CONTRATO DE CONSULTORIA
ELABORACIÓN DE LOS ESTUDIOS YDISEÑO PARA LA CONSTRUCCIÓN DEL
CENTRO DE SALUD DEL CORREGIMIENTODE TANELA EN EL MUNICIPIO DE UNGUIA -
CHOCÓ
MEMORIA ESTRUCTURAL DEL CENTRO DESALUD DE TANELA
QUIBDÓ – 2015
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 2/89
MEMORIA DE CÁLCULO DE CENTRO DE SALUD EN EL
C ORREGIMIENTO DE T ANELA, M UNICIPIO DE U NGUIA,
DEPARTAMENTO DEL CHOCÓ.
Dirección
CORREGIMIENTO DE TANELA.
Propietarios:
CARMEM MORENO SERNA
Diseño Estructural
__________________________________Harry Alejandro Pineda Padilla.
Ingeniero CivilM.P. 05202094410 ANTIOQUIA
QUIBDÓ D.C., ABRIL DE 2015
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 3/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
3
Contenido
MEMORIA DE CÁLCULO ....................................................................................................................... 5
1.1. Justificación de la solución adoptada ............................................................................................................... 5
1.2. Estructura .......................................................................................................................................................... 5
1.3. Cimentación ...................................................................................................................................................... 5
1.4. Método de cálculo ............................................................................................................................................. 6
1.4.1. Hormigón armado ....................................................................................................................................... 6
1.4.2. Acero laminado y conformado ................................................................................................................... 6
1.4.3. Muros de fábrica de ladrillo y bloque de hormigón de árido, denso y ligero.............................................. 6
1.5. Cálculos por Ordenador .................................................................................................................................... 7
2. Características de los materiales a utilizar .......................................................................................... 7
2.1. Hormigón armado ............................................................................................................................................. 7
2.1.1. Hormigones ................................................................................................................................................ 7
2.1.2. Acero en barras .......................................................................................................................................... 7
2.1.3. Acero en Mallazos ...................................................................................................................................... 7
2.1.4. Ejecución .................................................................................................................................................... 7
2.2. Aceros laminados.............................................................................................................................................. 8
2.3. Aceros conformados ......................................................................................................................................... 8
2.4. Uniones entre elementos .................................................................................................................................. 8
2.5. Muros de fábrica ............................................................................................................................................... 8
2.6. Ensayos a realizar............................................................................................................................................. 8
2.7. Distorsión angular y deformaciones admisibles ............................................................................................... 8
ACCIONES ADOPTADAS EN EL CÁLCULO ......................................................................................... 9
3. Acciones Gravitatorias ........................................................................................................................ 9
3.1. Cargas superficiales.......................................................................................................................................... 9
3.1.1. Peso propio del forjado .............................................................................................................................. 9
3.1.2. Pavimentos y revestimientos ..................................................................................................................... 9
3.1.3. Sobrecarga de tabiquería ........................................................................................................................... 9
3.1.4. Sobrecarga de uso ..................................................................................................................................... 9
3.2. Cargas lineales ............................................................................................................................................... 10
3.2.1. Peso propio de las fachadas .................................................................................................................... 10
3.2.2. Peso propio de las particiones pesadas .................................................................................................. 10
3.2.3. Sobrecarga en voladizos .......................................................................................................................... 10
3.3. Cargas horizontales en barandas y antepechos ............................................................................................ 10
4. Acciones del viento ........................................................................................................................... 10
4.1. Altura de coronación del edificio (en metros) ................................................................................................. 10 4.2. Grado de aspereza ......................................................................................................................................... 10
4.3. Presión dinámica del viento (en KN/m2) ......................................................................................................... 10
4.4. Zona eólica (según NSR 10) ........................................................................................................................... 10
5. Acciones sísmicas............................................................................................................................. 10
5.1. Clasificación de la construcción ...................................................................................................................... 10
5.2. Coeficiente de DISIPACIÓN DE ENERGIA .................................................................................................... 10
5.3. Aceleración Horizontal Pico Efectiva .............................................................................................................. 11
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 4/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 4
5.4. Aceleración de Amplificación .......................................................................................................................... 11
5.5. Tipo de Perfil del Suelo ................................................................................................................................... 11
5.6. Espectro de CÁLCULO ................................................................................................................................... 11
5.7. Fracción cuasi-permanente de sobrecarga .................................................................................................... 11
5.8. Ductilidad ......................................................................................................................................................... 11
5.9. Periodos de vibración de la estructura ............................................................................................................ 11
5.10. Método de cálculo empleado ........................................................................................................................ 11
6. Combinaciones de acciones consideradas ........................................................................................ 11
6.1. Hormigón Armado ........................................................................................................................................... 11
7. DATOS INTRODUCIDOS AL PROGRAMA ....................................................................................... 14
7.1. VERSIÓN DEL PROGRAMA Y NÚMERO DE LICENCIA .............................................................................. 15
7.1.1. VERSIÓN DEL PROGRAMA Y NÚMERO DE LICENCIA ....................................................................... 15
7.1.2. DATOS GENERALES DE LA ESTRUCTURA ......................................................................................... 15
7.1.3. NORMAS CONSIDERADAS .................................................................................................................... 15
7.1.4. ACCIONES CONSIDERADAS ................................................................................................................. 15
7.1.5. ESTADOS LÍMITE .................................................................................................................................... 17
7.1.6. SITUACIONES DE PROYECTO .............................................................................................................. 17
7.1.7. DATOS GEOMÉTRICOS DE GRUPOS Y PLANTAS ............................................................................. 25
7.1.8. DATOS GEOMÉTRICOS DE PILARES, PANTALLAS Y MUROS .......................................................... 25
7.1.9. DIMENSIONES, COEFICIENTES DE EMPOTRAMIENTO Y COEFICIENTES DE PANDEO PARACADA PLANTA ................................................................................................................................................... 26
7.1.10. LOSAS Y ELEMENTOS DE CIMENTACIÓN ........................................................................................ 26
7.1.11. MATERIALES UTILIZADOS .................................................................................................................. 26
8. RESULTADOS DEL PROGRAMA ..................................................................................................... 27
8.1. DESPLAZAMIENTO DE COLUMNAS ............................................................................................................ 28
8.2. DISTORSION DE COLUMNAS ...................................................................................................................... 32
8.3. ESFUERZOS Y ARMADO DE COLUMNAS Y MURO ................................................................................... 38
8.4. ARMADO DE VIGAS ...................................................................................................................................... 71
8.5. DISEÑO DE CIMENTACIÓN .......................................................................................................................... 77
8.6. CANTIDADES DE OBRA ................................................................................................................................ 87
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 5/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
5
MEMORIA DE CÁLCULO
1.1.JUSTIFICACIÓN DE LA SOLUCIÓN ADOPTADA El Proyecto Estructural contempla la construcción de una estructura de refuerzo de una edificación un (1) planta,propiedad del MUNICIPIO DE UNGUÍA, la construcción se realizará en un predio, que se encuentra ubicada enel corregimiento de Tanela, Unguia, departamento Chocó. La construcción tiene contempla en para usoINSTITUCIONAL.
La edificación tiene la categoría de construcción residencial con uso principal RESIDENCIAL, de acuerdo con elárea del lote a construir y la altura de la misma ( una planta). La categoría del lote es normal (está en el rangode 100-250 M2, hasta cuatro (4) pisos) y menor de 1000 M2 construidos).
El proyecto se ubica en zona de amenaza sísmica alta de acuerdo a la norma sismo resistente de 2010, NSR-10. El código base empleado para el análisis y diseño de la estructura es la Norma Colombiana de Diseño yConstrucción Sismo Resistente de 2010 de la Asociación Colombiana de Ingeniería Sísmica AIS, y SeismicDesign of Liquid-Containing Concrete Structures (ACI 318M-99).
El programa utilizado para el análisis y diseño de la estructura es CYPECAD 2015h, con el cual se obtiene todoel análisis estructural de la EDIFICACIÓN, que incluye acciones y desplazamientos de todos los elementos delsistema, MODULO DE FUNDACIONES para diseño de cimentación y AUTOCAD 2013 para la presentación delos planos.
1.2.ESTRUCTURA
En la Edificación planteada se calculó columnas, losa de macizas y vigas aéreas mediante un sistema estructuralde pórticos arriostrados en concreto reforzado, además los elementos no estructurales todo de acuerdo a lasnormas colombianas sismo resistentes del 2010, las cuales rigen el diseño y construcción de obras sismoresistente del país. Los materiales que componen el pórtico espacial, son concreto de 21.1MPa para vigas,columnas, pantallas, losa de entrepiso, cimentación, con refuerzo corrugado de 420MPa.
1.3.CIMENTACIÓN Se plantea una cimentación superficial ditecta mediante zapatas induales apoyada apartir 1.0m a 2.0m enconcreto reforzado amarradas con vigas de cimentación según las recomendaciones de cimentación de losestudios de suelo.
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 6/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 6
1.4.MÉTODO DE CÁLCULO
1.4.1.HORMIGÓN ARMADO
Para la obtención de las solicitaciones se ha considerado los principios de la Mecánica Racional y las teoríasclásicas de la Resistencia de Materiales y Elasticidad.
El método de cálculo aplicado es de los Estados Límites, en el que se pretende limitar que el efecto de lasacciones exteriores ponderadas por unos coeficientes, sea inferior a la respuesta de la estructura, minorando lasresistencias de los materiales.En los estados límites últimos se comprueban los correspondientes a: equilibrio, agotamiento o rotura,adherencia, anclaje y fatiga (si procede).
En los estados límites de utilización, se comprueba: deformaciones (flechas), y vibraciones (si procede).
Definidos los estados de carga según su origen, se procede a calcular las combinaciones posibles con loscoeficientes de mayoración y minoración correspondientes de acuerdo a los coeficientes de seguridad definidosen el art. 12º de la norma NSR 10 y las combinaciones de hipótesis básicas definidas en el art 13º de la normaNSR 10
Situaciones no sísmicas
Situaciones sísmicas
La obtención de los esfuerzos en las diferentes hipótesis simples del entramado estructural, se harán de acuerdoa un cálculo lineal de primer orden, es decir admitiendo proporcionalidad entre esfuerzos y deformaciones, elprincipio de superposición de acciones, y un comportamiento lineal y geométrico de los materiales y la estructura.
Para la obtención de las solicitaciones determinantes en el dimensionado de los elementos de los forjados (vigas,viguetas, losas, nervios) se obtendrán los diagramas envolventes para cada esfuerzo.
Para el dimensionado de los soportes se comprueban para todas las combinaciones definidas.
1.4.2.ACERO LAMINADO Y CONFORMADO
Se dimensiona los elementos metálicos de acuerdo a la norma ANSI/AISC 360-05 (LRFD) (USA)determinándose coeficientes de aprovechamiento y deformaciones, así como la estabilidad, de acuerdo a losprincipios de la Mecánica Racional y la Resistencia de Materiales.
Se realiza un cálculo lineal de primer orden, admitiéndose localmente plastificaciones de acuerdo a lo indicadoen la norma.
La estructura se supone sometida a las acciones exteriores, ponderándose para la obtención de los coeficientesde aprovechamiento y comprobación de secciones, y sin mayorar para las comprobaciones de deformaciones,de acuerdo con los límites de agotamiento de tensiones y límites de flecha establecidos.
Para el cálculo de los elementos comprimidos se tiene en cuenta el pandeo por compresión, y para los flectadosel pandeo lateral, de acuerdo a las indicaciones de la norma.
1.4.3.MUROS DE FÁBRICA DE LADRILLO Y BLOQUE DE HORMIGÓN DE ÁRIDO, DENSO Y LIGERO
Para el cálculo y comprobación de tensiones de las fábricas de ladrillo se tendrá en cuenta lo indicado en lanorma NSR 10, y el Eurocódigo-6 en los bloques de hormigón.
El cálculo de solicitaciones se hará de acuerdo a los principios de la Mecánica Racional y la Resistencia deMateriales.
Se efectúan las comprobaciones de estabilidad del conjunto de las paredes portantes frente a accioneshorizontales, así como el dimensionado de las cimentaciones de acuerdo con las cargas excéntricas que lesolicitan.
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 7/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
7
1.5.CÁLCULOS POR ORDENADOR Para la obtención de las solicitaciones y dimensionado de los elementos estructurales, se ha dispuesto de unprograma informático de ordenador.
Con el programa CYPECAD 2015h calculamos las columnas, vigas, losas de entre piso, muros, zapatasindividuales y vigas de cimentación.
2.CARACTERÍSTICAS DE LOS MATERIALES A UTILIZAR Los materiales a utilizar así como las características definitorias de los mismos, niveles de control previstos, asícomo los coeficientes de seguridad, se indican en el siguiente cuadro:
2.1.HORMIGÓN ARMADO 2.1.1.HORMIGONES
Elementos de Hormigón Armado
Toda la obra CimentaciónSoportes
(Comprimidos)Forjados
(Flectados)Otros
Resistencia Característica a los 28 días: f ck (N/mm2) 25 25 25 25 25
Tipo de cemento (RC-03) CEM I/32.5 N
Cantidad máxima/mínima de cemento (kp/m3) 400/300
Tamaño máximo del árido (mm) 30 30 15/20 25
Tipo de ambiente (agresividad) I
Consistencia del hormigón Plástica Blanda Blanda Blanda
Asiento Cono de Abrams (cm) 3 a 5 6 a 9 6 a 9 6 a 9
Sistema de compactación Vibrado
Nivel de Control Previsto Estadístico
Coeficiente de Minoración 1.5
Resistencia de cálculo del hormigón: f cd (N/mm2) 16.66 16.66 16.66 16.66 16.66
2.1.2.ACERO EN BARRAS
Toda la obra Cimentación Comprimidos Flectados Otros
Designación B-400-S 4200Kg/cm2 4200Kg/cm2 4200Kg/cm2
Límite Elástico (N/mm2) 400
Nivel de Control Previsto Normal
Coeficiente de Minoración 1.15
Resistencia de cálculo del acero (barras): f yd (N/mm2) 347.82
2.1.3.ACERO EN MALLAZOS
Toda la obra Cimentación Comprimidos Flectados Otros
Designación B-500-T
Límite Elástico (kp/cm2) 500
2.1.4.EJECUCIÓN
Toda la obra Cimentación Comprimidos Flectados Otros
A. Nivel de C ontrol previs to Normal
B. Coeficiente de Mayoración de las acciones desfavorables
Permanentes/Variables
1.35/1.5
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 8/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 8
2.2.ACEROS LAMINADOS
Toda la obra Comprimidos Flectados Traccionados Placasanclaje
Acero en PerfilesClase y Designación S275
Límite Elástico (N/mm2) 275
Acero en ChapasClase y Designación S275
Límite Elástico (N/mm2) 275
2.3.ACEROS CONFORMADOS
Toda la obra Comprimidos Flectados TraccionadosPlacasanclaje
Acero en PerfilesClase y Designación S235
Límite Elástico (N/mm2) 235
Acero en Placas yPaneles
Clase y Designación S235
Límite Elástico (N/mm2) 235
2.4.UNIONES ENTRE ELEMENTOS
Toda la obra Comprimidos Flectados TraccionadosPlacasanclaje
Sistema yDesignación
Soldaduras
Tornillos Ordinarios A-4t
Tornillos Calibrados A-4t
Tornillo de Alta Resist. A-10t
Roblones
Pernos o Tornillos de Anclaje B-400-S
2.5.MUROS DE FÁBRICA No se utilizo
2.6.ENSAYOS A REALIZAR Hormigón Armado. De acuerdo a los niveles de control previstos, se realizaran los ensayos pertinentes de losmateriales, acero y hormigón según se indica en la norma Cap. XVI, art. 85º y siguientes.
Aceros estructurales. Se harán los ensayos pertinentes de acuerdo a lo indicado
2.7.DISTORSIÓN ANGULAR Y DEFORMACIONES ADMISIBLES Distorsión angular admisible en la cimentación. De acuerdo a la norma NSR 10, artículo A.6.4 en la tabla A.6.4-1,y en función del tipo de estructura, se considera aceptable un asiento máximo admisible de:
Límites de deformación de la estructura. Según lo expuesto en la norma NSR 10, artículo A.6.4 en la tabla A.6.4-1, se han verificado en la estructura las flechas de los distintos elementos. Se ha verificado tanto el desplome
local como el total de acuerdo con lo expuesto en A.6.4 de la NSR 10.Hormigón armado. Para el cálculo de las flechas en los elementos flectados, vigas y forjados, se tendrán encuenta tanto las deformaciones instantáneas como las diferidas, calculándose las inercias equivalentes deacuerdo a lo indicado en la norma.
Para el cálculo de las flechas se ha tenido en cuenta tanto el proceso constructivo, como las condicionesambientales, edad de puesta en carga, de acuerdo a unas condiciones habituales de la práctica constructiva enla edificación convencional. Por tanto, a partir de estos supuestos se estiman los coeficientes de fluenciapertinentes para la determinación de la flecha activa, suma de las flechas instantáneas más las diferidasproducidas con posterioridad a la construcción de las tabiquerías.
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 9/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
9
En los elementos de hormigón armado se establecen los siguientes límites:
Flechas activas máximas relativas y absolutas para elementos de Hormigón Armado y Acero
Estructura no solidaria con otros elementos
Estructura solidaria con otros elementos
Tabiques ordinarios o pavimentos rígidos con juntas
Tabiques frágileso pavimentos rígidos sin juntas
VIGAS Y LOSAS
Relativa: /L<1/300
FORJADOS UNIDIRECCIONALES
Relativa: /L<1/300
Relativa: /L<1/240
Relativa: /L<1/500
/L<1/1000+0.5cm
Relativa: /L<1/500
Relativa: /L<1/500
/L<1/1000+0.5cm
Desplazamientos horizontales
Local Total
Desplome relativo a la altura entre plantas:
/h<1/250
Desplome relativo a la altura total del edificio:
/H<1/500
ACCIONES ADOPTADAS EN EL CÁLCULO
3.ACCIONES GRAVITATORIAS
3.1.CARGAS SUPERFICIALES
3.1.1.PESO PROPIO DEL FORJADO
Se ha dispuesto los siguientes tipos de forjados:
Forjados de losa Mixta. Los cantos de las losas son:
Planta Canto (cm)
Cubierta 12
El peso propio de las losas se obtiene como el producto de su canto en metros por 24 kN/m3. Zonas macizadas. El peso propio de las zonas macizas se obtiene como el producto de su canto en metros por 24 kN/m3.
Zonas aligeradas. Las zonas aligeradas de los forjados se han indicado en el apartado de peso propio.
3.1.2.PAVIMENTOS Y REVESTIMIENTOS
Planta Zona Carga en KN/m2
Planta Zona Carga en KN/m2
Planta tipo Toda 1
Planta Zona Carga en KN/m2
Cubierta Toda 2.5
3.1.3.SOBRECARGA DE TABIQUERÍA
Planta Zona Carga en KN/m2
Planta Baja Toda 1.5
3.1.4.SOBRECARGA DE USO
Planta Zona Carga en KN/m2
Planta tipo Institusional 1.8
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 10/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 10
Planta Zona Carga en KN/m2
Cubierta Toda (No visitable) 1
3.2.CARGAS LINEALES
3.2.1.PESO PROPIO DE LAS FACHADAS
Planta Zona Carga en KN/ml
Planta Baja Toda 4
3.2.2.PESO PROPIO DE LAS PARTICIONES PESADAS
Planta Zona Carga en KN/ml
Planta Baja Medianeras 3
Planta Zona Carga en KN/ml
Planta tipo Medianeras 3
3.2.3.SOBRECARGA EN VOLADIZOS
Planta Zona Carga en KN/mlPlanta Baja Toda 2
3.3.CARGAS HORIZONTALES EN BARANDAS Y ANTEPECHOS Planta Zona Carga en KN/ml
Planta Baja Toda 1
4.ACCIONES DEL VIENTO
4.1.ALTURA DE CORONACIÓN DEL EDIFICIO (EN METROS) Altura del edificio es 13mts
4.2.GRADO DE ASPEREZA
EL edificio tiene una categoría II4.3.PRESIÓN DINÁMICA DEL VIENTO (EN KN/M2)
La velocidad es de 22 m/s
4.4. ZONA EÓLICA (SEGÚN NSR 10)La variación de la velocidad del viento con la direcciones en el país se clasifica en 5 regiones, nuestraedificación se encuentra en la zona 1, con una velocidad de 22m/s(75Km/h).
5.ACCIONES SÍSMICAS De acuerdo a la norma de construcción sismo resistente NSR 10, por el uso y la situación del edificio, en eltérmino municipal de se encuentra en zona de alto riesgo sísmico.
5.1.CLASIFICACIÓN DE LA CONSTRUCCIÓN
. El grado de disipación de energía es especial se consideran las acciones sísmicas por encontrarse en zonade alto riesgo sísmico
5.2.COEFICIENTE DE DISIPACIÓN DE ENERGIADependiendo del tipo de material estructural y de las características del sistema de resistencia sísmica seestablecen los grados de capacidad de disipación de energía mínimos (DES, DMO o DMI) que debe cumplir elmaterial estructural en las diferentes zonas de amenaza sísmica (Véanse las tablas A.3-1 a A.3-4 del ReglamentoNSR-10).
Coeficiente de disipación de energía en x = 7.0
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 11/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
11
Coeficiente de disipación de energía en y = 7.0
5.3.ACELERACIÓN HORIZONTAL PICO EFECTIVA Los movimientos sísmicos de diseño se definen en función de la aceleración pico efectiva, representada
por el parámetro Aa y de la velocidad pico efectiva representada por el parámetro Av, para una probabilidad deldiez por ciento de ser excedidos en un lapso de cincuenta años. para zona de alto riesgo donde se encuentraQuibdó es de 0.35g.
5.4.ACELERACIÓN DE AMPLIFICACIÓN Coeficiente de amplificación de la aceleración en zona de periodos cortos (NSR-10, Tabla A.2.4-3) es
Fa = 1.05.
Coeficiente de amplificación de la aceleración en zona de periodos intermedios (NSR-10, Tabla A.2.4-4) es Fv = 2.60
5.5.TIPO DE PERFIL DEL SUELO
El tipo de perfil del suelo se define en base de la velocidad media de la honda cortante (vs) de los estratos queforman los 30m superiores del terreno, para nuestra edificación el perfil del suelo es E
5.6.ESPECTRO DE CÁLCULOEl espectro de diseño sísmico se obtiene reduciendo el espectro elástico por el coeficiente (R) correspondientea cada dirección de análisis.
5.7.FRACCIÓN CUASI-PERMANENTE DE SOBRECARGA En función del uso del edificio, la parte de la sobrecarga a considerar en la masa sísmica movilizable será de0.8
5.8.DUCTILIDAD De acuerdo al tipo de estructura diseñada, la ductilidad considerada es ESPECIAL.
5.9.PERIODOS DE VIBRACIÓN DE LA ESTRUCTURA Se indican en los listados de resultados del cálculo.
5.10.MÉTODO DE CÁLCULO EMPLEADO Método de la fuerza lateral equivalente (NSR-10, A.4)
6.COMBINACIONES DE ACCIONES CONSIDERADAS
6.1.HORMIGÓN ARMADO Hipótesis y combinaciones. De acuerdo con las acciones determinadas en función de su origen, y teniendo encuenta tanto si el efecto de las mismas es favorable o desfavorable, así como los coeficientes de ponderaciónse realizará el cálculo de las combinaciones posibles del modo siguiente:
Para cada situación de proyecto y estado límite los coeficientes a utilizar serán:
E.L.U. de rotura. Hormigón: NSR-10
E.L.U. de rotura. Acero laminado: ANSI/AISC 360-05 (LRFD)
(C.9-1)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.400 1.400
Sobrecarga (Q)
(C.9-2 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 12/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 12
(C.9-2 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Sobrecarga (Q) 0.000 1.600
(C.9-2 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
(C.9-3 Lr, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
(C.9-3 S, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
(C.9-3 Lr, W)Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
(C.9-3 S, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
(C.9-4 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
(C.9-4 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
(C.9-5)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Sismo (E) -1.000 1.000Notas:
Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
(C.9-6)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 13/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
13
(C.9-7)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Sismo (E) -1.000 1.000
Notas:
Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
E.L.U. de rotura. Hormigón en cimentaciones: NSR-10
Tensiones sobre el terreno
B2.3-1
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q)
B2.3-6
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q)
Sismo (E) -0.700 0.700
B2.3-10
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.600 0.600
Sobrecarga (Q)
Sismo (E) -0.700 0.700
Desplazamientos
Acciones variables sin sismo
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Sísmica
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Sismo (E) -1.000 1.000
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 14/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 14
7.DATOS INTRODUCIDOS AL PROGRAMA
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 15/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
15
7.1. VERSIÓN DEL PROGRAMA Y NÚMERO DE LICENCIA
7.1.1. VERSIÓN DEL PROGRAMA Y NÚMERO DE LICENCIA
Versión: 2015
Número de licencia: 117649
7.1.2.DATOS GENERALES DE LA ESTRUCTURA
Proyecto: PUESTO DE SALUD DE TANELA, MUNICIPIO DE UNGUIA - CHOCÓ
Clave: PUESTO DE SALUD - TANELA-CUBERTA OPTIMO
7.1.3.NORMAS CONSIDERADAS
Hormigón: NSR-10
Aceros conformados: AISI
Aceros laminados y armados: ANSI/AISC 360-10 (LRFD)
Categoría de uso: General
7.1.4.ACCIONES CONSIDERADAS
7.1.4.1. GRAVITATORIAS
PlantaS.C.U(t/m²)
Cargas muertas(t/m²)
CUBIERTA 0.20 0.30
PISO2 0.20 0.35
PISO1 0.20 0.30
Cimentación 0.00 0.00
7.1.4.2. VIENTO Reglamento colombiano de construcción sismo resistenteNSR-10 Capítulo B.6 - Fuerzas de viento
Categoría del terreno: Categoría D
Velocidad básica del viento: 22.00 m/s
Categoría IV
Anchos de banda
PlantasAncho de banda Y
(m)Ancho de banda X
(m)
En todas las plantas 24.00 15.00
No se realiza análisis de los efectos de 2º orden
Coeficientes de Cargas
+X: 1.00 -X:1.00
+Y: 1.00 -Y:1.00
Cargas de viento
Planta
Viento X
(t)
Viento Y
(t)CUBIERTA 0.500 0.286
PISO2 1.740 0.996
PISO1 0.000 0.000
7.1.4.3. SISMO
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 16/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 16
Norma utilizada: NSR-10
Reglamento Colombiano de Construcción Sismo Resistente (2010)
Método de cálculo: Método de la fuerza lateral equivalente (NSR-10, A.4)
7.1.4.3.1. Datos generales de sismo
Caracterización del emplazamiento
Aa: Aceleración horizontal pico efectiva (NSR-10, A.2.2) Aa : 0.35 g
Av: Velocidad horizontal pico efectiva (NSR-10, A.2.2) Av : 0.35 g
Vm: Velocidad media de onda de cortante (NSR-10, A.2.4.3) Vm : 180.00 m/s
Sistema estructural
R 0X: Coeficiente de disipación de energía básico (X) (NSR-10, A.3) R 0X : 7.00
R 0Y: Coeficiente de disipación de energía básico (Y) (NSR-10, A.3) R 0Y : 7.00
a: Coeficiente de irregularidad en altura (NSR-10, A.3.3.5) a : 1.00
p: Coeficiente de irregularidad en planta (NSR-10, A.3.3.4) p : 1.00
rX: Coeficiente por ausencia de redundancia (X) (NSR-10, A.3.3.8) rX : 0.75
rY: Coeficiente por ausencia de redundancia (Y) (NSR-10, A.3.3.8) rY : 0.75
Estimación del periodo fundamental de la estructura: Según norma
Tipología estructural (X): I
Tipología estructural (Y): I
h: Altura del edificio h : 4.20 m
Tipo de edificación (NSR-10, A.2.5): II
Parámetros de cálculo
Fracción de sobrecarga de uso : 0.00
Fracción de sobrecarga de nieve : 0.00
No se realiza análisis de los efectos de 2º orden
Criterio de armado a aplicar por ductilidad: Especial (DES)
Direcciones de análisis
Acción sísmica según X
Acción sísmica según Y
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 17/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
17
Proyección en planta de la obra
7.1.4.4. HIPÓTESIS DE CARGA
Automáticas Peso propioCargas muertasSobrecarga de usoSismo X 1
Sismo X 2Sismo Y 1Sismo Y 2Viento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-
7.1.5.ESTADOS LÍMITE
E.L.U. de rotura. HormigónE.L.U. de rotura. Hormigón en cimentaciones
NSR-10
E.L.U. de rotura. Acero laminado AISC 360-10 (LRFD)ASCE 7
Tensiones sobre el terrenoDesplazamientos
Acciones características
7.1.6.SITUACIONES DE PROYECTO
Para las distintas situaciones de proyecto, las combinaciones de acciones se definirán de acuerdo con los siguientes criterios:
- Situaciones persistentes o transitorias
- Situaciones sísmicas
- Donde:
Gk Acción permanente
Pk Acción de pretensado
Qk Acción variable
AE Acción sísmica
G Coeficiente parcial de seguridad de las acciones permanentes
P Coeficiente parcial de seguridad de la acción de pretensado
Q,1 Coeficiente parcial de seguridad de la acción variable principal
Q,i Coeficiente parcial de seguridad de las acciones variables de acompañamiento
AE Coeficiente parcial de seguridad de la acción sísmica
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 18/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 18
7.1.6.1. COEFICIENTES PARCIALES DE SEGURIDAD () Y COEFICIENTES DE COMBINACIÓN ()Para cada situación de proyecto y estado límite los coeficientes a utilizar serán:
E.L.U. de rotura. Hormigón: NSR-10
E.L.U. de rotura. Hormigón en cimentaciones: NSR-10
(C.9-1)
Coeficientes parciales de seguridad ()Favorable Desfavorable
Carga permanente (G) 1.400 1.400
Sobrecarga (Q)
Viento (Q)
(C.9-2 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
(C.9-2 S)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
(C.9-3 Lr, L)
Coeficientes parciales de seguridad ()Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
(C.9-3 S, L)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
(C.9-3 Lr, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.500
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 19/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
19
(C.9-3 S, W)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.500
(C.9-4 Lr)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.000 1.000
(C.9-4 S)
Coeficientes parciales de seguridad ()Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.000 1.000
(C.9-5)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Sismo (E) -1.000 1.000
Notas:Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
(C.9-6)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q) 0.000 1.000
(C.9-7)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q)
Sismo (E) -1.000 1.000
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 20/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 20
(C.9-7)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Notas:Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
E.L.U. de rotura. Acero laminado: ANSI/AISC 360-10 (LRFD)
2.3.2 - [1] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.400 1.400
Sobrecarga (Q)
Viento (Q)
2.3.2 - [2 Lr] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
2.3.2 - [2 S] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 1.600
Viento (Q)
2.3.2 - [3 Lr, L] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
2.3.2 - [3 S, L] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable DesfavorableCarga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 21/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
21
2.3.2 - [3 Lr, W] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.500
2.3.2 - [3 S, W] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q)
Viento (Q) 0.000 0.500
2.3.2 - [4 Lr] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.000 1.000
2.3.2 - [4 S] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q) 1.000 1.000
2.3.2 - [5] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.200 1.200
Sobrecarga (Q) 0.000 0.500
Viento (Q)
Sismo (E) -1.000 1.000
Notas:Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
2.3.2 - [6] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q) 0.000 1.000
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 22/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 22
2.3.2 - [7] (ASCE/SEI 7-10)
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 0.900 0.900
Sobrecarga (Q)
Viento (Q)
Sismo (E) -1.000 1.000
Notas:Las solicitaciones obtenidas de los resultados del análisis en cada una de las direcciones ortogonalesse combinarán con el 30 % de los de la otra.
Tensiones sobre el terreno
Acciones variables sin sismo
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Sísmica
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q)
Sismo (E) -1.000 1.000
Desplazamientos
Acciones variables sin sismo
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000
Sobrecarga (Q) 0.000 1.000
Viento (Q) 0.000 1.000
Sísmica
Coeficientes parciales de seguridad ()
Favorable Desfavorable
Carga permanente (G) 1.000 1.000Sobrecarga (Q) 0.000 1.000
Viento (Q)
Sismo (E) -1.000 1.000
7.1.6.2. COMBINACIONES Nombres de las hipótesis
PP Peso propio
CM Cargas muertas
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 23/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
23
Qa Sobrecarga de uso
V(+X exc.+) Viento +X exc.+
V(+X exc.-) Viento +X exc.-
V(-X exc.+) Viento -X exc.+
V(-X exc.-) Viento -X exc.-
V(+Y exc.+) Viento +Y exc.+
V(+Y exc.-) Viento +Y exc.-
V(-Y exc.+) Viento -Y exc.+V(-Y exc.-) Viento -Y exc.-
SX 1 Sismo X 1
SX 2 Sismo X 2
SY 1 Sismo Y 1
SY 2 Sismo Y 2
E.L.U. de rotura. Hormigón
E.L.U. de rotura. Hormigón en cimentaciones
E.L.U. de rotura. Acero laminado
Comb. PP CM Qa V(+X exc.+) V(+X exc.-) V(-X exc.+) V(-X exc.-) V(+Y exc.+) V(+Y exc.-) V(-Y exc.+) V(-Y exc.-) SX 1 SX 2 SY 1 SY 2
1 1.400 1.400
2 1.200 1.200
3 1.200 1.200 1.600
4 1.200 1.200 1.000
5 1.200 1.200 0.500 1.000
6 1.200 1.200 1.000
7 1.200 1.200 0.500 1.000
8 1.200 1.200 1.000
9 1.200 1.200 0.500 1.000
10 1.200 1.200 1.000
11 1.200 1.200 0.500 1.000
12 1.200 1.200 1.000
13 1.200 1.200 0.500 1.000
14 1.200 1.200 1.000
15 1.200 1.200 0.500 1.00016 1.200 1.200 1.000
17 1.200 1.200 0.500 1.000
18 1.200 1.200 1.000
19 1.200 1.200 0.500 1.000
20 1.200 1.200 -0.300 -1.000
21 1.200 1.200 0.500 -0.300 -1.000
22 1.200 1.200 -0.300 -1.000
23 1.200 1.200 0.500 -0.300 -1.000
24 1.200 1.200 0.300 -1.000
25 1.200 1.200 0.500 0.300 -1.000
26 1.200 1.200 0.300 -1.000
27 1.200 1.200 0.500 0.300 -1.000
28 1.200 1.200 -1.000 -0.300
29 1.200 1.200 0.500 -1.000 -0.300
30 1.200 1.200 -1.000 -0.30031 1.200 1.200 0.500 -1.000 -0.300
32 1.200 1.200 -1.000 0.300
33 1.200 1.200 0.500 -1.000 0.300
34 1.200 1.200 -1.000 0.300
35 1.200 1.200 0.500 -1.000 0.300
36 1.200 1.200 0.300 1.000
37 1.200 1.200 0.500 0.300 1.000
38 1.200 1.200 0.300 1.000
39 1.200 1.200 0.500 0.300 1.000
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 24/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 24
Comb. PP CM Qa V(+X exc.+) V(+X exc.-) V(-X exc.+) V(-X exc.-) V(+Y exc.+) V(+Y exc.-) V(-Y exc.+) V(-Y exc.-) SX 1 SX 2 SY 1 SY 2
40 1.200 1.200 -0.300 1.000
41 1.200 1.200 0.500 -0.300 1.000
42 1.200 1.200 -0.300 1.000
43 1.200 1.200 0.500 -0.300 1.000
44 1.200 1.200 1.000 0.300
45 1.200 1.200 0.500 1.000 0.300
46 1.200 1.200 1.000 0.300
47 1.200 1.200 0.500 1.000 0.300
48 1.200 1.200 1.000 -0.300
49 1.200 1.200 0.500 1.000 -0.300
50 1.200 1.200 1.000 -0.300
51 1.200 1.200 0.500 1.000 -0.300
52 0.900 0.900
53 0.900 0.900 1.000
54 0.900 0.900 1.000
55 0.900 0.900 1.000
56 0.900 0.900 1.000
57 0.900 0.900 1.000
58 0.900 0.900 1.000
59 0.900 0.900 1.000
60 0.900 0.900 1.000
61 0.900 0.900 -0.300 -1.00062 0.900 0.900 -0.300 -1.000
63 0.900 0.900 0.300 -1.000
64 0.900 0.900 0.300 -1.000
65 0.900 0.900 -1.000 -0.300
66 0.900 0.900 -1.000 -0.300
67 0.900 0.900 -1.000 0.300
68 0.900 0.900 -1.000 0.300
69 0.900 0.900 0.300 1.000
70 0.900 0.900 0.300 1.000
71 0.900 0.900 -0.300 1.000
72 0.900 0.900 -0.300 1.000
73 0.900 0.900 1.000 0.300
74 0.900 0.900 1.000 0.300
75 0.900 0.900 1.000 -0.300
76 0.900 0.900 1.000 -0.300
Tensiones sobre el terreno
Desplazamientos
Comb. PP CM Qa V(+X exc.+) V(+X exc.-) V(-X exc.+) V(-X exc.-) V(+Y exc.+) V(+Y exc.-) V(-Y exc.+) V(-Y exc.-) SX 1 SX 2 SY 1 SY 2
1 1.000 1.000
2 1.000 1.000 1.000
3 1.000 1.000 1.000
4 1.000 1.000 1.000 1.000
5 1.000 1.000 1.000
6 1.000 1.000 1.000 1.000
7 1.000 1.000 1.0008 1.000 1.000 1.000 1.000
9 1.000 1.000 1.000
10 1.000 1.000 1.000 1.000
11 1.000 1.000 1.000
12 1.000 1.000 1.000 1.000
13 1.000 1.000 1.000
14 1.000 1.000 1.000 1.000
15 1.000 1.000 1.000
16 1.000 1.000 1.000 1.000
17 1.000 1.000 1.000
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 25/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
25
Comb. PP CM Qa V(+X exc.+) V(+X exc.-) V(-X exc.+) V(-X exc.-) V(+Y exc.+) V(+Y exc.-) V(-Y exc.+) V(-Y exc.-) SX 1 SX 2 SY 1 SY 2
18 1.000 1.000 1.000 1.000
19 1.000 1.000 -1.000
20 1.000 1.000 1.000 -1.000
21 1.000 1.000 1.000
22 1.000 1.000 1.000 1.000
23 1.000 1.000 -1.000
24 1.000 1.000 1.000 -1.000
25 1.000 1.000 1.000
26 1.000 1.000 1.000 1.000
27 1.000 1.000 -1.000
28 1.000 1.000 1.000 -1.000
29 1.000 1.000 1.000
30 1.000 1.000 1.000 1.000
31 1.000 1.000 -1.000
32 1.000 1.000 1.000 -1.000
33 1.000 1.000 1.000
34 1.000 1.000 1.000 1.000
7.1.7.DATOS GEOMÉTRICOS DE GRUPOS Y PLANTAS
Grupo Nombre del grupo Planta Nombre planta Altura Cota
3 CUBIERTA 3 CUBIERTA 1.20 4.20
2 PISO2 2 PISO2 3.00 3.00
1 PISO1 1 PISO1 2.00 0.00
0 Cimentación -2.00
7.1.8.DATOS GEOMÉTRICOS DE PILARES, PANTALLAS Y MUROS
7.1.8.1. PILARES GI: grupo inicial
GF: grupo final
Ang: ángulo del pilar en grados sexagesimales
Datos de los pilaresReferencia Coord(P.Fijo) GI- GF Vinculación exterior Ang. Punto fijo Canto de apoyo
C1 ( 2.27, 4.59) 0-2 Con vinculación exterior 0.0 Centro 0.40
C2 ( 8.07, 4.59) 0-3 Con vinculación exterior 0.0 Centro 0.40
C3 ( 10.47, 4.59) 0-2 Con vinculación exterior 0.0 Centro 0.40
C4 ( 16.54, 4.59) 0-2 Con vinculación exterior 0.0 Centro 0.40
C5 ( 2.27, 8.89) 0-2 Con vinculación exterior 0.0 Centro 0.40
C6 ( 8.07, 8.89) 0-3 Con vinculación exterior 0.0 Centro 0.40
C7 ( 10.47, 8.89) 0-2 Con vinculación exterior 0.0 Centro 0.40
C8 ( 16.54, 8.89) 0-2 Con vinculación exterior 0.0 Centro 0.40
C9 ( 2.27, 13.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
C10 ( 8.07, 13.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
C11 ( 0.00, 16.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
C12 ( 6.37, 16.19) 0-3 Con vinculación exterior 0.0 Centro 0.40
C13 ( 10.47, 16.19) 0-2 Con vinculación exterior 0.0 Centro 0.40C14 ( 16.54, 16.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
C15 ( 22.41, 16.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
C16 ( 0.00, 22.94) 0-2 Con vinculación exterior 0.0 Centro 0.40
C17 ( 6.37, 22.94) 0-3 Con vinculación exterior 0.0 Centro 0.40
C18 ( 10.47, 22.94) 0-2 Con vinculación exterior 0.0 Centro 0.40
C19 ( 16.54, 22.94) 0-2 Con vinculación exterior 0.0 Centro 0.40
C20 ( 22.41, 22.94) 0-2 Con vinculación exterior 0.0 Centro 0.40
C21 ( 0.00, 28.54) 0-2 Con vinculación exterior 0.0 Centro 0.40
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 26/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 26
Referencia Coord(P.Fijo) GI- GF Vinculación exterior Ang. Punto fijo Canto de apoyo
C22 ( 6.37, 28.54) 0-3 Con vinculación exterior 0.0 Centro 0.40
C23 ( 10.47, 28.54) 0-2 Con vinculación exterior 0.0 Centro 0.45
C24 ( 16.54, 28.54) 0-2 Con vinculación exterior 0.0 Centro 0.40
C25 ( 22.41, 28.54) 0-2 Con vinculación exterior 0.0 Centro 0.40
C26 ( 10.47, 13.19) 0-2 Con vinculación exterior 0.0 Centro 0.40
7.1.9. DIMENSIONES, COEFICIENTES DE EMPOTRAMIENTO Y COEFICIENTES DE PANDEO PARA CADA PLANTA
Pilar PlantaDimensiones
(cm)Coeficiente de empotramiento Coeficiente de pandeo
Coeficiente de rigidez axilCabeza Pie X Y
C1, C3, C4, C5, C7,C8, C9, C10, C11,C13, C14, C15, C16,C18, C19, C20, C21,C23, C24, C25, C26
2 35x35 0.30 1.00 1.00 1.00 2.00
1 35x35 1.00 1.00 1.00 1.00 2.00
C2, C6, C12, C17,C22
3 35x35 0.30 1.00 1.00 1.00 2.00
2 35x35 1.00 1.00 1.00 1.00 2.00
1 35x35 1.00 1.00 1.00 1.00 2.00
7.1.10.LOSAS Y ELEMENTOS DE CIMENTACIÓN
-Tensión admisible en situaciones persistentes: 2.00 kp/cm²-Tensión admisible en situaciones accidentales: 4.00 kp/cm²
7.1.11.MATERIALES UTILIZADOS
7.1.11.1. HORMIGONES
Elemento Hormigónf ck
(kp/cm²) c Tamaño máximo del árido
(mm)
Todos f'c=210 210 1.00 15
7.1.11.2. ACEROS POR ELEMENTO Y POSICIÓN
7.1.11.2.1. Aceros en barras
Elemento Acerof yk
(kp/cm²) s
Todos Grado 60 (Latinoamérica) 4200 1.00
7.1.11.2.2. Aceros en perfiles
Tipo de acero para perfiles AceroLímite elástico
(kp/cm²)Módulo de elasticidad
(kp/cm²)
Acero conformado A-36 2548 2089704
Acero laminado ASTM A 36 36 ksi 2548 2038736
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 27/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
27
8.RESULTADOS DEL PROGRAMA
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 28/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 28
8.1.DESPLAZAMIENTO DE COLUMNAS
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)C1 PISO2 2.83 0.49 0.34 0.04
PISO1 -0.18 0.07 0.06 0.02
Cimentación -2.00 0.00 0.00 0.00
C2 CUBIERTA 4.20 0.94 0.22 0.06
PISO2 4.00 0.85 0.21 0.06
2.83 0.49 0.16 0.06
PISO1 -0.18 0.07 0.04 0.03
Cimentación -2.00 0.00 0.00 0.00
C3 PISO2 2.83 0.49 0.25 0.14
PISO1 -0.18 0.07 0.04 0.06
Cimentación -2.00 0.00 0.00 0.00
C4 PISO2 2.83 0.49 0.49 0.09
PISO1 -0.18 0.07 0.06 0.04
Cimentación -2.00 0.00 0.00 0.00
C5 PISO2 2.83 0.32 0.34 0.05
PISO1 -0.18 0.06 0.06 0.02
Cimentación -2.00 0.00 0.00 0.00
C6 CUBIERTA 4.20 0.70 0.27 0.09
PISO2 4.00 0.62 0.25 0.09
2.83 0.32 0.16 0.09
PISO1 -0.18 0.06 0.04 0.04
Cimentación -2.00 0.00 0.00 0.00
C7 PISO2 2.80 0.32 0.25 0.13
PISO1 -0.18 0.06 0.04 0.06
Cimentación -2.00 0.00 0.00 0.00
C8 PISO2 2.83 0.32 0.49 0.06
PISO1 -0.18 0.06 0.06 0.03
Cimentación -2.00 0.00 0.00 0.00
C9 PISO2 2.83 0.30 0.34 0.05
PISO1 -0.18 0.06 0.06 0.03
Cimentación -2.00 0.00 0.00 0.00
C10 PISO2 2.83 0.30 0.16 0.12PISO1 -0.18 0.06 0.04 0.05
Cimentación -2.00 0.00 0.00 0.00
C11 PISO2 2.83 0.40 0.42 0.04
PISO1 -0.18 0.07 0.06 0.02
Cimentación -2.00 0.00 0.00 0.00
C12 CUBIERTA 4.20 0.47 0.37 0.12
PISO2 4.00 0.48 0.32 0.12
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 29/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
29
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)
2.80 0.40 0.19 0.12
PISO1 -0.18 0.07 0.04 0.05
Cimentación -2.00 0.00 0.00 0.00
C13 PISO2 2.80 0.40 0.25 0.07
PISO1 -0.18 0.07 0.04 0.04
Cimentación -2.00 0.00 0.00 0.00
C14 PISO2 2.83 0.40 0.49 0.15
PISO1 -0.18 0.07 0.06 0.07
Cimentación -2.00 0.00 0.00 0.00
C15 PISO2 2.83 0.40 0.72 0.23
PISO1 -0.18 0.07 0.08 0.09
Cimentación -2.00 0.00 0.00 0.00
C16 PISO2 2.83 0.68 0.42 0.07
PISO1 -0.18 0.10 0.06 0.03
Cimentación -2.00 0.00 0.00 0.00
C17 CUBIERTA 4.20 0.85 0.24 0.15
PISO2 4.00 0.85 0.22 0.15
2.80 0.68 0.19 0.14
PISO1 -0.18 0.10 0.04 0.06
Cimentación -2.00 0.00 0.00 0.00
C18 PISO2 2.80 0.68 0.25 0.07
PISO1 -0.18 0.10 0.04 0.04
Cimentación -2.00 0.00 0.00 0.00
C19 PISO2 2.80 0.68 0.49 0.14
PISO1 -0.18 0.10 0.06 0.06
Cimentación -2.00 0.00 0.00 0.00
C20 PISO2 2.80 0.68 0.72 0.07
PISO1 -0.18 0.10 0.08 0.04
Cimentación -2.00 0.00 0.00 0.00
C21 PISO2 2.83 0.92 0.42 0.04
PISO1 -0.18 0.12 0.06 0.02
Cimentación -2.00 0.00 0.00 0.00
C22 CUBIERTA 4.20 0.96 0.46 0.08
PISO2 4.00 0.97 0.38 0.08
2.83 0.92 0.19 0.08PISO1 -0.18 0.12 0.04 0.04
Cimentación -2.00 0.00 0.00 0.00
C23 PISO2 2.83 0.92 0.25 0.04
PISO1 -0.18 0.12 0.04 0.02
Cimentación -2.00 0.00 0.00 0.00
C24 PISO2 2.83 0.92 0.49 0.14
PISO1 -0.18 0.12 0.06 0.06
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 30/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 30
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)
Cimentación -2.00 0.00 0.00 0.00
C25 PISO2 2.83 0.92 0.72 0.06
PISO1 -0.18 0.12 0.08 0.03
Cimentación -2.00 0.00 0.00 0.00
C26 PISO2 2.80 0.30 0.25 0.03
PISO1 -0.18 0.06 0.04 0.02
Cimentación -2.00 0.00 0.00 0.00
Situaciones sísmicas
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)
C1 PISO2 2.83 3.45 4.25 0.05
PISO1 -0.18 0.76 0.98 0.03
Cimentación -2.00 0.00 0.00 0.00
C2 CUBIERTA 4.20 4.09 5.62 0.08
PISO2 4.00 3.99 5.47 0.08
2.83 3.45 4.69 0.08
PISO1 -0.18 0.76 1.10 0.04
Cimentación -2.00 0.00 0.00 0.00
C3 PISO2 2.83 3.45 5.12 0.16
PISO1 -0.18 0.76 1.18 0.07
Cimentación -2.00 0.00 0.00 0.00
C4 PISO2 2.83 3.45 6.61 0.10
PISO1 -0.18 0.76 1.49 0.05
Cimentación -2.00 0.00 0.00 0.00
C5 PISO2 2.83 3.72 4.25 0.05
PISO1 -0.18 0.85 0.98 0.03
Cimentación -2.00 0.00 0.00 0.00
C6 CUBIERTA 4.20 4.32 5.61 0.11
PISO2 4.00 4.22 5.45 0.11
2.83 3.72 4.69 0.10
PISO1 -0.18 0.85 1.10 0.05
Cimentación -2.00 0.00 0.00 0.00
C7 PISO2 2.80 3.72 5.12 0.15
PISO1 -0.18 0.85 1.18 0.07
Cimentación -2.00 0.00 0.00 0.00
C8 PISO2 2.83 3.72 6.61 0.07
PISO1 -0.18 0.85 1.49 0.04
Cimentación -2.00 0.00 0.00 0.00
C9 PISO2 2.83 4.14 4.25 0.05
PISO1 -0.18 0.96 0.98 0.03
Cimentación -2.00 0.00 0.00 0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 31/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
31
Situaciones sísmicas
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)
C10 PISO2 2.83 4.14 4.69 0.14
PISO1 -0.18 0.96 1.10 0.06
Cimentación -2.00 0.00 0.00 0.00
C11 PISO2 2.83 4.54 4.09 0.05
PISO1 -0.18 1.05 0.93 0.03
Cimentación -2.00 0.00 0.00 0.00
C12 CUBIERTA 4.20 4.87 5.53 0.13
PISO2 4.00 4.86 5.34 0.13
2.80 4.54 4.54 0.13
PISO1 -0.18 1.05 1.07 0.06
Cimentación -2.00 0.00 0.00 0.00
C13 PISO2 2.80 4.54 5.12 0.08
PISO1 -0.18 1.05 1.18 0.04
Cimentación -2.00 0.00 0.00 0.00
C14 PISO2 2.83 4.54 6.61 0.15
PISO1 -0.18 1.05 1.49 0.07
Cimentación -2.00 0.00 0.00 0.00
C15 PISO2 2.83 4.54 8.05 0.24
PISO1 -0.18 1.05 1.80 0.10
Cimentación -2.00 0.00 0.00 0.00
C16 PISO2 2.83 6.22 4.09 0.08
PISO1 -0.18 1.42 0.93 0.04
Cimentación -2.00 0.00 0.00 0.00
C17 CUBIERTA 4.20 6.76 5.44 0.15
PISO2 4.00 6.72 5.28 0.15
2.80 6.22 4.54 0.15
PISO1 -0.18 1.42 1.07 0.07
Cimentación -2.00 0.00 0.00 0.00
C18 PISO2 2.80 6.22 5.12 0.08
PISO1 -0.18 1.42 1.18 0.04
Cimentación -2.00 0.00 0.00 0.00
C19 PISO2 2.80 6.22 6.61 0.14
PISO1 -0.18 1.42 1.49 0.07
Cimentación -2.00 0.00 0.00 0.00
C20 PISO2 2.80 6.22 8.05 0.09PISO1 -0.18 1.42 1.80 0.04
Cimentación -2.00 0.00 0.00 0.00
C21 PISO2 2.83 7.62 4.09 0.05
PISO1 -0.18 1.72 0.93 0.03
Cimentación -2.00 0.00 0.00 0.00
C22 CUBIERTA 4.20 8.20 5.73 0.10
PISO2 4.00 8.15 5.50 0.10
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 32/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 32
Situaciones sísmicas
Pilar PlantaCota
(m)
Desp. X
(mm)
Desp. Y
(mm)
Desp. Z
(mm)
2.83 7.62 4.54 0.09
PISO1 -0.18 1.72 1.07 0.04
Cimentación -2.00 0.00 0.00 0.00
C23 PISO2 2.83 7.62 5.12 0.06
PISO1 -0.18 1.72 1.18 0.03
Cimentación -2.00 0.00 0.00 0.00
C24 PISO2 2.83 7.62 6.61 0.15
PISO1 -0.18 1.72 1.49 0.07
Cimentación -2.00 0.00 0.00 0.00
C25 PISO2 2.83 7.62 8.05 0.07
PISO1 -0.18 1.72 1.80 0.04
Cimentación -2.00 0.00 0.00 0.00
C26 PISO2 2.80 4.14 5.12 0.05
PISO1 -0.18 0.96 1.18 0.03
Cimentación -2.00 0.00 0.00 0.00
8.2.DISTORSION DE COLUMNAS
h: Altura del nivel respecto al inmediato inferior
Distorsión:
Absoluta: Diferencia entre los desplazamientos de un nivel y los del inmediatamente inferior
Relativa: Relación entre la altura y la distorsión absoluta
Origen:
G: Sólo gravitatorias
GV: Gravitatorias + viento
Nota:
Las diferentes normas suelen limitar el valor de la distorsión relativa entre plantas y de la distorsión total (desplome) del edificio.
El valor absoluto se utilizará para definir las juntas sísmicas. El valor relativo suele limitarse en función de la altura de la planta 'h'. Secomprueba el valor 'Total' tomando en ese caso como valor de 'h' la altura total.
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
C1 PISO2 2.83 3.00 0.0004 h / 7500 GV 0.0003 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GVCimentación -2.00
Total 4.83 0.0005 h / 9650 GV 0.0003 ---- GV
C2 CUBIERTA 4.20 0.20 0.0001 h / 2000 GV 0.0000 ---- GV
PISO2 4.00 1.17 0.0004 h / 2938 GV 0.0001 ---- GV
2.83 3.00 0.0004 h / 7500 GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 33/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
33
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
Total 6.20 0.0009 h / 6889 GV 0.0002 ---- GV
C3 PISO2 2.83 3.00 0.0004 h / 7500 GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.83 0.0005 h / 9650 GV 0.0003 ---- GV
C4 PISO2 2.83 3.00 0.0004 h / 7500 GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0005 h / 9650 GV 0.0005 h / 9650 GV
C5 PISO2 2.83 3.00 0.0003 ---- GV 0.0003 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0003 ---- GV 0.0003 ---- GV
C6 CUBIERTA 4.20 0.20 0.0001 h / 2000 GV 0.0000 ---- GV
PISO2 4.00 1.17 0.0003 h / 3917 GV 0.0001 ---- GV
2.83 3.00 0.0003 ---- GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 6.20 0.0007 h / 8858 GV 0.0003 ---- GV
C7 PISO2 2.80 2.97 0.0003 h / 9917 GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.80 0.0003 ---- GV 0.0003 ---- GV
C8 PISO2 2.83 3.00 0.0003 ---- GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0003 ---- GV 0.0005 h / 9650 GV
C9 PISO2 2.83 3.00 0.0002 ---- GV 0.0003 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0003 ---- GV 0.0003 ---- GV
C10 PISO2 2.83 3.00 0.0002 ---- GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00Total 4.83 0.0003 ---- GV 0.0002 ---- GV
C11 PISO2 2.83 3.00 0.0003 ---- GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0004 ---- GV 0.0004 ---- GV
C12 CUBIERTA 4.20 0.20 0.0000 ---- GV 0.0000 ---- GV
PISO2 4.00 1.20 0.0001 ---- GV 0.0001 ---- GV
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 34/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 34
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
2.80 2.97 0.0003 h / 9917 GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 6.20 0.0005 ---- GV 0.0004 ---- GV
C13 PISO2 2.80 2.97 0.0003 h / 9917 GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.80 0.0004 ---- GV 0.0003 ---- GV
C14 PISO2 2.83 3.00 0.0003 ---- GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0004 ---- GV 0.0005 h / 9650 GV
C15 PISO2 2.83 3.00 0.0003 ---- GV 0.0006 h / 5000 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0004 ---- GV 0.0007 h / 6893 GV
C16 PISO2 2.83 3.00 0.0006 h / 5000 GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0007 h / 6893 GV 0.0004 ---- GV
C17 CUBIERTA 4.20 0.20 0.0000 ---- GV 0.0000 ---- GV
PISO2 4.00 1.20 0.0002 h / 6000 GV 0.0001 ---- GV
2.80 2.97 0.0006 h / 4959 GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 6.20 0.0008 h / 7750 GV 0.0002 ---- GV
C18 PISO2 2.80 2.97 0.0006 h / 4959 GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.80 0.0007 h / 6858 GV 0.0003 ---- GV
C19 PISO2 2.80 2.97 0.0006 h / 4959 GV 0.0004 h / 7438 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.80 0.0007 h / 6858 GV 0.0005 h / 9600 GVC20 PISO2 2.80 2.97 0.0006 h / 4959 GV 0.0006 h / 4959 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.80 0.0007 h / 6858 GV 0.0007 h / 6858 GV
C21 PISO2 2.83 3.00 0.0008 h / 3750 GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 35/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
35
Situaciones persistentes o transitorias
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
Total 4.83 0.0009 h / 5362 GV 0.0004 ---- GV
C22 CUBIERTA 4.20 0.20 0.0000 ---- GV 0.0001 h / 2000 GV
PISO2 4.00 1.17 0.0001 ---- GV 0.0003 h / 3917 GV
2.83 3.00 0.0008 h / 3750 GV 0.0001 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 6.20 0.0010 h / 6200 GV 0.0005 ---- GV
C23 PISO2 2.83 3.00 0.0008 h / 3750 GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.83 0.0009 h / 5362 GV 0.0003 ---- GV
C24 PISO2 2.83 3.00 0.0008 h / 3750 GV 0.0004 h / 7500 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0009 h / 5362 GV 0.0005 h / 9650 GV
C25 PISO2 2.83 3.00 0.0008 h / 3750 GV 0.0006 h / 5000 GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0001 ---- GV
Cimentación -2.00
Total 4.83 0.0009 h / 5362 GV 0.0007 h / 6893 GV
C26 PISO2 2.80 2.97 0.0002 ---- GV 0.0002 ---- GV
PISO1 -0.18 1.83 0.0001 ---- GV 0.0000 ---- GV
Cimentación -2.00
Total 4.80 0.0003 ---- GV 0.0003 ---- GV
Situaciones sísmicas
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
C1 PISO2 2.83 3.00 0.0027 h / 1112 ---- 0.0033 h / 910 ----
PISO1 -0.18 1.83 0.0008 h / 2282 ---- 0.0010 h / 1825 ----
Cimentación -2.00
Total 4.83 0.0034 h / 1420 ---- 0.0043 h / 1123 ----
C2 CUBIERTA 4.20 0.20 0.0001 h / 2000 ---- 0.0002 h / 1000 ----
PISO2 4.00 1.17 0.0005 h / 2350 ---- 0.0008 h / 1469 ----
2.83 3.00 0.0027 h / 1112 ---- 0.0036 h / 834 ----
PISO1 -0.18 1.83 0.0008 h / 2282 ---- 0.0011 h / 1660 ----
Cimentación -2.00
Total 6.20 0.0041 h / 1513 ---- 0.0056 h / 1108 ----
C3 PISO2 2.83 3.00 0.0027 h / 1112 ---- 0.0039 h / 770 ----
PISO1 -0.18 1.83 0.0008 h / 2282 ---- 0.0012 h / 1521 ----
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 36/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 36
Situaciones sísmicas
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
Cimentación -2.00
Total 4.83 0.0034 h / 1420 ---- 0.0051 h / 947 ----
C4 PISO2 2.83 3.00 0.0027 h / 1112 ---- 0.0051 h / 589 ----
PISO1 -0.18 1.83 0.0008 h / 2282 ---- 0.0015 h / 1217 ----
Cimentación -2.00
Total 4.83 0.0034 h / 1420 ---- 0.0066 h / 732 ----
C5 PISO2 2.83 3.00 0.0029 h / 1035 ---- 0.0033 h / 910 ----
PISO1 -0.18 1.83 0.0009 h / 2028 ---- 0.0010 h / 1825 ----
Cimentación -2.00
Total 4.83 0.0037 h / 1305 ---- 0.0043 h / 1123 ----
C6 CUBIERTA 4.20 0.20 0.0001 h / 2000 ---- 0.0002 h / 1000 ----
PISO2 4.00 1.17 0.0005 h / 2350 ---- 0.0008 h / 1469 ----
2.83 3.00 0.0029 h / 1035 ---- 0.0036 h / 834 ----
PISO1 -0.18 1.83 0.0009 h / 2028 ---- 0.0011 h / 1660 ----
Cimentación -2.00
Total 6.20 0.0043 h / 1442 ---- 0.0056 h / 1108 ----
C7 PISO2 2.80 2.97 0.0029 h / 1026 ---- 0.0039 h / 763 ----
PISO1 -0.18 1.83 0.0009 h / 2028 ---- 0.0012 h / 1521 ----
Cimentación -2.00
Total 4.80 0.0037 h / 1298 ---- 0.0051 h / 942 ----
C8 PISO2 2.83 3.00 0.0029 h / 1035 ---- 0.0051 h / 589 ----
PISO1 -0.18 1.83 0.0009 h / 2028 ---- 0.0015 h / 1217 ----
Cimentación -2.00
Total 4.83 0.0037 h / 1305 ---- 0.0066 h / 732 ----
C9 PISO2 2.83 3.00 0.0032 h / 938 ---- 0.0033 h / 910 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0010 h / 1825 ----
Cimentación -2.00
Total 4.83 0.0041 h / 1177 ---- 0.0043 h / 1123 ----
C10 PISO2 2.83 3.00 0.0032 h / 938 ---- 0.0036 h / 834 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0011 h / 1660 ----
Cimentación -2.00
Total 4.83 0.0041 h / 1177 ---- 0.0047 h / 1027 ----
C11 PISO2 2.83 3.00 0.0035 h / 858 ---- 0.0032 h / 938 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0009 h / 2028 ----Cimentación -2.00
Total 4.83 0.0045 h / 1073 ---- 0.0041 h / 1177 ----
C12 CUBIERTA 4.20 0.20 0.0001 h / 2000 ---- 0.0002 h / 1000 ----
PISO2 4.00 1.20 0.0003 h / 4000 ---- 0.0008 h / 1500 ----
2.80 2.97 0.0035 h / 850 ---- 0.0035 h / 850 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0011 h / 1660 ----
Cimentación -2.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 37/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
37
Situaciones sísmicas
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
Total 6.20 0.0049 h / 1266 ---- 0.0055 h / 1128 ----
C13 PISO2 2.80 2.97 0.0035 h / 850 ---- 0.0039 h / 763 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0012 h / 1521 ----
Cimentación -2.00
Total 4.80 0.0045 h / 1067 ---- 0.0051 h / 942 ----
C14 PISO2 2.83 3.00 0.0035 h / 858 ---- 0.0051 h / 589 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0015 h / 1217 ----
Cimentación -2.00
Total 4.83 0.0045 h / 1073 ---- 0.0066 h / 732 ----
C15 PISO2 2.83 3.00 0.0035 h / 858 ---- 0.0063 h / 477 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0018 h / 1014 ----
Cimentación -2.00
Total 4.83 0.0045 h / 1073 ---- 0.0080 h / 604 ----
C16 PISO2 2.83 3.00 0.0048 h / 625 ---- 0.0032 h / 938 ----
PISO1 -0.18 1.83 0.0014 h / 1304 ---- 0.0009 h / 2028 ----
Cimentación -2.00
Total 4.83 0.0062 h / 779 ---- 0.0041 h / 1177 ----
C17 CUBIERTA 4.20 0.20 0.0001 h / 2000 ---- 0.0002 h / 1000 ----
PISO2 4.00 1.20 0.0005 h / 2400 ---- 0.0008 h / 1500 ----
2.80 2.97 0.0048 h / 620 ---- 0.0035 h / 850 ----
PISO1 -0.18 1.83 0.0014 h / 1304 ---- 0.0011 h / 1660 ----
Cimentación -2.00
Total 6.20 0.0068 h / 912 ---- 0.0054 h / 1149 ----
C18 PISO2 2.80 2.97 0.0048 h / 620 ---- 0.0039 h / 763 ----
PISO1 -0.18 1.83 0.0014 h / 1304 ---- 0.0012 h / 1521 ----
Cimentación -2.00
Total 4.80 0.0062 h / 775 ---- 0.0051 h / 942 ----
C19 PISO2 2.80 2.97 0.0048 h / 620 ---- 0.0051 h / 584 ----
PISO1 -0.18 1.83 0.0014 h / 1304 ---- 0.0015 h / 1217 ----
Cimentación -2.00
Total 4.80 0.0062 h / 775 ---- 0.0066 h / 728 ----
C20 PISO2 2.80 2.97 0.0048 h / 620 ---- 0.0063 h / 473 ----
PISO1 -0.18 1.83 0.0014 h / 1304 ---- 0.0018 h / 1014 ----
Cimentación -2.00Total 4.80 0.0062 h / 775 ---- 0.0080 h / 600 ----
C21 PISO2 2.83 3.00 0.0059 h / 509 ---- 0.0032 h / 938 ----
PISO1 -0.18 1.83 0.0017 h / 1074 ---- 0.0009 h / 2028 ----
Cimentación -2.00
Total 4.83 0.0076 h / 635 ---- 0.0041 h / 1177 ----
C22 CUBIERTA 4.20 0.20 0.0001 h / 2000 ---- 0.0002 h / 1000 ----
PISO2 4.00 1.17 0.0005 h / 2350 ---- 0.0011 h / 1069 ----
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 38/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 38
Situaciones sísmicas
Pilar PlantaCota
(m)
h
(m)
Distorsión X Distorsión Y
Absoluta
(m)Relativa Origen
Absoluta
(m)Relativa Origen
2.83 3.00 0.0059 h / 509 ---- 0.0035 h / 858 ----
PISO1 -0.18 1.83 0.0017 h / 1074 ---- 0.0011 h / 1660 ----
Cimentación -2.00
Total 6.20 0.0082 h / 757 ---- 0.0057 h / 1088 ----
C23 PISO2 2.83 3.00 0.0059 h / 509 ---- 0.0039 h / 770 ----
PISO1 -0.18 1.83 0.0017 h / 1074 ---- 0.0012 h / 1521 ----
Cimentación -2.00
Total 4.83 0.0076 h / 635 ---- 0.0051 h / 947 ----
C24 PISO2 2.83 3.00 0.0059 h / 509 ---- 0.0051 h / 589 ----
PISO1 -0.18 1.83 0.0017 h / 1074 ---- 0.0015 h / 1217 ----
Cimentación -2.00
Total 4.83 0.0076 h / 635 ---- 0.0066 h / 732 ----
C25 PISO2 2.83 3.00 0.0059 h / 509 ---- 0.0063 h / 477 ----
PISO1 -0.18 1.83 0.0017 h / 1074 ---- 0.0018 h / 1014 ----
Cimentación -2.00
Total 4.83 0.0076 h / 635 ---- 0.0080 h / 604 ----
C26 PISO2 2.80 2.97 0.0032 h / 930 ---- 0.0039 h / 763 ----
PISO1 -0.18 1.83 0.0010 h / 1825 ---- 0.0012 h / 1521 ----
Cimentación -2.00
Total 4.80 0.0041 h / 1171 ---- 0.0051 h / 942 ----
Valores máximos
Desplome local máximo de los pilares ( / h)
PlantaSituaciones persistentes o transitorias Situaciones sísmicas
Dirección X Dirección Y Dirección X Dirección Y
CUBIERTA 1 / 2000 1 / 2000 1 / 2000 1 / 1000
PISO2 1 / 2938 1 / 3917 1 / 509 1 / 473
PISO1 ---- ---- 1 / 1074 1 / 1014
Desplome total máximo de los pilares (
/ H)
Situaciones persistentes o transitorias Situaciones sísmicas
Dirección X Dirección Y Dirección X Dirección Y
1 / 5362 1 / 6858 1 / 635 1 / 600
8.3. ESFUERZOS Y ARMADO DE COLUMNAS Y MURO
1.- MATERIALES
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 39/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
39
1.1.- Hormigones
Elemento Hormigónf ck
(kp/cm²)c
Tamaño máximo del árido(mm)
Todos f'c=210 210 1.00 15
1.2.- Aceros por elemento y posición
1.2.1.- Aceros en barras
Elemento Acerof yk
(kp/cm²)s
Todos Grado 60 (Latinoamérica) 4200 1.00
1.2.2.- Aceros en perfiles
Tipo de acero para perfiles AceroLímite elástico
(kp/cm²)Módulo de elasticidad
(kp/cm²)
Acero conformado A-36 2548 2089704
Acero laminado ASTM A 36 36 ksi 2548 2038736
2.- ARMADO DE PILARES Y PANTALLAS
2.1.- Pilares
Armado de pilares
Hormigón: f'c=210
Pilar
Geometría ArmadurasAprov.(%)
EstadoPlanta
Dimensiones(cm)
Tramo(m)
Barras Estribos
Esquina Cara X Cara YCuantía
(%)Perimetral Dir. X(1) Dir. Y(1)
Separación(cm)
C1 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 55.9 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 45.5 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 35.0 Cumple
C2 CUBIERTA 35x35 4.00/4.205 72.9 Cumple
PISO2 35x353.00/4.00 4Ø1/2" 2Ø1/2" 4Ø1/2" 1.03 1eØ1/2" 2rØ1/2" 1rØ1/2"
0.00/2.65 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 91.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 53.6 Cumple
Cimentación - - 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" - - - 39.0 Cumple
C3 PISO2 35x35 0.00/2.65 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 82.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 69.5 Cumple
Cimentación - - 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" - - - 46.0 Cumple
C4 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 88.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 63.7 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 46.8 Cumple
C5 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 51.5 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 40/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 40
Armado de pilares
Hormigón: f'c=210
Pilar
Geometría Armaduras
Aprov.(%)
EstadoPlanta
Dimensiones(cm)
Tramo(m)
Barras Estribos
Esquina Cara X Cara YCuantía
(%)Perimetral Dir. X(1) Dir. Y(1)
Separación(cm)
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 62.5 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 37.8 Cumple
C6 CUBIERTA 35x35 4.00/4.206 67.4 Cumple
PISO2 35x353.00/4.00 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2"
0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 98.0 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 69.7 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 45.6 Cumple
C7 PISO2 35x35 0.00/2.60 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 66.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 74.3 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 50.1 Cumple
C8 PISO2 35x35 0.00/2.65 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 79.1 Cumple
PISO1 35x35 -2.00/-0.35 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 59.7 Cumple
Cimentación - - 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" - - - 42.4 Cumple
C9 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 52.1 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 53.3 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 34.9 Cumple
C10 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 59.0 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 77.2 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 42.3 Cumple
C11 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 58.0 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 47.0 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 39.6 Cumple
C12 CUBIERTA 35x35 4.00/4.20 5 50.9 Cumple
PISO2 35x353.00/4.00 4Ø1/2" 2Ø1/2" 4Ø1/2" 1.03 1eØ1/2" 2rØ1/2" 1rØ1/2"
0.00/2.60 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 83.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 52.2 Cumple
Cimentación - - 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" - - - 36.5 Cumple
C13 PISO2 35x35 0.00/2.60 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 62.9 Cumple
PISO1 35x35 -2.00/-0.35 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 79.8 Cumple
Cimentación - - 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" - - - 44.4 Cumple
C14 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 56.3 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 50.1 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 48.8 Cumple
C15 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 98.4 CumplePISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 74.0 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 67.3 Cumple
C16 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 52.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 54.0 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 44.2 Cumple
C17 CUBIERTA 35x35 4.00/4.205 70.1 Cumple
PISO2 35x35 3.00/4.00 4Ø1/2" 2Ø1/2" 4Ø1/2" 1.03 1eØ1/2" 2rØ1/2" 1rØ1/2"
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 41/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
41
Armado de pilares
Hormigón: f'c=210
Pilar
Geometría Armaduras
Aprov.(%)
EstadoPlanta
Dimensiones(cm)
Tramo(m)
Barras Estribos
Esquina Cara X Cara YCuantía
(%)Perimetral Dir. X(1) Dir. Y(1)
Separación(cm)
0.00/2.60 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 99.5 Cumple
PISO1 35x35 -2.00/-0.35 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 67.6 Cumple
Cimentación - - 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" - - - 43.2 Cumple
C18 PISO2 35x35 0.00/2.60 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 80.2 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 97.8 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 54.5 Cumple
C19 PISO2 35x35 0.00/2.60 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 78.1 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 73.8 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 58.9 Cumple
C20 PISO2 35x35 0.00/2.60 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 86.5 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 93.3 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 64.6 Cumple
C21 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 62.8 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 66.3 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 47.4 Cumple
C22 CUBIERTA 35x35 4.00/4.205 72.2 Cumple
PISO2 35x353.00/4.00 4Ø1/2" 2Ø1/2" 4Ø1/2" 1.03 1eØ1/2" 2rØ1/2" 1rØ1/2"
0.00/2.65 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 80.7 Cumple
PISO1 35x35 -2.00/-0.35 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 84.4 Cumple
Cimentación - - 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" - - - 48.7 Cumple
C23 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 90.4 Cumple
PISO1 35x35 -2.00/-0.35 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 92.0 Cumple
Cimentación - - 4Ø3/4" 2Ø5/8" 2Ø5/8" 1.58 1eØ3/8" - - - 56.2 CumpleC24 PISO2 35x35 0.00/2.65 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 78.2 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 94.3 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 64.9 Cumple
C25 PISO2 35x35 0.00/2.65 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 98.7 Cumple
PISO1 35x35 -2.00/-0.35 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" 1rØ3/8" 1rØ3/8" 8 90.1 Cumple
Cimentación - - 4Ø5/8" 2Ø5/8" 2Ø5/8" 1.30 1eØ3/8" - - - 65.3 Cumple
C26 PISO2 35x35 0.00/2.60 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 59.8 Cumple
PISO1 35x35 -2.00/-0.35 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" 6 89.4 Cumple
Cimentación - - 4Ø1/2" 4Ø1/2" 4Ø1/2" 1.24 1eØ1/2" 2rØ1/2" 2rØ1/2" - 49.5 Cumple
Notas:(1) e = estribo, r = rama
3.- ESFUERZOS DE PILARES, PANTALLAS Y MUROS POR HIPÓTESIS
Tramo: Nivel inicial / nivel final del tramo entre plantas.
Nota:
Los esfuerzos están referidos a ejes locales del pilar.
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 42/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 42
Soporte PlantaDimensión
(cm)Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C1 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de uso
Viento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
2.870.710.41
-0.05-0.060.050.06
-0.03-0.020.030.02
-0.59-0.68-0.89-0.81
0.600.350.21
-0.07-0.120.070.12
-0.020.000.02
-0.00-0.85-1.45-1.12-0.57
0.140.020.01
-0.020.010.02
-0.01-0.06-0.070.060.07
-0.64-0.24-1.62-1.98
0.490.260.15
-0.04-0.070.040.07
-0.010.000.01
-0.00-0.49-0.85-0.66-0.34
0.110.020.01
-0.010.010.01
-0.01-0.03-0.040.030.04
-0.37-0.14-0.95-1.16
0.000.000.00
0.00-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
2.060.710.41
-0.05-0.060.050.06
-0.03-0.020.030.02
-0.59-0.68-0.89-0.81
-0.71-0.33-0.19
0.040.07-0.04-0.070.01
-0.00-0.010.000.460.800.620.32
-0.16-0.04-0.02
0.01-0.00-0.010.000.030.04
-0.03-0.040.350.140.901.09
0.490.260.15
-0.04-0.070.040.07
-0.010.000.01
-0.00-0.49-0.85-0.66-0.34
0.110.020.01
-0.010.010.01
-0.01-0.03-0.040.030.04
-0.37-0.14-0.95-1.16
0.000.000.00
0.00-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+
Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.681.120.68
-0.08-0.090.08
0.09-0.06-0.060.060.06
-1.29-1.33-2.14-2.10
0.09-0.01-0.00-0.07-0.110.07
0.11-0.020.000.02
-0.00-0.87-1.50-1.14-0.57
0.070.030.02
-0.030.010.03
-0.01-0.06-0.080.060.08
-0.91-0.45-1.74-2.16
0.14-0.04-0.01-0.03-0.050.03
0.05-0.010.000.01
-0.00-0.43-0.73-0.56-0.28
0.140.060.04
-0.020.000.02
-0.00-0.03-0.050.030.05
-0.61-0.32-1.06-1.33
0.000.000.000.00
-0.00-0.00
0.00-0.000.000.00
-0.000.010.00
-0.01-0.00
4.181.120.68
-0.08-0.090.08
0.09-0.06-0.060.060.06
-1.29-1.33-2.14-2.10
-0.130.050.01
-0.02-0.030.02
0.03-0.000.000.00
-0.00-0.16-0.29-0.22-0.10
-0.17-0.07-0.050.000.00
-0.00
-0.00-0.00-0.000.000.000.100.080.010.03
0.14-0.04-0.01-0.03-0.050.03
0.05-0.010.000.01
-0.00-0.43-0.73-0.56-0.28
0.140.060.04
-0.020.000.02
-0.00-0.03-0.050.030.05
-0.61-0.32-1.06-1.33
0.000.000.000.00
-0.00-0.00
0.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C2 CUBIERTA 35x35 4.00/4.20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.06-0.000.000.000.000.00
-0.000.000.00
-0.00-0.00-0.000.000.00
-0.00
-0.00-0.00-0.00-0.02-0.020.020.020.000.00
-0.00-0.00-0.00-0.00-0.00-0.00
0.00-0.00-0.000.000.00
-0.00-0.00-0.01-0.010.010.01
-0.00-0.00-0.00-0.00
0.00-0.00-0.00-0.10-0.100.100.100.000.00
-0.00-0.00-0.01-0.01-0.00-0.00
0.00-0.00-0.000.000.00
-0.00-0.00-0.06-0.060.060.06
-0.00-0.00-0.01-0.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
-0.00-0.000.000.000.000.00
-0.000.000.00
-0.00-0.00-0.000.000.00
-0.00
-0.00-0.000.000.000.00
-0.00-0.000.00
-0.00-0.000.00
-0.00-0.000.000.00
-0.00-0.000.00
-0.00-0.000.000.00
-0.00-0.000.000.000.000.00
-0.00-0.00
0.00-0.00-0.00-0.10-0.100.100.100.000.00
-0.00-0.00-0.01-0.01-0.00-0.00
0.00-0.00-0.000.000.00
-0.00-0.00-0.06-0.060.060.06
-0.00-0.00-0.01-0.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
PISO2 35x35 3.00/4.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-
Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
1.07-0.08-0.050.020.03
-0.02-0.030.00
-0.00-0.000.00
0.130.200.120.05
-0.28-0.50-0.28-0.010.020.01
-0.020.01
-0.00-0.010.00
0.550.940.680.32
-0.16-0.23-0.130.000.00
-0.00-0.00-0.06-0.060.060.06
0.120.070.090.14
-1.05-0.50-0.290.000.03
-0.00-0.030.01
-0.00-0.010.00
0.520.900.660.31
-0.13-0.23-0.130.000.00
-0.00-0.00-0.06-0.050.060.05
0.250.14-0.090.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.00
0.450.19-0.76-0.56
0.76-0.08-0.050.020.03
-0.02-0.030.00
-0.00-0.000.00
0.130.200.120.05
0.770.000.00
-0.02-0.020.020.020.00
-0.00-0.000.00
0.030.040.030.01
-0.020.000.00
-0.00-0.000.000.00
-0.01-0.010.010.01
-0.13-0.070.180.13
-1.05-0.50-0.290.000.03
-0.00-0.030.01
-0.00-0.010.00
0.520.900.660.31
-0.13-0.23-0.130.000.00
-0.00-0.00-0.06-0.050.060.05
0.250.14-0.090.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.00
0.450.19-0.76-0.56
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 43/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
43
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.231.200.69
-0.04-0.06
0.040.06-0.07-0.060.070.06
-0.49-0.80-2.07-1.79
-0.51-0.13-0.08-0.13-0.23
0.130.23-0.040.010.04
-0.01-1.79-3.06-2.34-1.18
0.08-0.01-0.00-0.010.00
0.01-0.00-0.07-0.070.070.07
-0.15-0.04-2.66-2.76
-0.53-0.22-0.13-0.10-0.17
0.100.17-0.030.010.03
-0.01-1.38-2.36-1.80-0.91
0.03-0.05-0.03-0.010.00
0.01-0.00-0.04-0.050.040.05
-0.14-0.05-1.98-2.06
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
3.421.200.69
-0.04-0.06
0.040.06-0.07-0.060.070.06
-0.49-0.80-2.07-1.79
0.890.460.260.130.23
-0.13-0.230.04
-0.01-0.040.011.873.192.441.23
0.010.130.070.01
-0.00
-0.010.000.050.05
-0.05-0.050.210.092.582.70
-0.53-0.22-0.13-0.10-0.17
0.100.17-0.030.010.03
-0.01-1.38-2.36-1.80-0.91
0.03-0.05-0.03-0.010.00
0.01-0.00-0.04-0.050.040.05
-0.14-0.05-1.98-2.06
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.351.841.10
-0.14-0.230.140.23
-0.14
-0.090.140.09
-1.86-3.03-5.02-3.97
-0.010.040.01
-0.10-0.170.100.17
-0.03
0.000.03
-0.00-1.25-2.15-1.64-0.82
0.120.070.04
-0.010.000.01
-0.00-0.07
-0.070.070.07
-0.20-0.11-2.25-2.33
-0.030.040.02
-0.09-0.140.090.14
-0.03
0.000.03
-0.00-1.05-1.81-1.37-0.68
0.210.110.07
-0.00-0.000.000.00
-0.04
-0.040.040.04
-0.14-0.10-1.24-1.28
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
5.841.841.10
-0.14-0.230.140.23
-0.14
-0.090.140.09
-1.86-3.03-5.02-3.97
0.04-0.04-0.010.040.07
-0.04-0.070.01
-0.00-0.010.000.490.840.630.31
-0.23-0.11-0.070.000.00
-0.00-0.00-0.00
-0.000.000.000.030.05
-0.21-0.23
-0.030.040.02
-0.09-0.140.090.14
-0.03
0.000.03
-0.00-1.05-1.81-1.37-0.68
0.210.110.07
-0.00-0.000.000.00
-0.04
-0.040.040.04
-0.14-0.10-1.24-1.28
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C3 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.946.523.730.070.10
-0.07-0.10-0.01-0.030.010.030.701.150.05
-0.36
0.540.650.38
-0.12-0.190.120.19
-0.030.010.03
-0.01-1.41-2.42-1.85-0.94
0.390.440.250.000.00
-0.00-0.00-0.07-0.070.070.070.180.14
-2.47-2.43
0.450.540.31
-0.07-0.110.070.11
-0.020.000.02
-0.00-0.84-1.43-1.10-0.56
0.330.390.220.000.00
-0.00-0.00-0.04-0.040.040.040.100.07
-1.46-1.43
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
6.136.523.730.070.10
-0.07-0.10-0.01-0.030.010.030.701.150.05
-0.36
-0.66-0.78-0.450.070.11
-0.07-0.110.02
-0.00-0.020.000.811.381.060.54
-0.48-0.59-0.34-0.000.000.00
-0.000.040.04
-0.04-0.04-0.09-0.061.391.37
0.450.540.31
-0.07-0.110.070.11
-0.020.000.02
-0.00-0.84-1.43-1.10-0.56
0.330.390.220.000.00
-0.00-0.00-0.04-0.040.040.040.100.07
-1.46-1.43
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
9.056.924.000.170.27
-0.17-0.27-0.02-0.070.020.072.073.44
0.38-0.86
0.08-0.08-0.04-0.11-0.180.110.18
-0.030.000.03
-0.00-1.36-2.33
-1.77-0.89
0.01-0.10-0.050.000.00
-0.00-0.00-0.07-0.070.070.070.080.05
-2.63-2.60
0.12-0.15-0.08-0.10-0.160.100.16
-0.030.000.03
-0.00-1.23-2.11
-1.60-0.80
0.01-0.17-0.090.000.00
-0.00-0.00-0.04-0.040.040.040.030.02
-1.59-1.58
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
8.546.924.000.170.27
-0.17-0.27-0.02-0.070.020.072.073.44
0.38-0.86
-0.110.170.080.050.09
-0.05-0.090.02
-0.00-0.020.000.671.15
0.870.43
-0.020.180.10
-0.00-0.000.000.00
-0.00-0.000.000.000.030.01
-0.010.01
0.12-0.15-0.08-0.10-0.160.100.16
-0.030.000.03
-0.00-1.23-2.11
-1.60-0.80
0.01-0.17-0.090.000.00
-0.00-0.00-0.04-0.040.040.040.030.02
-1.59-1.58
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 44/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 44
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C4 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.483.471.980.020.02
-0.02-0.02-0.03-0.030.030.030.440.41
-0.96-0.93
-1.00-0.88-0.51-0.07-0.11
0.070.11-0.020.000.02
-0.00-0.81-1.38-1.04-0.52
0.410.430.250.02
-0.01
-0.020.01-0.09-0.070.090.070.820.41
-3.22-2.85
-0.88-0.89-0.51-0.04-0.06
0.040.06-0.010.000.01
-0.00-0.46-0.79-0.59-0.30
0.320.340.200.01
-0.01
-0.010.01-0.05-0.040.050.040.480.24
-1.91-1.69
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
3.663.471.980.020.02
-0.02-0.02-0.03-0.030.030.030.440.41
-0.96-0.93
1.351.490.850.030.06
-0.03-0.060.01
-0.00-0.010.000.420.720.540.27
-0.43-0.48-0.27-0.010.01
0.01-0.010.050.04
-0.05-0.04-0.46-0.231.841.63
-0.88-0.89-0.51-0.04-0.06
0.040.06-0.010.000.01
-0.00-0.46-0.79-0.59-0.30
0.320.340.200.01
-0.01
-0.010.01-0.05-0.040.050.040.480.24
-1.91-1.69
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.383.942.290.050.04
-0.05-0.04-0.07
-0.070.070.071.141.04
-2.53-2.44
0.060.240.13
-0.07-0.110.070.11
-0.02
0.000.02
-0.00-0.86-1.48-1.12-0.55
0.03-0.07-0.040.02
-0.01-0.020.01
-0.09
-0.070.090.070.800.39
-3.35-2.98
0.090.380.20
-0.03-0.050.030.05
-0.01
0.000.01
-0.00-0.41-0.71-0.52-0.25
0.04-0.14-0.070.02
-0.00-0.020.00
-0.05
-0.040.050.040.490.23
-2.09-1.85
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
5.873.942.290.050.04
-0.05-0.04-0.07
-0.070.070.071.141.04
-2.53-2.44
-0.08-0.39-0.21-0.02-0.030.020.03
-0.00
0.000.00
-0.00-0.18-0.31-0.26-0.14
-0.030.160.08
-0.00-0.000.000.000.00
0.00-0.00-0.00-0.000.010.090.08
0.090.380.20
-0.03-0.050.030.05
-0.01
0.000.01
-0.00-0.41-0.71-0.52-0.25
0.04-0.14-0.070.02
-0.00-0.020.00
-0.05
-0.040.050.040.490.23
-2.09-1.85
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C5 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.480.840.48
-0.04-0.060.040.06
-0.000.010.00
-0.01-0.47-0.64-0.140.01
0.570.250.15
-0.08-0.110.080.11
-0.010.000.01
-0.00-1.22-1.61-0.71-0.36
-0.13-0.08-0.05-0.030.010.03
-0.01-0.08-0.100.080.10
-0.92-0.37-2.18-2.68
0.490.190.11
-0.05-0.060.050.06
-0.010.000.01
-0.00-0.71-0.94-0.41-0.21
-0.09-0.05-0.03-0.020.010.02
-0.01-0.05-0.060.050.06
-0.55-0.22-1.29-1.59
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
2.670.840.48
-0.04-0.060.040.06
-0.000.010.00
-0.01-0.47-0.64-0.140.01
-0.71-0.24-0.140.050.06
-0.05-0.060.01
-0.00-0.010.000.670.880.390.19
0.120.050.030.02
-0.01-0.020.010.040.06
-0.04-0.060.530.221.251.53
0.490.190.11
-0.05-0.060.050.06
-0.010.000.01
-0.00-0.71-0.94-0.41-0.21
-0.09-0.05-0.03-0.020.010.02
-0.01-0.05-0.060.050.06
-0.55-0.22-1.29-1.59
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
5.851.440.88
-0.07-0.090.070.09
-0.000.010.00
-0.01-0.86-1.18
-0.31-0.03
0.090.010.02
-0.08-0.110.080.11
-0.010.000.01
-0.00-1.34-1.72
-0.71-0.35
-0.02-0.01-0.00-0.030.010.03
-0.01-0.07-0.100.070.10
-1.13-0.55
-2.22-2.75
0.150.020.02
-0.04-0.050.040.05
-0.010.000.01
-0.00-0.67-0.86
-0.34-0.17
-0.010.000.00
-0.030.010.03
-0.01-0.06-0.080.060.08
-0.98-0.49
-1.85-2.29
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
5.351.440.88
-0.07-0.090.070.09
-0.000.010.00
-0.01-0.86-1.18
-0.31-0.03
-0.16-0.02-0.02-0.02-0.020.020.02
-0.000.000.00
-0.00-0.22-0.30
-0.15-0.08
-0.01-0.01-0.010.01
-0.00-0.010.000.030.04
-0.03-0.040.480.26
0.831.04
0.150.020.02
-0.04-0.050.040.05
-0.010.000.01
-0.00-0.67-0.86
-0.34-0.17
-0.010.000.00
-0.030.010.03
-0.01-0.06-0.080.060.08
-0.98-0.49
-1.85-2.29
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 45/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
45
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C6 CUBIERTA 35x35 4.00/4.20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.06-0.00-0.000.000.00
0.000.00-0.000.000.00
-0.000.000.000.000.00
-0.00-0.00-0.00-0.02-0.02
0.020.02-0.00-0.000.000.00
-0.00-0.000.000.00
0.000.000.000.00
-0.00
-0.000.00-0.01-0.010.010.01
-0.00-0.00-0.00-0.00
-0.00-0.00-0.00-0.10-0.10
0.100.10-0.00-0.000.000.00
-0.01-0.010.000.00
0.000.000.000.00
-0.00
-0.000.00-0.06-0.060.060.06
-0.000.00
-0.01-0.01
-0.00-0.00-0.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.01
-0.01-0.010.01
-0.00-0.00-0.000.000.00
0.000.00-0.000.000.00
-0.000.000.000.000.00
0.000.000.000.00
-0.00
-0.000.000.000.00
-0.00-0.00-0.00-0.00-0.00-0.00
-0.00-0.00-0.00-0.000.00
0.00-0.000.00
-0.00-0.000.00
-0.00-0.000.000.00
-0.00-0.00-0.00-0.10-0.10
0.100.10-0.00-0.000.000.00
-0.01-0.010.000.00
0.000.000.000.00
-0.00
-0.000.00-0.06-0.060.060.06
-0.000.00
-0.01-0.01
-0.00-0.00-0.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.01
-0.01-0.010.01
PISO2 35x35 3.00/4.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
1.08-0.05-0.030.020.03
-0.02-0.030.00
0.00-0.00-0.000.180.230.100.06
-0.22-0.30-0.17-0.010.010.01
-0.010.01
-0.00-0.010.000.700.980.530.28
0.150.230.13
-0.00-0.000.000.00
-0.09
-0.090.090.090.190.13
-0.70-0.65
-1.01-0.30-0.170.010.03
-0.01-0.030.01
-0.00-0.010.000.650.930.520.27
0.130.230.13
-0.00-0.000.000.00
-0.08
-0.080.080.080.400.28
-0.88-0.78
0.00-0.00-0.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.810.55
-0.75-0.56
0.78-0.05-0.030.020.03
-0.02-0.030.00
0.00-0.00-0.000.180.230.100.06
0.790.000.00
-0.02-0.020.020.020.00
-0.00-0.000.000.040.050.010.01
0.020.000.00
-0.000.000.00
-0.00-0.01
-0.010.010.01
-0.21-0.160.190.13
-1.01-0.30-0.170.010.03
-0.01-0.030.01
-0.00-0.010.000.650.930.520.27
0.130.230.13
-0.00-0.000.000.00
-0.08
-0.080.080.080.400.28
-0.88-0.78
0.00-0.00-0.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.810.55
-0.75-0.56
0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.912.581.47
-0.05-0.070.050.070.020.03
-0.02-0.03-0.68-0.950.060.31
-0.57-0.11-0.07-0.16-0.220.160.22
-0.030.000.03
-0.00-2.65-3.46-1.51-0.77
0.110.170.10
-0.010.000.01
-0.00-0.10-0.110.100.11
-0.20-0.05-3.63-3.77
-0.56-0.15-0.09-0.12-0.170.120.17
-0.020.000.02
-0.00-2.05-2.68-1.17-0.60
0.130.190.11
-0.010.000.01
-0.00-0.07-0.080.070.08
-0.18-0.06-2.72-2.83
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
5.102.581.47
-0.05-0.070.050.070.020.03
-0.02-0.03-0.68-0.950.060.31
0.910.290.170.160.22
-0.16-0.220.03
-0.00-0.030.002.793.651.590.81
-0.24-0.32-0.180.01
-0.00-0.010.000.090.09
-0.09-0.090.270.103.583.74
-0.56-0.15-0.09-0.12-0.170.120.17
-0.020.000.02
-0.00-2.05-2.68-1.17-0.60
0.130.190.11
-0.010.000.01
-0.00-0.07-0.080.070.08
-0.18-0.06-2.72-2.83
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
8.573.361.99
-0.17-0.230.170.23
-0.000.030.00
-0.03-2.61-3.46
-1.00-0.23
-0.03-0.01-0.01-0.12-0.160.120.16
-0.020.000.02
-0.00-1.91-2.47
-1.02-0.51
-0.05-0.05-0.03-0.010.000.01
-0.00-0.09-0.090.090.09
-0.24-0.12
-2.90-3.01
-0.05-0.02-0.02-0.10-0.140.100.14
-0.020.000.02
-0.00-1.61-2.08
-0.85-0.43
-0.07-0.08-0.05-0.010.000.01
-0.00-0.07-0.080.070.08
-0.20-0.11
-2.30-2.40
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
8.063.361.99
-0.17-0.230.170.23
-0.000.030.00
-0.03-2.61-3.46
-1.00-0.23
0.060.020.020.050.07
-0.05-0.070.01
-0.00-0.010.000.760.97
0.390.19
0.070.090.050.00
-0.00-0.000.000.030.03
-0.03-0.030.100.06
0.900.94
-0.05-0.02-0.02-0.10-0.140.100.14
-0.020.000.02
-0.00-1.61-2.08
-0.85-0.43
-0.07-0.08-0.05-0.010.000.01
-0.00-0.07-0.080.070.08
-0.20-0.11
-2.30-2.40
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 46/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 46
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C7 PISO2 35x35 0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.665.713.260.080.10
-0.08-0.100.020.00
-0.02-0.001.021.330.770.49
0.370.390.23
-0.14-0.19
0.140.19-0.020.000.02
-0.00-2.15-2.80-1.21-0.61
-0.15-0.17-0.100.00
-0.00
-0.000.00-0.10-0.100.100.100.220.15
-3.43-3.36
0.310.320.18
-0.08-0.11
0.080.11-0.010.000.01
-0.00-1.29-1.68-0.73-0.37
-0.15-0.19-0.110.00
-0.00
-0.000.00-0.06-0.060.060.060.130.09
-2.07-2.03
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
5.865.713.260.080.10
-0.08-0.100.020.00
-0.02-0.001.021.330.770.49
-0.43-0.44-0.250.080.11
-0.08-0.110.01
-0.00-0.010.001.211.580.680.35
0.240.320.18
-0.000.00
0.00-0.000.060.06
-0.06-0.06-0.11-0.071.961.93
0.310.320.18
-0.08-0.11
0.080.11-0.010.000.01
-0.00-1.29-1.68-0.73-0.37
-0.15-0.19-0.110.00
-0.00
-0.000.00-0.06-0.060.060.060.130.09
-2.07-2.03
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.366.323.680.200.27
-0.20-0.270.04
0.01-0.04-0.013.003.912.061.23
0.10-0.03-0.01-0.13-0.170.130.17
-0.02
0.000.02
-0.00-2.05-2.65-1.09-0.54
0.030.070.040.00
-0.00-0.000.00
-0.09
-0.090.090.090.100.05
-3.29-3.25
0.16-0.05-0.02-0.11-0.150.110.15
-0.02
0.000.02
-0.00-1.85-2.39-0.98-0.48
0.060.100.060.00
-0.00-0.000.00
-0.08
-0.070.080.070.060.02
-2.68-2.64
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
8.866.323.680.200.27
-0.20-0.270.04
0.01-0.04-0.013.003.912.061.23
-0.160.060.020.060.08
-0.06-0.080.01
-0.00-0.010.001.001.290.510.25
-0.06-0.10-0.06-0.000.000.00
-0.000.03
0.03-0.03-0.03-0.010.011.131.12
0.16-0.05-0.02-0.11-0.150.110.15
-0.02
0.000.02
-0.00-1.85-2.39-0.98-0.48
0.060.100.060.00
-0.00-0.000.00
-0.08
-0.070.080.070.060.02
-2.68-2.64
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C8 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.292.111.210.010.02
-0.01-0.020.030.03
-0.03-0.03-0.070.151.291.09
-0.78-0.56-0.33-0.08-0.100.080.10
-0.010.000.01
-0.00-1.16-1.52-0.68-0.35
-0.29-0.17-0.100.02
-0.01-0.020.01
-0.09-0.070.090.070.820.41
-3.21-2.84
-0.65-0.55-0.32-0.04-0.060.040.06
-0.010.000.01
-0.00-0.67-0.87-0.38-0.20
-0.27-0.22-0.130.01
-0.01-0.010.01
-0.05-0.040.050.040.480.24
-1.90-1.68
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
2.482.111.210.010.02
-0.01-0.020.030.03
-0.03-0.03-0.070.151.291.09
0.950.900.520.040.05
-0.04-0.050.01
-0.00-0.010.000.600.780.340.17
0.430.400.23
-0.010.000.01
-0.000.050.04
-0.05-0.04-0.46-0.231.831.62
-0.65-0.55-0.32-0.04-0.060.040.06
-0.010.000.01
-0.00-0.67-0.87-0.38-0.20
-0.27-0.22-0.130.01
-0.01-0.010.01
-0.05-0.040.050.040.480.24
-1.90-1.68
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
5.172.531.490.020.06
-0.02-0.060.090.07
-0.09-0.07-0.170.39
3.362.86
-0.030.110.05
-0.08-0.110.080.11
-0.010.000.01
-0.00-1.32-1.71
-0.72-0.37
-0.040.040.020.02
-0.01-0.020.01
-0.09-0.070.090.070.800.38
-3.36-2.98
-0.060.170.08
-0.04-0.050.040.05
-0.01-0.000.010.00
-0.65-0.84
-0.36-0.19
-0.080.050.020.02
-0.00-0.020.00
-0.05-0.040.050.040.480.22
-2.10-1.86
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
4.662.531.490.020.06
-0.02-0.060.090.07
-0.09-0.07-0.170.39
3.362.86
0.07-0.17-0.08-0.02-0.020.020.02
-0.000.000.00
-0.00-0.25-0.33
-0.13-0.06
0.09-0.04-0.01-0.00-0.000.000.000.000.00
-0.00-0.000.000.01
0.100.09
-0.060.170.08
-0.04-0.050.040.05
-0.01-0.000.010.00
-0.65-0.84
-0.36-0.19
-0.080.050.020.02
-0.00-0.020.00
-0.05-0.040.050.040.480.22
-2.10-1.86
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 47/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
47
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C9 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.730.830.47
-0.01-0.02
0.010.020.000.00
-0.00-0.00-0.41-0.450.070.11
0.540.220.13
-0.09-0.10
0.090.10-0.01-0.000.010.00
-1.56-1.71-0.36-0.22
0.13-0.01-0.01-0.020.02
0.02-0.02-0.07-0.090.070.09
-0.69-0.21-1.94-2.38
0.470.170.10
-0.05-0.06
0.050.06-0.01-0.000.010.00
-0.90-0.98-0.23-0.15
0.12-0.000.00
-0.010.01
0.01-0.01-0.04-0.050.040.05
-0.40-0.12-1.15-1.40
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
2.920.830.47
-0.01-0.02
0.010.020.000.00
-0.00-0.00-0.41-0.450.070.11
-0.71-0.25-0.140.050.05
-0.05-0.050.010.00
-0.01-0.000.820.890.260.19
-0.19-0.01-0.010.01
-0.01
-0.010.010.040.05
-0.04-0.050.360.101.101.34
0.470.170.10
-0.05-0.06
0.050.06-0.01-0.000.010.00
-0.90-0.98-0.23-0.15
0.12-0.000.00
-0.010.01
0.01-0.01-0.04-0.050.040.05
-0.40-0.12-1.15-1.40
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.191.470.90
-0.03-0.050.030.050.02
0.03-0.02-0.03-0.60-0.810.460.65
0.090.020.02
-0.10-0.110.100.11
-0.00
0.000.00
-0.00-1.80-1.95-0.25-0.11
0.010.020.01
-0.030.010.03
-0.01-0.07
-0.090.070.09
-0.98-0.44-2.01-2.50
0.160.040.03
-0.05-0.050.050.05
-0.00
0.000.00
-0.00-0.92-0.99-0.08-0.01
0.050.050.03
-0.020.010.02
-0.01-0.05
-0.070.050.07
-0.72-0.31-1.51-1.88
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
5.691.470.90
-0.03-0.050.030.050.02
0.03-0.02-0.03-0.60-0.810.460.65
-0.18-0.04-0.04-0.02-0.020.020.02
-0.00
-0.000.000.00
-0.29-0.32-0.12-0.09
-0.08-0.06-0.040.00
-0.01-0.000.010.01
0.02-0.01-0.020.210.070.480.61
0.160.040.03
-0.05-0.050.050.05
-0.00
0.000.00
-0.00-0.92-0.99-0.08-0.01
0.050.050.03
-0.020.010.02
-0.01-0.05
-0.070.050.07
-0.72-0.31-1.51-1.88
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C10 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.944.692.68
-0.05-0.050.050.05
-0.01-0.010.010.01
-0.94-1.00-0.37-0.32
-0.43-0.11-0.07-0.15-0.170.150.17
-0.010.000.01
-0.00-2.74-3.02-0.43-0.18
-0.11-0.03-0.02-0.000.010.00
-0.01-0.08-0.080.080.08
-0.070.03
-2.48-2.57
-0.32-0.09-0.06-0.09-0.100.090.10
-0.000.000.00
-0.00-1.61-1.77-0.22-0.08
-0.06-0.03-0.02-0.000.000.00
-0.00-0.05-0.050.050.05
-0.040.02
-1.56-1.61
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
6.124.692.68
-0.05-0.050.050.05
-0.01-0.010.010.01
-0.94-1.00-0.37-0.32
0.410.140.080.080.09
-0.08-0.090.00
-0.01-0.000.011.531.690.160.02
0.050.040.03
-0.00-0.010.000.010.050.06
-0.05-0.060.04
-0.031.641.70
-0.32-0.09-0.06-0.09-0.100.090.10
-0.000.000.00
-0.00-1.61-1.77-0.22-0.08
-0.06-0.03-0.02-0.000.000.00
-0.00-0.05-0.050.050.05
-0.040.02
-1.56-1.61
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
9.045.173.01
-0.19-0.220.190.220.020.03
-0.02-0.03-3.50-3.86
0.440.76
-0.09-0.05-0.03-0.15-0.170.150.17
-0.01-0.000.010.00
-2.81-3.06
-0.48-0.26
-0.13-0.03-0.02-0.010.000.01
-0.00-0.07-0.070.070.07
-0.22-0.12
-2.30-2.39
-0.13-0.07-0.05-0.14-0.160.140.16
-0.01-0.000.010.00
-2.59-2.81
-0.46-0.26
-0.19-0.05-0.04-0.01-0.000.010.00
-0.04-0.040.040.04
-0.17-0.11
-1.32-1.38
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
8.545.173.01
-0.19-0.220.190.220.020.03
-0.02-0.03-3.50-3.86
0.440.76
0.130.070.050.080.09
-0.08-0.090.010.00
-0.01-0.001.461.58
0.270.17
0.190.060.040.000.00
-0.00-0.00-0.01-0.010.010.010.060.06
-0.12-0.12
-0.13-0.07-0.05-0.14-0.160.140.16
-0.01-0.000.010.00
-2.59-2.81
-0.46-0.26
-0.19-0.05-0.04-0.01-0.000.010.00
-0.04-0.040.040.04
-0.17-0.11
-1.32-1.38
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 48/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 48
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C11 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.650.530.30
-0.06-0.05
0.060.05-0.00-0.010.000.01
-0.74-0.72-0.16-0.18
0.610.150.09
-0.10-0.10
0.100.100.000.01
-0.00-0.01-1.79-1.840.070.12
0.640.110.07
-0.020.01
0.02-0.01-0.05-0.060.050.06
-0.66-0.22-1.17-1.57
0.520.110.06
-0.06-0.06
0.060.060.000.00
-0.00-0.00-1.03-1.070.040.07
0.540.100.06
-0.010.01
0.01-0.01-0.03-0.040.030.04
-0.36-0.11-0.68-0.90
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
2.830.530.30
-0.06-0.05
0.060.05-0.00-0.010.000.01
-0.74-0.72-0.16-0.18
-0.76-0.14-0.080.060.06
-0.06-0.06-0.00-0.000.000.000.940.98
-0.03-0.07
-0.79-0.15-0.090.01
-0.01
-0.010.010.020.03
-0.02-0.030.290.070.630.83
0.520.110.06
-0.06-0.06
0.060.060.000.00
-0.00-0.00-1.03-1.070.040.07
0.540.100.06
-0.010.01
0.01-0.01-0.03-0.040.030.04
-0.36-0.11-0.68-0.90
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.981.120.69
-0.09-0.080.090.08
-0.01
-0.010.010.01
-1.48-1.40-0.22-0.30
0.180.080.06
-0.10-0.100.100.100.00
0.00-0.00-0.00-2.09-2.100.120.13
0.120.080.05
-0.030.010.03
-0.01-0.05
-0.070.050.07
-1.08-0.55-1.32-1.81
0.320.150.10
-0.05-0.050.050.050.01
0.01-0.01-0.01-1.04-1.060.200.21
0.240.150.10
-0.020.000.02
-0.00-0.02
-0.030.020.03
-0.61-0.35-0.63-0.87
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
5.481.120.69
-0.09-0.080.090.08
-0.01
-0.010.010.01
-1.48-1.40-0.22-0.30
-0.34-0.16-0.11-0.02-0.020.020.02
-0.01
-0.010.010.01
-0.38-0.36-0.20-0.22
-0.27-0.16-0.11-0.000.000.00
-0.00-0.01
-0.020.010.02
-0.070.03
-0.28-0.37
0.320.150.10
-0.05-0.050.050.050.01
0.01-0.01-0.01-1.04-1.060.200.21
0.240.150.10
-0.020.000.02
-0.00-0.02
-0.030.020.03
-0.61-0.35-0.63-0.87
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C12 CUBIERTA 35x35 4.00/4.20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.06-0.00-0.000.00
-0.000.000.000.000.00
-0.00-0.00-0.000.000.000.00
-0.00-0.000.00
-0.02-0.020.020.02
-0.000.000.00
-0.00-0.00-0.000.00
-0.00
0.00-0.000.00
-0.000.000.00
-0.00-0.01-0.010.010.010.000.00
-0.00-0.00
-0.00-0.000.00
-0.10-0.100.100.10
-0.000.000.00
-0.00-0.01-0.01-0.00-0.00
0.00-0.000.00
-0.000.000.00
-0.00-0.06-0.060.060.060.000.00
-0.01-0.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
0.00-0.00-0.000.00
-0.000.000.000.000.00
-0.00-0.00-0.000.000.000.00
0.000.000.000.000.00
-0.00-0.000.00
-0.00-0.000.000.00
-0.000.000.00
-0.00-0.00-0.000.00
-0.00-0.000.000.00
-0.00-0.000.00
-0.00-0.00-0.00-0.00
-0.00-0.000.00
-0.10-0.100.100.10
-0.000.000.00
-0.00-0.01-0.01-0.00-0.00
0.00-0.000.00
-0.000.000.00
-0.00-0.06-0.060.060.060.000.00
-0.01-0.01
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
PISO2 35x35 3.00/4.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
1.570.050.030.030.03
-0.03-0.03-0.00-0.000.000.000.330.34
-0.05-0.05
0.460.310.180.040.04
-0.04-0.040.000.00
-0.00-0.001.721.71
0.010.01
-0.060.190.11
-0.00-0.000.000.00
-0.07-0.070.070.071.581.39
-0.64-0.49
-0.180.300.170.050.05
-0.05-0.050.00
-0.00-0.000.001.631.62
0.000.00
0.870.200.11
-0.00-0.000.000.00
-0.07-0.070.070.072.021.77
-0.96-0.75
-0.01-0.01-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.390.31
-0.08-0.03
1.270.050.030.030.03
-0.03-0.03-0.00-0.000.000.000.330.34
-0.05-0.05
0.640.020.01
-0.01-0.010.010.010.000.00
-0.00-0.000.080.09
0.010.01
-0.93-0.01-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.00-0.44-0.38
0.320.27
-0.180.300.170.050.05
-0.05-0.050.00
-0.00-0.000.001.631.62
0.000.00
0.870.200.11
-0.00-0.000.000.00
-0.07-0.070.070.072.021.77
-0.96-0.75
-0.01-0.01-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.390.31
-0.08-0.03
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 49/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
49
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.853.381.93
-0.01-0.01
0.010.010.000.00
-0.00-0.00-0.15-0.190.180.22
-0.180.100.05
-0.18-0.18
0.180.18-0.00-0.000.000.00
-3.66-3.66-0.05-0.06
0.300.160.10
-0.010.01
0.01-0.01-0.07-0.080.070.08
-0.65-0.38-2.43-2.67
-0.050.170.09
-0.14-0.14
0.140.14-0.00-0.000.000.00
-2.96-2.95-0.02-0.02
0.200.130.08
-0.010.00
0.01-0.00-0.05-0.060.050.06
-0.68-0.44-1.97-2.19
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
8.053.381.93
-0.01-0.01
0.010.010.000.00
-0.00-0.00-0.15-0.190.180.22
-0.05-0.34-0.190.180.18
-0.18-0.180.000.00
-0.00-0.004.034.01
-0.010.01
-0.22-0.18-0.100.02
-0.00
-0.020.000.070.08
-0.07-0.081.120.772.703.02
-0.050.170.09
-0.14-0.14
0.140.14-0.00-0.000.000.00
-2.96-2.95-0.02-0.02
0.200.130.08
-0.010.00
0.01-0.00-0.05-0.060.050.06
-0.68-0.44-1.97-2.19
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
11.584.112.42
-0.05-0.050.050.05
-0.01
-0.010.010.01
-0.99-1.01-0.19-0.18
-0.20-0.13-0.08-0.13-0.130.130.13
-0.00
-0.000.000.00
-2.50-2.48-0.04-0.06
0.270.080.05
-0.010.000.01
-0.00-0.05
-0.060.050.06
-0.21-0.06-1.69-1.82
-0.31-0.21-0.13-0.09-0.090.090.09
-0.00
-0.000.000.00
-1.72-1.68-0.07-0.10
0.470.130.09
-0.000.000.00
-0.00-0.02
-0.020.020.020.050.08
-0.50-0.53
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
11.084.112.42
-0.05-0.050.050.05
-0.01
-0.010.010.01
-0.99-1.01-0.19-0.18
0.310.210.130.020.02
-0.02-0.020.00
0.00-0.00-0.000.330.300.080.10
-0.50-0.14-0.10-0.000.000.00
-0.00-0.02
-0.030.020.03
-0.30-0.19-0.86-0.95
-0.31-0.21-0.13-0.09-0.090.090.09
-0.00
-0.000.000.00
-1.72-1.68-0.07-0.10
0.470.130.09
-0.000.000.00
-0.00-0.02
-0.020.020.020.050.08
-0.50-0.53
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C13 PISO2 35x35 0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.681.590.910.040.04
-0.04-0.040.020.02
-0.02-0.020.720.740.820.80
-0.21-0.15-0.08-0.15-0.150.150.15
-0.00-0.000.000.00
-2.81-2.82-0.06-0.04
0.300.130.080.00
-0.00-0.000.00
-0.10-0.100.100.100.210.14
-3.41-3.34
-0.20-0.15-0.09-0.09-0.090.090.09
-0.00-0.000.000.00
-1.70-1.71-0.04-0.03
0.190.070.040.00
-0.00-0.000.00
-0.06-0.060.060.060.120.08
-2.04-2.00
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
3.881.590.910.040.04
-0.04-0.040.020.02
-0.02-0.020.720.740.820.80
0.320.250.140.080.08
-0.08-0.080.000.00
-0.00-0.001.611.620.040.03
-0.21-0.06-0.03-0.000.000.00
-0.000.060.05
-0.06-0.05-0.11-0.071.891.86
-0.20-0.15-0.09-0.09-0.090.090.09
-0.00-0.000.000.00
-1.70-1.71-0.04-0.03
0.190.070.040.00
-0.00-0.000.00
-0.06-0.060.060.060.120.08
-2.04-2.00
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
7.762.431.470.080.08
-0.08-0.080.080.08
-0.08-0.081.411.47
2.932.87
0.190.090.06
-0.14-0.140.140.140.00
-0.00-0.000.00
-2.78-2.76
0.020.00
0.170.060.040.00
-0.00-0.000.00
-0.10-0.090.100.090.090.04
-3.36-3.31
0.330.170.10
-0.11-0.110.110.11
-0.00-0.000.000.00
-2.17-2.16
0.020.00
0.280.100.070.00
-0.00-0.000.00
-0.08-0.080.080.080.050.01
-2.79-2.75
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7.252.431.470.080.08
-0.08-0.080.080.08
-0.08-0.081.411.47
2.932.87
-0.36-0.18-0.110.040.04
-0.04-0.040.000.00
-0.00-0.000.800.79
-0.01-0.00
-0.30-0.10-0.07-0.000.000.00
-0.000.030.03
-0.03-0.030.010.02
1.241.23
0.330.170.10
-0.11-0.110.110.11
-0.00-0.000.000.00
-2.17-2.16
0.020.00
0.280.100.070.00
-0.00-0.000.00
-0.08-0.080.080.080.050.01
-2.79-2.75
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 50/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 50
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C14 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.075.112.92
-0.01-0.02
0.010.02-0.02-0.010.020.01
-0.27-0.33-0.50-0.44
0.230.440.25
-0.13-0.13
0.130.13-0.00-0.000.000.00
-2.54-2.55-0.02-0.01
0.410.140.090.02
-0.01
-0.020.01-0.07-0.060.070.060.600.27
-2.64-2.34
0.270.430.25
-0.08-0.08
0.080.08-0.00-0.000.000.00
-1.53-1.54-0.01-0.00
0.250.030.020.01
-0.01
-0.010.01-0.04-0.040.040.040.320.12
-1.54-1.36
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
8.265.112.92
-0.01-0.02
0.010.02-0.02-0.010.020.01
-0.27-0.33-0.50-0.44
-0.47-0.71-0.410.070.07
-0.07-0.070.000.00
-0.00-0.001.521.52
-0.00-0.00
-0.240.050.03
-0.010.00
0.01-0.000.040.03
-0.04-0.03-0.24-0.061.441.27
0.270.430.25
-0.08-0.08
0.080.08-0.00-0.000.000.00
-1.53-1.54-0.01-0.00
0.250.030.020.01
-0.01
-0.010.01-0.04-0.040.040.040.320.12
-1.54-1.36
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
12.065.943.47
-0.01-0.020.010.02
-0.03
-0.030.030.03
-0.21-0.36-1.22-1.08
-0.09-0.15-0.09-0.13-0.130.130.130.00
-0.00-0.000.00
-2.58-2.560.020.00
0.260.110.070.02
-0.01-0.020.01
-0.08
-0.060.080.060.730.37
-2.93-2.60
-0.13-0.24-0.14-0.09-0.090.090.090.00
-0.00-0.000.00
-1.84-1.820.020.01
0.420.160.110.01
-0.00-0.010.00
-0.03
-0.030.030.030.370.20
-1.38-1.23
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
11.565.943.47
-0.01-0.020.010.02
-0.03
-0.030.030.03
-0.21-0.36-1.22-1.08
0.120.240.140.020.02
-0.02-0.02-0.00
-0.000.000.000.460.45
-0.02-0.01
-0.43-0.16-0.110.00
-0.00-0.000.00
-0.02
-0.020.020.020.120.04
-0.65-0.57
-0.13-0.24-0.14-0.09-0.090.090.090.00
-0.00-0.000.00
-1.84-1.820.020.01
0.420.160.110.01
-0.00-0.010.00
-0.03
-0.030.030.030.370.20
-1.38-1.23
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C15 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
13.898.805.030.030.02
-0.03-0.02-0.02-0.010.020.010.870.73
-0.83-0.71
0.740.440.25
-0.10-0.100.100.10
-0.00-0.000.000.00
-1.97-1.980.020.03
-0.07-0.78-0.440.03
-0.02-0.030.02
-0.09-0.060.090.061.350.67
-3.46-2.85
0.870.480.27
-0.06-0.060.060.06
-0.00-0.000.000.00
-1.18-1.180.030.04
-0.25-0.91-0.520.02
-0.01-0.020.01
-0.05-0.040.050.040.850.44
-2.14-1.77
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
13.088.805.030.030.02
-0.03-0.02-0.02-0.010.020.010.870.73
-0.83-0.71
-1.56-0.82-0.470.060.06
-0.06-0.060.000.00
-0.00-0.001.161.16
-0.06-0.06
0.591.630.93
-0.020.010.02
-0.010.050.04
-0.05-0.04-0.91-0.492.211.83
0.870.480.27
-0.06-0.060.060.06
-0.00-0.000.000.00
-1.18-1.180.030.04
-0.25-0.91-0.520.02
-0.01-0.020.01
-0.05-0.040.050.040.850.44
-2.14-1.77
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
15.979.275.350.070.05
-0.07-0.05-0.04-0.030.040.031.861.56
-1.69-1.42
-0.59-0.27-0.16-0.11-0.100.110.100.000.00
-0.00-0.00-2.12-2.10
0.01-0.00
0.450.480.280.04
-0.01-0.040.01
-0.09-0.060.090.061.250.59
-3.38-2.78
-0.95-0.43-0.26-0.05-0.050.050.050.000.00
-0.00-0.00-1.08-1.07
0.01-0.01
0.710.750.450.02
-0.00-0.020.00
-0.04-0.030.040.030.510.23
-1.45-1.20
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
15.469.275.350.070.05
-0.07-0.05-0.04-0.030.040.031.861.56
-1.69-1.42
0.980.440.27
-0.02-0.020.020.02
-0.00-0.000.000.00
-0.33-0.34
-0.000.01
-0.72-0.76-0.450.01
-0.01-0.010.01
-0.02-0.020.020.020.400.21
-0.98-0.81
-0.95-0.43-0.26-0.05-0.050.050.050.000.00
-0.00-0.00-1.08-1.07
0.01-0.01
0.710.750.450.02
-0.00-0.020.00
-0.04-0.030.040.030.510.23
-1.45-1.20
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 51/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
51
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C16 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.720.850.49
-0.06-0.05
0.060.050.00
-0.01-0.000.01
-1.12-0.960.150.01
0.400.030.02
-0.12-0.09
0.120.090.01
-0.00-0.010.00
-2.48-2.150.590.30
-0.17-0.14-0.08-0.030.02
0.03-0.02-0.06-0.090.060.09
-1.06-0.42-1.66-2.25
0.350.040.02
-0.07-0.05
0.070.050.01
-0.00-0.010.00
-1.46-1.270.350.18
-0.10-0.09-0.05-0.020.01
0.02-0.01-0.04-0.050.040.05
-0.64-0.25-1.00-1.36
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
4.910.850.49
-0.06-0.05
0.060.050.00
-0.01-0.000.01
-1.12-0.960.150.01
-0.52-0.07-0.040.070.05
-0.07-0.05-0.010.000.01
-0.001.401.22
-0.34-0.17
0.080.090.050.02
-0.01
-0.020.010.040.05
-0.04-0.050.630.251.001.35
0.350.040.02
-0.07-0.05
0.070.050.01
-0.00-0.010.00
-1.46-1.270.350.18
-0.10-0.09-0.05-0.020.01
0.02-0.01-0.04-0.050.040.05
-0.64-0.25-1.00-1.36
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.651.651.02
-0.10-0.070.100.07
-0.00
-0.010.000.01
-1.99-1.670.18
-0.11
0.190.090.06
-0.12-0.100.120.100.01
-0.00-0.010.00
-2.80-2.420.680.34
-0.11-0.02-0.02-0.040.010.04
-0.01-0.06
-0.080.060.08
-1.29-0.63-1.65-2.25
0.350.170.12
-0.06-0.050.060.050.01
-0.00-0.010.00
-1.40-1.200.340.17
-0.14-0.01-0.01-0.030.010.03
-0.01-0.04
-0.060.040.06
-0.96-0.49-1.17-1.60
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
8.151.651.02
-0.10-0.070.100.07
-0.00
-0.010.000.01
-1.99-1.670.18
-0.11
-0.39-0.20-0.13-0.03-0.020.030.020.00
-0.00-0.000.00
-0.50-0.440.120.06
0.120.000.010.01
-0.00-0.010.000.01
0.01-0.01-0.010.300.180.290.40
0.350.170.12
-0.06-0.050.060.050.01
-0.00-0.010.00
-1.40-1.200.340.17
-0.14-0.01-0.01-0.030.010.03
-0.01-0.04
-0.060.040.06
-0.96-0.49-1.17-1.60
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C17 CUBIERTA 35x35 4.00/4.20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.060.000.000.00
-0.000.000.00
-0.000.000.00
-0.000.000.00
-0.00-0.00
-0.00-0.000.00
-0.02-0.020.020.02
-0.00-0.000.000.00
-0.00-0.000.000.00
0.000.00
-0.000.00
-0.00-0.000.00
-0.01-0.010.010.010.000.00
-0.00-0.00
0.00-0.000.00
-0.10-0.100.100.10
-0.00-0.000.000.00
-0.01-0.010.000.00
0.000.00
-0.000.00
-0.00-0.000.00
-0.06-0.060.060.060.000.00
-0.01-0.01
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
-0.000.000.000.00
-0.000.000.00
-0.000.000.00
-0.000.000.00
-0.00-0.00
-0.000.00
-0.00-0.00-0.000.000.000.00
-0.00-0.000.00
-0.00-0.00-0.00-0.00
0.00-0.000.000.000.00
-0.00-0.00-0.00-0.000.000.00
-0.00-0.000.000.00
0.00-0.000.00
-0.10-0.100.100.10
-0.00-0.000.000.00
-0.01-0.010.000.00
0.000.00
-0.000.00
-0.00-0.000.00
-0.06-0.060.060.060.000.00
-0.01-0.01
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
PISO2 35x35 3.00/4.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
2.590.080.040.030.03
-0.03-0.03-0.00-0.000.000.000.480.42
-0.13-0.08
0.820.450.260.060.03
-0.06-0.03-0.010.000.01
-0.002.291.96
-0.59-0.29
-0.00-0.05-0.030.000.00
-0.00-0.00-0.08-0.080.080.082.201.98
-0.89-0.70
0.160.430.250.070.05
-0.07-0.05-0.010.000.01
-0.002.161.84
-0.57-0.28
0.12-0.03-0.02-0.000.000.00
-0.00-0.09-0.090.090.092.892.61
-1.46-1.23
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.260.20
-0.06-0.02
2.280.080.040.030.03
-0.03-0.03-0.00-0.000.000.000.480.42
-0.13-0.08
0.660.020.01
-0.01-0.010.010.01
-0.000.000.00
-0.000.130.12
-0.03-0.01
-0.12-0.01-0.010.00
-0.00-0.000.000.010.01
-0.01-0.01-0.68-0.63
0.570.53
0.160.430.250.070.05
-0.07-0.05-0.010.000.01
-0.002.161.84
-0.57-0.28
0.12-0.03-0.02-0.000.000.00
-0.00-0.09-0.090.090.092.892.61
-1.46-1.23
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.260.20
-0.06-0.02
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 52/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 52
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
10.063.952.26
-0.000.00
0.00-0.00-0.00-0.010.000.01
-0.30-0.25-0.05-0.10
-0.070.020.01
-0.21-0.16
0.210.160.02
-0.00-0.020.00
-4.77-4.141.150.57
-0.23-0.10-0.06-0.010.01
0.01-0.01-0.09-0.100.090.10
-0.79-0.48-2.92-3.20
0.110.130.07
-0.16-0.12
0.160.120.02
-0.00-0.020.00
-3.83-3.320.930.46
-0.21-0.10-0.06-0.010.01
0.01-0.01-0.06-0.070.060.07
-0.78-0.52-2.23-2.47
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
9.273.952.26
-0.000.00
0.00-0.00-0.00-0.010.000.01
-0.30-0.25-0.05-0.10
-0.36-0.32-0.180.210.16
-0.21-0.16-0.020.000.02
-0.005.194.50
-1.26-0.63
0.320.160.090.02
-0.01
-0.020.010.070.09
-0.07-0.091.240.872.883.21
0.110.130.07
-0.16-0.12
0.160.120.02
-0.00-0.020.00
-3.83-3.320.930.46
-0.21-0.10-0.06-0.010.01
0.01-0.01-0.06-0.070.060.07
-0.78-0.52-2.23-2.47
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
13.484.912.90
-0.05-0.030.050.03
-0.01
-0.010.010.01
-1.37-1.16-0.02-0.21
-0.25-0.13-0.08-0.15-0.120.150.120.02
-0.00-0.020.00
-3.37-2.910.820.40
-0.07-0.01-0.01-0.010.000.01
-0.00-0.07
-0.080.070.08
-0.32-0.12-2.29-2.48
-0.37-0.18-0.11-0.11-0.090.110.090.01
-0.00-0.010.00
-2.33-2.010.570.28
-0.09-0.02-0.02-0.010.000.01
-0.00-0.05
-0.050.050.05
-0.14-0.01-1.50-1.62
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
12.984.912.90
-0.05-0.030.050.03
-0.01
-0.010.010.01
-1.37-1.16-0.02-0.21
0.360.170.110.030.02
-0.03-0.02-0.00
0.000.00
-0.000.470.40
-0.12-0.06
0.080.020.010.000.00
-0.00-0.000.01
0.01-0.01-0.01-0.10-0.100.190.19
-0.37-0.18-0.11-0.11-0.090.110.090.01
-0.00-0.010.00
-2.33-2.010.570.28
-0.09-0.02-0.02-0.010.000.01
-0.00-0.05
-0.050.050.05
-0.14-0.01-1.50-1.62
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C18 PISO2 35x35 0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.941.570.900.050.04
-0.05-0.04-0.01-0.010.010.011.100.96
-0.47-0.35
-0.35-0.23-0.13-0.17-0.140.170.140.02
-0.00-0.020.00
-3.73-3.240.890.44
-0.110.030.020.00
-0.00-0.000.00
-0.09-0.090.090.090.200.13
-2.97-2.91
-0.31-0.18-0.10-0.10-0.080.100.080.01
-0.00-0.010.00
-2.26-1.960.540.27
-0.080.020.010.00
-0.00-0.000.00
-0.05-0.050.050.050.110.08
-1.81-1.78
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
4.151.570.900.050.04
-0.05-0.04-0.01-0.010.010.011.100.96
-0.47-0.35
0.460.250.140.100.08
-0.10-0.08-0.010.000.01
-0.002.151.87
-0.51-0.25
0.10-0.01-0.01-0.000.000.00
-0.000.050.05
-0.05-0.05-0.10-0.071.741.70
-0.31-0.18-0.10-0.10-0.080.100.080.01
-0.00-0.010.00
-2.26-1.960.540.27
-0.080.020.010.00
-0.00-0.000.00
-0.05-0.050.050.050.110.08
-1.81-1.78
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
8.382.551.550.100.08
-0.10-0.08-0.03-0.010.030.012.141.86
-1.07-0.81
0.210.090.05
-0.17-0.130.170.130.02
-0.00-0.020.00
-3.73-3.22
0.910.45
-0.08-0.04-0.020.00
-0.00-0.000.00
-0.08-0.080.080.080.080.04
-2.86-2.82
0.390.170.10
-0.13-0.100.130.100.01
-0.00-0.010.00
-2.92-2.52
0.720.35
-0.12-0.07-0.040.00
-0.00-0.000.00
-0.06-0.050.060.050.030.00
-1.97-1.95
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7.882.551.550.100.08
-0.10-0.08-0.03-0.010.030.012.141.86
-1.07-0.81
-0.43-0.19-0.120.050.04
-0.05-0.04-0.010.000.01
-0.001.090.94
-0.27-0.14
0.120.070.05
-0.000.000.00
-0.000.010.01
-0.01-0.010.030.03
0.390.39
0.390.170.10
-0.13-0.100.130.100.01
-0.00-0.010.00
-2.92-2.52
0.720.35
-0.12-0.07-0.040.00
-0.00-0.000.00
-0.06-0.050.060.050.030.00
-1.97-1.95
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 53/89
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 54/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 54
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C21 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.540.440.25
-0.06-0.05
0.060.050.020.01
-0.02-0.01-0.91-0.800.710.61
0.35-0.03-0.01-0.13-0.08
0.130.080.02
-0.00-0.020.00
-2.97-2.371.110.56
-0.65-0.19-0.11-0.020.01
0.02-0.01-0.05-0.070.050.07
-0.68-0.21-1.26-1.69
0.330.020.01
-0.08-0.05
0.080.050.01
-0.00-0.010.00
-1.76-1.400.650.33
-0.52-0.12-0.07-0.010.01
0.01-0.01-0.03-0.040.030.04
-0.36-0.09-0.74-0.99
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
2.720.440.25
-0.06-0.05
0.060.050.020.01
-0.02-0.01-0.91-0.800.710.61
-0.52-0.07-0.040.070.05
-0.07-0.05-0.010.000.01
-0.001.691.35
-0.63-0.31
0.730.120.070.01
-0.01
-0.010.010.030.04
-0.03-0.040.270.020.690.92
0.330.020.01
-0.08-0.05
0.080.050.01
-0.00-0.010.00
-1.76-1.400.650.33
-0.52-0.12-0.07-0.010.01
0.01-0.01-0.03-0.040.030.04
-0.36-0.09-0.74-0.99
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.610.930.58
-0.09-0.080.090.080.04
0.04-0.04-0.04-1.48-1.381.521.42
0.170.090.06
-0.14-0.090.140.090.02
-0.00-0.020.00
-3.39-2.711.240.61
-0.08-0.05-0.04-0.030.010.03
-0.01-0.05
-0.070.050.07
-1.13-0.57-1.39-1.90
0.330.180.12
-0.07-0.040.070.040.01
-0.00-0.010.00
-1.69-1.350.610.31
-0.09-0.06-0.05-0.020.000.02
-0.00-0.03
-0.040.030.04
-0.70-0.39-0.74-1.02
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
5.100.930.58
-0.09-0.080.090.080.04
0.04-0.04-0.04-1.48-1.381.521.42
-0.38-0.22-0.14-0.03-0.020.030.020.00
-0.00-0.000.00
-0.60-0.480.220.11
0.070.050.04
-0.000.000.00
-0.00-0.01
-0.010.010.010.020.07
-0.16-0.21
0.330.180.12
-0.07-0.040.070.040.01
-0.00-0.010.00
-1.69-1.350.610.31
-0.09-0.06-0.05-0.020.000.02
-0.00-0.03
-0.040.030.04
-0.70-0.39-0.74-1.02
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C22 CUBIERTA 35x35 4.00/4.20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.060.000.000.000.00
-0.000.00
-0.000.000.00
-0.00-0.000.00
-0.000.00
-0.00-0.000.00
-0.02-0.020.020.020.000.00
-0.00-0.00-0.00-0.00-0.00-0.00
0.000.000.00
-0.000.000.00
-0.00-0.01-0.010.010.010.000.00
-0.00-0.00
-0.00-0.000.00
-0.10-0.100.100.100.000.00
-0.00-0.00-0.01-0.01-0.00-0.00
0.000.000.00
-0.000.000.00
-0.00-0.06-0.060.060.060.00
-0.00-0.01-0.01
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
0.000.000.000.000.00
-0.000.00
-0.000.000.00
-0.00-0.000.00
-0.000.00
0.000.000.000.000.00
-0.00-0.00-0.00-0.000.000.000.000.000.000.00
0.00-0.000.000.00
-0.00-0.000.00
-0.00-0.000.000.00
-0.000.00
-0.00-0.00
-0.00-0.000.00
-0.10-0.100.100.100.000.00
-0.00-0.00-0.01-0.01-0.00-0.00
0.000.000.00
-0.000.000.00
-0.00-0.06-0.060.060.060.00
-0.00-0.01-0.01
-0.00-0.00-0.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.01
-0.01-0.010.01
PISO2 35x35 3.00/4.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
1.810.030.020.030.03
-0.03-0.030.000.01
-0.00-0.010.490.39
-0.090.00
0.430.210.120.070.03
-0.07-0.03-0.020.000.02
-0.002.431.89
-0.98-0.49
0.01-0.17-0.100.00
-0.00-0.000.00
-0.04-0.040.040.041.971.72
-0.020.20
-0.180.190.110.080.04
-0.08-0.04-0.020.000.02
-0.002.221.71
-0.93-0.46
-0.99-0.17-0.090.00
-0.00-0.000.00
-0.05-0.040.050.042.652.34
-0.39-0.12
0.010.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.330.26
-0.09-0.04
1.500.030.020.030.03
-0.03-0.030.000.01
-0.00-0.010.490.39
-0.090.00
0.610.020.01
-0.01-0.010.010.01
-0.000.000.00
-0.000.210.18
-0.06-0.03
1.00-0.01-0.000.000.00
-0.00-0.000.000.00
-0.00-0.00-0.68-0.62
0.370.32
-0.180.190.110.080.04
-0.08-0.04-0.020.000.02
-0.002.221.71
-0.93-0.46
-0.99-0.17-0.090.00
-0.00-0.000.00
-0.05-0.040.050.042.652.34
-0.39-0.12
0.010.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.330.26
-0.09-0.04
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 55/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
55
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.251.781.020.000.00
-0.00-0.000.040.04
-0.04-0.04-0.37-0.361.011.01
-0.40-0.26-0.15-0.23-0.14
0.230.140.04
-0.01-0.040.01
-5.52-4.402.071.04
-0.45-0.20-0.12-0.010.00
0.01-0.00-0.06-0.060.060.06
-0.75-0.50-2.08-2.30
-0.24-0.16-0.09-0.18-0.11
0.180.110.03
-0.01-0.030.01
-4.33-3.441.630.82
-0.42-0.20-0.12-0.010.00
0.01-0.00-0.03-0.040.030.04
-0.79-0.58-1.48-1.67
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
5.441.781.020.000.00
-0.00-0.000.040.04
-0.04-0.04-0.37-0.361.011.01
0.250.160.090.240.15
-0.24-0.15-0.040.010.04
-0.015.954.72
-2.25-1.13
0.650.340.200.01
-0.00
-0.010.000.040.04
-0.04-0.041.331.031.852.12
-0.24-0.16-0.09-0.18-0.11
0.180.110.03
-0.01-0.030.01
-4.33-3.441.630.82
-0.42-0.20-0.12-0.010.00
0.01-0.00-0.03-0.040.030.04
-0.79-0.58-1.48-1.67
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.792.431.45
-0.04-0.030.040.030.07
0.06-0.07-0.06-1.43-1.252.172.01
-0.17-0.06-0.04-0.18-0.120.180.120.03
-0.00-0.030.00
-4.15-3.321.500.74
-0.13-0.03-0.02-0.010.000.01
-0.00-0.06
-0.070.060.07
-0.19-0.03-1.97-2.12
-0.22-0.05-0.04-0.13-0.080.130.080.02
-0.00-0.020.00
-2.94-2.351.040.51
-0.20-0.04-0.03-0.000.000.00
-0.00-0.03
-0.040.030.040.070.13
-0.97-1.03
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
8.282.431.45
-0.04-0.030.040.030.07
0.06-0.07-0.06-1.43-1.252.172.01
0.190.030.030.030.02
-0.03-0.02-0.00
0.000.00
-0.000.700.56
-0.23-0.11
0.200.040.03
-0.000.000.00
-0.00-0.01
-0.010.010.01
-0.32-0.25-0.37-0.43
-0.22-0.05-0.04-0.13-0.080.130.080.02
-0.00-0.020.00
-2.94-2.351.040.51
-0.20-0.04-0.03-0.000.000.00
-0.00-0.03
-0.040.030.040.070.13
-0.97-1.03
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C23 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.220.770.440.050.04
-0.05-0.040.010.02
-0.01-0.021.200.980.100.30
-0.29-0.24-0.13-0.19-0.120.190.120.03
-0.01-0.030.01
-4.39-3.511.610.81
-0.28-0.06-0.040.00
-0.00-0.000.00
-0.07-0.060.070.060.150.10
-2.21-2.17
-0.22-0.16-0.09-0.11-0.070.110.070.02
-0.00-0.020.00
-2.64-2.110.970.49
-0.20-0.06-0.040.00
-0.00-0.000.00
-0.04-0.040.040.040.080.06
-1.27-1.25
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
2.410.770.440.050.04
-0.05-0.040.010.02
-0.01-0.021.200.980.100.30
0.300.180.100.110.07
-0.11-0.07-0.020.000.02
-0.002.612.09
-0.95-0.48
0.250.090.05
-0.000.000.00
-0.000.030.03
-0.03-0.03-0.07-0.041.171.15
-0.22-0.16-0.09-0.11-0.070.110.070.02
-0.00-0.020.00
-2.64-2.110.970.49
-0.20-0.06-0.040.00
-0.00-0.000.00
-0.04-0.040.040.040.080.06
-1.27-1.25
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
5.781.450.890.100.07
-0.10-0.070.020.04
-0.02-0.042.391.94
0.490.91
0.150.060.04
-0.19-0.120.190.120.03
-0.00-0.030.00
-4.53-3.62
1.650.82
-0.18-0.06-0.040.00
-0.00-0.000.00
-0.07-0.070.070.070.060.02
-2.47-2.44
0.310.140.09
-0.15-0.100.150.100.02
-0.00-0.020.00
-3.56-2.84
1.300.64
-0.29-0.11-0.070.00
-0.00-0.000.00
-0.04-0.040.040.04
-0.01-0.02
-1.33-1.32
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
5.281.450.890.100.07
-0.10-0.070.020.04
-0.02-0.042.391.94
0.490.91
-0.36-0.18-0.110.060.04
-0.06-0.04-0.010.000.01
-0.001.351.08
-0.49-0.24
0.290.120.080.000.00
-0.00-0.00-0.01-0.010.010.010.070.06
-0.28-0.27
0.310.140.09
-0.15-0.100.150.100.02
-0.00-0.020.00
-3.56-2.84
1.300.64
-0.29-0.11-0.070.00
-0.00-0.000.00
-0.04-0.040.040.04
-0.01-0.02
-1.33-1.32
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 56/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 56
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C24 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.354.162.37
-0.03-0.01
0.030.010.020.02
-0.02-0.02-0.41-0.250.710.56
0.150.080.04
-0.17-0.11
0.170.110.03
-0.00-0.030.00
-3.92-3.121.460.74
0.330.300.170.02
-0.01
-0.020.01-0.08-0.070.080.070.700.33
-2.91-2.57
0.250.160.09
-0.10-0.06
0.100.060.02
-0.00-0.020.00
-2.32-1.840.870.44
0.380.270.150.01
-0.01
-0.010.01-0.05-0.040.050.040.400.18
-1.73-1.53
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
8.544.162.37
-0.03-0.01
0.030.010.020.02
-0.02-0.02-0.41-0.250.710.56
-0.52-0.36-0.210.100.06
-0.10-0.06-0.020.000.02
-0.002.231.77
-0.85-0.42
-0.67-0.40-0.23-0.010.00
0.01-0.000.050.04
-0.05-0.04-0.37-0.151.681.49
0.250.160.09
-0.10-0.06
0.100.060.02
-0.00-0.020.00
-2.32-1.840.870.44
0.380.270.150.01
-0.01
-0.010.01-0.05-0.040.050.040.400.18
-1.73-1.53
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
12.094.872.85
-0.04-0.010.040.010.05
0.04-0.05-0.04-0.85-0.521.841.53
-0.16-0.10-0.06-0.18-0.110.180.110.03
-0.00-0.030.00
-4.23-3.381.530.76
-0.38-0.18-0.110.02
-0.01-0.020.01
-0.08
-0.070.080.070.730.36
-3.05-2.70
-0.21-0.13-0.07-0.13-0.080.130.080.02
-0.00-0.020.00
-3.08-2.461.100.55
-0.64-0.31-0.190.01
-0.00-0.010.00
-0.04
-0.030.040.030.370.18
-1.58-1.41
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
11.594.872.85
-0.04-0.010.040.010.05
0.04-0.05-0.04-0.85-0.521.841.53
0.180.100.060.030.02
-0.03-0.02-0.01
0.000.01
-0.000.840.68
-0.29-0.14
0.670.340.210.00
-0.00-0.000.00
-0.01
-0.010.010.010.120.06
-0.44-0.38
-0.21-0.13-0.07-0.13-0.080.130.080.02
-0.00-0.020.00
-3.08-2.461.100.55
-0.64-0.31-0.190.01
-0.00-0.010.00
-0.04
-0.030.040.030.370.18
-1.58-1.41
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C25 PISO2 35x35 0.00/2.65 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.011.500.860.020.02
-0.02-0.020.020.02
-0.02-0.020.200.230.780.76
-0.81-0.44-0.26-0.14-0.090.140.090.02
-0.00-0.020.00
-3.17-2.541.160.58
0.500.330.190.03
-0.02-0.030.02
-0.09-0.060.090.061.130.48
-3.30-2.70
-0.61-0.32-0.18-0.08-0.050.080.050.01
-0.00-0.010.00
-1.92-1.540.700.35
0.520.260.150.02
-0.01-0.020.01
-0.05-0.040.050.040.610.23
-1.89-1.55
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
4.201.500.860.020.02
-0.02-0.020.020.02
-0.02-0.020.200.230.780.76
0.800.410.230.080.05
-0.08-0.05-0.010.000.01
-0.001.931.54
-0.69-0.34
-0.88-0.35-0.20-0.020.010.02
-0.010.050.03
-0.05-0.03-0.49-0.141.721.40
-0.61-0.32-0.18-0.08-0.050.080.050.01
-0.00-0.010.00
-1.92-1.540.700.35
0.520.260.150.02
-0.01-0.020.01
-0.05-0.040.050.040.610.23
-1.89-1.55
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
6.991.951.160.060.06
-0.06-0.060.040.04
-0.04-0.040.820.88
1.641.59
-0.060.01
-0.00-0.14-0.090.140.090.02
-0.00-0.020.00
-3.42-2.73
1.240.61
-0.42-0.16-0.100.04
-0.01-0.040.01
-0.09-0.060.090.061.420.71
-3.70-3.05
-0.050.060.02
-0.07-0.050.070.050.01
-0.00-0.010.00
-1.74-1.39
0.620.30
-0.73-0.30-0.180.02
-0.00-0.020.00
-0.05-0.030.050.030.800.43
-1.99-1.65
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
6.481.951.160.060.06
-0.06-0.060.040.04
-0.04-0.040.820.88
1.641.59
0.01-0.09-0.04-0.02-0.020.020.020.00
-0.00-0.000.00
-0.55-0.44
0.220.12
0.780.340.200.00
-0.00-0.000.00
-0.01-0.010.010.010.100.01
-0.42-0.34
-0.050.060.02
-0.07-0.050.070.050.01
-0.00-0.010.00
-1.74-1.39
0.620.30
-0.73-0.30-0.180.02
-0.00-0.020.00
-0.05-0.030.050.030.800.43
-1.99-1.65
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 57/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
57
Soporte Planta Dimensión(cm)
Tramo(m)
HipótesisBase Cabeza
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C26 PISO2 35x35 0.00/2.60 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
1.820.840.480.080.08
-0.08-0.080.00
-0.00-0.000.001.341.450.05
-0.05
-0.08-0.03-0.02-0.13-0.15
0.130.15-0.010.000.01
-0.00-2.38-2.61-0.48-0.26
-0.060.060.030.00
-0.00
-0.000.00-0.11-0.110.110.110.220.15
-3.65-3.59
-0.03-0.03-0.01-0.08-0.09
0.080.09-0.01-0.000.010.00
-1.41-1.54-0.29-0.17
-0.040.040.020.00
-0.00
-0.000.00-0.06-0.060.060.060.130.08
-2.18-2.14
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
1.020.840.480.080.08
-0.08-0.080.00
-0.00-0.000.001.341.450.05
-0.05
-0.010.040.020.070.08
-0.07-0.080.010.00
-0.01-0.001.281.400.290.18
0.04-0.05-0.03-0.000.00
0.00-0.000.060.06
-0.06-0.06-0.11-0.072.011.97
-0.03-0.03-0.01-0.08-0.09
0.080.09-0.01-0.000.010.00
-1.41-1.54-0.29-0.17
-0.040.040.020.00
-0.00
-0.000.00-0.06-0.060.060.060.130.08
-2.18-2.14
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.020.01
-0.02-0.01
PISO1 35x35 -2.00/-0.35 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.521.250.740.250.28
-0.25-0.28-0.03
-0.050.030.054.554.93
-0.83-1.18
-0.04-0.02-0.01-0.13-0.150.130.15
-0.01
0.000.01
-0.00-2.44-2.65-0.37-0.18
-0.08-0.04-0.030.00
-0.00-0.000.00
-0.10
-0.100.100.100.110.05
-3.60-3.54
-0.06-0.03-0.02-0.11-0.120.110.12
-0.00
0.000.00
-0.00-1.98-2.15-0.27-0.12
-0.12-0.07-0.050.00
-0.00-0.000.00
-0.09
-0.090.090.090.080.03
-3.18-3.13
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
3.011.250.740.250.28
-0.25-0.28-0.03
-0.050.030.054.554.93
-0.83-1.18
0.060.030.020.040.05
-0.04-0.050.00
-0.00-0.000.000.820.890.080.02
0.120.080.05
-0.000.000.00
-0.000.05
0.05-0.05-0.05-0.020.001.651.63
-0.06-0.03-0.02-0.11-0.120.110.12
-0.00
0.000.00
-0.00-1.98-2.15-0.27-0.12
-0.12-0.07-0.050.00
-0.00-0.000.00
-0.09
-0.090.090.090.080.03
-3.18-3.13
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
4.- ARRANQUES DE PILARES, PANTALLAS Y MUROS POR HIPÓTESIS
Nota:
Los esfuerzos están referidos a ejes locales del pilar.
Soporte HipótesisEsfuerzos en arranques
N
(t)
Mx
(t·m)
My
(t·m)
Qx
(t)
Qy
(t)
T
(t·m)C1 Peso propio
Cargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
4.681.120.68
-0.08-0.090.080.09
-0.06-0.060.060.06
-1.29-1.33-2.14-2.10
0.09-0.01-0.00-0.07-0.110.070.11
-0.020.000.02
-0.00-0.87-1.50-1.14-0.57
0.070.030.02
-0.030.010.03
-0.01-0.06-0.080.060.08
-0.91-0.45-1.74-2.16
0.14-0.04-0.01-0.03-0.050.030.05
-0.010.000.01
-0.00-0.43-0.73-0.56-0.28
0.140.060.04
-0.020.000.02
-0.00-0.03-0.050.030.05
-0.61-0.32-1.06-1.33
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 58/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 58
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C2 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.351.841.10
-0.14-0.23
0.140.23-0.14-0.090.140.09
-1.86-3.03-5.02-3.97
-0.010.040.01
-0.10-0.17
0.100.17-0.030.000.03
-0.00-1.25-2.15-1.64-0.82
0.120.070.04
-0.010.00
0.01-0.00-0.07-0.070.070.07
-0.20-0.11-2.25-2.33
-0.030.040.02
-0.09-0.14
0.090.14-0.030.000.03
-0.00-1.05-1.81-1.37-0.68
0.210.110.07
-0.00-0.00
0.000.00-0.04-0.040.040.04
-0.14-0.10-1.24-1.28
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C3 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.056.924.000.170.27
-0.17-0.27-0.02
-0.070.020.072.073.440.38
-0.86
0.08-0.08-0.04-0.11-0.180.110.18
-0.03
0.000.03
-0.00-1.36-2.33-1.77-0.89
0.01-0.10-0.050.000.00
-0.00-0.00-0.07
-0.070.070.070.080.05
-2.63-2.60
0.12-0.15-0.08-0.10-0.160.100.16
-0.03
0.000.03
-0.00-1.23-2.11-1.60-0.80
0.01-0.17-0.090.000.00
-0.00-0.00-0.04
-0.040.040.040.030.02
-1.59-1.58
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C4 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
6.383.942.290.050.04
-0.05-0.04-0.07-0.070.070.071.141.04
-2.53-2.44
0.060.240.13
-0.07-0.110.070.11
-0.020.000.02
-0.00-0.86-1.48-1.12-0.55
0.03-0.07-0.040.02
-0.01-0.020.01
-0.09-0.070.090.070.800.39
-3.35-2.98
0.090.380.20
-0.03-0.050.030.05
-0.010.000.01
-0.00-0.41-0.71-0.52-0.25
0.04-0.14-0.070.02
-0.00-0.020.00
-0.05-0.040.050.040.490.23
-2.09-1.85
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C5 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
5.851.440.88
-0.07-0.090.070.09
-0.000.010.00
-0.01-0.86-1.18
-0.31-0.03
0.090.010.02
-0.08-0.110.080.11
-0.010.000.01
-0.00-1.34-1.72
-0.71-0.35
-0.02-0.01-0.00-0.030.010.03
-0.01-0.07-0.100.070.10
-1.13-0.55
-2.22-2.75
0.150.020.02
-0.04-0.050.040.05
-0.010.000.01
-0.00-0.67-0.86
-0.34-0.17
-0.010.000.00
-0.030.010.03
-0.01-0.06-0.080.060.08
-0.98-0.49
-1.85-2.29
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 59/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
59
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C6 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.573.361.99
-0.17-0.23
0.170.23-0.000.030.00
-0.03-2.61-3.46-1.00-0.23
-0.03-0.01-0.01-0.12-0.16
0.120.16-0.020.000.02
-0.00-1.91-2.47-1.02-0.51
-0.05-0.05-0.03-0.010.00
0.01-0.00-0.09-0.090.090.09
-0.24-0.12-2.90-3.01
-0.05-0.02-0.02-0.10-0.14
0.100.14-0.020.000.02
-0.00-1.61-2.08-0.85-0.43
-0.07-0.08-0.05-0.010.00
0.01-0.00-0.07-0.080.070.08
-0.20-0.11-2.30-2.40
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C7 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.366.323.680.200.27
-0.20-0.270.04
0.01-0.04-0.013.003.912.061.23
0.10-0.03-0.01-0.13-0.170.130.17
-0.02
0.000.02
-0.00-2.05-2.65-1.09-0.54
0.030.070.040.00
-0.00-0.000.00
-0.09
-0.090.090.090.100.05
-3.29-3.25
0.16-0.05-0.02-0.11-0.150.110.15
-0.02
0.000.02
-0.00-1.85-2.39-0.98-0.48
0.060.100.060.00
-0.00-0.000.00
-0.08
-0.070.080.070.060.02
-2.68-2.64
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C8 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.172.531.490.020.06
-0.02-0.060.090.07
-0.09-0.07-0.170.393.362.86
-0.030.110.05
-0.08-0.110.080.11
-0.010.000.01
-0.00-1.32-1.71-0.72-0.37
-0.040.040.020.02
-0.01-0.020.01
-0.09-0.070.090.070.800.38
-3.36-2.98
-0.060.170.08
-0.04-0.050.040.05
-0.01-0.000.010.00
-0.65-0.84-0.36-0.19
-0.080.050.020.02
-0.00-0.020.00
-0.05-0.040.050.040.480.22
-2.10-1.86
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C9 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
6.191.470.90
-0.03-0.050.030.050.020.03
-0.02-0.03-0.60-0.81
0.460.65
0.090.020.02
-0.10-0.110.100.11
-0.000.000.00
-0.00-1.80-1.95
-0.25-0.11
0.010.020.01
-0.030.010.03
-0.01-0.07-0.090.070.09
-0.98-0.44
-2.01-2.50
0.160.040.03
-0.05-0.050.050.05
-0.000.000.00
-0.00-0.92-0.99
-0.08-0.01
0.050.050.03
-0.020.010.02
-0.01-0.05-0.070.050.07
-0.72-0.31
-1.51-1.88
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 60/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 60
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C10 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.045.173.01
-0.19-0.22
0.190.220.020.03
-0.02-0.03-3.50-3.860.440.76
-0.09-0.05-0.03-0.15-0.17
0.150.17-0.01-0.000.010.00
-2.81-3.06-0.48-0.26
-0.13-0.03-0.02-0.010.00
0.01-0.00-0.07-0.070.070.07
-0.22-0.12-2.30-2.39
-0.13-0.07-0.05-0.14-0.16
0.140.16-0.01-0.000.010.00
-2.59-2.81-0.46-0.26
-0.19-0.05-0.04-0.01-0.00
0.010.00-0.04-0.040.040.04
-0.17-0.11-1.32-1.38
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C11 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.981.120.69
-0.09-0.080.090.08
-0.01
-0.010.010.01
-1.48-1.40-0.22-0.30
0.180.080.06
-0.10-0.100.100.100.00
0.00-0.00-0.00-2.09-2.100.120.13
0.120.080.05
-0.030.010.03
-0.01-0.05
-0.070.050.07
-1.08-0.55-1.32-1.81
0.320.150.10
-0.05-0.050.050.050.01
0.01-0.01-0.01-1.04-1.060.200.21
0.240.150.10
-0.020.000.02
-0.00-0.02
-0.030.020.03
-0.61-0.35-0.63-0.87
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C12 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
11.584.112.42
-0.05-0.050.050.05
-0.01-0.010.010.01
-0.99-1.01-0.19-0.18
-0.20-0.13-0.08-0.13-0.130.130.13
-0.00-0.000.000.00
-2.50-2.48-0.04-0.06
0.270.080.05
-0.010.000.01
-0.00-0.05-0.060.050.06
-0.21-0.06-1.69-1.82
-0.31-0.21-0.13-0.09-0.090.090.09
-0.00-0.000.000.00
-1.72-1.68-0.07-0.10
0.470.130.09
-0.000.000.00
-0.00-0.02-0.020.020.020.050.08
-0.50-0.53
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C13 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
7.762.431.470.080.08
-0.08-0.080.080.08
-0.08-0.081.411.47
2.932.87
0.190.090.06
-0.14-0.140.140.140.00
-0.00-0.000.00
-2.78-2.76
0.020.00
0.170.060.040.00
-0.00-0.000.00
-0.10-0.090.100.090.090.04
-3.36-3.31
0.330.170.10
-0.11-0.110.110.11
-0.00-0.000.000.00
-2.17-2.16
0.020.00
0.280.100.070.00
-0.00-0.000.00
-0.08-0.080.080.080.050.01
-2.79-2.75
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 61/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
61
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C14 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
12.065.943.47
-0.01-0.02
0.010.02-0.03-0.030.030.03
-0.21-0.36-1.22-1.08
-0.09-0.15-0.09-0.13-0.13
0.130.130.00
-0.00-0.000.00
-2.58-2.560.020.00
0.260.110.070.02
-0.01
-0.020.01-0.08-0.060.080.060.730.37
-2.93-2.60
-0.13-0.24-0.14-0.09-0.09
0.090.090.00
-0.00-0.000.00
-1.84-1.820.020.01
0.420.160.110.01
-0.00
-0.010.00-0.03-0.030.030.030.370.20
-1.38-1.23
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C15 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
15.979.275.350.070.05
-0.07-0.05-0.04
-0.030.040.031.861.56
-1.69-1.42
-0.59-0.27-0.16-0.11-0.100.110.100.00
0.00-0.00-0.00-2.12-2.100.01
-0.00
0.450.480.280.04
-0.01-0.040.01
-0.09
-0.060.090.061.250.59
-3.38-2.78
-0.95-0.43-0.26-0.05-0.050.050.050.00
0.00-0.00-0.00-1.08-1.070.01
-0.01
0.710.750.450.02
-0.00-0.020.00
-0.04
-0.030.040.030.510.23
-1.45-1.20
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C16 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.651.651.02
-0.10-0.070.100.07
-0.00-0.010.000.01
-1.99-1.670.18
-0.11
0.190.090.06
-0.12-0.100.120.100.01
-0.00-0.010.00
-2.80-2.420.680.34
-0.11-0.02-0.02-0.040.010.04
-0.01-0.06-0.080.060.08
-1.29-0.63-1.65-2.25
0.350.170.12
-0.06-0.050.060.050.01
-0.00-0.010.00
-1.40-1.200.340.17
-0.14-0.01-0.01-0.030.010.03
-0.01-0.04-0.060.040.06
-0.96-0.49-1.17-1.60
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C17 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
13.484.912.90
-0.05-0.030.050.03
-0.01-0.010.010.01
-1.37-1.16
-0.02-0.21
-0.25-0.13-0.08-0.15-0.120.150.120.02
-0.00-0.020.00
-3.37-2.91
0.820.40
-0.07-0.01-0.01-0.010.000.01
-0.00-0.07-0.080.070.08
-0.32-0.12
-2.29-2.48
-0.37-0.18-0.11-0.11-0.090.110.090.01
-0.00-0.010.00
-2.33-2.01
0.570.28
-0.09-0.02-0.02-0.010.000.01
-0.00-0.05-0.050.050.05
-0.14-0.01
-1.50-1.62
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 62/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 62
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C18 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.382.551.550.100.08
-0.10-0.08-0.03-0.010.030.012.141.86
-1.07-0.81
0.210.090.05
-0.17-0.13
0.170.130.02
-0.00-0.020.00
-3.73-3.220.910.45
-0.08-0.04-0.020.00
-0.00
-0.000.00-0.08-0.080.080.080.080.04
-2.86-2.82
0.390.170.10
-0.13-0.10
0.130.100.01
-0.00-0.010.00
-2.92-2.520.720.35
-0.12-0.07-0.040.00
-0.00
-0.000.00-0.06-0.050.060.050.030.00
-1.97-1.95
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C19 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
13.254.732.80
-0.03-0.030.030.03
-0.01
-0.010.010.01
-1.05-0.980.02
-0.03
-0.17-0.10-0.06-0.15-0.120.150.120.02
-0.00-0.020.00
-3.41-2.950.820.40
-0.00-0.01-0.010.03
-0.01-0.030.01
-0.10
-0.080.100.080.880.43
-3.64-3.23
-0.25-0.13-0.07-0.11-0.080.110.080.01
-0.00-0.010.00
-2.39-2.070.570.27
-0.02-0.04-0.030.02
-0.00-0.020.00
-0.07
-0.050.070.050.610.30
-2.56-2.27
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C20 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
9.601.520.940.080.06
-0.08-0.06-0.02-0.010.020.012.351.99
-1.24-0.90
-0.05-0.01-0.01-0.12-0.100.120.100.01
-0.00-0.010.00
-2.78-2.410.690.34
0.11-0.09-0.050.05
-0.01-0.050.01
-0.11-0.080.110.081.680.83
-4.40-3.63
-0.040.02
-0.00-0.06-0.040.060.040.01
-0.00-0.010.00
-1.36-1.180.350.18
0.15-0.18-0.110.04
-0.01-0.040.01
-0.08-0.050.080.051.230.62
-3.14-2.60
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C21 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
5.610.930.58
-0.09-0.080.090.080.040.04
-0.04-0.04-1.48-1.38
1.521.42
0.170.090.06
-0.14-0.090.140.090.02
-0.00-0.020.00
-3.39-2.71
1.240.61
-0.08-0.05-0.04-0.030.010.03
-0.01-0.05-0.070.050.07
-1.13-0.57
-1.39-1.90
0.330.180.12
-0.07-0.040.070.040.01
-0.00-0.010.00
-1.69-1.35
0.610.31
-0.09-0.06-0.05-0.020.000.02
-0.00-0.03-0.040.030.04
-0.70-0.39
-0.74-1.02
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 63/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
63
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C22 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
8.792.431.45
-0.04-0.03
0.040.030.070.06
-0.07-0.06-1.43-1.252.172.01
-0.17-0.06-0.04-0.18-0.12
0.180.120.03
-0.00-0.030.00
-4.15-3.321.500.74
-0.13-0.03-0.02-0.010.00
0.01-0.00-0.06-0.070.060.07
-0.19-0.03-1.97-2.12
-0.22-0.05-0.04-0.13-0.08
0.130.080.02
-0.00-0.020.00
-2.94-2.351.040.51
-0.20-0.04-0.03-0.000.00
0.00-0.00-0.03-0.040.030.040.070.13
-0.97-1.03
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
C23 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+
Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
5.781.450.890.100.07
-0.10-0.070.02
0.04-0.02-0.042.391.940.490.91
0.150.060.04
-0.19-0.120.190.120.03
-0.00-0.030.00
-4.53-3.621.650.82
-0.18-0.06-0.040.00
-0.00-0.000.00
-0.07
-0.070.070.070.060.02
-2.47-2.44
0.310.140.09
-0.15-0.100.150.100.02
-0.00-0.020.00
-3.56-2.841.300.64
-0.29-0.11-0.070.00
-0.00-0.000.00
-0.04
-0.040.040.04
-0.01-0.02-1.33-1.32
0.000.000.000.00
-0.00-0.000.00
-0.00
0.000.00
-0.000.010.00
-0.01-0.00
C24 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
12.094.872.85
-0.04-0.010.040.010.050.04
-0.05-0.04-0.85-0.521.841.53
-0.16-0.10-0.06-0.18-0.110.180.110.03
-0.00-0.030.00
-4.23-3.381.530.76
-0.38-0.18-0.110.02
-0.01-0.020.01
-0.08-0.070.080.070.730.36
-3.05-2.70
-0.21-0.13-0.07-0.13-0.080.130.080.02
-0.00-0.020.00
-3.08-2.461.100.55
-0.64-0.31-0.190.01
-0.00-0.010.00
-0.04-0.030.040.030.370.18
-1.58-1.41
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
C25 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2
Sismo Y 1Sismo Y 2
6.991.951.160.060.06
-0.06-0.060.040.04
-0.04-0.040.820.88
1.641.59
-0.060.01
-0.00-0.14-0.090.140.090.02
-0.00-0.020.00
-3.42-2.73
1.240.61
-0.42-0.16-0.100.04
-0.01-0.040.01
-0.09-0.060.090.061.420.71
-3.70-3.05
-0.050.060.02
-0.07-0.050.070.050.01
-0.00-0.010.00
-1.74-1.39
0.620.30
-0.73-0.30-0.180.02
-0.00-0.020.00
-0.05-0.030.050.030.800.43
-1.99-1.65
0.000.000.000.00
-0.00-0.000.00
-0.000.000.00
-0.000.010.00
-0.01-0.00
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 64/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 64
Soporte HipótesisEsfuerzos en arranques
N(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
C26 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-
Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
3.521.250.740.250.28
-0.25-0.28-0.03-0.050.030.054.554.93
-0.83-1.18
-0.04-0.02-0.01-0.13-0.15
0.130.15-0.010.000.01
-0.00-2.44-2.65-0.37-0.18
-0.08-0.04-0.030.00
-0.00
-0.000.00-0.10-0.100.100.100.110.05
-3.60-3.54
-0.06-0.03-0.02-0.11-0.12
0.110.12-0.000.000.00
-0.00-1.98-2.15-0.27-0.12
-0.12-0.07-0.050.00
-0.00
-0.000.00-0.09-0.090.090.090.080.03
-3.18-3.13
0.000.000.000.00
-0.00
-0.000.00-0.000.000.00
-0.000.010.00
-0.01-0.00
5.- PÉSIMOS DE PILARES, PANTALLAS Y MUROS
5.1.- Pilares
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza N
(t)Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
C1PISO2 2.00/5.00 35x35
Pie G, Q, S 5.57 -2.01 -2.63 -1.78 1.23 Q 55.9 Cumple
Cabeza G, Q 3.98 0.28 1.57 -1.14 0.18 Q 23.4 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 5.57 -2.01 -2.63 -1.78 1.23 N,M 45.5 Cumple
Pie G, Q, S 9.81 -2.42 -1.12 -0.62 1.69 Q 42.8 Cumple
0.00 m G, Q 4.96 -0.20 -1.47 -1.14 0.18 N,M 16.4 Cumple
Cabeza G, Q, V 6.76 0.32 0.10 -0.12 0.32 N,M 5.6 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 9.84 -2.14 -1.50 -0.81 1.52 N,M 35.0 Cumple
Pie G 8.13 -0.14 -0.11 -0.14 0.29 N,M 6.0 Cumple
C2 CUBIERTA
5.00/6.20 35x35 Pie G, Q, S 0.94 0.65 2.10 2.99 -0.65 Q 72.9 Cumple
PISO2
Pie G, Q 1.11 0.68 1.38 2.32 -0.65 Q 45.2 Cumple
2.00/5.00 35x35
Cabeza G, Q, S 3.67 -2.87 -4.77 3.18 -2.07 Q 91.4 Cumple
Cabeza G, Q 6.64 -0.29 -2.06 1.11 -0.08 Q 21.1 Cumple
Cabeza G, Q, V 5.82 -0.21 -1.99 1.14 -0.05 Q 21.7 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 4.64 2.64 3.71 3.18 -2.07 N,M 53.6 Cumple
Pie G, S 3.16 0.64 2.37 2.00 -0.19 Q 47.6 Cumple
0.00 m G, Q, V 6.80 -0.18 1.06 1.14 -0.05 N,M 11.5 Cumple
Cabeza G, Q 10.98 0.53 0.01 -0.04 0.50 N,M 8.2 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 15.96 -2.56 -2.05 -1.71 1.70 N,M 39.0 Cumple
Pie G, Q 11.59 -0.29 -0.06 -0.04 0.50 N,M 8.0 CumpleC3
PISO2 2.00/5.00 35x35Pie G, Q, S 17.76 -3.63 -3.99 -2.70 2.40 Q 82.4 Cumple
Cabeza G, Q 21.14 1.88 2.51 -1.69 1.22 N,M 40.9 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 17.76 -3.63 -3.99 -2.70 2.40 N,M 69.5 Cumple
Pie G, S 11.19 -0.65 -2.59 -2.32 0.31 Q 52.6 Cumple
0.00 m G, Q 22.12 -1.44 -2.10 -1.69 1.22 N,M 33.5 Cumple
Cabeza G, Q 24.95 -0.35 -0.20 0.17 -0.33 N,M 18.1 Cumple
Cimentación -0.32/0.00 35x35 Pie G, Q, S 22.16 2.75 2.21 2.05 -1.81 N,M 46.0 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 65/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
65
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
Pie G, Q 25.56 0.20 0.07 0.17 -0.33 N,M 18.5 Cumple
C4PISO2 2.00/5.00 35x35
Cabeza G, Q, S 10.60 2.97 -3.83 2.33 2.65 Q 88.4 Cumple
Cabeza G, Q 11.74 1.55 -4.84 2.95 1.10 N,M 62.7 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 11.58 -4.16 2.44 2.33 2.65 N,M 63.7 Cumple
Pie G, Q, S 10.66 3.67 0.43 -0.27 -2.40 Q 61.6 Cumple
0.00 m G, Q 12.71 -1.42 3.12 2.95 1.10 N,M 43.7 Cumple
Cabeza G, Q 15.45 -0.29 0.90 -0.89 -0.25 N,M 14.2 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 15.72 -3.04 -1.81 -1.31 1.78 N,M 46.8 Cumple
Pie G, Q 16.05 0.11 -0.57 -0.89 -0.25 N,M 11.8 Cumple
C5PISO2 2.00/5.00 35x35
Pie G, Q, S 5.60 -2.54 -1.92 -1.35 1.47 Q 51.5 Cumple
Cabeza G, Q 4.97 -0.25 1.37 -0.98 -0.21 Q 19.7 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 5.60 -2.54 -1.92 -1.35 1.47 N,M 43.6 Cumple
Pie G, S 6.18 2.94 0.77 0.27 -2.44 Q 62.5 Cumple
0.00 m G, Q 5.95 0.33 -1.24 -0.98 -0.21 N,M 15.4 Cumple
Cabeza G, Q, V 8.68 0.03 0.20 -0.27 -0.01 N,M 6.4 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 6.95 -2.89 -0.97 -0.58 2.44 N,M 37.8 Cumple
Pie G 10.21 0.04 -0.15 -0.24 -0.01 N,M 7.5 Cumple
C6 CUBIERTA
5.00/6.20 35x35
Pie G, Q, S 1.07 -1.17 1.45 2.38 1.27 N,M 26.2 Cumple
PISO2
Pie G, Q, S 0.98 -0.59 1.77 2.67 0.45 Q 67.4 Cumple
Pie G, Q 1.20 -0.68 0.90 1.85 0.65 Q 37.2 Cumple
2.00/5.00 35x35
Cabeza G, Q, S 8.91 1.80 -5.00 3.40 1.22 N,M 67.9 Cumple
Cabeza G, Q, S 9.10 -0.47 -5.49 3.76 -0.48 Q 98.0 Cumple
Cabeza G, Q 11.57 0.97 -1.75 1.00 0.55 N,M 26.5 Cumple
Cabeza G, Q, V 9.89 0.77 -1.78 1.07 0.43 N,M 24.9 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, S 10.05 3.40 3.16 2.64 -2.40 N,M 63.8 Cumple
Pie G, S 8.95 3.06 1.62 1.40 -2.51 Q 69.7 Cumple
0.00 m G, Q, V 10.86 -0.39 1.08 1.07 0.43 N,M 15.1 Cumple
Cabeza G, Q, V 14.47 -0.21 -0.17 0.23 -0.21 N,M 10.6 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 13.52 3.11 1.64 1.43 -2.58 N,M 45.6 Cumple
Pie G, Q 17.49 0.17 0.06 0.11 -0.26 N,M 12.8 Cumple
C7
PISO2 2.00/5.00 35x35
Pie G, Q, S 15.39 -2.99 -2.95 -1.96 1.57 Q 58.4 Cumple
Pie G, Q, S 14.99 -0.43 -4.10 -2.64 0.06 Q 66.4 Cumple
Cabeza G, Q 19.10 -1.00 1.48 -1.05 -0.58 N,M 24.7 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 15.39 -2.99 -2.95 -1.96 1.57 N,M 57.0 CumplePie G, S 11.15 -3.35 -1.77 -1.63 2.80 Q 74.3 Cumple
0.00 m G, Q 20.06 0.56 -1.32 -1.05 -0.58 N,M 20.5 Cumple
Cabeza G, Q, V 19.78 0.23 0.20 -0.27 0.22 N,M 14.5 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 17.69 -3.40 -1.79 -1.65 2.88 N,M 50.1 Cumple
Pie G, Q 24.70 -0.17 -0.07 -0.10 0.28 N,M 18.1 Cumple
C8PISO2 2.00/5.00 35x35
Pie G, Q, S 8.35 3.62 2.83 2.19 -2.41 Q 79.1 Cumple
Cabeza G, Q 7.44 -1.38 -3.08 1.96 -0.79 N,M 41.4 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 66/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 66
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 8.35 3.62 2.83 2.19 -2.41 N,M 59.7 Cumple
Pie G, S 10.34 3.60 0.26 0.07 -2.27 Q 55.5 Cumple
0.00 m G, Q 8.42 0.73 2.16 1.96 -0.79 N,M 26.7 CumpleCabeza G, Q 11.01 -0.04 0.27 -0.26 0.00 N,M 8.0 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 3.51 -3.60 -0.39 -0.26 2.21 N,M 42.4 Cumple
Pie G, Q 11.62 -0.03 -0.17 -0.26 0.00 N,M 8.4 Cumple
C9PISO2 2.00/5.00 35x35
Pie G, Q, S 5.73 -2.59 -1.72 -1.27 1.58 Q 52.1 Cumple
Cabeza G, Q 5.26 0.26 1.38 -0.94 0.14 Q 18.8 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 5.73 -2.59 -1.72 -1.27 1.58 N,M 42.2 Cumple
Pie G, Q, S 9.24 -2.68 -0.84 -0.57 2.11 Q 53.3 Cumple
0.00 m G, Q 6.23 -0.16 -1.13 -0.94 0.14 N,M 13.1 Cumple
Cabeza G, Q, V 9.07 0.18 0.27 -0.31 0.16 N,M 6.8 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 10.11 -1.63 -2.02 -1.20 1.31 N,M 34.9 Cumple
Pie G 10.73 -0.05 -0.16 -0.28 0.14 N,M 7.9 Cumple
C10
PISO2 2.00/5.00 35x35
Pie G, Q, S 14.19 0.94 3.83 2.32 -0.58 Q 59.0 Cumple
Pie G, Q 18.23 0.48 0.78 0.58 -0.13 N,M 15.5 Cumple
Cabeza G, Q, V 14.26 -0.37 -0.81 0.62 -0.11 N,M 13.4 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 14.19 0.94 3.83 2.32 -0.58 N,M 46.4 Cumple
Pie G, S 9.17 0.98 3.26 3.07 -0.75 Q 77.2 Cumple
Pie G, Q 21.88 0.23 0.21 0.32 -0.36 N,M 16.0 Cumple
Cabeza G, Q, V 17.74 -0.32 -0.35 0.42 -0.32 N,M 13.0 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 14.94 1.04 3.31 3.16 -0.84 N,M 42.3 Cumple
Pie G, Q 21.88 0.23 0.21 0.32 -0.36 N,M 16.0 Cumple
C11
PISO2 2.00/5.00 35x35
Pie G, Q, S 5.95 -1.96 -2.75 -1.80 1.36 Q 58.0 Cumple
Cabeza G 4.71 1.34 1.26 -0.88 0.90 Q 25.2 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 5.95 -1.96 -2.75 -1.80 1.36 N,M 46.0 Cumple
Pie G, Q, S 10.42 -1.74 -2.40 -1.59 1.32 Q 47.0 Cumple
0.00 m G 5.84 -1.06 -1.07 -0.88 0.90 N,M 20.5 Cumple
Cabeza G, Q 9.02 0.70 0.79 -0.73 0.62 N,M 14.5 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 10.42 -1.74 -2.40 -1.59 1.32 N,M 39.6 Cumple
Pie G, Q 9.63 -0.33 -0.41 -0.73 0.62 N,M 8.6 Cumple
C12 CUBIERTA
5.00/6.20 35x35Pie G, Q, S 2.31 -1.98 -2.73 -1.86 3.65 N,M 50.9 Cumple
PISO2
Cabeza G 1.85 1.32 -0.91 -0.17 1.50 Q 31.8 Cumple
2.00/5.00 35x35Cabeza G, Q, S 14.78 2.52 4.67 -3.15 1.71 Q 83.1 CumpleCabeza G, S 10.39 2.33 4.43 -3.07 1.57 Q 83.4 Cumple
Cabeza G, Q 16.81 0.67 0.79 -0.29 0.52 N,M 15.7 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 15.74 -2.02 -3.69 -3.15 1.71 N,M 52.2 Cumple
Pie G, S 13.08 0.40 2.81 2.20 0.44 Q 50.1 Cumple
Cabeza G, Q 22.09 0.92 -0.83 0.82 0.86 N,M 19.7 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 19.09 -0.93 2.90 2.34 1.00 N,M 36.5 Cumple
Pie G, Q 22.70 -0.50 0.53 0.82 0.86 N,M 16.5 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 67/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
67
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
C13PISO2 2.00/5.00 35x35
Pie G, Q, S 7.38 -4.07 1.27 0.94 2.42 Q 62.9 Cumple
Cabeza G, Q 8.02 0.37 -0.91 0.56 0.39 N,M 12.4 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 7.38 -4.07 1.27 0.94 2.42 N,M 50.9 Cumple
Pie G, Q, S 9.61 -3.63 -1.19 -1.28 3.27 Q 79.8 Cumple
Cabeza G, Q 13.97 0.59 0.83 -0.76 0.57 N,M 14.5 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 5.82 -3.54 -1.07 -1.08 3.12 N,M 44.4 Cumple
Pie G, Q 14.58 -0.35 -0.43 -0.76 0.57 N,M 11.0 Cumple
C14
PISO2 2.00/5.00 35x35
Pie G, Q, S 19.05 -3.25 -1.75 -1.43 1.79 N,M 48.5 Cumple
Pie G, Q, S 18.94 -1.16 -3.57 -2.50 0.63 Q 56.3 Cumple
Cabeza G, Q 20.71 0.54 2.13 -1.23 0.37 N,M 28.0 Cumple
PISO1 0.00/2.00 35x35
Pie G, Q, S 23.50 -2.09 2.92 2.35 1.54 N,M 48.8 Cumple
Pie G, S 17.36 -3.48 1.01 0.90 2.02 Q 50.1 Cumple
0.00 m G, Q 21.68 -0.82 -1.23 -1.23 0.37 N,M 22.0 Cumple
Cabeza G, Q 26.55 0.88 -0.66 0.66 0.88 N,M 20.9 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 23.50 -2.09 2.92 2.35 1.54 N,M 48.8 Cumple
Pie G, Q 27.15 -0.57 0.43 0.66 0.88 N,M 19.9 Cumple
C15PISO2 2.00/5.00 35x35
Cabeza G, Q, S 27.67 -5.83 3.63 -2.13 -4.04 Q 98.4 Cumple
Cabeza G, Q 34.29 -4.35 3.78 -2.05 -2.21 N,M 79.0 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 28.64 5.32 -2.25 -2.13 -4.04 N,M 74.0 Cumple
Pie G, S 24.97 -4.58 1.42 1.58 2.92 Q 69.3 Cumple
Cabeza G, Q 38.23 2.50 -2.14 2.08 2.46 N,M 46.4 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 35.21 -5.00 1.76 2.13 3.58 N,M 67.3 Cumple
Pie G, Q 38.84 -1.56 1.29 2.08 2.46 N,M 33.9 Cumple
C16
PISO2 2.00/5.00 35x35
Pie G, S 6.99 -1.29 -2.71 -1.70 0.78 N,M 38.7 Cumple
Pie G, Q, S 9.29 -0.24 -3.22 -2.04 0.09 Q 52.4 Cumple
Cabeza G 8.06 -0.24 0.84 -0.54 -0.26 N,M 11.2 Cumple
PISO1 0.00/2.00 35x35
Pie G, Q, S 14.81 -1.62 -2.96 -1.98 1.12 Q 49.1 Cumple
Pie G, Q, S 14.92 -0.63 -3.37 -2.19 0.42 Q 54.0 Cumple
Cabeza G, Q 13.39 -0.17 0.92 -0.81 -0.21 N,M 13.0 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 14.81 -1.62 -2.96 -1.98 1.12 N,M 44.2 Cumple
Pie G 14.43 0.18 -0.39 -0.73 -0.22 N,M 10.6 Cumple
C17 CUBIERTA
5.00/6.20 35x35Pie G, Q, S 3.73 -2.40 -4.11 -3.15 3.42 N,M 70.1 Cumple
PISO2
Pie G, Q 3.27 0.10 -1.92 -1.10 0.07 N,M 24.5 Cumple
2.00/5.00 35x35
Cabeza G, Q, S 17.28 -0.45 6.63 -4.44 -0.29 N,M 66.2 Cumple
Pie G, Q, S 18.23 0.52 -5.19 -4.44 -0.29 Q 99.5 Cumple
Cabeza G, Q 19.48 -0.75 1.14 -0.41 -0.47 N,M 18.5 Cumple
Cabeza G, Q, V 17.00 -0.62 1.15 -0.49 -0.39 N,M 17.1 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 17.63 2.13 4.59 3.23 -1.85 N,M 56.6 Cumple
Pie G, S 15.19 -0.29 3.95 2.99 0.22 Q 67.6 Cumple
Pie G, Q 26.71 0.11 0.58 0.84 -0.16 N,M 18.5 Cumple
Cabeza G, Q, V 22.86 -0.13 -0.71 0.82 -0.15 N,M 15.8 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 68/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 68
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
Cimentación -0.32/0.00 35x35Pie G, Q, S 22.16 -0.26 4.10 3.21 0.18 N,M 43.2 Cumple
Pie G, Q 26.71 0.11 0.58 0.84 -0.16 N,M 18.5 Cumple
C18 PISO2 2.00/5.00 35x35 Pie G, Q, S 9.50 -1.02 4.82 3.07 0.58 Q 80.2 CumpleCabeza G, Q 8.29 -0.21 -1.09 0.76 -0.07 N,M 13.6 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 9.50 -1.02 4.82 3.07 0.58 N,M 59.6 Cumple
Pie G, Q, S 11.43 1.09 -4.38 -3.85 -0.87 Q 97.8 Cumple
Cabeza G, Q 14.99 -0.31 0.94 -0.83 -0.29 N,M 14.3 Cumple
Cabeza G, Q, V 13.19 -0.26 0.85 -0.85 -0.25 N,M 12.8 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 7.38 1.04 -4.27 -3.64 -0.79 N,M 54.5 Cumple
Pie G, Q 15.59 0.17 -0.44 -0.83 -0.29 N,M 11.4 Cumple
C19
PISO2 2.00/5.00 35x35
Pie G, Q, S 17.51 4.38 -2.47 -1.85 -2.76 Q 72.7 Cumple
Pie G, S 12.51 4.31 -2.30 -1.66 -2.69 Q 78.1 Cumple
Cabeza G, Q 18.24 -0.57 1.44 -0.75 -0.27 N,M 21.1 Cumple
Cabeza G, Q, V 15.96 -0.53 1.32 -0.74 -0.28 N,M 19.2 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 17.51 4.38 -2.47 -1.85 -2.76 N,M 65.4 Cumple
Pie G, S 15.13 -1.95 3.90 2.90 1.32 Q 73.8 Cumple
Pie G, Q 26.06 0.04 0.41 0.57 -0.12 N,M 19.1 Cumple
Cabeza G, Q, V 22.34 -0.11 -0.48 0.60 -0.07 N,M 16.4 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 22.64 -3.88 2.19 1.77 2.65 N,M 58.9 Cumple
Pie G, Q 26.06 0.04 0.41 0.57 -0.12 N,M 19.1 Cumple
C20
PISO2 2.00/5.00 35x35
Pie G, Q, S 10.00 -4.68 3.02 2.06 2.51 N,M 75.4 Cumple
Pie G, S 7.77 5.21 -0.20 0.16 -3.31 Q 86.5 Cumple
Cabeza G 9.14 -0.94 -1.64 1.25 -0.49 N,M 24.9 Cumple
Cabeza G, Q 8.45 -0.63 -1.71 1.31 -0.27 Q 24.5 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 10.00 -4.68 3.02 2.06 2.51 N,M 75.4 Cumple
Pie G, S 8.06 4.89 -1.47 -0.74 -3.53 Q 93.3 Cumple
0.00 m G 10.25 0.36 1.65 1.25 -0.49 N,M 20.3 Cumple
Cabeza G, Q 14.24 -0.28 0.04 0.03 -0.20 N,M 10.4 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 8.06 4.89 -1.47 -0.74 -3.53 N,M 64.6 Cumple
Pie G 15.56 -0.03 0.08 0.03 -0.04 N,M 11.4 Cumple
C21PISO2 2.00/5.00 35x35
Pie G, Q, S 6.02 0.76 -3.72 -2.38 -0.66 Q 62.8 Cumple
Cabeza G 4.43 -1.20 0.83 -0.48 -0.89 Q 19.9 Cumple
PISO1 0.00/2.00 35x35
Pie G, S 7.82 -0.60 -3.99 -2.34 0.34 N,M 47.4 Cumple
Pie G, Q, S 10.07 -0.54 -4.09 -2.55 0.27 Q 66.3 Cumple
0.00 m G 5.57 1.17 -0.45 -0.48 -0.89 N,M 15.8 CumpleCabeza G, Q 8.17 -0.21 0.94 -0.81 -0.26 N,M 12.1 Cumple
Cimentación -0.32/0.00 35x35Pie G, S 7.82 -0.60 -3.99 -2.34 0.34 N,M 47.4 Cumple
Pie G, Q 8.77 0.21 -0.40 -0.81 -0.26 N,M 7.5 Cumple
C22 CUBIERTA
5.00/6.20 35x35Pie G, Q, S 2.74 -1.72 -3.55 -2.56 1.32 Q 72.2 Cumple
PISO2 Cabeza G 2.15 -1.39 -0.88 -0.01 -1.62 Q 34.1 Cumple
2.00/5.00 35x35 Cabeza G, Q, S 8.50 -2.09 -7.24 5.35 -1.14 N,M 80.7 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 69/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
69
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
Pie G, Q, S 9.48 0.98 7.11 5.35 -1.14 N,M 70.8 Cumple
Cabeza G, Q 10.29 -1.52 -0.64 0.63 -0.94 N,M 18.9 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 9.48 0.98 7.11 5.35 -1.14 N,M 70.8 CumplePie G, Q, S 12.10 -0.20 4.89 3.60 0.06 Q 84.4 Cumple
0.00 m G, Q 11.27 1.00 1.06 0.63 -0.94 N,M 17.7 Cumple
Cabeza G, Q, V 13.53 -0.30 -0.31 0.47 -0.31 N,M 9.4 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 12.10 -0.20 4.89 3.60 0.06 N,M 48.7 Cumple
Pie G, Q 15.78 0.23 0.34 0.39 -0.34 N,M 10.9 Cumple
C23
PISO2 2.00/5.00 35x35
Pie G, Q, S 6.17 -0.38 5.62 3.43 0.13 Q 90.4 Cumple
Pie G, Q 5.49 0.48 0.85 0.60 -0.37 N,M 13.0 Cumple
Cabeza G, Q, V 4.08 -0.44 -0.75 0.61 -0.33 N,M 11.5 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 6.17 -0.38 5.62 3.43 0.13 N,M 58.6 Cumple
Cabeza G, Q, S 6.28 -0.38 2.20 -4.54 -0.90 Q 92.0 Cumple
Cabeza G, Q 9.49 -0.62 0.82 -0.69 -0.59 N,M 12.7 Cumple
Cabeza G, Q, V 8.41 -0.53 0.75 -0.74 -0.51 N,M 11.4 Cumple
Cimentación -0.37/0.00 35x35Pie G, S 4.27 1.01 -5.22 -4.36 -0.75 N,M 56.2 Cumple
Pie G, Q, V 9.02 0.31 -0.47 -0.74 -0.51 N,M 8.1 Cumple
C24
PISO2 2.00/5.00 35x35
Pie G, Q, S 16.77 -2.48 4.16 2.03 1.77 N,M 63.5 Cumple
Pie G, Q, S 18.02 0.74 -4.76 -3.13 -0.07 Q 78.2 Cumple
Cabeza G, Q 19.03 1.70 1.43 -0.65 1.01 N,M 30.4 Cumple
PISO1 0.00/2.00 35x35
Pie G, Q, S 23.18 2.37 -4.35 -2.97 -2.08 Q 72.5 Cumple
Pie G, Q, S 20.37 -0.92 5.04 3.84 -0.39 Q 94.3 Cumple
Cabeza G, Q 24.30 -1.55 -0.44 0.52 -1.45 N,M 23.2 Cumple
Cimentación -0.32/0.00 35x35
Pie G, Q, S 23.18 2.37 -4.35 -2.97 -2.08 N,M 64.9 Cumple
Pie G, Q 24.91 0.84 0.41 0.52 -1.45 N,M 18.8 Cumple
C25
PISO2 2.00/5.00 35x35
Pie G, Q, S 7.52 -4.79 3.78 2.48 3.09 N,M 80.1 Cumple
Pie G, Q, S 8.21 -3.26 5.20 3.34 2.19 Q 98.7 Cumple
Cabeza G, Q 8.21 1.82 -1.85 1.41 1.17 Q 33.8 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, Q, S 7.52 -4.79 3.78 2.48 3.09 N,M 80.1 Cumple
Pie G, Q, S 12.70 4.88 -2.20 -1.17 -3.56 Q 90.1 Cumple
0.00 m G, Q 9.19 -1.32 1.93 1.41 1.17 N,M 29.9 Cumple
Cabeza G, Q 11.98 -1.66 0.16 -0.06 -1.53 N,M 18.8 Cumple
Cimentación -0.32/0.00 35x35Pie G, Q, S 12.70 4.88 -2.20 -1.17 -3.56 N,M 65.3 Cumple
Pie G, Q 12.58 0.86 0.06 -0.06 -1.53 N,M 11.7 Cumple
C26PISO2 2.00/5.00 35x35
Pie G, S 2.84 3.60 1.29 0.76 -2.13 Q 59.8 CumplePie G, Q, V 3.51 -0.09 0.29 0.16 0.02 N,M 4.0 Cumple
Cabeza G, Q, V 2.56 0.03 -0.13 0.16 0.02 N,M 2.1 Cumple
PISO1 0.00/2.00 35x35
0.00 m G, S 2.84 3.60 1.29 0.76 -2.13 N,M 50.5 Cumple
Pie G, Q, S 6.62 3.72 1.19 0.99 -3.41 Q 89.4 Cumple
Cabeza G, Q 6.30 -0.33 -0.13 0.14 -0.31 N,M 5.6 Cumple
Cabeza G, Q, V 5.45 -0.32 -0.11 0.12 -0.35 N,M 5.0 Cumple
Cimentación -0.32/0.00 35x35 Pie G, S 4.82 3.67 1.16 0.95 -3.33 N,M 49.5 Cumple
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 70/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 70
Resumen de las comprobaciones
Pilares PlantaTramo(m)
Dimensión PosiciónEsfuerzos pésimos
PésimaAprov.(%)
EstadoNaturaleza
N(t)
Mxx(t·m)
Myy(t·m)
Qx(t)
Qy(t)
Pie G, Q, V 6.36 0.16 0.23 0.24 -0.26 N,M 5.1 Cumple
Notas:N,M: Estado límite de agotamiento frente a solicitaciones normales
Q: Estado límite de agotamiento frente a cortante
6.- LISTADO DE MEDICIÓN DE PILARES
Resumen de medición - PISO1
Pilares Dimensiones(cm)
Encofrado(m²)
Hormigónf'c=210(m³)
ArmadurasGrado 60 (Latinoamérica)
Cuantía(kg/m³)
Longitudinal Estribos Total+10 %(kg)
Ø1/2"(kg)
Ø3/4"(kg)
Ø5/8"(kg)
Ø1/2"(kg)
Ø3/8"(kg)
C1, C4, C5, C6, C7, C9, C10, C11, C14, C15, C16, C18, C19, C20, C21, C24 y C26 35x35 39.27 3.40 557.6 - - 1351.5 - 2100.0 561.50
C2, C17 y C22 35x35 6.93 0.60 - 83.1 54.3 - 87.6 247.5 375.00
C3, C8, C12, C13 y C25 35x35 11.55 1.00 - - 181.0 - 146.0 359.7 327.00
C23 35x35 2.31 0.20 - 25.5 16.9 - 29.2 78.8 358.00
Total 60.06 5.20 557.6 108.6 252.2 1351.5 262.8 2786.0 487.06
Resumen de medición - PISO2
PilaresDimensiones
(cm)Encofrado
(m²)
Hormigónf'c=210
(m³)
ArmadurasGrado 60 (Latinoamérica)
Cuantía(kg/m³)
Longitudinal Estribos Total+10 %(kg)
Ø1/2"(kg)
Ø3/4"(kg)
Ø5/8"(kg)
Ø1/2"(kg)
Ø3/8"(kg)
C1, C4, C5, C9, C10, C11, C14, C15, C16, C21 y C24 35x35 40.81 3.52 435.6 - - 1424.5 - 2046.1 528.44
C2 y C22 35x35 10.78 0.94 31.8 69.0 46.6 120.2 86.6 389.6 376.81
C3, C8 y C25 35x35 11.13 0.96 - - 129.3 - 129.9 285.1 270.00
C6 35x35 5.39 0.47 63.9 - - 188.4 - 277.5 536.81
C7, C18, C19, C20 y C26 35x35 18.20 1.60 198.0 - - 633.0 - 914.1 519.38
C12 35x35 5.32 0.47 15.9 - 46.7 60.1 42.1 181.3 350.64
C13 35x35 3.64 0.32 - - 43.1 - 42.1 93.7 266.25
C17 35x35 5.32 0.47 15.9 34.5 23.3 60.1 42.1 193.5 374.26
C23 35x35 3.71 0.32 35.3 - - 129.5 - 181.3 515.00
Total 104.30 9.07 796.4 103.5 289.0 2615.8 342.8 4562.2 457.28
7.- SUMATORIO DE ESFUERZOS DE PILARES, PANTALLAS Y MUROS POR HIPÓTESIS Y PLANTA
Sólo se tienen en cuenta los esfuerzos de pilares, muros y pantallas, por lo que si la obra tiene vigas con vinculación exterior, vigas inclinadas,diagonales o estructuras 3D integradas, los esfuerzos de dichos elementos no se muestran en el siguiente listado.
Este listado es de utilidad para conocer las cargas actuantes por encima de la cota de la base de los soportes sobre una planta, por lo quepara casos tales como pilares apeados traccionados, los esfuerzos de dichos pilares tendrán la influencia no sólo de las cargas por encima sinotambién la de las cargas que recibe de plantas inferiores.
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 71/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
71
7.1.- Resumido
Valores referidos al origen (X=0.00, Y=0.00)
PlantaCota(m)
HipótesisN(t)
Mx(t·m)
My(t·m)
Qx(t)
Qy(t)
T(t·m)
PISO2 3.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+
Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
0.31-0.00-0.000.00
0.00-0.00-0.000.000.00
-0.00-0.00-0.000.000.00
-0.00
2.16-0.00-0.000.10
0.10-0.10-0.10-0.000.000.00
-0.000.010.010.00
-0.00
4.97-0.00-0.000.00
-0.00-0.000.000.060.06
-0.06-0.060.000.000.010.01
0.000.000.000.50
0.50-0.50-0.50-0.000.000.00
-0.000.040.04
-0.00-0.00
-0.00-0.00-0.00-0.00
-0.000.000.000.290.29
-0.29-0.29-0.00-0.000.040.04
-0.00-0.000.00
-8.12
-8.098.128.092.032.01
-2.03-2.01-0.77-0.660.350.27
PISO1 0.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
154.7768.2639.00-0.00-0.000.000.00
-0.00-0.000.000.00
-0.00-0.00-0.00-0.00
1781.8862.15492.66
7.427.42
-7.42-7.420.000.00
-0.00-0.00
138.85138.72
-1.06-0.95
2698.41043.9596.52
0.000.00
-0.00-0.004.254.25
-4.25-4.25-4.60-4.10
138.63138.21
0.000.000.002.242.24
-2.24-2.24-0.000.000.00
-0.0044.6544.65-0.00-0.00
-0.000.000.000.00
-0.00-0.000.001.281.28
-1.28-1.280.00
-0.0044.6544.65
-0.00-0.00-0.00
-42.97-33.7242.9733.7216.8011.95
-16.80-11.95-954.5-830.9661.29548.72
Cimentación -2.00 Peso propioCargas muertasSobrecarga de usoViento +X exc.+Viento +X exc.-Viento -X exc.+Viento -X exc.-Viento +Y exc.+Viento +Y exc.-
Viento -Y exc.+Viento -Y exc.-Sismo X 1Sismo X 2Sismo Y 1Sismo Y 2
220.1485.2150.30-0.00-0.000.000.00
-0.00-0.00
0.000.00-0.00-0.00-0.00-0.00
2445.91034.6607.6411.9011.90
-11.90-11.90
0.000.00
-0.00-0.00228.15228.02
-1.06-0.95
3833.81342.5795.59
0.000.00
-0.00-0.006.816.81
-6.81-6.81-4.60-4.10
227.93227.51
0.000.000.002.242.24
-2.24-2.24-0.000.00
0.00-0.0044.6544.65-0.00-0.00
0.000.000.000.00
-0.00-0.000.001.281.28
-1.28-1.280.00
-0.0044.6544.65
-0.00-0.00-0.00
-42.97-33.7242.9733.7216.8011.95
-16.80-11.95-954.5-830.9661.29548.72
8.4.ARMADO DE VIGAS
1.- PISO2
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 72/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 72
1.1.- Pórtico 1
Pórtico 1 Tramo: V-201 Tramo: V-202
Sección 20x40 25x40
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
Situacionespersistentes o
transitorias
Momento mín. [t·m] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Momento máx. [t·m] 0.49 0.74 0.93 1.64 1.69 1.22
x [m] 0.35 0.70 1.17 1.10 1.72 2.97
Cortante mín. [t] -- -- -- -- -0.53 -1.21 x [m] -- -- -- -- 2.66 4.06
Cortante máx. [t] 0.98 0.73 0.51 0.76 0.09 --
x [m] 0.00 0.45 0.82 0.00 1.41 --
Torsor mín. [t] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Torsor máx. [t] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Situaciones sísmicasMomento mín. [t·m] -- -- -- -- -- --
x [m] -- -- -- -- -- --
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 73/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
73
Pórtico 1 Tramo: V-201 Tramo: V-202
Sección 20x40 25x40
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
Momento máx. [t·m] 0.51 0.79 1.07 1.65 1.67 1.16
x [m] 0.35 0.70 1.17 1.10 1.41 2.97
Cortante mín. [t] -- -- -- -- -0.53 -1.14
x [m] -- -- -- -- 2.66 4.06
Cortante máx. [t] 1.02 0.81 0.63 0.75 0.15 --
x [m] 0.00 0.45 0.82 0.00 1.41 --
Torsor mín. [t] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Torsor máx. [t] -- -- -- -- -- --
x [m] -- -- -- -- -- --
Área Sup. [cm²]Real 3.98 5.34 6.01 7.31 3.98 3.98
Nec. 2.94 2.94 2.94 2.94 2.94 2.94
Área Inf. [cm²]Real 3.98 3.98 3.98 3.98 3.98 3.98
Nec. 2.94 2.94 5.88 5.88 2.94 2.94
Área Transv. [cm²/m]Real 17.83 17.83 17.83 17.83 8.39 17.83
Nec. 8.59 8.59 8.59 2.92 2.12 2.92
F. Activa 3.11 mm, L/1789 (L: 5.56 m) 3.69 mm, L/1506 (L: 5.56 m)
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 74/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85 74
1.2.- Pórtico 2
Pórtico 2 Tramo: V-203 Tramo: V-204 Tramo: V-205
Sección 30x35 30x35 30x35
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
Situacionespersistentes o
transitorias
Momento mín. [t·m] -0.18 -- -2.22 -2.02 -0.43 -- -- -- -1.30
x [m] 0.00 -- 6.02 0.00 0.48 -- -- -- 2.08
Momento máx. [t·m] 1.34 1.37 0.64 -- 0.75 2.02 2.10 0.81 --
x [m] 2.01 2.34 4.01 -- 0.85 1.38 0.00 0.96 --
Cortante mín. [t] -- -0.89 -1.96 -- -- -- -1.45 -1.75 -2.20
x [m] -- 4.01 6.02 -- -- -- 0.68 1.24 2.08
Cortante máx. [t] 1.27 0.20 -- 3.54 3.11 2.65 -- -- --
x [m] 0.00 2.01 -- 0.00 0.48 0.98 -- -- --
Torsor mín. [t] -- -- -- -- -- -- -- -- --
x [m] -- -- -- -- -- -- -- -- --
Torsor máx. [t] -- -- -- -- -- -- -- -- --
x [m] -- -- -- -- -- -- -- -- --
Situaciones sísmicas
Momento mín. [t·m] -2.36 -0.35 -4.21 -4.69 -2.43 -0.69 -- -0.77 -3.63
x [m] 0.00 4.01 6.02 0.00 0.48 0.98 -- 1.24 2.08
Momento máx. [t·m] 2.30 1.94 1.32 1.79 2.12 2.45 3.09 1.31 1.65
x [m] 0.67 2.01 4.01 0.35 0.85 1.38 0.00 1.24 2.08
Cortante mín. [t] -0.64 -1.53 -2.48 -- -- -- -3.07 -3.34 -3.73
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 75/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
75
Pórtico 2 Tramo: V-203 Tramo: V-204 Tramo: V-205
Sección 30x35 30x35 30x35
Zona 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L 1/3L 2/3L 3/3L
x [m] 2.01 4.01 6.02 -- -- -- 0.68 1.24 2.08
Cortante máx. [t] 1.86 0.92 0.20 4.71 4.27 3.82 1.06 0.75 0.56
x [m] 0.00 2.01 4.01 0.00 0.48 0.98 0.00 0.96 1.52
Torsor mín. [t] -- -- -- -- -- -- -- -- --
x [m] -- -- -- -- -- -- -- -- --
Torsor máx. [t] -- -- -- -- -- -- -- -- --
x [m] -- -- -- -- -- -- -- -- --
Área Sup. [cm²]Real 5.25 3.98 7.94 8.22 8.50 8.32 6.26 4.44 6.80
Nec. 3.12 3.12 4.05 4.57 3.43 3.12 3.12 3.12 3.49
Área Inf. [cm²]Real 3.98 3.98 5.25 4.90 4.07 4.80 5.06 3.98 3.98
Nec. 3.12 3.12 6.24 6.24 3.12 6.24 6.24 3.12 5.88
Área Transv. [cm²/m]Real 20.37 10.19 20.37 20.37 20.37 20.37 20.37 20.37 20.37
Nec. 2.84 2.55 2.83 10.85 10.87 10.85 6.93 2.55 6.93
F. Activa 1.23 mm, L/4572 (L:
5.61 m) 0.64 mm, L/5829 (L:
3.75 m) 0.69 mm, L/5455 (L:
3.75 m)
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 76/89
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 77/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 77
8.5.DISEÑO DE CIMENTACIÓN
1.1.- Descripción
Referencias Geometría Armado
C1, C4, C5, C9,C11, C14, C16,C19, C20, C24
Zapata rectangular excéntricaAncho inicial X: 70.0 cmAncho inicial Y: 70.0 cm
Ancho final X: 70.0 cmAncho final Y: 70.0 cmAncho zapata X: 140.0 cmAncho zapata Y: 140.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27
Inf Y: 5Ø5/8"c/27
C8 Zapata rectangular excéntricaAncho inicial X: 95.0 cmAncho inicial Y: 95.0 cmAncho final X: 95.0 cmAncho final Y: 95.0 cmAncho zapata X: 190.0 cmAncho zapata Y: 190.0 cmCanto: 40.0 cm
Sup X: 7Ø5/8"c/27Sup Y: 7Ø5/8"c/27Inf X: 7Ø5/8"c/27Inf Y: 7Ø5/8"c/27
C12 Zapata rectangular excéntricaAncho inicial X: 70.0 cmAncho inicial Y: 70.0 cmAncho final X: 70.0 cmAncho final Y: 70.0 cmAncho zapata X: 140.0 cmAncho zapata Y: 140.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
C13 Zapata rectangular excéntricaAncho inicial X: 75.0 cmAncho inicial Y: 75.0 cmAncho final X: 75.0 cmAncho final Y: 75.0 cmAncho zapata X: 150.0 cmAncho zapata Y: 150.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
C15 Zapata rectangular excéntricaAncho inicial X: 72.5 cmAncho inicial Y: 72.5 cmAncho final X: 72.5 cmAncho final Y: 72.5 cmAncho zapata X: 145.0 cm
Ancho zapata Y: 145.0 cmCanto: 40.0 cm
X: 5Ø5/8"c/27Y: 5Ø5/8"c/27
C17 Zapata rectangular excéntricaAncho inicial X: 70.0 cmAncho inicial Y: 70.0 cmAncho final X: 70.0 cmAncho final Y: 70.0 cmAncho zapata X: 140.0 cmAncho zapata Y: 140.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
C18 Zapata rectangular excéntricaAncho inicial X: 67.5 cmAncho inicial Y: 67.5 cmAncho final X: 67.5 cmAncho final Y: 67.5 cmAncho zapata X: 135.0 cmAncho zapata Y: 135.0 cm
Canto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
C21 Zapata rectangular excéntricaAncho inicial X: 72.5 cmAncho inicial Y: 72.5 cmAncho final X: 72.5 cmAncho final Y: 72.5 cmAncho zapata X: 145.0 cmAncho zapata Y: 145.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 78/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 78
Referencias Geometría Armado
C22 Zapata rectangular excéntricaAncho inicial X: 75.0 cmAncho inicial Y: 75.0 cmAncho final X: 75.0 cmAncho final Y: 75.0 cmAncho zapata X: 150.0 cmAncho zapata Y: 150.0 cmCanto: 40.0 cm
Sup X: 5Ø5/8"c/27Sup Y: 5Ø5/8"c/27Inf X: 5Ø5/8"c/27Inf Y: 5Ø5/8"c/27
C23 Zapata rectangular excéntricaAncho inicial X: 102.5 cmAncho inicial Y: 102.5 cmAncho final X: 102.5 cmAncho final Y: 102.5 cmAncho zapata X: 205.0 cmAncho zapata Y: 205.0 cmCanto: 45.0 cm
Sup X: 8Ø5/8"c/24Sup Y: 8Ø5/8"c/24Inf X: 8Ø5/8"c/24Inf Y: 8Ø5/8"c/24
C25 Zapata rectangular excéntricaAncho inicial X: 80.0 cmAncho inicial Y: 80.0 cmAncho final X: 80.0 cmAncho final Y: 80.0 cmAncho zapata X: 160.0 cmAncho zapata Y: 160.0 cmCanto: 40.0 cm
Sup X: 6Ø5/8"c/27Sup Y: 6Ø5/8"c/27Inf X: 6Ø5/8"c/27Inf Y: 6Ø5/8"c/27
(C2-C3) Zapata rectangular excéntricaAncho inicial X: 175.0 cmAncho inicial Y: 55.0 cmAncho final X: 175.0 cmAncho final Y: 55.0 cmAncho zapata X: 350.0 cmAncho zapata Y: 110.0 cmCanto: 40.0 cm
Sup X: 4Ø5/8"c/27Sup Y: 13Ø5/8"c/27Inf X: 4Ø5/8"c/27Inf Y: 13Ø5/8"c/27
(C6-C7) Zapata rectangular excéntricaAncho inicial X: 162.5 cmAncho inicial Y: 50.0 cmAncho final X: 162.5 cmAncho final Y: 50.0 cmAncho zapata X: 325.0 cmAncho zapata Y: 100.0 cmCanto: 40.0 cm
Sup X: 3Ø3/4"c/28Sup Y: 12Ø5/8"c/27Inf X: 3Ø5/8"c/27Inf Y: 12Ø5/8"c/27
(C10-C26) Zapata rectangular excéntricaAncho inicial X: 172.5 cmAncho inicial Y: 52.5 cm
Ancho final X: 172.5 cmAncho final Y: 52.5 cmAncho zapata X: 345.0 cmAncho zapata Y: 105.0 cmCanto: 40.0 cm
Sup X: 4Ø5/8"c/27Sup Y: 13Ø5/8"c/27Inf X: 4Ø5/8"c/27
Inf Y: 13Ø5/8"c/27
1.2.- Medición
Referencias: C1, C4, C5, C9, C11, C14, C16, C19, C20 y C24 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
25.4425.30
44.2069.04 94.34
Total con mermas(10.00%)
Longitud (m)Peso (kg)
27.9827.83
48.6275.94 103.77
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 79/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 79
Referencia: C8 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
7x1.757x2.73
12.2519.14
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
7x1.757x2.73
12.2519.14
Parrilla superior - Armado X Longitud (m)Peso (kg)
7x1.757x2.73
12.2519.14
Parrilla superior - Armado Y Longitud (m)Peso (kg)
7x1.757x2.73
12.2519.14
Arranque - Armado longitudinal Longitud (m)Peso (kg)
8x2.018x3.14
16.0825.12
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Totales Longitud (m)Peso (kg)
3.692.07
65.08101.68 103.75
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
71.59111.85 114.13
Referencia: C12 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Arranque - Armado longitudinal Longitud (m)Peso (kg)
8x1.988x3.09
15.8424.74
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Totales Longitud (m)Peso (kg)
3.692.07
60.0493.78 95.85
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
66.04103.16 105.44
Referencia: C13 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Arranque - Armado longitudinal Longitud (m)Peso (kg)
8x1.988x3.09
15.8424.74
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Totales Longitud (m)Peso (kg)
3.692.07
62.0496.90 98.97
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
68.24106.59 108.87
Referencia: C15 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x1.785x2.78
8.9013.90
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x1.785x2.78
8.9013.90
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 80/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 80
Referencia: C15 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8312x1.82
21.9621.84
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
25.8025.66
17.8027.80 53.46
Total con mermas(10.00%)
Longitud (m)Peso (kg)
28.3828.23
19.5830.58 58.81
Referencia: C17 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8" Ø3/4"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.215x3.45
11.0517.26
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x3.36
8.6013.43
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x4.81
8.6019.24
Totales Longitud (m)Peso (kg)
3.692.07
52.8082.47
8.6019.24 103.78
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
58.0890.71
9.4621.17 114.16
Referencia: C18 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.165x3.37
10.8016.87
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.165x3.37
10.8016.87
Parrilla superior - Armado X Longitud (m)Peso (kg) 5x2.165x3.37 10.8016.87
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.165x3.37
10.8016.87
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
25.4425.30
43.2067.48 92.78
Total con mermas(10.00%)
Longitud (m)Peso (kg)
27.9827.83
47.5274.23 102.06
Referencia: C21 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.265x3.53
11.3017.65
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.265x3.53
11.3017.65
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.265x3.53
11.3017.65
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.265x3.53
11.3017.65
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 81/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 81
Referencia: C21 Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
25.4425.30
45.2070.60 95.90
Total con mermas(10.00%)
Longitud (m)Peso (kg)
27.9827.83
49.7277.66 105.49
Referencia: C22 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8" Ø3/4"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla superior - Armado X Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Parrilla superior - Armado Y Longitud (m)Peso (kg)
5x2.315x3.61
11.5518.04
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x3.36
8.6013.43
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x4.81
8.6019.24
Totales Longitud (m)Peso (kg)
3.692.07
54.8085.59
8.6019.24 106.90
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
60.2894.15
9.4621.16 117.59
Referencia: C23 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8" Ø3/4"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
8x1.908x2.97
15.2023.74
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
8x1.908x2.97
15.2023.74
Parrilla superior - Armado X Longitud (m)Peso (kg)
8x1.908x2.97
15.2023.74
Parrilla superior - Armado Y Longitud (m)Peso (kg) 8x1.908x2.97 15.2023.74
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.234x3.48
8.9213.93
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.234x4.99
8.9219.96
Totales Longitud (m)Peso (kg)
3.692.07
69.72108.89
8.9219.96 130.92
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
76.69119.78
9.8121.95 144.01
Referencia: C25 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
6x2.416x3.76
14.4622.59
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
6x2.416x3.76
14.4622.59
Parrilla superior - Armado X Longitud (m)Peso (kg)
6x2.416x3.76
14.4622.59
Parrilla superior - Armado Y Longitud (m)Peso (kg)
6x2.416x3.76
14.4622.59
Arranque - Armado longitudinal Longitud (m)Peso (kg)
8x1.988x3.09
15.8424.74
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 82/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 82
Referencia: C25 Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Totales Longitud (m)Peso (kg)
3.692.07
73.68115.10 117.17
Total con mermas(10.00%)
Longitud (m)Peso (kg)
4.062.28
81.05126.61 128.89
Referencia: (C2-C3) Grado 60 Total
Nombre de armado Ø3/8" Ø5/8" Ø3/4"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
4x4.314x6.73
17.2426.93
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
13x1.9113x2.98
24.8338.79
Parrilla superior - Armado X Longitud (m)Peso (kg)
4x4.314x6.73
17.2426.93
Parrilla superior - Armado Y Longitud (m)Peso (kg)
13x1.9113x2.98
24.8338.79
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x3.36
8.6013.43
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Arranque - Armado longitudinal Longitud (m)Peso (kg)
8x1.988x3.09
15.8424.74
Arranque - Estribos Longitud (m)Peso (kg)
3x1.233x0.69
3.692.07
Arranque - Armado longitudinal Longitud (m)Peso (kg)
4x2.154x4.81
8.6019.24
Totales Longitud (m)Peso (kg)
7.384.14
108.58169.61
8.6019.24 192.99
Total con mermas(10.00%)
Longitud (m)Peso (kg)
8.124.55
119.44186.58
9.4621.16 212.29
Referencia: (C6-C7) Grado 60 Total
Nombre de armado Ø1/2" Ø5/8" Ø3/4"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
3x4.053x6.33
12.1518.98
Parrilla inferior - Armado Y Longitud (m)Peso (kg) 12x1.8012x2.81 21.6033.74
Parrilla superior - Armado X Longitud (m)Peso (kg)
3x4.153x9.28
12.4527.85
Parrilla superior - Armado Y Longitud (m)Peso (kg)
12x1.8012x2.81
21.6033.74
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
50.8850.60
55.3586.46
12.4527.85 164.91
Total con mermas(10.00%)
Longitud (m)Peso (kg)
55.9755.66
60.8995.11
13.7030.63 181.40
Referencia: (C10-C26) Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla inferior - Armado X Longitud (m)Peso (kg)
4x4.264x6.65
17.0426.62
Parrilla inferior - Armado Y Longitud (m)Peso (kg)
13x1.8613x2.91
24.1837.77
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 83/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 83
Referencia: (C10-C26) Grado 60 Total
Nombre de armado Ø1/2" Ø5/8"
Parrilla superior - Armado X Longitud (m)Peso (kg)
4x4.264x6.65
17.0426.62
Parrilla superior - Armado Y Longitud (m)Peso (kg)
13x1.8613x2.91
24.1837.77
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Arranque - Armado longitudinal Longitud (m)Peso (kg)
12x1.8012x1.79
21.6021.48
Arranque - Estribos Longitud (m)Peso (kg)
3x1.283x1.27
3.843.82
Totales Longitud (m)Peso (kg)
50.8850.60
82.44128.78 179.38
Total con mermas(10.00%)
Longitud (m)Peso (kg)
55.9755.66
90.68141.66 197.32
Resumen de medición (se incluyen mermas de acero)
Grado 60 (kg) Hormigón (m³) Encofrado(m²)
Elemento Ø3/8" Ø1/2" Ø5/8" Ø3/4" Total f'c=210 Limpieza
Referencias: C1, C4, C5, C9, C11, C14, C16, C19, C20 y C24 10x27.83 10x75.94 1037.70 10x0.78 10x0.20 10x1.92Referencia: C8 2.28 111.85 114.13 1.44 0.36 2.72
Referencia: C12 2.28 103.16 105.44 0.78 0.20 1.76
Referencia: C13 2.28 106.59 108.87 0.90 0.23 1.76
Referencia: C15 28.23 30.58 58.81 0.84 0.21 2.00
Referencia: C17 2.27 90.72 21.17 114.16 0.78 0.20 1.60
Referencia: C18 27.83 74.23 102.06 0.73 0.18 1.52
Referencia: C21 27.83 77.66 105.49 0.84 0.21 2.00
Referencia: C22 2.28 94.15 21.16 117.59 0.90 0.23 1.92
Referencia: C23 2.28 119.78 21.95 144.01 1.89 0.42 3.21
Referencia: C25 2.28 126.61 128.89 1.02 0.26 2.24
Referencia: (C2-C3) 4.56 186.57 21.16 212.29 1.54 0.39 3.04
Referencia: (C6-C7) 55.66 95.11 30.63 181.40 1.30 0.33 2.44
Referencia: (C10-C26) 55.66 141.66 197.32 1.45 0.36 2.96
Totales 20.51 473.51 2118.07 116.07 2728.16 22.27 5.51 48.37
2.- LISTADO DE VIGAS DE ATADO
2.1.- Descripción
Referencias Tipo Geometría Armado
[C13 - C18],[C14 - C19],[C12 - C17],[C11 - C16],[C15 - C20]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C18 - C23],[C19 - C24],[C17 - C22],[C16 - C21],[C20 - C25]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C22 - C23],[C17 - C18],[C12 - C13]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 84/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 84
Referencias Tipo Geometría Armado
[C21 - C22],[C16 - C17],[C11 - C12]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C24 - C25],[C14 - C15],[C19 - C20]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C23 - C24],[C18 - C19],
[C13 - C14],[(C2-C3) - C4],[(C6-C7) - C8]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"
Estribos: 1xØ3/8"c/20
[C9 - C11] C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C5 - C9],[C1 - C5],[C4 - C8],[(C2-C3) - (C6-C7)],[(C2-C3) - (C6-C7)],[(C6-C7) - (C10-C26)],[(C6-C7) - (C10-C26)]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[C1 - (C2-C3)],[C9 - (C10-C26)],[C5 - (C6-C7)]
C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
[(C10-C26) - C13] C.2.2 Ancho: 40.0 cmCanto: 40.0 cm
Superior: 2Ø5/8"Inferior: 2Ø5/8"Estribos: 1xØ3/8"c/20
2.2.- Medición
Referencias: [C13 - C18], [C14 - C19], [C12 - C17],[C11 - C16] y [C15 - C20]
Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x7.352x11.48
14.7022.96
Armado viga - Armado superior Longitud (m)Peso (kg)
2x7.352x11.48
14.7022.96
Armado viga - Estribo Longitud (m)Peso (kg)
28x1.2528x0.70
35.0019.59
Totales Longitud (m)
Peso (kg)
35.00
19.59
29.40
45.92 65.51Total con mermas(10.00%)
Longitud (m)Peso (kg)
38.5021.55
32.3450.51 72.06
Referencias: [C18 - C23], [C19 - C24], [C17 - C22],[C16 - C21] y [C20 - C25]
Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x6.202x9.69
12.4019.37
Armado viga - Armado superior Longitud (m)Peso (kg)
2x6.202x9.69
12.4019.37
Armado viga - Estribo Longitud (m)Peso (kg)
21x1.2521x0.70
26.2514.69
Totales Longitud (m)Peso (kg)
26.2514.69
24.8038.74 53.43
Total con mermas
(10.00%)
Longitud (m)
Peso (kg)
28.88
16.16
27.28
42.61 58.77
Referencias: [C22 - C23], [C17 - C18] y [C12 - C13] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x4.702x7.34
9.4014.68
Armado viga - Armado superior Longitud (m)Peso (kg)
2x4.702x7.34
9.4014.68
Armado viga - Estribo Longitud (m)Peso (kg)
13x1.2513x0.70
16.259.10
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 85/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 85
Referencias: [C22 - C23], [C17 - C18] y [C12 - C13] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Totales Longitud (m)Peso (kg)
16.259.10
18.8029.36 38.46
Total con mermas(10.00%)
Longitud (m)Peso (kg)
17.8810.01
20.6832.30 42.31
Referencias: [C21 - C22], [C16 - C17] y [C11 - C12] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"Armado viga - Armado inferior Longitud (m)
Peso (kg)2x6.97
2x10.8913.9421.78
Armado viga - Armado superior Longitud (m)Peso (kg)
2x6.972x10.89
13.9421.78
Armado viga - Estribo Longitud (m)Peso (kg)
26x1.2526x0.70
32.5018.19
Totales Longitud (m)Peso (kg)
32.5018.19
27.8843.56 61.75
Total con mermas(10.00%)
Longitud (m)Peso (kg)
35.7520.01
30.6747.92 67.93
Referencias: [C24 - C25], [C14 - C15] y [C19 - C20] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)
Peso (kg)
2x6.46
2x10.09
12.92
20.18Armado viga - Armado superior Longitud (m)
Peso (kg)2x6.46
2x10.0912.9220.18
Armado viga - Estribo Longitud (m)Peso (kg)
23x1.2523x0.70
28.7516.09
Totales Longitud (m)Peso (kg)
28.7516.09
25.8440.36 56.45
Total con mermas(10.00%)
Longitud (m)Peso (kg)
31.6317.70
28.4244.40 62.10
Referencias: [C23 - C24], [C18 - C19], [C13 - C14],[(C2-C3) - C4] y [(C6-C7) - C8]
Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x6.672x10.42
13.3420.84
Armado viga - Armado superior Longitud (m)Peso (kg)
2x6.672x10.42
13.3420.84
Armado viga - Estribo Longitud (m)Peso (kg)
23x1.2523x0.70
28.7516.09
Totales Longitud (m)Peso (kg)
28.7516.09
26.6841.68 57.77
Total con mermas(10.00%)
Longitud (m)Peso (kg)
31.6317.70
29.3545.85 63.55
Referencia: [C9 - C11] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x4.362x6.81
8.7213.62
Armado viga - Armado superior Longitud (m)Peso (kg)
2x4.362x6.81
8.7213.62
Armado viga - Estribo Longitud (m)
Peso (kg)
11x1.25
11x0.70
13.75
7.70Totales Longitud (m)
Peso (kg)13.757.70
17.4427.24 34.94
Total con mermas(10.00%)
Longitud (m)Peso (kg)
15.138.47
19.1829.96 38.43
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 86/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 86
Referencias: [C5 - C9], [C1 - C5], [C4 - C8], [(C2-C3) - (C6-C7)],[(C2-C3) - (C6-C7)], [(C6-C7) - (C10-C26)] y [(C6-C7) - (C10-C26)]
Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x4.902x7.65
9.8015.31
Armado viga - Armado superior Longitud (m)Peso (kg)
2x4.902x7.65
9.8015.31
Armado viga - Estribo Longitud (m)
Peso (kg)
16x1.25
16x0.70
20.00
11.19Totales Longitud (m)Peso (kg)
20.0011.19
19.6030.62 41.81
Total con mermas(10.00%)
Longitud (m)Peso (kg)
22.0012.31
21.5633.68 45.99
Referencias: [C1 - (C2-C3)], [C9 - (C10-C26)] y [C5 - (C6-C7)] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x6.402x10.00
12.8020.00
Armado viga - Armado superior Longitud (m)Peso (kg)
2x6.402x10.00
12.8020.00
Armado viga - Estribo Longitud (m)Peso (kg)
24x1.2524x0.70
30.0016.79
Totales Longitud (m)Peso (kg)
30.0016.79
25.6040.00 56.79
Total con mermas(10.00%)
Longitud (m)Peso (kg)
33.0018.47
28.1644.00 62.47
Referencia: [(C10-C26) - C13] Grado 60 Total
Nombre de armado Ø3/8" Ø5/8"
Armado viga - Armado inferior Longitud (m)Peso (kg)
2x3.602x5.62
7.2011.25
Armado viga - Armado superior Longitud (m)Peso (kg)
2x3.602x5.62
7.2011.25
Armado viga - Estribo Longitud (m)Peso (kg)
10x1.2510x0.70
12.507.00
Totales Longitud (m)Peso (kg)
12.507.00
14.4022.50 29.50
Total con mermas(10.00%)
Longitud (m)Peso (kg)
13.757.70
15.8424.75 32.45
Resumen de medición (se incluyen mermas de acero)
Grado 60 (kg) Hormigón (m³) Encofrado(m²)
Elemento Ø3/8" Ø5/8" Total f'c=210 Limpieza
Referencias: [C13 - C18], [C14 - C19], [C12 - C17],[C11 - C16] y [C15 - C20]
5x21.55 5x50.51 360.30 5x0.85 5x0.21 5x4.26
Referencias: [C18 - C23], [C19 - C24], [C17 - C22],[C16 - C21] y [C20 - C25]
5x16.16 5x42.61 293.85 5x0.62 5x0.16 5x3.12
Referencias: [C22 - C23], [C17 - C18] y [C12 - C13] 3x10.01 3x32.30 126.93 3x0.37 3x0.09 3x1.86
Referencias: [C21 - C22], [C16 - C17] y [C11 - C12] 3x20.01 3x47.92 203.79 3x0.78 3x0.20 3x3.92
Referencias: [C24 - C25], [C14 - C15] y [C19 - C20] 3x17.70 3x44.40 186.30 3x0.70 3x0.17 3x3.49
Referencias: [C23 - C24], [C18 - C19], [C13 - C14],[(C2-C3) - C4] y [(C6-C7) - C8]
5x17.70 5x45.85 317.75 5x0.70 5x0.17 5x3.48
Referencia: [C9 - C11] 8.47 29.96 38.43 0.32 0.08 1.61
Referencias: [C5 - C9], [C1 - C5], [C4 - C8], [(C2-C3) - (C6-C7)],[(C2-C3) - (C6-C7)], [(C6-C7) - (C10-C26)] y [(C6-C7) - (C10-C26)]
7x12.31 7x33.68 321.93 7x0.46 7x0.12 7x2.32
Referencias: [C1 - (C2-C3)], [C9 - (C10-C26)] y [C5 - (C6-C7)] 3x18.47 3x44.00 187.41 3x0.73 3x0.18 3x3.64
Referencia: [(C10-C26) - C13] 7.70 24.75 32.45 0.28 0.07 1.38
Totales 577.96 1491.18 2069.14 22.45 5.61 112.24
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 87/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015
Ing. Civil : HARRY ALEJANDRO PINEDA PADILLA – M.P. 05202094410 ANT.. Cel: 320 720 35 85
Página 87
8.6. CANTIDADES DE OBRA
Elemento Superficie (m2)
Vigas 0.01
Total 0.01
Índices (por m2) 1.000
PISO1 - Superficie total: 59.65 m2
Elemento Superficie (m2) Volumen (m3) Barras (Kg)
Vigas 56.46 21.67 3473Encofrado lateral 131.64
Pilares (Sup. Encofrado) 60.06 5.20 2787
Total 248.16 26.87 6260
Índices (por m2) 4.160 0.450 104.95
PISO2 - Superficie total: 197.26 m2
Elemento Superficie (m2) Volumen (m3) Barras (Kg)
Forjados 116.10 11.61 2695
Vigas 77.97 29.51 5294
Encofrado lateral 172.68
Pilares (Sup. Encofrado) 104.30 9.07 4564
Total 471.05 50.19 12553
Índices (por m2) 2.388 0.254 63.64
CUBIERTA - Superficie total: 0.61 m2
Elemento Superficie (m2)
Pilares (Sup. Encofrado) 0.00
Total 0.00
Índices (por m2) 0.000
Total obra - Superficie total: 257.53 m2
Elemento Superficie (m2) Volumen (m3) Barras (Kg)
Forjados 116.10 11.61 2695
Vigas 134.44 51.18 8767
Encofrado lateral 304.32
Pilares (Sup. Encofrado) 164.36 14.27 7351
Total 719.22 77.06 18813
Índices (por m2) 2.793 0.299 73.05
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 88/89
7/21/2019 Memoria de Calculo Estructural Centro de Salud de Tanela
http://slidepdf.com/reader/full/memoria-de-calculo-estructural-centro-de-salud-de-tanela 89/89
Memoria Estructural del Centro de Salud del Corregimiento de Tanela, – Municipio de Unguia – Chocó – 2015