GENVI SOLENOID VALVE - l'Hybride

2
® ELECTRO-FLUIDIC SYSTEMS P R O D U C T D A T A S H E E T PDS 179 8/19 © 2019 The Lee Company The Lee Company 2 Pettipaug Road, PO Box 424, Westbrook, Connecticut 06498-0424 Tel: 860-399-6281 Fax: 860-399-7037 www.theleeco.com GENVI SOLENOID VALVE Introducing the genvi™ LGV Series control valves, a new generation of versatile and innovative 3-port solenoid valves, offering high flow rates and low power in a minia- ture, 10mm package. Utilizing innovative manufacturing techniques, this novel family of valves is designed to offer application versatility and unmatched reliability at an economical price point. The genvi solenoid valve challenges the limitations of current fluidic technologies by allowing designers to use a miniature, low power solenoid valve without compromis- ing system-level flow rate requirements. The new valve is capable of achieving minimum flow rates of 30 to 40 SLPM at 15 psid, and its spike and hold drive profile results in ultra-low power consumption (318 mW) during continuous duty opera- tion. This reduces system-level heating and improves battery life, making it ideal for challenging power budgets. The new genvi solenoid valves are ideal for molecular diagnostics, oxygen delivery, environmental monitors, compression therapy, breath analyzers and numerous other applications where high flow and low power cannot be sacrificed for size and reli- ability. Contact your Lee Sales Engineer for additional technical assistance and application information. * Common to Normally Open Port ** Common to Normally Closed Port See dimensional drawings on reverse. High flow capacity Low power consumption: 318 mW (hold power) Leakage: 25 SμLPM (max) at 15 psid (air) Style: face mount Operating temperature range: 40°F to 120°F Response time: less than 10 ms Cycle life: 25 million cycles (minimum) Spike and hold drive required (Ref. Lee drawing #LFIX1002250A for schematic) Flow media: air and compatible gases Wetted materials: PC, 400 Series SS, Brass, PBT, FKM, 300 Series SS PART NUMBER VOLTAGE (Vdc) LOHM RATE ON AIR AT 70°F (21°C) OPERATING PRESSURE LGVA1221220D 12 Vdc Spike 2.75 Vdc Hold 200-250 Lohms (30 - 40 SLPM at 15 psid; Ref. Cv = 0.08 – 0.1) Supply: Vac to 45 psig Differential: 15 psid max. The Lohm is a measure of flow resistance. The referenced Lohm rate is dependent on the flow path; Common to Normally Closed or Normally Open Ports. Additional information can be found at www. theleeco.com. Flow Performance Characteristics 0 2.5 5 7.5 10 12.5 15 0 5 10 15 20 25 30 35 40 45 Air Flow (slpm) Differential Pressure (psid) 200 Lohms** 250 Lohms* PORTING FLOW SCHEMATIC DE-ENERGIZED ENERGIZED ISO 1219 SYMBOL OPEN OPEN INLET INLET CLOSED CLOSED NC COM NO

Transcript of GENVI SOLENOID VALVE - l'Hybride

Page 1: GENVI SOLENOID VALVE - l'Hybride

®ELECTRO - FLUIDIC SYSTEMSP R O D U C T D A T A S H E E T

PDS 179 8/19© 2019 The Lee Company

The Lee Company • 2 Pettipaug Road, PO Box 424, Westbrook, Connecticut 06498-0424Tel: 860-399-6281 • Fax: 860-399-7037 • www.theleeco.com

GENVI™SOLENOID VALVEIntroducing the genvi™ LGV Series control valves, a new generation of versatile and innovative 3-port solenoid valves, offering high � ow rates and low power in a minia-ture, 10mm package. Utilizing innovative manufacturing techniques, this novel family of valves is designed to offer application versatility and unmatched reliability at an economical price point.

The genvi solenoid valve challenges the limitations of current � uidic technologies by allowing designers to use a miniature, low power solenoid valve without compromis-ing system-level � ow rate requirements. The new valve is capable of achieving minimum � ow rates of 30 to 40 SLPM at 15 psid, and its spike and hold drive pro� le results in ultra-low power consumption (318 mW) during continuous duty opera-tion. This reduces system-level heating and improves battery life, making it ideal for challenging power budgets.

The new genvi solenoid valves are ideal for molecular diagnostics, oxygen delivery, environmental monitors, compression therapy, breath analyzers and numerous other applications where high � ow and low power cannot be sacri� ced for size and reli-ability. Contact your Lee Sales Engineer for additional technical assistance andapplication information.

* Common to Normally Open Port ** Common to Normally Closed Port

See dimensional drawings on reverse.

■ High � ow capacity

■ Low power consumption: 318 mW (hold power)

■ Leakage: 25 SμLPM (max) at 15 psid (air)

■ Style: face mount

■ Operating temperature range: 40°F to 120°F

■ Response time: less than 10 ms

■ Cycle life: 25 million cycles (minimum)

■ Spike and hold drive required (Ref. Lee drawing #LFIX1002250A for schematic)

■ Flow media: air and compatible gases

■ Wetted materials: PC, 400 Series SS, Brass, PBT, FKM, 300 Series SS

PART NUMBER VOLTAGE(Vdc)

LOHM RATEON AIR AT 70°F (21°C) OPERATING PRESSURE

LGVA1221220D12 Vdc Spike2.75 Vdc Hold

200-250 Lohms(30-40 SLPM at 15 psid;

Ref. Cv = 0.08 – 0.1)

Supply: Vac to 45 psigDifferential: 15 psid max.

The Lohm is a measure of flow resistance. The referenced Lohm rate is dependent on the � ow path; Common to Normally Closed or Normally Open Ports. Additional information can be found at www.theleeco.com.

Flow Performance Characteristics

0

2.5

5

7.5

10

12.5

15

0 5 10 15 20 25 30 35 40 45

Air Flow (slpm)

Diff

eren

tial P

ress

ure

(psi

d)

200 Lohms**

250 Lohms*

PORTING FLOW SCHEMATICDE-ENERGIZED

ENERGIZED

ISO 1219 SYMBOL

OPEN

OPEN

INLET

INLET

CLOSED

CLOSED

NC

COM

NO

Page 2: GENVI SOLENOID VALVE - l'Hybride

PDS 179 8/19© 2019 The Lee Company

The Lee Company • 2 Pettipaug Road, PO Box 424, Westbrook, Connecticut 06498-0424Tel: 860-399-6281 • Fax: 860-399-7037 • www.theleeco.com

2X .44 11.3

3X .128 3.25

2X .44 11.0

2X .45 11.4

1.78 45.1

3X .03 0.8.39 9.8

.53 13.5

2X .22 5.6

.20 5.12X CONTACT PIN

.025 [0.64]

.40 10.2

COMMON PORT

NORMALLY CLOSED (N.C.) PORT

NORMALLY OPEN (N.O.) PORT2X #2-56 MOUNTING SCREW LOCATION

GENVI™ SOLENOID VALVE

PART NUMBER DESCRIPTION

LEDX0501200B Spike and Hold Driver with Protective Cover

LFMX0532700B Ported Adapter allows for connection to 1/8" ID tubing

LFKX0502950ASpike and Hold Kit: includes driver board with cover, twoscrews, mounting screw support and LLWX0504290A lead wire connector

LFKX0503000APort Adapter Kit: includes LGVA1221220D valve, ported adapter, two screws, mounting screw support and tubing. Units are shipped fullyassembled and tested, except tubing.

LFKX0503050A

Spike and Hold with Port Adapter Kit: includes LGVA1221220D valve, driver board with cover, ported adapter, two screws, mounting screw support, tubing and LLWX0504290A lead wire connector. Units are shipped fully assembled and tested, except tubing and lead wire.

The Lee Company offers several genvi™ accessory kits and components, including electrical connectors, tubing, tubing adapters and spike and hold drivers.

Mounting Screw (LLWX0213020A)

Mounting ScrewSupport(LGVX0300290A)

3x O-RINGINCLUDED

Face Mount Boss Detail

Reference Drawing Number LFIX1002400A for Face Mount Boss Details.NOTE: Drawings above not to scale. All dimensions are in inches [mm].

.20 [ 5.1 ]

.40 [ 10.2 ]

.40[ 10.2 ]

2X .30 [ 7.6 ]

NORMALLY OPEN(N.O.) PORT

COMMON PORT

NORMALLY CLOSED(N.C.) PORT

2X #2 OR M2 THREAD .290 MIN FULL THREAD

.20 MIN [ 5.1 MIN ](SEALING SURFACE)

.20 [ 5.1 ]

3X ø .141 [ 3.57 ] .040 MIN [ 1.02 MIN ]

ACCESSORIES

MOUNTING HARDWARE SOLD SEPARATELY