Presenta Luminaria Beghelli BS100 y Balastro de … · Código Descripción Cantidad 3905 Guarda de...
Transcript of Presenta Luminaria Beghelli BS100 y Balastro de … · Código Descripción Cantidad 3905 Guarda de...
Presenta Luminaria Beghelli BS100y Balastro de Emergencia Luce TL
Beghelli BS100-LEDLuminaria hermética en LED IP66 de bajo consumo energético y vida útil estimada de 100.000 horas.
Beghelli Luce TLBalastro de emergéncia que está diseñado para proporcionar iluminación de emergéncia para �uorescente existente o nueva luminaria.
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
Beghelli BS100 EliteLuminarias a prueba de humedad y polvo IP66 - Re�ector parabólico de policarbonato (Elite) - Para lámparas T8 y T5
Material:- Cuerpo: Policarbonato inyectado, estabilizado contrarayos UV, autoextinguible- Color: Gris RAL7035- Reflector: Parabólico de policarbonato inyectado, estabilizadocontra rayos UV, autoextinguible acabado aluminizado brillante- Difusor: Policarbonato transparente resistente al impacto- Broches: Poliéster reforzado con fibra de vidrio- Empaque: Poliuretano expandido, aplicado en forma líquida
Grado de Protección: IP66
Voltaje: 127VCA, 60 Hz, opción de balastro multivoltaje
Equipo eléctrico: Balastro electrónico de AFP y bajas pérdidas ó dimeablecuando sea requerido. Se puede ofrecer balastro deemergencia, sobre pedido
Montaje: Suspendido con los accesorios adecuados ó parasobreponer en techo
Accesorios: (Se suministran con la luminaria)- Juego de gancho y grapa metálicos para montaje- Juego de conector glándula y tapón
Aplicaciones:Area de regaderasArmadorasAlmacenesGranjasEstacionamientos
BS-100 elite leaderLuminarias a prueba de humedad y polvo IP66 - Reflector parabólico de policarbonato (Elite) - Para lámparas T8 y T5
140
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
Código Descripción Cantidad
3905 Guarda de protección para luminarias de 2x14W y 2x17W
Artículo
1
8066 Guarda de protección para luminarias de 2x28W y 2x32W 1
3503 Cable de acero para suspención de 1200mm de long. 1
8173 Cable de acero para suspención de 1200mm de long. con cable de 3x18 AWG
ACCESORIOS: Deben pedirse por separado
8012 Juego de clemas para cable en luminarias de 32W 1
3504 Brazo para montaje a muro 1
Luminarias a prueba de humedad y polvo IP66 - Reflector parabólico de policarbonato (Elite) - Para lámparas T8 y T5
3619EE (2x32W)
leaderBS-100 elite
PotenciaW
Dimensiones (mm) Lámpara
2x14 670 170 475
L B I
T5
2x24 670 170 475 T5
2x28 1280 170 660 T5
2x54 1280 170 660 T5
95
95
95
95
H
2x17 670 170 475 T8
2x32 1280 170 660 T8
95
95
142
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
1
Luminarias a prueba de humedad y polvo IP66 - Reflector parabólico de policarbonato (Elite) - Para lámparas T8 y T5
W Descripción Kg
2x17 3617 BS 100 RE 218
Código
2.3
2x32 3619EE BS 100 RE 236 3.3
127V60Hz IP 66 T8
BALASTRO ELECTRÓNICO
W Descripción Kg
2x14 3717 T5 RE 214
Código
2.3
2x24 3717-224 BS 110 T5 RE 224 2.3
2x28 3718 BS 110 T5 RE 228 3.3
3722 BS 110 T5 RE 254 3.3
127V60Hz IP 66 T5
BALASTRO ELECTRÓNICO
Clip de cierre Suspensión de reflector Instalación suspendida con gancho metálico
incluido en la luminaria
Instalación con grapa metálica
1 2
3 4
leaderBS-100 elite
2x54
143
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
The LUCE TL features:Low pro�le & compact design.
Operates T8, T5 & Compact Fluorescent lamps.
AC output ensures compatibility with newer lamp
technologies
Time delay to prevent false tripping of AC ballast.
Rated for damp location installations.
Single test switch / monitor LED.
EMER
GEN
CY B
ALL
AST
S
EMERGENCY BALLASTS
LUCE TL
LUCE TL7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR
PRODUCT OVERVIEWThe LUCE-TL thinline emergency ballast is designed to provide emergency illumination to existing or new �uores-cent luminaires. The LUCE-TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing.
Features Bene�ts
INDOOR/DAMP
10”L
LUCE TL
1.1875”H
2” W
1
9.5”
DIMENSIONS
Model A B C D
LUCE-1TL 1.1875” H 10” L 9.5”M
33.3400mm 339.73mm 57.15mm 241.30mm
Model Description
LUCE-1TL compact �uorescent lamp (without integral starter)
LUCE-2TLlamp (without integral starter)
LUCE-3TL lamp(s) (including rapid start, U-shape and circline) or one (1) or two (2)
13.375”L
LUCE TL
1.3125”H
2.25” W
2
12.75”
Model A B C D
LUCE-2TL 1.3125” H 13.375” L 12.75”M
33.3400mm 339.73mm 57.15mm 323.50mm
14.25”L
LUCE TL
1.1875”H
2.0625” W
3
13.75”
Model A B C D
LUCE-3TL 1.1875” H 14.25” L 13.75”M
30.163mm 361.95mm 52.388mm 349.25mm
LUCE-TL1
LUCE-TL2
LUCE-TL3
LUCE TL
1
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR
2
Job/Location:
Contractor: Job Type:
Date:Prepared By:
LUCE 1TL
PRODUCT OVERVIEWThe LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new �uorescent luminaires. The LUCE-1TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing.
The LUCE-1TL thinline emergency ballast can be used with one (1) 8W-34W T5, T8 or T12 �uorescent lamp (including rapid start, U-shape and circline) or one (1) 13W - 18W 4-pin compact �uorescent lamp (without integral starter). The LUCE-1TL is
.stsallab CA gnimmid dna cinortcele tsom htiw elbitapmocRated for use in damp location luminaires. The LUCE-1TL is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please contact the factory for speci�c lamp and ballast compatibility. The LUCE-1TL features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts ‘end of life’ shut down circuitry.
Thermoplastic 6V Battery Unit500 Lumens, (1) Lamp
Model Description
LUCE-1TL450 - 500 lumens, (1) 8W-34W T5, T8 or T12 �uorescent lamp (including rapid start, U-shape and circline) or (1) 13W - 18W 4-pin compact �uorescent lamp (without integral starter)
DIMENSIONS
10”L
LUCE TL
1.1875”H
2” W
1
9.5”
INDOOR/DAMP
The LUCE-1TL thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low pro�le,
.H”5781.1 x W”2 x L”01 serusaem taht gnisuoh leets tcapmocA single, low voltage LED monitor / test switch is standard equipment. The LUCE-1TL is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire.
APPLICATION
SPECIFICATION
During AC power failure, the LUCE-1TL thinline immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE-1TL automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts ‘end of life’ shut down circuitry.
The LUCE-1TL yrotcaf raey-3 a serutaef seires enilnihtwarranty. Deliberate damage, misuse, improper installation and/or application e�ectively cancel the warranty.
OPERATION
WARRANTY
ORDERING INFORMATION
A
D
B
C
Model A B C DLUCE-1TL 1.1875” H 10” L 2”W 9.5”M
33.3400mm 339.73mm 57.15mm 241.30mm
EMER
GEN
CY B
ALL
AST
S
2
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
EMER
GEN
CY B
ALL
AST
S
Technical LUCE 1TL
UL Listed Dual Voltage Input Test Switch / Charge Indicator Temperature Rating (Ambient)
Damp Location Factory or Field installation
120/277 VAC 60Hz Low Voltage monitor LED and test switch
0°C TO +50°C (32°F TO 122°F)
Illumination Ac Input Current Battery Charging Current Weight
90 Minutes 130mA 110mA 1.4LBS (0.6 KG)
Initial Light Output Ac Input Power Rating Recharge Time
450 - 500 LUMENS 3.0 Watts 24 Hours
Dimensions Battery Full Warranty
10”L x 2”W x 1.1875”H(254mm x 50.8mm x 30.16mm)Mounting center 9.5625”
4.8V / 2.0AhHigh-temperatureMaintenance-freeNickel Cadmium
3 years (NOT pro-rated)
The LUCE-1TL thinline emergency ballast uses a specially constructed, high-temperature nickel cadmium battery.
BATTERY
The LUCE-1TL thinline emergency ballast produces an initial 500 lumens during emergency operation. Designed to operate a single (1) lamp for a period no less then 90 minutes. Lumen output is less when using a compact �uorescent lamp.
EMERGENCY ILLUMINATION
The LUCE-1TL thinline emergency ballast does not e�ect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE-1TL. The LUCE-1TL must be fed from the same branch circuit as the AC ballast. The LUCE-1TL may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0C for extended periods.
INSTALLATION
The LUCE-1TL thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, “Emergency Lighting and Power Equipment,” and is UL Listed for factory or �eld installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA–LSC) and UL 90-minute requirements.
UL AND CODE COMPLIANCE
PRODUCT SUMMARY
UL Listed.
3
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR
EMER
GEN
CY B
ALL
AST
S Job/Location:
Contractor: Job Type:
Date:Prepared By:
Job/Location:
Contractor: Job Type:
Date:Prepared By:
Job/Location:
Contractor: Job Type:
Date:Prepared By:
LUCE 2TL
PRODUCT OVERVIEWThe LUCE-2TL thinline emergency ballast is designed to provide emergency illumination to existing or new �uorescent luminaires. The LUCE-2TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing.
The LUCE-2TL thinline emergency ballast can be used with one (1) 8W-40W T5, T8 or T12 �uorescent lamp (including rapid start, U-shape and circline) or one (1) 13W - 50W 4-pin compact �uorescent lamp (without integral starter). The LUCE-2TL is compatible with most electronic and dimming AC ballasts. Rated for use in damp location luminaires. The LUCE-2TL is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please contact the factory for speci�c lamp and ballast compatibility. The LUCE-2TL features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts end of life’ shut down circuitry.
Thermoplastic 6V Battery Unit700 Lumens, (1) Lamp
Model Description
LUCE-2TL700 lumens, (1) 8W-40W T5, T8 or T12 �uorescent lamp (including rapid start, U-shape and circline) or (1) 13W - 50W 4-pin compact �uorescent lamp (without integral starter)
DIMENSIONS
INDOOR/DAMP
The LUCE-2TL thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low pro�le, compact steel housing that measures 13.375”L x 2.25”W x 1.3125”H. A single, low voltage LED monitor / test switch is standard equipment. The LUCE-2TL is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire.
APPLICATION
SPECIFICATION
During AC power failure, the LUCE-2TL thinline immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE-2TL automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts ‘end of life’ shut down circuitry.
The LUCE-2TL yrotcaf raey-3 a serutaef seires enilniht warranty. Deliberate damage, misuse, improper installation and/or application e�ectively cancel the warranty.
OPERATION
WARRANTY
ORDERING INFORMATION
13.375”L
LUCE TL
1.3125”H
2.25” W
2
12.75”
A
D
B
C
Model A B C DLUCE-2TL 1.3125” H 13.375” L 2.25”W 12.75”M
33.3400mm 339.73mm 57.15mm 323.50mm
4
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
EMER
GEN
CY B
ALL
AST
S
Technical LUCE 2TL
UL Listed Dual Voltage Input Test Switch / Charge Indicator Temperature Rating (Ambient)
Damp Location Factory or Field installation
120/277 VAC 60Hz Low Voltage monitor LED and test switch
0°C TO +50°C (32°F TO 122°F)
Illumination Ac Input Current Battery Charging Current Weight
90 Minutes 180mA 160mA 2.0LBS (0.9 KG)
Initial Light Output Ac Input Power Rating Recharge Time
700 LUMENS 2.7 Watts 24 Hours
Dimensions Battery Full Warranty
13.375”L x 2.25”W x 1.3125”H(339.73mm x 57.15mm x 33.3400mm)Mounting center 12.875”
6V / 2.5AhHigh-temperatureMaintenance-freeNickel Cadmium
3 years (NOT pro-rated)
The LUCE-2TL thinline emergency ballast uses a specially constructed, high-temperature nickel cadmium battery.
BATTERY
The LUCE-2TL thinline emergency ballast produces an initial 700 lumens during emergency operation. Designed to operate a single (1) lamp for a period no less then 90 minutes. Lumen output is less when using a compact �uorescent lamp.
EMERGENCY ILLUMINATION
The LUCE-2TL thinline emergency ballast does not e�ect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE-2TL. The LUCE-2TL must be fed from the same branch circuit as the AC ballast. The LUCE-2TL may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0C for extended periods.
INSTALLATION
The LUCE-2TL thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, “Emergency Lighting and Power Equipment,” and is UL Listed for factory or �eld installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA–LSC) and UL 90-minute requirements.
UL AND CODE COMPLIANCE
PRODUCT SUMMARY
UL Listed.
5
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR
EMER
GEN
CY B
ALL
AST
S Job/Location:
Contractor: Job Type:
Date:Prepared By:
Job/Location:
LUCE 3TL
PRODUCT OVERVIEWThe LUCE-3TL thinline emergency ballast is designed to provide emergency illumination to existing or new �uorescent luminaires. The LUCE-3TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing.
The LUCE-3TL thinline emergency ballast can be used with one (1) or two (2) 17W-40W T5, T8 or T12 �uorescent lamp(s) (including rapid start, U-shape and circline) or one (1) or two (2) 13W - 50W 4-pin compact �uorescent lamp(s) (without integral starter). The LUCE-3TL is compatible with most electronic and dimming AC ballasts. Rated .serianimul noitacol pmad ni esu rofThe LUCE-3TL is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please
.ytilibitapmoc tsallab dna pmal cificeps rof yrotcaf eht tcatnocThe LUCE-3TL features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts ‘end of life’ shut down circuitry.
Thermoplastic 6V Battery Unit1400 Lumens, (1) or (2) Lamps
Model Description
LUCE-3TL1400 lumens, one (1) or two (2) 17W-40W T5, T8 or T12 �uorescent lamp(s) (including rapid start, U-shape and circline) or one (1) or two (2) 13W - 50W 4-pin compact �uorescent lamp(s) (without integral starter)
DIMENSIONS
14.25”L
LUCE TL
1.1875”H
2.0625” W
3
13.75”
Model A B C DLUCE-3TL 1.1875” H 14.25” L 2.0625”W 13.75”M
30.163mm 361.95mm 52.388mm 349.25mm
INDOOR/DAMP
The LUCE-3TL thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low pro�le, compact steel housing that measures 14.25”L x 2.0625”W x 1.1875”H. A single, low voltage LED monitor / test switch is standard equipment. The LUCE-3TL is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire.
APPLICATION
SPECIFICATION
During AC power failure, the LUCE-3TL thinline immediately switches to the emergency mode, keeping one or two lamp(s) illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE-3TL automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts ‘end of life’ shut down circuitry.
The LUCE-3TL yrotcaf raey-3 a serutaef seires enilniht warranty. Deliberate damage, misuse, improper installation and/or application e�ectively cancel the warranty.
OPERATION
WARRANTY
ORDERING INFORMATION
A
B
C
D
6
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
EMER
GEN
CY B
ALL
AST
S
Technical LUCE 3TL
UL Listed Dual Voltage Input Test Switch / Charge Indicator Temperature Rating (Ambient)
Damp Location Factory or Field installation
120/277 VAC 60Hz Low Voltage monitor LED and test switch
0°C TO +50°C (32°F TO 122°F)
Illumination Ac Input Current Battery Charging Current Weight
90 Minutes 180mA 160mA 2.0LBS (0.9 KG)
Initial Light Output Ac Input Power Rating Recharge Time
1400 LUMENS 2.7 Watts 24 Hours
Dimensions Battery Full Warranty
14.25”x L 2.0625”x W 1.1875”x H(361.95mm x 52.388mm x 30.163mm)Mounting center 12.875”
6V / 2.5AhHigh-temperatureMaintenance-freeNickel Cadmium
3 years (NOT pro-rated)
The LUCE-3TL thinline emergency ballast uses a specially constructed, high-temperature nickel cadmium battery.
BATTERY
The LUCE-3TL thinline emergency ballast produces an initial 1400 lumens during emergency operation. Designed to operate
.setunim 09 neht ssel on doirep a rof spmal )2( owt ro )1( enoLumen output is less when using a compact �uorescent lamp.
EMERGENCY ILLUMINATION
The LUCE-3TL thinline emergency ballast does not e�ect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE-3TL. The LUCE-3TL must be fed from the same branch circuit as the AC ballast. The LUCE-3TL may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0C for extended periods.
INSTALLATION
The LUCE-3TL thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, “Emergency Lighting and Power Equipment,” and is UL Listed for factory or �eld installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA–LSC) and UL 90-minute requirements.
UL AND CODE COMPLIANCE
PRODUCT SUMMARY
UL Listed.
7
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR
UCE - Emeregency ballastThe LUCE series of emergency ballasts are designed to provide emergency illumination capability to existing or new �uorescent �xtures. LUCE series products consist of an internal nickel cad-mium battery, charger and electronic circuit. A durable steel housing contains all components of the LUCE series. The LUCE series is available from 500 - 3000 lumens. The LUCE series is available for indoor, cold temperature, and damp location instal-lations. Please consult Beghelli USA Customer Service for ac-curate installation speci�cations when ordering.
OIS NNEMID SSeries A B CLUCE-4 16.3” 5.5” 1.7”LUCE-5 9.5” 2.375” 1.5”LUCE-6 9.5” 2.375” 1.5”LUCE-7 9.5” 2.375” 1.5”LUCE-8 17.5” 1.18” 1.15”LUCE-9 21.5” 1.18” 1.15”OPTIONS
Ballast Covers -BC (contact factory)
Flex Conduit -FX (please speci�c length)
Auto Test - AT -luce-3, luce-4, luce-7
DIMENSIONSModel Lumens # Lamps Description
LUCE-4 3000 1, 2
LUCE-5 650 1, 2 7, 9, 12w twin tube, 2 pin CF 9-13w quad tube, 2 pin CF
LUCE-6 650 1 18-26w quad tube, 2 pin CF
LUCE-7 650 1 10-42w 4 pin rapid start CF
LUCE-8 825 1 2’-4’ T5-T5HO linear, 40-55w 4 pin CF
LUCE-9 1300 1 2’-4’ T5-T5HO linear, 40-55w 4 pin CF
UCE PLUSIf you are unable to locate the speci�c LUCE model to meet your requirements; please contact Beghelli USA Customer Service at 1-800-723-4316. Additional LUCE series products are available upon request. Proper speci�cations are required.
INSTALLATIONThe LUCE series is suitable for new build and retro�t installa-tions. Indoor, cold temperature and damp location models are available to be con�gured for installation on normally in�am-mable surfaces.
LUCE Ballast
WARRANTYThe LUCE Series comes with a 5-year factory warranty. Deliber-ate damage, misuse, improper installation e�ectively cancel the warranty.
8
L
L
7222 NW 56 ST, Miami FL 33166 - www.americanrr.com - E-mail: [email protected] - Phone: 1.786.497.8898
AmericanRR