Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17...

17
Pre-production datasheet - The producer retains the right to change any technical parameters without previous written notice. . Industrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 www.metel.eu 1/17 www.iplog.eu Pre-production datasheet - The producer retains the right to change any technical parameters without previous written notice. . DI AI RE AO DO DI AI RE AO DO v IPLOGs are Linux based PLCs with support for writing user scripts v COM-IO modules support Modbus, M-BUS, RS485, RS232, 1-Wire and other standards v IO modules support a wide variety of analog I/O, digital I/O and relays outputs v IEC 61131-3 IDE and graphical SIMULand GUI for industrial and security applications v High security is assured by SSH, openVPN, SNMPv3, 802.1X and other tools used by IT experts v Highly durable hardware with integrated overvoltage protections v Operating temperatures from °C to +70°C INDUSTRIAL AUTOMATION MIOS-2 or MODBUS IO modules and sensors allow for the monitoring and controlling of environment variables according to specified requirements. A wide range of inputs / outputs are available directly in IPLOGs. RS232 Typical Applications of the IPLOG System versatility APP PLUGINS Custom-made plugins integrate with 3rd party security & automation systems. SMART METERING IPLOGs can remotely collect values of power, water and gas meters. PROCESS VISUALIZATION IPLOGs can be easily integrated in 3rd party systems via SNMP and EN 60870-5-104 protocols. OFF THE GRID SYSTEMS IPLOGs are designed to be efficient and are optimized for off-the-grid security or automation systems powered from renewable energy systems. GSM CONNECTIVITY Measured values and alarms are available online and they can be also sent via e-mail or SMS messages. IP WATCHDOG Integrated IP Watchdogs monitor the availability of IP devices. In the event of a problem an automatic restart SNMP, e-mail or SMS message will be triggered. PLC with 2 port switch PLC with GSM Port IO module COM GSM LAN DI AI RE AO DO IP CCTV SYSTEMS IPLOGs are able to control IP cameras via ONVIF protocol and process images.

Transcript of Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17...

Page 1: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 1/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice.. DI AI RE AO DODI AI RE AO DO

v IPLOGs are Linux based PLCs with support for writing user scripts

v COM-IO modules support Modbus, M-BUS, RS485, RS232, 1-Wire and other standards

v IO modules support a wide variety of analog I/O, digital I/O and relays outputs

v IEC 61131-3 IDE and graphical SIMULand GUI for industrial and security applications

v High security is assured by SSH, openVPN, SNMPv3, 802.1X and other tools used by IT experts

v Highly durable hardware with integrated overvoltage protections

v Operating temperatures from °C to +70°C

INDUSTRIAL AUTOMATIONMIOS-2 or MODBUS IO modules and sensors allow for the monitoring and controlling of environment variables according to specified requirements.

A wide range of inputs / outputs are available directly in IPLOGs.

RS232

Typical Applications of the IPLOG System versatility

APP PLUGINSCustom-made plugins integrate with 3rd party security & automation systems.

SMART METERINGIPLOGs can remotely collect values of power, water and gas meters.

PROCESS VISUALIZATIONIPLOGs can be easily integrated in 3rd party systems via SNMP and EN 60870-5-104 protocols.

OFF THE GRID SYSTEMSIPLOGs are designed to be efficient and are optimized for off-the-grid security or automation systems powered from renewable energy systems.

GSM CONNECTIVITYMeasured values and alarms are available online and they can be also sent via e-mail or SMS messages. IP WATCHDOG

Integrated IP Watchdogs monitor the availability of IP devices. In the event of a problem an automatic restart SNMP, e-mail or SMS message will be triggered.

PLC with 2 port switch PLC with GSM Port IO module

COM

GSM

LAN

DI

AI

RE

AO

DO

IP CCTV SYSTEMSIPLOGs are able to control IP cameras via ONVIF protocol and process images.

Page 2: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 2/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

HardwareProgrammable logic controllers IPLOG have an outstanding modular design.

SoftwareIPLOGs and their IO modules are suitable for a wide variety of applications from industrial automation to

building automation and applications in security systems. IPLOGs can be configured in three different

ways.GUI SIMULand.v4 for Easy Setup

SIMULand.v4 software is a very useful tool especially in

situations where you need to quickly configure a

simple system without knowledge of IEC or script

programming. Its main advantages are:

v Graphical user interface

v CHAT client with technical support

v VPN client for remote help

SSH Console for IT Experts

IPLOGs are Linux based PLCs. Their large memory is

available for user applications. PLCs are delivered with

a standard set of tools. The user can download

additional packages from repositories. IPLOGs can be

programmed via scripts: Bash, PHP, Python

IEC 61131-3 IDE for Automation Professionals

IDE allows you to write code in any of the supported

IEC-61131-3 control languages:

v Ladder diagram (LD)

v Function block diagram (FBD)

v Structured text (ST)

v Instruction list (IL)

COM-IO Slot 2

IO ConnectorIO Module

IO Connector

COM IOModule

COM IOModule

CPU Module

Motherboard

LAN and GSM Ports

USB-A USB-B

COM-IO Slot 1

Power Input

Page 3: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 3/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

INTERFACE IPLOG-G1 IPLOG-G2 IPLOG-G3 SURGE PROTECTION NOTE

Power Input 1 1 1 600 W (10/1000 µs)

IPLOG-G1 with CPU module IPLOG-G2 with CPU module IPLOG-G3

Motherboards provide PLC connectivity via LAN and GSM / GPRS interfaces. In addition, the

Motherboards are equipped with other important interfaces for interconnection with COMmunication

and IO modules. The full list of the available interfaces are listed in the table below:

Power Supply InputThe modern design of the switching supplies allows

the powering of IPLOG units in a wide range of

input voltages. IPLOGs can be powered directly

from batteries because power supplies are

automatically disabled when the input voltage is

below 10V.

CPU Module Interface CPU module interface is compatible with G and newer models of CPU modules. Modules are based on a CORTEX A5 ARM microprocessor running on a Linux embeded OS. The module has an operating temperature range from to + 70°C and contains storage space of 128MB FLASH and 256MB RAM for customer applications.

Available Motherboards

CPU Module Interface 1 1 1 -

PARAMETER VALUE NOTE

Quantity 1 Twin screw terminals

Input Voltage 10(20) to 60 VDC (..) AIx models

Power Consumption G1: 3W

G2: 5W*

Ethernet 10/100BASE-T 2 1 1 150 A (10/1000 µs) IEC 61000-4-5

GSM/GPRS 0 1 (2G/3G) 1 (2G/3G/4G) - G3: 2x SIM holder

USB-A, Max. 500mA 1 1 1 ±15 kV IEC 61000-4-2

USB-B 1 1 1 Local programming console

COM IO Module Interface 1 1 1 -

IO Module Interface 1 1 1 -

G3: 5W*

SD card

512 MB RAM

RTC

256 MB NAND

16 MB NORCPU CORTEX

TFT interface

*The reported values are an average among all bands.

Page 4: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 4/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

PARAMETER USB-A USB-B

Standard USB 2.0 USB 2.0

IPLOG Mode USB host USB device

Function External storage Local management

Ethernet portsIPLOG-G1 series include 2 port ethernet managed switches with support for: RSTP - redundant LAN connectionQoS - packets can be processed in accordance with the assigned prioritiesVLAN - splitting of data into virtual networksIPLOG-G2 and IPLOG-G3 series include 1 ethernet suitable for communication with locally connected peripheries.

GSM/GPRS portIPLOG-G2 and IPLOG-G3 series are equipped with a wireless GSM/ GPRS module. It can be used for:

v Data collection from distant objects

v Sending and receiving SMS

v Firmware upgrade The wireless module can be shut down, if required

as a maximum energy-saving option.

USB portsIPLOGs PLCs are equipped with USB-A and USB-B connectors which are in accordance with the USB 2.0 standard. The basic ways of using the USB ports are the following:Connection of remote mass storage – IPLOG can in the USB host mode use external USB mass storage as additional memory for storing or reading data.Local secured management – for security purposes

remote management can be prohibited. In such situations the local USB console can be used.

COM IO Module InterfaceWithin this interface is the possibility to assemble any type of COM IO modules listed on the following pages. Modules can be assembled / dissasembled only when the motherboard is disconnected from the power supply. After connection to the input

power, a new COM lO module is automatically

detected and available. COM channels and inputs/outputs are accessed in the configuration software.

IO Module InterfaceWithin this interface is the possibility to assemble

any type of lO modules together with any other

COM-IO modules listed on the following pages. Modules can be assembled / dissasmbled only when the motherboard is disconnected from the power supply. After connection the input power a new IO module is automatically detected and available inputs/outputs are accessed in the configuration software.

PARAMETER VALUE NOTE

Quantity 0 / 1 G1 / G2, G3

Connectors SMA

Freq. Bands 2G 900 / 1800 MHz

Freq. Bands 3G 900 / 2100 MHz

Freq. Bands 4G 800 / 1800 / 2600 MHz

Data Connectivity GPRS, EDGE, UMTS, HSDPA

SIM Slot microSIM

Protection Transil Transil

Output Current Max. 500 mA -

PARAMETER VALUE NOTE

Quantity 2 / 1 G1 / G2, G3

Connectors Shielded RJ45

Data Speed 10/100BaseT

AutoMDI-MDIX Yes

Auto-Negotiation Yes

Protocols VLAN, QoS, RSTP, IGMP

PARAMETER VALUE NOTE

Quantity 2 / 1 G1 / G2, G3

Connectors Shielded RJ45

Data Speed 10/100BaseT

AutoMDI-MDIX Yes

Auto-Negotiation Yes

Protocols VLAN, QoS, RSTP, IGMP

Available Motherboards

Page 5: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 5/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Available Modifications

IPLOG-G1

When ordering it is necessary to indicate the correct name of the device which is governed by the

following rules:

v IPLOG s marking depends on the motherboard, IO module, COM-IO modules and CPU modules used.

The control units are designed in such a way that the modules can be changed at any time. Any new

module is then automatically detected and available for use.

v All IO modules can be used as IPLOGs subboards or as standalone modules connected via the RS485.

v The control units are designed in such a way that the COM or COM-IO modules can be changed at any

time. A new module is then automatically detected and available for use.

The 2nd option in ordering is to indicate the order code of the device.

Application Example: IPLOG as control unit integrating security systems and visualization

IPLOG-G1-01-BO8.1 - forwards alarms from perimeter system Peridect+ To 3rd party alarm panels (relay or resistive outputs) or to visualization softwares with SNMPv3 support.

IPLOG-G1-xx-AI4.1-yy 55xx-03yy 2 - xx yy - 4 - - 4 - - - - - - 4 - -

IPLOG-G1-xx-DI8.1-yy 55xx-01yy 2 - xx yy - 8 - - - - 4 - - - - - - 2

IPLOG-G1-xx-RE8.1-yy 55xx-05yy 2 - xx yy - - 3 - - - 8 - 2 - - - - -

IPLOG-G1-xx-PP8.1-yy 55xx-07yy 2 - xx yy - 4 - - - 3 - 1 - - - - - 8

PRODUCT NAME CODE

COM

1 2LAN

GPR

S

IPLOG-G1 – Ordering Information

DI 5

V

DI 2

4V

DI 2

30V

AI

- U

/I

AI

- R

TD

BI (

alar

m)

/ D

I

RE

- N

O-2

30V

RE

- N

OC

RE

- N

OC

-230

V

AO

BO

DO

(SSR

)

OC

NPN

PUSH

/ P

ULL

IPLOG-G1-xx 55xx-0000 2 - xx - - - - - - - - - - - - - - -

IPLOG-G1-xx-AI8.1-yy 55xx-02yy 2 - xx yy - - - 8 - - 2 2 - - - - - -

IPLOG-G1-xx-AO8.1-yy 55xx-06yy 2 - xx yy - 4 - 4 - - - - - 8 - - - -

IPLOG-G1-xx-BO8.1-yy 55xx-08yy 2 - xx yy - - - - - 3 - 1 - - 8 - 2 -

IPLOG-G1-xx-BI8.1-yy 55xx-04yy 2 - xx yy 3 - - - - 8 - 1 - - - - 2 -

The symbols used xx and yy replace the assembled version of the COM IO modules.

CUP+

SNMPv3

TCP

Visualization

RS485

Alarm panel

Alarm loops

Page 6: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 6/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

When ordering it is necessary to indicate the correct name of the device which is governed by the

following rules:

v IPLOG s marking depends on the motherboard, IO module, COM-IO modules and CPU modules used.

The control units are designed in such a way that the modules can be changed at any time. Any new

module is then automatically detected and available for use.

v All IO modules can be used as IPLOGs subboards or as standalone modules connected via the RS485.

v The control units are designed in such a way that the COM or COM-IO modules can be changed at any

time. A new module is then automatically detected and available for use.

The 2nd option in ordering is to indicate the order code of the device.

Application Example: IPLOG-G2-07G-DI8.1 as a centralized distribution of beverages. v The IPLOGs with IO modules are installed in each warehouse with beverages tanksv Filling and pumping of beverages is centrally recordedv Suppliers and customers authenticate themselves using Ibutton readers

IPLOG-G2 – Ordering Information

Available Modifications

IPLOG-G2

IPLOG-G2-xx-AI4.1-yy 56xx-03yy 1 1 xx yy - 4 - - 4 - - - - - - 4 - -

IPLOG-G2-xx-DI8.1-yy 56xx-01yy 1 1 xx yy - 8 - - - - 4 - - - - - - 2

IPLOG-G2-xx-RE8.1-yy 56xx-05yy 1 1 xx yy - - 3 - - - 8 - 2 - - - - -

IPLOG-G2-xx-PP8.1-yy 56xx-07yy 1 1 xx yy - 4 - - - 3 - 1 - - - - - 8

PRODUCT NAME CODE

COM

1 2LAN

GPR

S

DI 5

V

DI 2

4V

DI 2

30V

AI

- U

/I

AI

- R

TD

BI (

alar

m)

/ D

I

RE

- N

O-2

30V

RE

- N

OC

RE

- N

OC

-230

V

AO

BO

DO

(SSR

)

OC

NPN

PUSH

/ P

ULL

IPLOG-G2-xx-AO8.1-yy 56xx-06yy 1 1 xx yy - 4 - 4 - - - - - 8 - - - -

IPLOG-G2-xx-BO8.1-yy 56xx-08yy 1 1 xx yy - - - - - 3 - 1 - - 8 - 2 -

IPLOG-G2-xx 56xx-0000 1 1 xx - - - - - - - - - - - - - - -

IPLOG-G2-xx-AI8.1-yy 56xx-02yy 1 1 xx yy - - - 8 - - 2 2 - - - - - -

IPLOG-G2-xx-BI8.1-yy 56xx-04yy 1 1 xx yy 3 - - - - 8 - 1 - - - - 2 -

The symbols used xx and yy replace the assembled version of the COM IO modules.

Fl Fl Fl Fl

RS485

1-Wire

Page 7: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 7/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

When ordering it is necessary to indicate the correct name of the device which is governed by the

following rules:

v IPLOG s marking depends on the motherboard, IO module, COM-IO modules and CPU modules used.

The control units are designed in such a way that the modules can be changed at any time. Any new

module is then automatically detected and available for use.

v All IO modules can be used as IPLOGs subboards or as standalone modules connected via the RS485.

v The control units are designed in such a way that the COM or COM-IO modules can be changed at any

time. A new module is then automatically detected and available for use.

The 2nd option in ordering is to indicate the order code of the device.

Application Example: IPLOG in the OFF-THE-GRID security application

IPLOG-G3-01-BI8.1-06 - the diagram shows the protection of a vineyard in the DEMO system in Česká Skalice (Czech Republic). The main goal of the system is to secure and automate the area without any electricity. The main functions are:v In the situation when some PIR sensor detects movemnet, the camera is turned towards this sensor in

an alarm state and starts recordingv During the night the PLC automatically turns on the IR lights v Disturbs the birds eating grapes by randomly playing pre-recorded soundsv The perimeter system is guarded by a fence

IPLOG-G3 – Ordering Information

Available Modifications

IPLOG-G3

IPLOG-G3-xx-AI4.1-yy 57xx-03yy 1 1 xx yy - 4 - - 4 - - - - - - 4 - -

IPLOG-G3-xx-DI8.1-yy 57xx-01yy 1 1 xx yy - 8 - - - - 4 - - - - - - 2

IPLOG-G3-xx-RE8.1-yy 57xx-05yy 1 1 xx yy - - 3 - - - 8 - 2 - - - - -

IPLOG-G3-xx-PP8.1-yy 57xx-07yy 1 1 xx yy - 4 - - - 3 - 1 - - - - - 8

PRODUCT NAME CODE

COMSLOT

1 2LAN

GPR

S

DI 5

V

DI 2

4V

DI 2

30V

AI

- U

/I

AI

- R

TD

BI (

alar

m)

/ D

I

RE

- N

O-2

30V

RE

- N

OC

RE

- N

OC

-230

V

AO

BO

DO

(SSR

)

OC

NPN

PUSH

/ P

ULL

IPLOG-G3-xx-AO8.1-yy 57xx-06yy 1 1 xx yy - 4 - 4 - - - - - 8 - - - -

IPLOG-G3-xx-BO8.1-yy 57xx-08yy 1 1 xx yy - - - - - 3 - 1 - - 8 - 2 -

IPLOG-G3-xx 57xx-0000 1 1 xx - - - - - - - - - - - - - - -

IPLOG-G3-xx-AI8.1-yy 57xx-02yy 1 1 xx yy - - - 8 - - 2 2 - - - - - -

IPLOG-G3-xx-BI8.1-yy 57xx-04yy 1 1 xx yy 3 - - - - 8 - 1 - - - - 2 -

The symbols used xx and yy replace the assembled version of the COM IO modules.

+ –+ – GSM

PLCPoE+ Injector

MPPT Power Module

Page 8: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 8/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

IO modules as seen in the table below can be assembled on motherboards or used as standalone IO

modules connected via the MIOS-2 RS485 bus to IPLOG PLC. All modules have an operating temperature

range from to +70°C. .

IPLOG Marking Standalone IO Modules Marking

Available IO Modules

IO modules – Ordering Information

IPLOG-G3-01G-DI8.1-02

I I I I I COM IO module

I I I I I in slot 2 (if used)

I I I I IO module (if used)

I I I COM IO module

I I I in slot 1 (if used)

I I MOTHERBOARD

I CPU module

DI8.1-01G

I I COM IO module (if used)

I IO module

GALVANICSEPARATION NOTE

Communication Channels * 1 1 1 1 1 1 1 1

Digital Inputs 5 V - - - 3 - - - -

Digital Inputs 24 V YES 8 - 4 - - 4 4 -

Digital Inputs 230 V YES - - - - 3 - - -

Analog 12-bit U/I Inputs YES - 8 - - - 4 - -

Analog 2-3 Wire RTD Inputs YES - - 4 - - - - -

8-bit Alarm / Digital Inputs 5 V - - - 8 - - 3 3

Relay Outputs TYPE 1 - NO 230 V YES 4 2 - - 8 - - -

Relay Outputs TYPE 2 - NOC YES - 2 - 1 - - 1 1

Relay Outputs TYPE 3 - NOC 230 V YES - - - - 2 - - -

Analog Outputs 12-bit - - - - - 8 - -

Analog / Alarm 8-bit Outputs - - - - - - - 8

Digital SSR Outputs YES - - 4 - - - - -

Open Collectors – NPN - - - 2 - - - 2

Open Collectors - PUSH-PULL** YES 2 - - - - - 8 -

*see communication modules spec. ** programmable as NPN or PNP

IO Module CONNECTOR A

IO Module CONNECTORS

A and DIO ModuleInside IPLOG

COM IO Modulein Slot 2

Page 9: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Industrial PLC SystemIPLOG

EN 60870-5-104 IEC 61131-3

www.metel.eu 9/17 www.iplog.eu

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

IPLOG s connectivity is ensured with IF modules. They are designed to fit into the COM interfaces Channel

1 and Channel 2. Their design is very flexible. The COM module inserted into the slot is automatically

detected by firmware and it can be at anytime exchanged for another.. Modules have an operating

temperature range from to +70°C excluding audio modules IF-06 which have an operating range

from to +70°C.

Module Connection / DisconnectionCOM-IO modules can be delivered as:

v Part of ordered PLC

v Standalone modules

In case of standalone module delivery it is

necessary to unscrew the device housing

and insert the module into the slot.

Inserting or removing should be done only when the device is disconneted from the

power source. After connecting the power

supply, the CPU automatically updates list

of available COM channels, inputs and

outputs.

& COM-IO modules can be inserted into

COM slots on motherboards or IO

modules.

COM-IO Modules – Ordering Information

MODULE CODE INTERFACES GALVANIC MAX. MAX.CABLE TERMINALS

ISOLATION BITRATE LENGTH 1 2 3 4 5

IF-01 5000-0001 2x RS485 - 1 Mbps 1.200 m +A1 -B1 GND -B2 +A2

IF-01G 5000-0002 2x RS485 1 kV 1 Mbps 1,200 m +A1 -B1 GND -B2 +A2

IF-02 5000-0003 2x RS232 - 1 Mbps 15 m RX1 TX1 GND RX2* TX2*

IF-02G 5000-0004 2x RS232 1 kV 1 Mbps 15 m RX1 TX1 GND RX2* TX2*

IF-03 5000-0005 RF M-BUS, RF KNX - TBD** - - - - - -

IF-04G 5000-0006 DALI 1 kV 1.2 kbps 300 m +DALI -DALI GND +DALI -DALI

IF-05 5000-0007 1x RS485, 2x DI - 1 Mbps 1,200 m +A1 -B1 GND IN2 IN1

IF-06 5000-0008 MIC, LINE-IN/OUT - - + LIN E IN - GND - LIN E OUT +

IF-07G 5000-0009 1x RS485, 1-Wire 1 kV 1 Mbps/- 1,200 m/100m +A -B GND 1-Wire +5

IF-08G 5000-0010 Profibus 1 kV 1 Mbps 1,200 m A A GND B B

IF-09 5000-0011 M-BUS - 9.6 kbps 350 m +BUS +BUS GND -BUS -BUS

IF-10 5000-0012 KNX 1 kV 9.6 kbps 1,000 m +BUS +BUS GND -BUS -BUS

IF-11 5000-0013 Wiegand, 2xDI - - 10 m DATA 0 DATA 1 GND IN2 IN1

Standalone COM IO Module

COM IO Module Assembled on

the Motherboard

COM-IO Slot 1

COM-IO Slot 2

* Or CTS/RTS signals **To Be Determined

Page 10: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 10/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of Analog 12-bit U/I Inputs

v 8x 12-bit Analog U/I Inputs

v 2x NOC 24V Relay Outputs

v 2x NO 230V Relay Outputs

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

20 to 60 VDC

To next module

230 VAC L N

24 VDC

NAME CODE NOTE

AI8.1-01 5000-0201 2x RS485

AI8.1-01G 5000-0202 2x RS485 (isolated)

AI8.1-07G 5000-0209 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

DIN35 installation Flat surface installation

AI8.1

Galvanic isolationGalvanic isolation

+

+

+

+

+

+

±

±

±

± +

+

±

±

±

±

+

+

± ±

Any combination of the voltage

or current modes

Auxiliary PE/GND

terminals

OR

DER

ING

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

SWITCHING HV RELAYS Type 1

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

Parameter Value Note

REL

AY

S

SWITCHING HV RELAYS Type 1

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

Parameter Value Note

REL

AY

S

SWITCHING HV RELAYS Type 1

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

Parameter Value Note

REL

AY

S

1 2 3 4 5 6 7 8 9 10

11

12

PE

GN

D

AI1

AI 2

AI 3

AI 4

AG

ND

AI 5

AI 6

AI 7

AI 8

AG

ND

1 2 3 4 5 6 7 8 9 10

11

12

- -

NO

1

CO

M 1

NC

1

NO

2

CO

M 2

NC

2

CO

M 3

HV

NO

3

MO

DEL: A

I8.1-yyCO

DE: 5000-02yy

CONN ECTOR C

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

CO

M 4

HV

NO

4

CONN ECTOR E

RELAYS5A / 250 VAC3A / 30 VDC

RELAYS0.5 A / 120 VAC1 A / 24 VDC

ANALOG INPUTSVoltage: ±2.5 V, ±5 V, ±10 V, 0 - 5V, 0 - 10V Current: 0 - 20mA, 4 - 20mA

*To Be Determined

Page 11: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 11/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of Analog 2-3 Wire RTD Inputs

v 4x 24-bit Analog RTD Inputs

v 4x SSR Outputs

v 4x 24 V Digital Inputs

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

To next module

DIN35 installation Flat surface installation

AI4.1

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

2 or 3-wire RTDs

24 VDC

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

NAME CODE NOTE

AI4.1-01 5000-0301 2x RS485

AI4.1-01G 5000-0302 2x RS485 (isolated)

AI4.1-07G 5000-0309 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

NAME CODE NOTE

AI4.1-01 5000-0301 2x RS485

AI4.1-01G 5000-0302 2x RS485 (isolated)

AI4.1-07G 5000-0309 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

230 VAC L N

20 to 60 VDC

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

Input Resistance > 50 kΩ

Resistive Ranges PT100, PT1000, Ni1000

Modes 3-wire, 2-wire

Sampling Rate 1 kSps Selectable

Resolution 24-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Input Resistance > 50 kΩ

Resistive Ranges PT100, PT1000, Ni1000

Modes 3-wire, 2-wire

Sampling Rate 1 kSps Selectable

Resolution 24-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Input Resistance > 50 kΩ

Resistive Ranges PT100, PT1000, Ni1000

Modes 3-wire, 2-wire

Sampling Rate 1 kSps Selectable

Resolution 24-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Output Type MOSFET

Load Voltage Rating 75 VAC to 264 VAC

Load Current Rating 1 A

Contact Form: SPST (1 Form A)SSR

OU

TPU

TS Parameter Value Note

Output Type MOSFET

Load Voltage Rating 75 VAC to 264 VAC

Load Current Rating 1 A

Contact Form: SPST (1 Form A)SSR

OU

TPU

TS Parameter Value Note

Output Type MOSFET

Load Voltage Rating 75 VAC to 264 VAC

Load Current Rating 1 A

Contact Form: SPST (1 Form A)SSR

OU

TPU

TS Parameter Value Note

1 2 3 4 5 6 7 8 9 10 11 12

AIN

AG

ND

AIN

+

AIN

AG

ND

AIN

+

AIN

AG

ND

AIN

+

AIN

AG

ND

1 2 3 4 5 6 7 8 9 10

11

12

DI 1

DI 2

DI 3

DI 4

GN

D 1

-4

- -

SSR

1

SSR

2

SSR

3

MO

DEL: A

I4.1-yyCO

DE: 5000-03yy

CONN ECTOR C

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

SSR

4

COM

1-4

CONN ECTOR E

SSR OUTPUTS75 to 264 VACMax. 1A

24 V DIG. INPUTS Log. 0: -30 to 5 VLog. 1: 1 6 to 30 V

24-BIT ANALOG RTD INPUTSModes: 3-wire or 2-wire, Sampling: 1 kSpsRTD IN 1

AIN

+

RTD IN 2 RTD IN 3 RTD IN 4

*To Be Determined

Page 12: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 12/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of 8-bit Alarm / Digital 5V Inputs

v 8x 8-bit Alarm / Digital 5V Inputs

v 3x Digital 5V Inputs

v 1x NOC 24V Relay Output

v 2x Open Collector NPN Outputs

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

To next module

Auxiliary output 12 VDC, 100 mA

DIN35 installation Flat surface installation

BI8.1

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

24 VDC

5 VDC

NAME CODE NOTE

BI8.1-01 5000-0401 2x RS485

BI8.1-01G 5000-0402 2x RS485 (isolated)

BI8.1-07G 5000-0409 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

NAME CODE NOTE

BI8.1-01 5000-0401 2x RS485

BI8.1-01G 5000-0402 2x RS485 (isolated)

BI8.1-07G 5000-0409 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

10 to 60 VDC

RS485, 1-Wire...For complete

information about COM modules

please see www.iplog.eu.

Galvanic isolationGalvanic isolation

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

S

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

S

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

S

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ IN

PU

TS 5

V Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ IN

PU

TS 5

V Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ IN

PU

TS 5

V Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µs

DIG

. IN

PU

TS

5 V

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µs

DIG

. IN

PU

TS

5 V

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µs

DIG

. IN

PU

TS

5 V

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

1 2 3 4 5 6 7 8 9 10

11

12

BI 5

GN

D

BI 6

BI 7

GN

D

BI 8

OC

1

OC

2

GN

D

NO

1

CO

M

NC

1

1 2 3 4 5 6 7 8 9 10

11

12

VCC

OC

BI 1

GN

D

BI 2

BI 3

GN

D

BI 4

IN 1

IN 2

GN

D

MO

DEL: B

I8.1-yy

COD

E: 5000-04yy

CONN ECTOR C

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

IN 3

GN

D

CONN ECTOR E

DIGIT. 5V INPUTSLog. 0: 0 V to 0.8VLog. 1: 2 V to 5V

ALARM / 5V INPUTSMax. 7 VDC200 to 30.000

O

U

T

RELAY1A/24VDC

NPN OUTPUT16V / 0.2A

ALARM / 5V INPUTSMax. 7V DC200 to 30 000

*To Be Determined

Page 13: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 13/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of Relay OutputsRE8.1

v 8x NO 230V relay

v 3x optically separated 230V inputs

v 2x NOC 230V relay

v 1x Slot for COM IO Module

v Operating range °C to +70°C

v 600 W integrated surge protectionsDIN35 installation Flat surface installation

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

SWITCHING HV RELAYS Type 1

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

CHANGEOVER HV RELAYS Type 3

Rated Current 10 A Peak 15 A

Rated Load AC1 Max. 2500 VA

Rated Load AC15 Max. 500 VA 230 V AC

1-phase Motor rating Max. 0.37 kW 230 V AC

DC1 Breaking capacity 10/0.3/0.12 30/110/220 VA

REL

AY

S

Parameter Value Note

SWITCHING HV RELAYS Type 1

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

CHANGEOVER HV RELAYS Type 3

Rated Current 10 A Peak 15 A

Rated Load AC1 Max. 2500 VA

Rated Load AC15 Max. 500 VA 230 V AC

1-phase Motor rating Max. 0.37 kW 230 V AC

DC1 Breaking capacity 10/0.3/0.12 30/110/220 VA

REL

AY

S

Parameter Value Note

SWITCHING HV RELAYS Type 1

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

CHANGEOVER HV RELAYS Type 3

Rated Current 10 A Peak 15 A

Rated Load AC1 Max. 2500 VA

Rated Load AC15 Max. 500 VA 230 V AC

1-phase Motor rating Max. 0.37 kW 230 V AC

DC1 Breaking capacity 10/0.3/0.12 30/110/220 VA

REL

AY

S

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: max. 120 V AC

Log. 1: min. 200 V AC

Max. Input Voltage Max. 250 V AC / 1s

Input Current Typ. 6 mA at log. 1

Delay log.0 – 1 Typ. 10 msDIG

ITA

L IN

PU

TS

23

0 V Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: max. 120 V AC

Log. 1: min. 200 V AC

Max. Input Voltage Max. 250 V AC / 1s

Input Current Typ. 6 mA at log. 1

Delay log.0 – 1 Typ. 10 msDIG

ITA

L IN

PU

TS

23

0 V Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: max. 120 V AC

Log. 1: min. 200 V AC

Max. Input Voltage Max. 250 V AC / 1s

Input Current Typ. 6 mA at log. 1

Delay log.0 – 1 Typ. 10 msDIG

ITA

L IN

PU

TS

23

0 V Parameter Value Note

20 to 60 VDC

To next module

230VACL1 N

L1

L2

L3

N

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

230VACL2 N

230 VNL

1 2 3 4 5 6 7 8 9 10

11

12

HV

NO

9

CO

M 9

HV

NC

9

HV

NO

10

CO

M 1

0

HV

NC

10

HV

IN1

HV

IN1

HV

IN2

HV

IN2

HV

IN3

HV

IN3

1 2 3 4 5 6 7 8 9 10

11

12

- -

HV

NO

1

HV

NO

2

HV

NO

3

HV

NO

4

COM

1-4

HV

NO

5

HV

NO

6

HV

NO

7

MO

DEL: R

E8.1-yyCO

DE: 5000-05yy

CONNECTOR C

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONNECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

HV

NO

8

COM

5-8

CONN ECTOR E

RELAYS5A / 250 VAC3A / 30 VDC

DIGITAL INPUTS 230VLog. 0: Max. 120 VAC Log. 1: 2 00 - 240 VAC

230 V RELAYSRated Current: 10 A Peak: 15 A

CONN ECTOR A

NAME CODE NOTE

RE8.1-01 5000-0501 2x RS485

RE8.1-01G 5000-0502 2x RS485 (isolated)

RE8.1-07G 5000-0509 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

NAME CODE NOTE

RE8.1-01 5000-0501 2x RS485

RE8.1-01G 5000-0502 2x RS485 (isolated)

RE8.1-07G 5000-0509 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

*To Be Determined

Page 14: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 14/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of 12-bit Analog OutputsAO8.1

v 8x 12-bit Analog Outputs

v 4x 12-bit Analog U/I Inputs

v 4x Digital 24V Inputs

v 1x Slot for COM IO Module

v Operating range °C to +70°C

v 600 W integrated surge protections

NAME CODE NOTE

AO8.1-01 5000-0601 2x RS485

AO8.1-01G 5000-0602 2x RS485 (isolated)

AO8.1-07G 5000-0609 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

DIN35 installation Flat surface installation

20 to 60 VDC

To next module

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

+ +

± ± ± ±

+ +

± ±

Any combination of the voltage

or current modes 24 VDC

OR

DER

ING

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

0-10V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y + 0-10

V

G

Y +

Voltage Ranges 0V to 5V, 0V to 10V, ± 10V

Output current Max. 10 mA

Sampling Rate 100 kSps

Resolution 12-bit

Galvanic Separation No

Surge Protection 600 W 10/1000 µs

AN

ALO

G O

UTP

UT

S

Parameter Value Note

Voltage Ranges 0V to 5V, 0V to 10V, ± 10V

Output current Max. 10 mA

Sampling Rate 100 kSps

Resolution 12-bit

Galvanic Separation No

Surge Protection 600 W 10/1000 µs

AN

ALO

G O

UTP

UT

S

Parameter Value Note

Voltage Ranges 0V to 5V, 0V to 10V, ± 10V

Output current Max. 10 mA

Sampling Rate 100 kSps

Resolution 12-bit

Galvanic Separation No

Surge Protection 600 W 10/1000 µs

AN

ALO

G O

UTP

UT

S

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: V to 5 V

Log. 1: 16 V to 30 V Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. 100Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

T 2

4 V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: V to 5 V

Log. 1: 16 V to 30 V Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. 100Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

T 2

4 V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage Log. 0: V to 5 V

Log. 1: 16 V to 30 V Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. 100Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

T 2

4 V

Parameter Value Note

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Voltage Ranges ±2.5V, ±5V, ±10V

0V to 5V, 0V to 10V

Current Ranges 0 to 20mA, 4 to 20mA

Sampling Rate 10 kSps Adaptive

Resolution 12-bit

Galvanic Separation Yes

Surge Protection 600 W 10/1000 µs

AN

ALO

G I

NP

UT

S

Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

1 2 3 4 5 6 7 8 9 10

11

12

AO

1

AO

2

AO

3

AO

4

AG

ND

AO

5

AO

6

AO

7

AO

8

GN

D

1 2 3 4 5 6 7 8 9 10

11

12

AI 1

AI 2

AI 3

AI 4

AG

ND

DI 1

DI 2

DI 3

DI 4

GN

D

MO

DEL: A

O8.1-yy

COD

E: 5000-06yy

CONN ECTOR C

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

CONN ECTOR E

DIG. 24 V INPUTS Log. 0: -30 V - 5 VLog. 1: 1 6V - 30 V

ANALOG INPUTS±10 V, 0V to 10V 0(4) to 20mA

12-BIT ANALOG OUTPUTSVoltage Ranges: 0 V to 5 V, 0 V to 10 V, ±10 VMax. Load: 10mA, Sampling Rate: 1 00 kSps

VO

UT

POWERMax. 100 mA

PE

GN

D

*To Be Determined

Page 15: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 15/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of PUSH-PULL OutputsPP8.1

v 8x PUSH-PULL Transistor Outputs

v 4x 24 V Digital Inputs

v 3x 8-bit Alarm / Digital 5V Inputs

v 1x NOC 24V Relay Outputs

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

NAME CODE NOTE

PP8.1-01 5000-0701 2x RS485

PP8.1-01G 5000-0702 2x RS485 (isolated)

PP8.1-07G 5000-0709 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

DIN35 installation Flat surface installation

To next module

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

PUSH PULL OUTPUTSMAX. 50 VDC

24 VDC24 VDC

OR

DER

ING

10 to 60 VDC

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Output Type PUSH-PULL

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / 1 A

Max. Switching Freq. 10 kHz

Surge Protection 600 W 10 / 1000 µsPU

SH-P

ULL

OU

TPU

TS Parameter Value Note

Output Type PUSH-PULL

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / 1 A

Max. Switching Freq. 10 kHz

Surge Protection 600 W 10 / 1000 µsPU

SH-P

ULL

OU

TPU

TS Parameter Value Note

Output Type PUSH-PULL

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / 1 A

Max. Switching Freq. 10 kHz

Surge Protection 600 W 10 / 1000 µsPU

SH-P

ULL

OU

TPU

TS Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

DIG

ITA

L IN

PU

TS

24

V

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

1 2 3 4 5 6 7 8 9 10

11

12

DI 1

DI 2

DI 3

DI 4

GN

D

BI 1

BI 2

BI 3

GN

D

NO

1

CO

M

NC

1

1 2 3 4 5 6 7 8 9 10

11

12

V+ 1

-4

PP

1

PP

2

PP

3

PP

4

GN

D

V+ 5

-8

PP

5

PP

6

PP

7

MO

DEL: P

P8.1-yyCO

DE: 5000-07yy

CONN ECTOR C

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

PP

8

GN

D

CONN ECTOR E

PUSH-PULL OUTPUTSMax. 50V / 1 AProgrammable: NPN / PNP

RELAY0.5A/120VAC1A/24 VDC

ALARM / 5V INPUTS200 - 0 000

DIG. 24 V INPUTS Log. 0: -30 V - 5 VLog. 1: 1 6 V - 30 V

*To Be Determined

Page 16: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 16/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of Digital 24 V InputsDI8.1

v 8x 24 V Digital Inputs

v 4x NO 230V Relay Outputs

v 2x PUSH-PULL Transistor Outputs

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

NAME CODE NOTE

DI8.1-01 5000-0101 2x RS485

DI8.1-01G 5000-0102 2x RS485 (isolated)

DI8.1-07G 5000-0109 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

NAME CODE NOTE

DI8.1-01 5000-0101 2x RS485

DI8.1-01G 5000-0102 2x RS485 (isolated)

DI8.1-07G 5000-0109 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

OR

DER

ING

DIN35 installation Flat surface installation

To next module

24 VDC

L N230 VAC

Max.50 VDC

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

24 VDC

VIN – current limited (polyswitch) output

OUTPUTSPUSH PULL PWM

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

10 to 60 VDC

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

SWITCHING HV RELAYS Type 1

REL

AY

S

Parameter Value Note

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

SWITCHING HV RELAYS Type 1

REL

AY

S

Parameter Value Note

Contact Type NO Normal open

Max. Load 5 A / 250 VAC Resistive load

3 A / 30 VDC Resistive load

Lifetime 100,000 operations

SWITCHING HV RELAYS Type 1

REL

AY

S

Parameter Value Note

Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

Parameter Value Note

DIG

ITA

L IN

PU

TS

24

V Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

Parameter Value Note

DIG

ITA

L IN

PU

TS

24

V Isolation Voltage 3750 Vrms Optocoupler

Input Voltage DC - AC Log. 0: V to 5 V

Log. 1: 16 V to 30 V

Input Voltage Max. 50 V / 1s

Input Current 6 mA at 24 VDC

Delay log.0 – 1 Max. 100μs

Switching Frequency Max. TBD* Hz 1:1 duty

Surge Protection 600 W 10 / 1000 µs

Parameter Value Note

DIG

ITA

L IN

PU

TS

24

V

Output Type NPN / PNP / PUSH-PULL

Software selectable

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / TBD* mA

Max. Switching Freq. TBD*

Surge Protection 600 W 10 / 1000 µs

PU

SH-P

ULL

OU

TPU

TS

Parameter Value Note

Output Type NPN / PNP / PUSH-PULL

Software selectable

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / TBD* mA

Max. Switching Freq. TBD*

Surge Protection 600 W 10 / 1000 µs

PU

SH-P

ULL

OU

TPU

TS

Parameter Value Note

Output Type NPN / PNP / PUSH-PULL

Software selectable

Galvanic Separation No

Shortcut Protection Yes - polyswitch

Maximum Load 50 V / TBD* mA

Max. Switching Freq. TBD*

Surge Protection 600 W 10 / 1000 µs

PU

SH-P

ULL

OU

TPU

TS

Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

Output Type Max. 100 mA

Protection Diode + polyswitchPO

WE

R Parameter Value Note

*To Be Determined

Page 17: Industrial PLC System IPLOG - METELIndustrial PLC System IPLOG EN 60870-5-104 IEC 61131-3 4/17 e--e.. PARAMETER USB-A USB-B Standard USB 2.0 USB 2.0 IPLOG Mode USB host USB device

www.metel.eu 17/17 www.iplog.eu

EN 60870-5-104 IEC 61131-3

Pre

-pro

du

ction

da

tashee

t - Th

e pro

du

cer reta

ins th

e righ

t to ch

an

ge a

ny te

chn

ical p

aram

eters w

itho

ut p

revio

us w

ritten

no

tice..

Pre

-pro

du

ctio

n d

ata

shee

t -

Th

e p

rod

uce

r re

tain

s th

e r

igh

t to

ch

an

ge

an

y te

chn

ica

l pa

ram

ete

rs w

ith

ou

t p

revi

ou

s w

ritt

en

no

tice

..

Module of Analog / Alarm 8-bit OutputsBO8.1

v 8x Alarm Outputs 8-bit

v 3x 8-bit Alarm / Digital 5V Inputs

v 2x Open Collector NPN Outputs

v 1x NOC 24V Relay Output

v 1x Slot for COM IO Module

v Operating Range °C to +70°C

v 600 W Integrated Surge Protections

NAME CODE NOTE

BO8.1-01 5000-0801 2x RS485

BO8.1-01G 5000-0802 2x RS485 (isolated)

BO8.1-07G 5000-0809 RS485 + 1-Wire (isolated)

For a full range of interfaces please see www.iplog.eu.

DIN35 installation Flat surface installation

To next module

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

DE

VIC

E

Parameter Value Note

Power Supply 20 to 60 VDC Max. TBD* W

Operational Range 40 to +70 °C

Humidity Max. 95 % No-condensing

Dimension 35 x 110 x 119 mm W x H x D

Weight TBD* kg

Surge Protection 600 W 10/1000 µs

Installation DIN35 or flat surface

12 V

+5 VDC

INx

GN

DIN

xIN

xG

ND

INx

Alarm Panel

Alarm Panel

OR

DER

ING

10 to 60 VDCINx

GN

DIN

xIN

xG

ND

INx

RS485, 1-Wire...For complete

information about COM modules please

see www.iplog.eu.

Galvanic isolationGalvanic isolation

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

CHANGEOVER RELAYS Type 2

Max. Load 0.5 A at 120 VAC Resistive load

1 A at 24 VDC Resistive load

Lifetime 5,000,000 operations

REL

AY

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Digital Mode Log.0: 0V to 0.8V or 0 to 100Ω

Log.1: 2V to 5V or > 10kΩ

Analog (Alarm) Mode 200 to 30,000 Ω 8 ranges

Galvanic Separation No

Input Voltage Max. 7 VDC

Surge Protection 600 W 10 / 1000 µsALA

RM

/ 5

V I

NP

UTS

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

Output Type NPN

Maximum Load 16V / 0.2 A

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µsNP

N O

UT

PU

TS

Parameter Value Note

ALA

RM

OU

TPU

TS

Parameter Value Note

Output Type 8 bit 256 steps

Resistive Range 200 to 50,000 Ω

Accuracy ± 20 %

Temp. Dependence 50 ppm

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µs

ALA

RM

OU

TPU

TS

Parameter Value Note

Output Type 8 bit 256 steps

Resistive Range 200 to 50,000 Ω

Accuracy ± 20 %

Temp. Dependence 50 ppm

Galvanic Separation No

Surge Protection 600 W 10 / 1000 µs

1 2 3 4 5 6 7 8 9 10

11

12

NO

1

CO

M

NC

1

1 2 3 4 5 6 7 8 9 10

11

12

-

BO

1

GN

D

BO

2

BO

3

GN

D

BO

4

BLI 1

BLI 2

GN

D

MO

DEL: B

O8.1-yy

COD

E: 5000-08yy

CONN ECTOR A

1 2 3 4 5P

E

CONN ECTOR B

1 2 3 4 51 2 3 4 5

CONN ECTOR D

GN

D

VIN

10-6

0 V D

C

ww

w.iplo

g.eu

BLI 3

GN

D

CONN ECTOR E

ALARM / 5V INMax. 7V DC200 to 30 000

ALARM OUTPUTS8-bit, 256 Steps200 to 50 000

RELAY0.5A-120VAC1 A/24V DC

ALARM OUTPUTS8-bit, 256 Steps200 to 50 000

NPN OUTPUT16V / 0.2A

CONN ECTOR C

BO

5

GN

D

BO

6

BO

7

GN

D

BO

8

NPN OUTPUT16V/0.2 A

OC

2

OC

1

GN

D

*To Be Determined