NVUS 1190 12/06
Accidente Cerebro Vascular
EstadisticasEstadisticas: 15% de todos los ACV son hemorragicos vs. 85% isquemicos
55% de aneurismas detectadas son tratadas, 55% de aneurismas tratadas son con coils
El average de edad en pacientes es entre 40-60 aos
La incidencia en mujeres es de, 3:2
1 de cada 15 personas tendr un aneurisma durante su vida
Unruptured Ruptured
-
8/6/2019 PRESENTACIN MIN SALUD
3/49
3
Detalle de la EnfermedadAneurismas Cerebrales
Enfermedad de la Arteria
pared abombada.
Peligro de ruptura-HemorragiaSub Aracnoidea (SAH)
Nombrada por el vaso de donde
nace
Tratamiento: excluir el flujo
sanguineo Clipping, coiling, sacrificio de
arteria
Netter Presenter Image 2007 Icon Learning Systems. All rights reserved.
-
8/6/2019 PRESENTACIN MIN SALUD
4/49
NVUS 1190 12/06
Sitios comunes para Aneurismas
Sitios mas comunes: arteria cerebral media
carotida interna
comunicante anterior
punta de la basilar
-
8/6/2019 PRESENTACIN MIN SALUD
5/49
NVUS 1190 12/06
GDC Coil Oclusin
de Aneurisma
Illustration prepared by Boston Scientific-Neurovascular. Illustration not to scale.
-
8/6/2019 PRESENTACIN MIN SALUD
6/49
6
The EquipmentSingle Plane C-Arm
Used mostly for
peripheral and
cardiac interventions.
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
7/49
7
EquipoArco en C
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
8/49
8
Monitores
Arriba:
AP
Lateral
Cada monitor
tiene losangulos de la
camara para
su facil
reubicacin
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
9/49
9
Acceso VascularCaja de vista angiografica
La mayoria de los
estudios de hoy da
son digitales.
Los mdicos usan las
cajas de vista, para
revisar estudios viejos
referidos por
hospitales pequeos
con vieja tecnologa
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
10/49
10
The EquipmentAnesthesia Equipment
This is an anesthesia
machine. Anesthesia
is used either forconscious sedation or
full anesthesia for
Interventional
procedures.
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
11/49
11
The EquipmentProduct Storage
Our products are
often stored in
cabinets with rollerlockers.
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
12/49
12
Vascular AccessSterilization
Betadine is applied
in a swirling pattern
at the groin site andsits for 3-5 minutes
before removing
excess.
Photo taken by Boston Scientific representative.
Betadine is a registered trademark of Purdue Frederick.
-
8/6/2019 PRESENTACIN MIN SALUD
13/49
13
Vascular AccessGroin Exposure
The sterile prepped
groin is exposed for
puncture.
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
14/49
14
Vascular AccessFemoral Identification
Palpate femoral pulse
to determine
puncture site.
Area is prepped for
supplies needed
during procedure.
(The red tip is the
SHEATH, which is
already attached to
the flush system).
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
15/49
15
Vascular AccessLocal Anesthetic
E
Lidocane is used as a
local anesthetic to
numb the groin area.
C2.21
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
16/49
16
Vascular AccessNeedle Puncture
E
In this picture, the left
hand is finding the
pulse and the righthand is using a 20
gauge needle (hollow)
to puncture femoral
artery for vascular
access.
C2.22
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
17/49
17
Vascular AccessNeedle Puncture
E2.22
Photo taken by Boston Scientific representative.
Arterial blood
return is the sign
of a successful
puncture.
-
8/6/2019 PRESENTACIN MIN SALUD
18/49
18
Vascular Access.035 Guidewire Placement
E
The access guidewire
placed inside of
puncture needle tosecure track inside
the vessel.
The needle is then
removed and
pressure is held until
a sheath is placed.
C2.23
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
19/49
19
Vascular AccessSheath Placement
The sheath being slid
over the guidewire.
(The white with the
red tip is the sheath,
blue is the obturator)
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
20/49
20
Vascular AccessSheath Placement
E2.24
Photo taken by Boston Scientific representative.
Obturator
Sheath
-
8/6/2019 PRESENTACIN MIN SALUD
21/49
21
Vascular AccessSheath Placement
E2.24
Photo taken by Boston Scientific representative.
Sheath is being
placed through
the skin.
-
8/6/2019 PRESENTACIN MIN SALUD
22/49
22
Vascular AccessSheath Placement
E2.24
Photo taken by Boston Scientific representative.
Sheath is in and
connected to heparin
flush system
-
8/6/2019 PRESENTACIN MIN SALUD
23/49
23
Vascular AccessContinuous Flush
E
Drip chamber beingprepped for flushsystem.
Saline bag is notsterile.
Flush tubing is sterile.
A nurse or techmonitors flush toensure it iscontinuous duringprocedure.
C2.30
Photo taken by Boston Scientific representative.
-
8/6/2019 PRESENTACIN MIN SALUD
24/49
NVUS 1190 12/06
Continuous Infusion Setup
One-way
Stopcock
Line to Flush Solution
RHV
Guidecatheter
RHV
Line to Flush Solution
Femoral
Sheath
Three-way
Stopcock
Line to Flush SolutionSyringe
Microcatheter
Illustrations prepared by Boston Scientific-Neurovascular. Illustrations not to scale.
-
8/6/2019 PRESENTACIN MIN SALUD
25/49
25
Vascular AccessFinal Set Up
E2.24
Photo taken by Boston Scientific representative.
One-wayStopcock
Line to Flush Solution
RHVGuidecatheter
RHV
Line to Flush Solution
Femoral
Sheath
Three-way
Stopcock
Line to Flush SolutionSyringe
Microcatheter
Detachable
Coil
-
8/6/2019 PRESENTACIN MIN SALUD
26/49
CATETER GUIA GUIDER XF
VARIEDAD DE CURVAS
CONSTRUCCION DE DOBLE HEBRA=
MAYOR SOPORTE
-
8/6/2019 PRESENTACIN MIN SALUD
27/49
Guide Catheter Fundamentals
Example of where a guide catheter isseated:
-
8/6/2019 PRESENTACIN MIN SALUD
28/49
MICROCATETERES
Excelsior SL-10
Menor perfil con muy buen
lumen interno
Excelente para accesos tortuosos
y distales.
Menor diametro externo
Ideal para trabajar con Stent
NeuroformMicrocateter de Menor friccin
con Coils Matrix
-
8/6/2019 PRESENTACIN MIN SALUD
29/49
MICROCATETERES
Excelsior 1018
Lumen Interno extra-grande
Compatible con todos los coils
Punta Suave
Buena capacidad de embuje
Excelente Soporte
Compatibilidad con todos los
tipos de coils: Matrix, GDC-10,and GDC-18
-
8/6/2019 PRESENTACIN MIN SALUD
30/49
MICROGUIAS TRANSEND
-
8/6/2019 PRESENTACIN MIN SALUD
31/49
TIPOS DE COILS
3D Shape 2 Diameter SoftStandard Ultra-Soft*
-
8/6/2019 PRESENTACIN MIN SALUD
32/49
NVUS 1190 12/06
Soft
UltraSoft
SR2 Diameter
Comprehensive Solutions
for Aneurysm Treatment3D Shape
Illustrations prepared by Boston Scientific-Neurovascular. Illustrations not to scale.
360
-
8/6/2019 PRESENTACIN MIN SALUD
33/49
NVUS 1190 12/06
GDC Standard Coil
GDC SoftGDC UltraSoft
GDC 10-Soft is 22% softer compared to GDC-10 Standard.*
GDC 10-UltraSoft is 50% softer compared to GDC-10 Soft*
GDC-10 UltraSoft Coils
*Bench testing on file at Boston Scientific . Bench results may not
necessarily be indicative of clinical performance.
-
8/6/2019 PRESENTACIN MIN SALUD
34/49
NVUS 1190 12/06
Why is a 2D Loop Important?
GDC Detachable Coils
-
8/6/2019 PRESENTACIN MIN SALUD
35/49
GDC 360 Coils
2D Loop = Liberacion Controlada
Forma complex = Menor Compartimentalizacion
DiferenteGrado de Suavidad = Mayor Adecuacin
Stretch Resistant = Reposicionamiento
Diseo 360
-
8/6/2019 PRESENTACIN MIN SALUD
36/49
NVUS 1190 12/06
GDC 360 Coils
Spherical
Elongated
Bi-lobed
Designed for the Treatment of All
Shapes of Intracranial Aneurysms
Images provided by Boston Scientific Neurovascular
-
8/6/2019 PRESENTACIN MIN SALUD
37/49
COIL MATRIX
-
8/6/2019 PRESENTACIN MIN SALUD
38/49
Como funciona el Matrix
1. Oclusion acelera formacion de trombos2. El copolimero se biograda
3. Bio-degradacion acelera la formacion de trombos
en tejido fibrocelular
**MatrixGLP animal study: Statistically significant results. Data on file at Boston Scientific Neurovascular.
**
-
8/6/2019 PRESENTACIN MIN SALUD
39/49
Example of Successful Matrix Coil
Case
2PT
038 rev103/03
Immediate Post
12 Month F/U3 Month F/U
Basilar ApexNon SAH
11X9mm Dome
4mm Neck
11 CoilsJackson Memorial, Miami
Results fromcasestudies arenot predictive of results ino thercases. Results inothercases mayvary.
-
8/6/2019 PRESENTACIN MIN SALUD
40/49
NVUS 1190 12/06
Marker Band Alignment
...See the light
Illustrations prepared by Boston Scientific-Neurovascular. Illustrations not to scale.
-
8/6/2019 PRESENTACIN MIN SALUD
41/49
NVUS 1190 12/06
Main Coil Pusher Wire
Detach Zone
Non-Conductive
Plug
GDC Coil Detachment Zone
Illustrations prepared by Boston Scientific-Neurovascular. Illustrations not to scale.
-
8/6/2019 PRESENTACIN MIN SALUD
42/49
NVUS 1190 12/06
Connecting Cables
Part #451102-4
Connecting Cables
& Terminals
-
8/6/2019 PRESENTACIN MIN SALUD
43/49
NVUS 1190 12/06
Detachable Coil Power Supply
Voltage Display
Current Display
Time Display
Check Circuit
Indicator
Power Button
Current Setting andResume Control
Low Battery Indicator
Detach IndicatorPower Supply
Part #451007-4
-
8/6/2019 PRESENTACIN MIN SALUD
44/49
STENT INTRACRANEAL NEUROFORM
-
8/6/2019 PRESENTACIN MIN SALUD
45/49
STENT INTRACRANEAL NEUROFORM
Aposicionatraumatica en laarteria
Mnimo acortamientopost-liberacion
(1.8% to 5.4%)*
Stent Auto expansible de NITINOL
-
8/6/2019 PRESENTACIN MIN SALUD
46/49
STENT INTRACRANEAL NEUROFORM
BUENA FLEXIBILIDAD Y FUERZA RADIAL
-
8/6/2019 PRESENTACIN MIN SALUD
47/49
Stent colocado
Marcas Radiopacas
-
8/6/2019 PRESENTACIN MIN SALUD
48/49
-
8/6/2019 PRESENTACIN MIN SALUD
49/49
Wingspan Stent y Gateway
NUEVAS TECNOLOGIAS, NUEVOS TRATAMIENTOS