 120 Km/h Velocidad de diseño ( B.6.4-2) Vs = V * S1*S2*S3 Donde:                                                             5 American National Standard Institute 

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    S1= Coeficiente de topografía S1 = 1.00 S2= Coeficiente de rugosidad del terreno (3) S2 = 0.99 S3= Coeficiente de grado de seguridad S3 = 1.05 Presión Dinámica q = 0.000048 * vs2 * S4 [KN/m^2] Donde: S4= Coeficiente de densidad del aire S4 = 0.94 Presión ejercida sobre cualquier punto de la estructura P = Cf * q Donde: Cf = Coeficiente de fuerza (Tabla B.6.8-7 NSR-98) Coeficiente de solides de 0.25 Cf= 2.50 Ae= Área Frontal efectiva q = Presión dinámica = 0.4875 KN/m2 La fuerza total del viento sobre la estructura se calculara como: F = Cf x q x Ae Debido a que las fuerzas de viento calculadas con la metodología establecida por la Norma TIA/EIA-222-G son superiores a las calculadas mediante las ecuaciones de la Norma NSR-98, para el caso de estudio se va a seguir la metodología de la norma TIA/EIA-222-G El área neta expuesta a la acción del viento incluye la correspondiente a los elementos estructurales, elementos redundantes, platinas, cartelas y a la escalerilla de acceso o la escalerilla para guía de onda. Se asume que una escalera, apantalla la otra. PESO PROPIO DE LA ESTRUCTURA El peso propio de la estructura corresponde al peso de los elementos estructurales, los cuales son calculados directamente por el software de análisis con base en el peso unitario teórico de cada uno de los perfiles utilizados, multiplicados por su longitud. Para tener en cuenta el peso aportado por elementos no estructurales tales como tornillos, platinas, elementos redundantes eclisas y cubrejuntas de unión, galvanizado, escaleras, etc., el peso de la estructura se afecta por un factor de multiplicación del peso de 1.20.

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    CARGAS VERTICALES Las cargas verticales aplicadas al modelo matemático corresponden a la carga muerta, que está constituida por los elementos mencionados en el párrafo anterior, mas el peso aportado por las antenas, las plataformas de trabajo, las plataformas de descanso y los accesorios que sean instalados en la torre. Otra carga vertical que se tiene en cuenta es la carga viva, correspondiente a 3 operarios que estén trabajando simultáneamente en la estructura, con un peso por operario de 100 kg, que incluye herramienta y elementos de protección. ANALISIS ESTRUCTURAL El análisis y evaluación de la estructura se hará para las condiciones actuales de servicio y para las condiciones finales o proyectadas; para este último caso, se plantean análisis y calculo con modificaciones en la estructura en caso b de ser necesario. El análisis hiperestático de la estructura se realizará por medio del software especializado para el diseño de torres de telecomunicaciones Tower V 10.2, que realiza de manera no lineal el análisis de primer orden y segundo orden para tener en cuenta los efectos geométricos ocasionados por los desplazamientos de la estructura. El software utiliza para sus cálculos el método de los elementos finitos basado en la solución de ecuaciones diferenciales asociadas a la geometría de la estructura, para determinar los desplazamientos en los nudos, y las fuerzas internas para cada uno de los elementos de acuerdo con las combinaciones de carga establecidas en cada hipótesis de diseño requerida. Para cada una de las hipótesis analizadas, se presentan los listados de datos de entrada (Input) y datos de salida (Output) en el siguiente orden. DATOS DE ENTRADA

    • Listado de datos generales • Listado de la geometría de la estructura (identificación de nudos, grupos de barras, apoyos,

    materiales, secciones, tornillos). • Listado de cargas sobre los nudos de acuerdo con los sistemas de cargas.

    RESULTADOS PARA LAS HIPOTESIS CONSIDERADAS

    • Listado de fuerzas axiales sobre cada elemento de la estructura. • Listado de reacciones en los apoyos. • Listado de acciones y cargas admisibles críticas en los miembros típicos. • Listado de desplazamientos de los nudos que conforman la estructura.

    UNIDADES Las unidades consideradas en los datos de entrada y salida son:

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    • Distancias en m, mm. • Cargas en Kg • Desplazamientos en m. • Esfuerzos en Kgf • Acciones y reacciones en Kg

    DISEÑO DE LA ESTRUCTURA METALICA El diseño de la estructura metálica se realizará de acuerdo con lo estipulado por las normas ANSI/EIA/TIA aplicables a las cargas de trabajo. Si: Fu = resistencia máxima a la tensión Fy = esfuerzo de fluencia del material Perfiles ASTM A-572 GR50 Fy = 3523 Kg/cm2 Perfiles ASTM A-36 Fy = 2535 Kg/cm2 Tornillo A 325 T-1 Fu = 5415 Kg/cm2 Los esfuerzos admisibles se calcularán de la siguiente manera: Tensión: Ft = 0.50 Fu (sobre área neta)

    Ft = 0.60 Fy (sobre área bruta)

    Perfiles ASTM A-36 Ft = 2277 Kg/cm2 Perfiles ASTM A-572 GR50 Ft = 3168 Kg/cm2 Flexión: Fb = 0.60 Fy*1.333 Perfiles ASTM A-36 Fb = 2025 Kg/cm2 Perfiles ASTM A-572 GR50 Fb = 2879 Kg/cm2 Compresión: Fa, según EIA/TIA/AISC con los factores SF1 y SF2

    SF1 Factor d seguridad entre 1.66 y 1.92 SF2 Factor de seguridad igual a 23/12

    La longitud efectiva y la relación de esbeltez, se calculan, de acuerdo con lo especificado en ASCE, report 52. Cortante: Tornillo A 325 T-1 Fv = 7385 Kg/cm2 Aplastamiento: Fp = 1.20 Fu

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    Perfiles ASTM A-36 Fp = 3795 Kg/cm2 Perfiles ASTM A-572 GR50 Fp = 5280 Kg/cm2 Tornillo A 325 T-1 Fp = 8862 Kg/cm2

    COMBINACIONES DE CARGA

    Para el análisis se consideraron las siguientes hipótesis de carga:

    COMBINACION CARGA MUERTA CARGA

    MUERTA CARGA VIENTO SISMO

    VELOCODAD VIENTO (km/h) ANGULO

    COMBO 1-1 1.20 1.00 1.60 0.00 100.0 0

    COMBO 1-2 1.20 1.00 1.60 0.00 100.0 45

    COMBO 1-3 1.20 1.00 1.60 0.00 100.0 -45

    COMBO 1-4 1.20 1.00 1.60 0.00 100.0 90

    COMBO 1-5 1.20 1.00 1.60 0.00 100.0 -90

    COMBO 1-6 1.20 1.00 1.60 0.00 100.0 180

    COMBO 2-1 0.90 1.00 1.60 0.00 100.0 0

    COMBO 2-2 0.90 1.00 1.60 0.00 100.0 45

    COMBO 2-3 0.90 1.00 1.60 0.00 100.0 -45

    COMBO 2-4 0.90 1.00 1.60 0.00 100.0 90

    COMBO 2-5 0.90 1.00 1.60 0.00 100.0 -90

    COMBO 2-6 0.90 1.00 1.60 0.00 100.0 180

    COMBINACION CARGA MUERTA CARGA

    MUERTA CARGA VIENTO SISMO

    VELOCODAD VIENTO (km/h) ANGULO

    COMBO 3-1 1.20 1.00 1.00 1.00 100.0 0

    COMBO 4-1 0.90 1.00 1.00 1.00 100.0 0

    SERVICIO 1-1 1.00 1.00 1.00 0.00 96.6 0

    SERVICIO 1-2 1.00 1.00 1.00 0.00 96.6 45

    SERVICIO 1-3 1.00 1.00 1.00 0.00 96.6 -45

    SERVICIO 1-4 1.00 1.00 1.00 0.00 96.6 90

    SERVICIO 1-5 1.00 1.00 1.00 0.00 96.6 -90

    SERVICIO 1-6 1.00 1.00 1.00 0.00 96.6 180

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    VIENTO 1 1.00 1.00 1.00 0.00 100.0 0

    VIENTO 2 1.00 1.00 1.00 0.00 100.0 45

    VIENTO 3 1.00 1.00 1.00 0.00 100.0 -45

    VIENTO 4 1.00 1.00 1.00 0.00 100.0 90

    VIENTO 5 1.00 1.00 1.00 0.00 100.0 -90

    VIENTO 6 1.00 1.00 1.00 0.00 100.0 180

    En los anexos se presentan los datos de entrada utilizados para la modelación de la torre, propiedades, dimensiones, etc., las fuerzas actuantes sobre los miembros y la resistencia que presentan cada uno, la deflexión producida por las cargas a la estructura la cual debe ser menor que la relación H/200, donde H es la altura de la torre, y finalmente las cargas generadas a nivel de base las cuales serán transmitidas a la estructura de cimentación.

    ANÁLISIS DE LA ESTRUCTURA CON CARGAS EXISTENTES DEMANDA/CAPACIDAD TORRE CON CARGAS EXISTENTES.  

    De acuerdo a las cargas impuestas y a la geometría de la torre, la máxima demanda que se encontró para algunos elementos supera el 100% de su capacidad, por lo cual el comportamiento de la estructura frente a las cargas descritas anteriormente ES INADECUADO.

    Además de esto algunos elementos, principalmente diagonales y horizontales sobrepasan los límites de la relación de esbeltez (kl/r), por lo tanto es necesario reducir su luz libre o aumentar su sección.

    DESPLAZAMIENTOS CON CARGAS EXISTENTES.

    De acuerdo a los resultados del análisis se encontró que el desplazamiento máximo que se puede presentar en la torre no supera el desplazamiento máximo permitido por la norma (141/200=0.705m), por lo tanto, la torre cumple esta condición.

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    1. CONCLUSIONES

    De acuerdo a los resultados obtenidos de la evaluación de carga se puede concluir que la torre tiene un comportamiento INADECUADO frente a las cargas actuales ya que algunos de sus elementos se encuentran sobre esforzados para las condiciones de carga y requisitos establecidos en la norma TIA/EIA 222 G.

    De igual forma se puede concluir que la torre no es adecuada para soportar cargas nuevas, y se debe reforzar tanto para las condiciones de carga actuales como para las condiciones de carga futuras.

    Cualquier diferencia con las cargas analizadas aquí, invalida este análisis y debe ser comunicada para su correspondiente evaluación.

  •    

        

    www.instatelcolombia.com.co Instatel Colombia C.I Ltda. NIT 900.006.360-9

    PBX: (571) 547 0790 Bogotá - Colombia

    Figura 3. Acción del viento sobre antenas parabólicas y tipo panel Banda UHF

  •  

     

                                 

     

    EVALUACIÓN ESTRUCTURAL

    ESTADO ACTUAL

    ESTACIÓN PADRE AMAYA

    TORRE CADRADA DE SECCIÓN VARIABLE

    ALTURA 141m Diseñó:

    ING. HELMAN ORLANDO MOZO MOZO Ing Civil

    MP. 15202132829 BYC

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 1 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    ******************************************************************************* * * * TOWER - Analysis and Design - Copyright Power Line Systems, Inc. 1986-2006 * * * ******************************************************************************* KL/R value of 227.69 exceeds maximum of 200.00 for member "D7P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D8P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D9P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D10P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D15P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D16P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D17P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D18P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D23P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D24P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D27P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D33P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D34P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D35P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D36P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D38P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D41P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D42P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D43P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D46P" ?? KL/R value of 266.83 exceeds maximum of 200.00 for member "D47P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D113P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D115P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D116P" ?? KL/R value of 173.65 exceeds maximum of 150.00 for member "D136P" ?? KL/R value of 158.82 exceeds maximum of 150.00 for member "D139P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D198P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D199P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D200P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D201P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D203P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D206P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D207P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D208P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D209P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D214P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D215P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D218P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D225P" ??

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 2 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    KL/R value of 236.36 exceeds maximum of 200.00 for member "D226P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D227P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D228P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D230P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D233P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D234P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D235P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D238P" ?? KL/R value of 266.83 exceeds maximum of 200.00 for member "D239P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D254P" ?? KL/R value of 173.65 exceeds maximum of 150.00 for member "D317P" ?? KL/R value of 158.82 exceeds maximum of 150.00 for member "D320P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D379P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D380P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D381P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D382P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D384P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D387P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D388P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D389P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D390P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D395P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D396P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D399P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D406P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D407P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D408P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D409P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D411P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D414P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D415P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D416P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D419P" ?? KL/R value of 266.83 exceeds maximum of 200.00 for member "D420P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D435P" ?? KL/R value of 173.65 exceeds maximum of 150.00 for member "D498P" ?? KL/R value of 158.82 exceeds maximum of 150.00 for member "D501P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D560P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D561P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D562P" ?? KL/R value of 203.99 exceeds maximum of 200.00 for member "D563P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D565P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D568P" ?? KL/R value of 410.13 exceeds maximum of 200.00 for member "D569P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D570P" ?? KL/R value of 231.64 exceeds maximum of 200.00 for member "D571P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D576P" ?? KL/R value of 200.74 exceeds maximum of 200.00 for member "D577P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D580P" ?? KL/R value of 227.69 exceeds maximum of 200.00 for member "D587P" ?? KL/R value of 236.36 exceeds maximum of 200.00 for member "D588P" ?? KL/R value of 232.69 exceeds maximum of 200.00 for member "D589P" ??

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 3 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    KL/R value of 203.99 exceeds maximum of 200.00 for member "D590P" ?? KL/R value of 247.53 exceeds maximum of 200.00 for member "D592P" ?? KL/R value of 241.61 exceeds maximum of 200.00 for member "D595P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D596P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D597P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D600P" ?? KL/R value of 266.83 exceeds maximum of 200.00 for member "D601P" ?? KL/R value of 264.80 exceeds maximum of 200.00 for member "D616P" ?? KL/R value of 173.65 exceeds maximum of 150.00 for member "D679P" ?? KL/R value of 158.82 exceeds maximum of 150.00 for member "D682P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D750P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D751P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D752P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D753P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D754P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D755P" ?? KL/R value of 365.39 exceeds maximum of 200.00 for member "D756P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D764P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D765P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D766P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D767P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D768P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D769P" ?? KL/R value of 280.28 exceeds maximum of 200.00 for member "D770P" ??

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 4 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 5 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    Member check option: ANSI/TIA 222-G-1 Connection rupture check: Not Checked Crossing diagonal check: ANSI/TIA 222-G-1 [Alternate Unsupported RLOUT = 1] Joints Geometry: Joint Symmetry X Coord. Y Coord. Z Coord. X Disp. Y Disp. Z Disp. X Rot. Y Rot. Z Rot. Label Code (m) (m) (m) Rest. Rest. Rest. Rest. Rest. Rest. ---------------------------------------------------------------------------------------------------- D0Z93P None 0 -1.325 93.33 Fixed Fixed Fixed Free Free Free D1Z93P None 1.325 -1.325 93.33 Free Free Free Free Free Free D2Z0P None -7.6 -7.6 0 Fixed Fixed Fixed Fixed Fixed Fixed D3Z9P None -3.522 -7.022 8.59 Free Free Free Free Free Free D4Z13P None 0 -6.703 13.34 Free Free Free Free Free Free D5Z19P None -6.34 -6.34 18.73 Free Free Free Free Free Free D6Z26P None -2.533 -5.833 26.29 Free Free Free Free Free Free D7Z31P None 0 -5.494 31.32 Free Free Free Free Free Free D8Z26P None -5.833 -5.833 26.29 Free Free Free Free Free Free D9Z13P None -6.703 -6.703 13.34 Free Free Free Free Free Free D10Z31P None -5.494 -5.494 31.32 Free Free Free Free Free Free D11Z36P None -5.158 -5.158 36.32 Free Free Free Free Free Free D12Z45P None -4.603 -4.603 44.58 Free Free Free Free Free Free D13Z45P None -2.383 -4.603 44.58 Free Free Free Free Free Free D14Z50P None 0 -4.215 50.35 Free Free Free Free Free Free D15Z55P None -3.883 -3.883 55.28 Free Free Free Free Free Free D16Z68P None 3.031 -3.031 67.95 Free Free Free Free Free Free D17Z68P None -3.031 -3.031 67.95 Free Free Free Free Free Free D18Z55P None 3.883 -3.883 55.28 Free Free Free Free Free Free D19Z75P None 2.534 -2.534 75.36 Free Free Free Free Free Free D20Z75P None -2.534 -2.534 75.36 Free Free Free Free Free Free D21Z81P None 2.132 -2.132 81.33 Free Free Free Free Free Free D22Z81P None -2.132 -2.132 81.33 Free Free Free Free Free Free D23Z86P None -1.827 -1.827 85.88 Free Free Free Free Free Free D24Z86P None 1.827 -1.827 85.88 Free Free Free Free Free Free D25Z90P None 1.576 -1.576 89.59 Free Free Free Free Free Free D26Z90P None -1.576 -1.576 89.59 Free Free Free Free Free Free D27Z93P None -1.325 -1.325 93.33 Free Free Free Free Free Free D28Z50P None -4.215 -4.215 50.35 Free Free Free Free Free Free D29Z0P None 7.6 -7.6 0 Fixed Fixed Fixed Fixed Fixed Fixed D30Z9P None 3.522 -7.022 8.59 Free Free Free Free Free Free D31Z19P None 6.34 -6.34 18.73 Free Free Free Free Free Free D32Z26P None 2.533 -5.833 26.29 Free Free Free Free Free Free D33Z26P None 5.833 -5.833 26.29 Free Free Free Free Free Free D34Z13P None 6.703 -6.703 13.34 Free Free Free Free Free Free D35Z31P None 5.494 -5.494 31.32 Free Free Free Free Free Free D36Z36P None 5.158 -5.158 36.32 Free Free Free Free Free Free D37Z45P None 4.603 -4.603 44.58 Free Free Free Free Free Free D38Z45P None 2.383 -4.603 44.58 Free Free Free Free Free Free D39Z50P None 4.215 -4.215 50.35 Free Free Free Free Free Free D40Z113P None -1.325 -1.325 113.3 Free Free Free Free Free Free D41Z113P None 1.325 -1.325 113.3 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 6 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    D42Z110P None -1.325 -1.325 109.9 Free Free Free Free Free Free D43Z110P None 1.325 -1.325 109.9 Free Free Free Free Free Free D44Z107P None -1.325 -1.325 106.6 Free Free Free Free Free Free D45Z107P None 1.325 -1.325 106.6 Free Free Free Free Free Free D46Z103P None -1.325 -1.325 103.3 Free Free Free Free Free Free D47Z103P None 1.325 -1.325 103.3 Free Free Free Free Free Free D48Z100P None -1.325 -1.325 99.98 Free Free Free Free Free Free D49Z100P None 1.325 -1.325 99.98 Free Free Free Free Free Free D50Z97P None -1.325 -1.325 96.66 Free Free Free Free Free Free D51Z97P None 1.325 -1.325 96.66 Free Free Free Free Free Free D52Z95P None -1.325 -1.325 95 Free Free Free Free Free Free D53Z98P None 1.325 -1.325 98.32 Free Free Free Free Free Free D54Z102P None -1.325 -1.325 101.6 Free Free Free Free Free Free D55Z105P None 1.325 -1.325 105 Free Free Free Free Free Free D56Z108P None -1.325 -1.325 108.3 Free Free Free Free Free Free D57Z112P None 1.325 -1.325 111.6 Free Free Free Free Free Free D58Z115P None -1.325 -1.325 114.9 Free Free Free Free Free Free D59Z95P None 1.325 -1.325 95 Free Free Free Free Free Free D60Z98P None -1.325 -1.325 98.32 Free Free Free Free Free Free D61Z102P None 1.325 -1.325 101.6 Free Free Free Free Free Free D62Z105P None -1.325 -1.325 105 Free Free Free Free Free Free D63Z108P None 1.325 -1.325 108.3 Free Free Free Free Free Free D64Z112P None -1.325 -1.325 111.6 Free Free Free Free Free Free D65Z115P None 1.325 -1.325 114.9 Free Free Free Free Free Free D66Z117P None 0.9017 -0.9017 117 Free Free Free Free Free Free D67Z118P None -0.69 -0.69 118 Free Free Free Free Free Free D68Z118P None 0.69 -0.69 118 Free Free Free Free Free Free D69Z117P None -0.9017 -0.9017 117 Free Free Free Free Free Free D70Z119P None -0.69 -0.69 119.4 Free Free Free Free Free Free D71Z119P None 0.69 -0.69 119.4 Free Free Free Free Free Free D72Z121P None -0.69 -0.69 120.8 Free Free Free Free Free Free D73Z121P None 0.69 -0.69 120.8 Free Free Free Free Free Free D74Z122P None -0.69 -0.69 122.2 Free Free Free Free Free Free D75Z122P None 0.69 -0.69 122.2 Free Free Free Free Free Free D76Z124P None -0.69 -0.69 123.6 Free Free Free Free Free Free D77Z124P None 0.69 -0.69 123.6 Free Free Free Free Free Free D78Z125P None -0.69 -0.69 125.1 Free Free Free Free Free Free D79Z125P None 0.69 -0.69 125.1 Free Free Free Free Free Free D80Z126P None -0.69 -0.69 126.5 Free Free Free Free Free Free D81Z126P None 0.69 -0.69 126.5 Free Free Free Free Free Free D82Z128P None 0.69 -0.69 127.9 Free Free Free Free Free Free D83Z128P None -0.69 -0.69 127.9 Free Free Free Free Free Free D84Z131P None -0.35 -0.35 130.9 Free Free Free Free Free Free D85Z131P None 0.35 -0.35 130.9 Free Free Free Free Free Free D86Z129P None 0.5767 -0.5767 128.9 Free Free Free Free Free Free D87Z130P None -0.4633 -0.4633 129.9 Free Free Free Free Free Free D88Z130P None 0.4633 -0.4633 129.9 Free Free Free Free Free Free D89Z129P None -0.5767 -0.5767 128.9 Free Free Free Free Free Free D90Z141P None -0.35 -0.35 140.9 Free Free Free Free Free Free D91Z141P None 0.35 -0.35 140.9 Free Free Free Free Free Free D92Z131P None 0.35 -0.35 131.4 Free Free Free Free Free Free D93Z132P None -0.35 -0.35 132 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 7 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    D94Z133P None 0.35 -0.35 132.6 Free Free Free Free Free Free D95Z133P None -0.35 -0.35 133.1 Free Free Free Free Free Free D96Z134P None 0.35 -0.35 133.7 Free Free Free Free Free Free D97Z134P None -0.35 -0.35 134.2 Free Free Free Free Free Free D98Z135P None 0.35 -0.35 134.8 Free Free Free Free Free Free D99Z135P None -0.35 -0.35 135.3 Free Free Free Free Free Free D100Z136P None 0.35 -0.35 135.9 Free Free Free Free Free Free D101Z136P None -0.35 -0.35 136.4 Free Free Free Free Free Free D102Z137P None 0.35 -0.35 137 Free Free Free Free Free Free D103Z138P None -0.35 -0.35 137.5 Free Free Free Free Free Free D104Z138P None 0.35 -0.35 138.1 Free Free Free Free Free Free D105Z139P None -0.35 -0.35 138.7 Free Free Free Free Free Free D106Z139P None 0.35 -0.35 139.2 Free Free Free Free Free Free D107Z140P None -0.35 -0.35 139.8 Free Free Free Free Free Free D108Z140P None 0.35 -0.35 140.3 Free Free Free Free Free Free D109Z92P None -1.44 -1.44 91.63 Free Free Free Free Free Free D111Z88P None -1.692 -1.692 87.87 Free Free Free Free Free Free D113Z84P None -1.968 -1.968 83.78 Free Free Free Free Free Free D115Z79P None -2.316 -2.316 78.6 Free Free Free Free Free Free D117Z72P None -2.76 -2.76 71.99 Free Free Free Free Free Free D119Z62P None -3.405 -3.405 62.4 Free Free Free Free Free Free D121Z9P None 7.022 -7.022 8.59 Free Free Free Free Free Free D122Z9P None -7.022 -7.022 8.59 Free Free Free Free Free Free D123Z132P None 0.35 -0.35 132 Free Free Free Free Free Free D124Z133P None 0.35 -0.35 133.1 Free Free Free Free Free Free D125Z134P None 0.35 -0.35 134.2 Free Free Free Free Free Free D126Z135P None 0.35 -0.35 135.3 Free Free Free Free Free Free D127Z136P None 0.35 -0.35 136.4 Free Free Free Free Free Free D128Z138P None 0.35 -0.35 137.5 Free Free Free Free Free Free D129Z139P None 0.35 -0.35 138.7 Free Free Free Free Free Free D130Z140P None 0.35 -0.35 139.8 Free Free Free Free Free Free D131Z92P None 1.44 -1.44 91.63 Free Free Free Free Free Free D132Z88P None 1.692 -1.692 87.87 Free Free Free Free Free Free D133Z84P None 1.968 -1.968 83.78 Free Free Free Free Free Free D134Z79P None 2.316 -2.316 78.6 Free Free Free Free Free Free D135Z72P None 2.76 -2.76 71.99 Free Free Free Free Free Free D136Z62P None 3.405 -3.405 62.4 Free Free Free Free Free Free D137Z93P None 1.325 1.457e-011 93.33 Fixed Fixed Fixed Free Free Free D138Z93P None 1.325 1.325 93.33 Free Free Free Free Free Free D139Z9P None 7.022 -3.522 8.59 Free Free Free Free Free Free D140Z13P None 6.703 1.457e-011 13.34 Free Free Free Free Free Free D141Z26P None 5.833 -2.533 26.29 Free Free Free Free Free Free D142Z31P None 5.494 1.457e-011 31.32 Free Free Free Free Free Free D143Z45P None 4.603 -2.383 44.58 Free Free Free Free Free Free D144Z50P None 4.215 1.457e-011 50.35 Free Free Free Free Free Free D145Z68P None 3.031 3.031 67.95 Free Free Free Free Free Free D146Z55P None 3.883 3.883 55.28 Free Free Free Free Free Free D147Z75P None 2.534 2.534 75.36 Free Free Free Free Free Free D148Z81P None 2.132 2.132 81.33 Free Free Free Free Free Free D149Z86P None 1.827 1.827 85.88 Free Free Free Free Free Free D150Z90P None 1.576 1.576 89.59 Free Free Free Free Free Free D151Z9P None 7.022 3.522 8.59 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 8 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    D152Z9P None 7.022 7.022 8.59 Free Free Free Free Free Free D153Z0P None 7.6 7.6 0 Fixed Fixed Fixed Fixed Fixed Fixed D154Z19P None 6.34 6.34 18.73 Free Free Free Free Free Free D155Z26P None 5.833 2.533 26.29 Free Free Free Free Free Free D156Z26P None 5.833 5.833 26.29 Free Free Free Free Free Free D157Z13P None 6.703 6.703 13.34 Free Free Free Free Free Free D158Z31P None 5.494 5.494 31.32 Free Free Free Free Free Free D159Z36P None 5.158 5.158 36.32 Free Free Free Free Free Free D160Z45P None 4.603 4.603 44.58 Free Free Free Free Free Free D161Z45P None 4.603 2.383 44.58 Free Free Free Free Free Free D162Z50P None 4.215 4.215 50.35 Free Free Free Free Free Free D163Z113P None 1.325 1.325 113.3 Free Free Free Free Free Free D164Z110P None 1.325 1.325 109.9 Free Free Free Free Free Free D165Z107P None 1.325 1.325 106.6 Free Free Free Free Free Free D166Z103P None 1.325 1.325 103.3 Free Free Free Free Free Free D167Z100P None 1.325 1.325 99.98 Free Free Free Free Free Free D168Z97P None 1.325 1.325 96.66 Free Free Free Free Free Free D169Z98P None 1.325 1.325 98.32 Free Free Free Free Free Free D170Z105P None 1.325 1.325 105 Free Free Free Free Free Free D171Z112P None 1.325 1.325 111.6 Free Free Free Free Free Free D172Z95P None 1.325 1.325 95 Free Free Free Free Free Free D173Z102P None 1.325 1.325 101.6 Free Free Free Free Free Free D174Z108P None 1.325 1.325 108.3 Free Free Free Free Free Free D175Z115P None 1.325 1.325 114.9 Free Free Free Free Free Free D176Z117P None 0.9017 0.9017 117 Free Free Free Free Free Free D177Z118P None 0.69 0.69 118 Free Free Free Free Free Free D178Z119P None 0.69 0.69 119.4 Free Free Free Free Free Free D179Z121P None 0.69 0.69 120.8 Free Free Free Free Free Free D180Z122P None 0.69 0.69 122.2 Free Free Free Free Free Free D181Z124P None 0.69 0.69 123.6 Free Free Free Free Free Free D182Z125P None 0.69 0.69 125.1 Free Free Free Free Free Free D183Z126P None 0.69 0.69 126.5 Free Free Free Free Free Free D184Z128P None 0.69 0.69 127.9 Free Free Free Free Free Free D185Z131P None 0.35 0.35 130.9 Free Free Free Free Free Free D186Z129P None 0.5767 0.5767 128.9 Free Free Free Free Free Free D187Z130P None 0.4633 0.4633 129.9 Free Free Free Free Free Free D188Z141P None 0.35 0.35 140.9 Free Free Free Free Free Free D189Z131P None 0.35 0.35 131.4 Free Free Free Free Free Free D190Z133P None 0.35 0.35 132.6 Free Free Free Free Free Free D191Z134P None 0.35 0.35 133.7 Free Free Free Free Free Free D192Z135P None 0.35 0.35 134.8 Free Free Free Free Free Free D193Z136P None 0.35 0.35 135.9 Free Free Free Free Free Free D194Z137P None 0.35 0.35 137 Free Free Free Free Free Free D195Z138P None 0.35 0.35 138.1 Free Free Free Free Free Free D196Z139P None 0.35 0.35 139.2 Free Free Free Free Free Free D197Z140P None 0.35 0.35 140.3 Free Free Free Free Free Free D198Z132P None 0.35 0.35 132 Free Free Free Free Free Free D199Z133P None 0.35 0.35 133.1 Free Free Free Free Free Free D200Z134P None 0.35 0.35 134.2 Free Free Free Free Free Free D201Z135P None 0.35 0.35 135.3 Free Free Free Free Free Free D202Z136P None 0.35 0.35 136.4 Free Free Free Free Free Free D203Z138P None 0.35 0.35 137.5 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 9 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    D204Z139P None 0.35 0.35 138.7 Free Free Free Free Free Free D205Z140P None 0.35 0.35 139.8 Free Free Free Free Free Free D206Z92P None 1.44 1.44 91.63 Free Free Free Free Free Free D207Z88P None 1.692 1.692 87.87 Free Free Free Free Free Free D208Z84P None 1.968 1.968 83.78 Free Free Free Free Free Free D209Z79P None 2.316 2.316 78.6 Free Free Free Free Free Free D210Z72P None 2.76 2.76 71.99 Free Free Free Free Free Free D211Z62P None 3.405 3.405 62.4 Free Free Free Free Free Free D212Z93P None 1.9e-015 1.325 93.33 Fixed Fixed Fixed Free Free Free D213Z93P None -1.325 1.325 93.33 Free Free Free Free Free Free D214Z9P None 3.522 7.022 8.59 Free Free Free Free Free Free D215Z13P None 2.6e-015 6.703 13.34 Free Free Free Free Free Free D216Z26P None 2.533 5.833 26.29 Free Free Free Free Free Free D217Z31P None 2.4e-015 5.494 31.32 Free Free Free Free Free Free D218Z45P None 2.383 4.603 44.58 Free Free Free Free Free Free D219Z50P None 2.3e-015 4.215 50.35 Free Free Free Free Free Free D220Z68P None -3.031 3.031 67.95 Free Free Free Free Free Free D221Z55P None -3.883 3.883 55.28 Free Free Free Free Free Free D222Z75P None -2.534 2.534 75.36 Free Free Free Free Free Free D223Z81P None -2.132 2.132 81.33 Free Free Free Free Free Free D224Z86P None -1.827 1.827 85.88 Free Free Free Free Free Free D225Z90P None -1.576 1.576 89.59 Free Free Free Free Free Free D226Z9P None -3.522 7.022 8.59 Free Free Free Free Free Free D227Z9P None -7.022 7.022 8.59 Free Free Free Free Free Free D228Z0P None -7.6 7.6 0 Fixed Fixed Fixed Fixed Fixed Fixed D229Z19P None -6.34 6.34 18.73 Free Free Free Free Free Free D230Z26P None -2.533 5.833 26.29 Free Free Free Free Free Free D231Z26P None -5.833 5.833 26.29 Free Free Free Free Free Free D232Z13P None -6.703 6.703 13.34 Free Free Free Free Free Free D233Z31P None -5.494 5.494 31.32 Free Free Free Free Free Free D234Z36P None -5.158 5.158 36.32 Free Free Free Free Free Free D235Z45P None -4.603 4.603 44.58 Free Free Free Free Free Free D236Z45P None -2.383 4.603 44.58 Free Free Free Free Free Free D237Z50P None -4.215 4.215 50.35 Free Free Free Free Free Free D238Z113P None -1.325 1.325 113.3 Free Free Free Free Free Free D239Z110P None -1.325 1.325 109.9 Free Free Free Free Free Free D240Z107P None -1.325 1.325 106.6 Free Free Free Free Free Free D241Z103P None -1.325 1.325 103.3 Free Free Free Free Free Free D242Z100P None -1.325 1.325 99.98 Free Free Free Free Free Free D243Z97P None -1.325 1.325 96.66 Free Free Free Free Free Free D244Z98P None -1.325 1.325 98.32 Free Free Free Free Free Free D245Z105P None -1.325 1.325 105 Free Free Free Free Free Free D246Z112P None -1.325 1.325 111.6 Free Free Free Free Free Free D247Z95P None -1.325 1.325 95 Free Free Free Free Free Free D248Z102P None -1.325 1.325 101.6 Free Free Free Free Free Free D249Z108P None -1.325 1.325 108.3 Free Free Free Free Free Free D250Z115P None -1.325 1.325 114.9 Free Free Free Free Free Free D251Z117P None -0.9017 0.9017 117 Free Free Free Free Free Free D252Z118P None -0.69 0.69 118 Free Free Free Free Free Free D253Z119P None -0.69 0.69 119.4 Free Free Free Free Free Free D254Z121P None -0.69 0.69 120.8 Free Free Free Free Free Free D255Z122P None -0.69 0.69 122.2 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 10 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    D256Z124P None -0.69 0.69 123.6 Free Free Free Free Free Free D257Z125P None -0.69 0.69 125.1 Free Free Free Free Free Free D258Z126P None -0.69 0.69 126.5 Free Free Free Free Free Free D259Z128P None -0.69 0.69 127.9 Free Free Free Free Free Free D260Z131P None -0.35 0.35 130.9 Free Free Free Free Free Free D261Z129P None -0.5767 0.5767 128.9 Free Free Free Free Free Free D262Z130P None -0.4633 0.4633 129.9 Free Free Free Free Free Free D263Z141P None -0.35 0.35 140.9 Free Free Free Free Free Free D264Z131P None -0.35 0.35 131.4 Free Free Free Free Free Free D265Z133P None -0.35 0.35 132.6 Free Free Free Free Free Free D266Z134P None -0.35 0.35 133.7 Free Free Free Free Free Free D267Z135P None -0.35 0.35 134.8 Free Free Free Free Free Free D268Z136P None -0.35 0.35 135.9 Free Free Free Free Free Free D269Z137P None -0.35 0.35 137 Free Free Free Free Free Free D270Z138P None -0.35 0.35 138.1 Free Free Free Free Free Free D271Z139P None -0.35 0.35 139.2 Free Free Free Free Free Free D272Z140P None -0.35 0.35 140.3 Free Free Free Free Free Free D273Z132P None -0.35 0.35 132 Free Free Free Free Free Free D274Z133P None -0.35 0.35 133.1 Free Free Free Free Free Free D275Z134P None -0.35 0.35 134.2 Free Free Free Free Free Free D276Z135P None -0.35 0.35 135.3 Free Free Free Free Free Free D277Z136P None -0.35 0.35 136.4 Free Free Free Free Free Free D278Z138P None -0.35 0.35 137.5 Free Free Free Free Free Free D279Z139P None -0.35 0.35 138.7 Free Free Free Free Free Free D280Z140P None -0.35 0.35 139.8 Free Free Free Free Free Free D281Z92P None -1.44 1.44 91.63 Free Free Free Free Free Free D282Z88P None -1.692 1.692 87.87 Free Free Free Free Free Free D283Z84P None -1.968 1.968 83.78 Free Free Free Free Free Free D284Z79P None -2.316 2.316 78.6 Free Free Free Free Free Free D285Z72P None -2.76 2.76 71.99 Free Free Free Free Free Free D286Z62P None -3.405 3.405 62.4 Free Free Free Free Free Free D287Z93P None -1.325 1.457e-011 93.33 Fixed Fixed Fixed Free Free Free D288Z9P None -7.022 3.522 8.59 Free Free Free Free Free Free D289Z13P None -6.703 1.457e-011 13.34 Free Free Free Free Free Free D290Z26P None -5.833 2.533 26.29 Free Free Free Free Free Free D291Z31P None -5.494 1.457e-011 31.32 Free Free Free Free Free Free D292Z45P None -4.603 2.383 44.58 Free Free Free Free Free Free D293Z50P None -4.215 1.457e-011 50.35 Free Free Free Free Free Free D294Z9P None -7.022 -3.522 8.59 Free Free Free Free Free Free D295Z26P None -5.833 -2.533 26.29 Free Free Free Free Free Free D296Z45P None -4.603 -2.383 44.58 Free Free Free Free Free Free D297Z131P None -0.35 -0.35 131.4 Free Free Free Free Free Free D298Z133P None -0.35 -0.35 132.6 Free Free Free Free Free Free D299Z134P None -0.35 -0.35 133.7 Free Free Free Free Free Free D300Z135P None -0.35 -0.35 134.8 Free Free Free Free Free Free D301Z136P None -0.35 -0.35 135.9 Free Free Free Free Free Free D302Z137P None -0.35 -0.35 137 Free Free Free Free Free Free D303Z138P None -0.35 -0.35 138.1 Free Free Free Free Free Free D304Z139P None -0.35 -0.35 139.2 Free Free Free Free Free Free D305Z140P None -0.35 -0.35 140.3 Free Free Free Free Free Free

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 11 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    Steel Material Properties: Steel Modulus Yield Ultimate Member Member Member Member Member Member Material of Stress Stress All. Stress All. Stress Rupture Rupture Bearing Bearing Label Elasticity Fy Fu Hyp. 1 Hyp. 2 Hyp. 1 Hyp. 2 Hyp. 1 Hyp. 2 (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) -------------------------------------------------------------------------------------------- A572-50 1.999e+005 344.7 448.2 0 0 0 0 0 0 Angle Properties: Angle Angle Long Short Thick. Unit Gross w/t Radius of Radius of Radius of Number Wind Short Long Optimize Section Type Size Leg Leg Weight Area Ratio Gyration Gyration Gyration of Width Edge Edge Cost Modulus Rx Ry Rz Angles Dist. Dist. Factor (cm) (cm) (cm) (N/m) (cm^2) (cm) (cm) (cm) (cm) (cm) (cm) (cm^3) -------------------------------------------------------------------------------------------------------------------------------------- SAE 4X4X0.25 10.16 10.16 0.635 96.32 12.52 13.5 3.175 3.175 2.019 1 10.16 5.08 0 1.0000 0 SAE 3.5X3.5X0.25 8.89 8.89 0.635 84.64 10.9 11.5 2.769 2.769 1.763 1 8.89 4.445 0 1.0000 0 SAE 3X3X0.25 7.62 7.62 0.635 71.51 9.29 9.75 2.362 2.362 1.504 1 7.62 3.81 0 1.0000 0 SAE 2.5X2.5X0.25 6.35 6.35 0.635 59.84 7.677 7.75 1.953 1.953 1.247 1 6.35 3.175 0 1.0000 0 SAE 2.5X2.5X0.1875 6.35 6.35 0.4763 44.8 5.819 10.67 1.976 1.976 1.257 1 6.35 3.175 0 1.0000 0 SAE 2X2X0.25 5.08 5.08 0.635 46.55 6.065 5 1.547 1.547 0.9931 1 5.08 2.54 0 1.0000 0 SAE 2X2X0.1875 5.08 5.08 0.4763 35.61 4.581 8 1.567 1.567 1.001 1 5.08 2.54 0 1.0000 0 SAE 2X2X0.125 5.08 5.08 0.3175 24.08 3.097 11 1.59 1.59 1.011 1 5.08 2.54 0 1.0000 0 SAE 1.5X1.5X0.125 3.81 3.81 0.3175 17.95 2.323 8 1.181 1.181 0.7518 1 3.81 1.905 0 1.0000 0 DAE 6X6X0.375 15.24 15.24 0.9525 434.9 56.26 13.67 4.775 6.655 4.775 2 15.24 7.62 0 1.0000 0 DAE 5X5X0.5 12.7 12.7 1.27 472.8 61.29 8 3.912 5.69 3.912 2 12.7 6.35 0 1.0000 0 DAE 3X3X0.25 7.62 7.62 0.635 143 18.58 9.75 2.362 3.531 2.362 2 7.62 3.81 0 1.0000 0 Angle Groups: Group Group Angle Angle Material Element Group Optimize Allow. Add. Label Description Type Size Type Type Type Group Angle Width For Optimize (cm) ---------------------------------------------------------------------------------------------------------- M1 MONTANTE1 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M2 MONTANTE2 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M3 MONTANTE3 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M4 MONTANTE4 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M5 MONTANTE5 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M6 MONTANTE6 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M7 MONTANTE7 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M8 MONTANTE8 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M9 MONTANTE9 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M10 MONTANTE10 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M11 MONTANTE11 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M12 MONTANTE12 DAE 6X6X0.375 A572-50 Beam Leg None 0.000

  • Job

    EVALUACIÓN ESTRUCTURAL – ESTACIÓN PADRE AMAYA – MEDELLIN ESTADO ACTUAL

    Page 12 of 634

    INSTATEL COLOMBIA CI LTDA

    Carrera 124 No. 17-98

    Project TORRE CUADRADA AUTOSOPORTADA DE 140m

    Date 17:07:07 03/17/10

    Fontibón - Bogotá - Phone: (57) 5470790 Client TELEFONICA TELECOM – RTVC RADIO TELEVISIÓN NACIONAL DE COLOMBIA

    Designed by Helman O. Mozo

    M13 MONTANTE13 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M14 MONTANTE14 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M15 MONTANTE15 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M16 MONTANTE16 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M17 MONTANTE17 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M18 MONTANTE18 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M19 MONTANTE19 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M20 MONTANTE20 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M21 MONTANTE21 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M22 MONTANTE22 DAE 6X6X0.375 A572-50 Beam Leg None 0.000 M23 MONTANTE23 DAE 5X5X0.5 A572-50 Beam Leg None 0.000 M24 MONTANTE24 DAE 5X5X0.5 A572-50 Beam Leg None 0.000 M25 MONTANTE25 DAE 5X5X0.5 A572-50 Beam Leg None 0.000 M26 MONTANTE26 DAE 3X3X0.25 A572-50 Beam Leg None 0.000 M27 MONTANTE27 DAE 3X3X0.25 A572-50 Beam Leg None 0.000 M28 MONTANTE28 DAE 3X3X0.25 A572-50 Beam Leg None 0.000 D2 DIAGONAL2 SAE 4X4X0.25 A572-50 Truss Other None 0.000 D3 DIAGONAL3 SAE 3X3X0.25 A572-50 Truss Other None 0.000 D4 DIAGONAL4 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D5 DIAGONAL5 SAE 4X4X0.25 A572-50 Truss Other None 0.000 D6 DIAGONAL6 SAE 4X4X0.25 A572-50 Truss Other None 0.000 D7 DIAGONAL7 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D8 DIAGONAL8 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D9 DIAGONAL9 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D10 DIAGONAL10 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D11 DIAGONAL11 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D12 DIAGONAL12 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 D13 DIAGONAL13 SAE 2X2X0.1875 A572-50 Truss Other None 0.000 D14 DIAGONAL14 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D15 DIAGONAL15 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D16 DIAGONAL16 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D17 DIAGONAL17 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D18 DIAGONAL18 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D19 DIAGONAL19 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D20 DIAGINAL20 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D21 DIAGONAL21 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D22 DIAGONAL22 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D23 DIAGONAL23 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D24 DIAGONAL24 SAE 2.5X2.5X0.1875 A572-50 Truss Other None 0.000 D25 DIAGONAL25 SAE 2X2X0.1875 A572-50 Truss Other None 0.000 D26 DIAGONAL26 SAE 2X2X0.1875 A572-50 Truss Other None 0.000 D27 DIAGONAL27 SAE 2X2X0.1875 A572-50 Truss Other None 0.000 D28 DIAGONAL28 SAE 2X2X0.1875 A572-50 Truss Other None 0.000 H1 HORIZONTAL1 SAE 3.5X3.5X0.25 A572-50 Truss Other None 0.000 H6 HORIZONTAL6 SAE 3X3X0.25 A572-50 Truss Other None 0.000 H9 H