GARANTIA - AbaTec
of 45
/45
Embed Size (px)
Transcript of GARANTIA - AbaTec
+52 (33) 36 20 12 14 +52 (33) 36 20 12 15 +52 (55) 49 09 75 81
(cotizacion 24 / 7)
[email protected] [email protected]
GARANTIA
BIOSEGURIDAD
FOLLETO
+52 (33) 36 20 12 14 +52 (33) 36 20 12 15 +52 (55) 49 09 75 81 (cotizacion 24 / 7)
[email protected] [email protected]
https://www.abatec.com.mx/nuaire/
Disponibles con entrega inmediata NU-540-300 3 pies (0.9144m) NU-540-400 4 pies (1.2192m)
NU-540 Clase II Tipo A2
Gabinete de BioSeguridad
NU-560 Clase II Tipo B2
Disponibles con entrega inmediata NU-NRE800-600 6 pies (1.8m)
AISLADOR FARMACEUTICO
Horizontal Airflow Style: Console
CLASS II BIOSAFETY CABINET (BSC)
Type A2 70% Recirculated / 30 % Exhausted No Requirement to Externally Vent
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
Compounding Aseptic Isolator (CAI) Positive Pressure Recirculating
UNCLASSIFIED NO AIR CHANGES NEEDED
SEGREGATED COMPOUNDING AREA
ISO CLASS 7 CLEAN ROOM
+
+
+
+
+
+
+
+
+
+
≤24 Hrs if Refrigerated BUD ≤ 12 hrs
>24 Hrs if Refrigerated BUD > 12 hrs
CATEGORY 2 Beyond Use Date (BUD))
s BBBB BB
CONTAINMENT PRIMARY ENGINEERING CONTROL
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
ENTS
Negative Pressure Recirculating Canopy Connected External Vent
Compounding Aseptic Containment Isolator (CACI)
Negative Pressure Total Exhaust Hard Connection External Vent
Type B1 30% Recirculated /
70% Exhausted Hard Connection
ISO CLASS 7
NEG. PRESSURE 0.01” - 0.03” WC NEG. PRESSURE 0.01” - 0.03” WC
STERILE
≤24 Hrs if Refrigerated BUD ≤ 12 hrs BUD > 12 hrs
CATEGORY 2 Beyond Use Date (BUD)
>24 Hrs if Refrigerated
CONTAINMENT PRIMARY ENGINEERING CONTROL
EXTERNALLY VENTED OR REDUNDANT HEPA FILTER EXHAUST INTO ROOM
CLASS II BIOSAFETY CABINET (BSC) EXTERNALLY VENTED
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
EXTERNALL
OR
OR
Canopy Connected Exhaust
Exhaust into Room through Redundant HEPA Filters h t i t R th
Redundant HEPA Filters
Negative Pressure Recirculating Canopy Connected External Vent
Compounding Aseptic Containment Isolator (CACI)
Negative Pressure Total Exhaust Hard Connection External Vent763.553.1270 | NUAIRE.COM
Glove ports are used to provide physical separation between the surrounding area and the aseptic manipulations. If used to prepare Category 2 CSPs, the area surrounding the RABS must meet ISO Class 7 or better air quality.
All transport ports on the RABS must be closed during compounding. When a RABS is used, the recovery time after opening to achieve ISO Class 5 air quality must be documented, and internal procedures must be developed to ensure that adequate recovery time is allowed after opening and closing the RABS, both before and during compounding operations.
RESTRICTED ACCESS BARRIER SYSTEM (RABS) Provides isolation from the surrounding area and maintains ISO Class 5 air quality during typical operating conditions.
The following standards must be met to qualify as an isolator:
• High-integrity transfer ports are used to move supplies, Ingredients, components, and devices into and out of the isolator.
• The isolator is decontaminated using a generator that distributes a sporicidal chemical agent throughout the isolator chamber.
• The isolator maintains constant overpressure of at least 0.05-inch water column.
• The manufacturer has provided documentation that the isolator will continuously meet ISO Class 5 conditions, including during material transfer.
• A CAI or CACI is not an isolator.
ISOLATOR
FLOW CHART FOR USP 797 AND USP 800 PEC REQUIREMENTS
ACPH - Air Changes per Hour BUD - Beyond Use Date BSC - Biosafety Cabinet CACI - Compounding Aseptic Containment Isolator CAI - Compounding Aseptic Isolator C-PEC - Containment Primary Engineering Control C-SCA - Containment Segregated Compounding Area C-SEC - Containment Secondary Engineering Control CSP - Compounded Sterile Preparation CVE - Containment Ventilated Enclosure LAFW - Laminar Airflow Workstation PEC - Primary Engineering Control RABS - Restricted Access Barrier System SCA - Segregated Compounding Area SEC - Secondary Engineering Control
Glossary
Sources
USP General Chapter <800> Hazardous Drugs– Handling in Healthcare Settings. (2017). The United States Pharmacopeial Convention.
General Chapter <797> Pharmaceutical Compounding – Sterile Compounding. (n.d.). The United States Pharmacopeial Convention.
20-1389-I-D-EN-4-1018
A CAI is designed for compounding non-HD CSPs. It is designed to maintain an ISO Class 5 environment throughout the compounding and material transfer processes. Air exchange into the CAI from the surrounding environment must not occur unless the air has first passed through a HEPA filter.
COMPOUNDING ASEPTIC ISOLATOR (CAI)
TYPES OF RABS
A CACI is designed to provide worker protection from exposure to undesirable levels of airborne drug throughout the compounding and material transfer processes, and to maintain an ISO Class 5 environ- ment for compounding sterile HD preparations. Air exchange with the surrounding environment must not occur unless it is first passed through a HEPA filter capable of containing airborne concentrations of the physical size and state of the drug being compounded.
COMPOUNDING ASEPTIC CONTAINMENT ISOLATOR (CACI)
DESIGNED BY YOU. DESIGNED FOR YOUR APPLICATION.
NU-540 CLASS II TYPE A2 BIOLOGICAL SAFETY CABINET
NuAire, Inc. | 2100 Fernbrook Lane | Plymouth, MN 55447 | U.S.A. | nuaire.com
For more information please visit www.nuaire.com or call 1-763-553-1270
There is a Perfect Fit for You
3 FOOT 4 FOOT 6 FOOT5 FOOT
You deserve a quality and robust Biological Safety Cabinet every time you sit down for work. NuAire Biological Safety Cabinets
are designed to last. Every NuAire Biological Safety Cabinet goes through a series of checks before it reaches your laboratory.
As your product moves through the assembly plant, each work station double checks the work of the previous station, filters
are tripled check, and biological tests are constantly being performed under dynamic conditions to ensure maximum safety.
Each cabinet is built to order for your application. It is as simple as including an additional service valve or as complex as
developing the interior to fit a specific piece of machinery.
Our local sales representatives are the best in the industry. They assist with product selection, review built-in options and
accessories, discuss pricing, offer installation guidance, and provide support over the life of your NuAire product.
Designed By You. Designed for your Application.
NU-540
is a Class II, Type A2 Biological Safety Cabinet
offering Personnel, Product, and Environmental
Protection through the use of quality design,
an ultra high efficiency motor, and longer
lasting filters all at an affordable price.
Join the NuAire family of over 100,000
Biological Safety Cabinets in use throughout
the world and learn why NuAire offers the
longest lasting, lower cost, and safest
Biological Safety Cabinet in the world.
NU-540
6” (152 mm)
- Recessed air foil
- Recessed work zone
- More knee room
- Ability to sit or stand at a range of heights
- 21” (533 mm) frame-less edge window sash improves vision/sight lines into work zone
- Staggered service valves
- Accessories (elbow rests, armrest foam pads, ergo chair, adjustable base stand, sst turntable)
Ergonomic Design
NuAire designs equipment that accommodates advancement for: improved safety conditions; improved productivity;
improved quality and reliability; and reduction of arm, shoulder, and neck strain contributing to common work place injuries.
NU-540
Wrists Straight90
23”-28”Adjustable Seat Height
[ Larger Work Area ]
[ Expanded Vision Zone ]
[B]
[A]
Monolithic Design. At core of any biosafety cabinet is its basic structure. NuAire has over 100,000 biological
safety cabinets in the field; some of which have been running strong since the 1970’s.
The NuAire design is a single piece of type 304 stainless steel. A stainless steel wrap [A] makes up the walls
of the cabinet. Stainless steel sheets [B] are welded in place to make up the top and bottom of the cabinet. A
smaller wrap [C] featuring coved interior corners is welded in place to make up the back wall of the cabinet.
This improves the cabinet integrity by creating a double sidewall. New work tray supports [D] help minimize
the vibration transfer from the shell of the cabinet to the work zone.
The end result is a monolithic shell of 100% stainless steel [E] without the use of silicone like many multi-piece
cabinets. This provides you with a solid foundation for longer product life eliminating potential leaks.
[D][C]
Save More Money Over a Longer Period of Time
Ultra High Efficiency Motor. An ultra-high efficiency ECM motor combined with the properly sized
fan blade lowers energy usage while extending the life of filters. LabGard® offers the lowest total
cost of ownership compared to other models.
* estimate based on Filter Load capacity ** estimate based on historical information. Disclaimer: This example is for illustrative purposes only and should not be deemed a representation of future performance or a guarantee of any kind. Information is based on internal performance data obtained through NuAire® testing and information provided by motor, blower, HEPA filter manufacturers, and independent service technicians.
Total cost of ownership breakdown. Motor Comparison NuAire DC ECM NuAire AC PSC BSC with AC 3-Phase BSC with DC
8 hrs per day / 5 days per week = 2,000 hrs per year
KWH per year 598 1128 828 326
$0.09/kwh $54 $102 $75 $29
24 hrs per day / 7 days per week = 8,736 hrs per year
KWH per year 2612 4927 3617 1424
$0.09/kwh $235 $443 $326 $128
15 Year Life Cycle Costs
Avg. Filter Changes* 1 Set 2 Sets 1 Set 3 Sets
Estimated Cost of HEPA Filters $715 $1,430 $715 $2.145
Total Cost of Decon/Certification $450 $900 $450 $1,350
Motors to Replace** 1 Motor 1 Motor 1 Motor 2 Motors
Cost of Motors/ Power Supplies/ Fan Control
$650 $420 $725 $2,544
$810 $1,530 $1,125 $435
NU-540
by operating environment
Software/Hardware Watchdog - automatically reset upon failure to last known status or to
blower “ON” to assure containment.
Software updates via USB
maintaining work zone sterility.
AeroMax Electronic Control System (ECS) monitors and displays airflow system performance via
PresurFlow™ - A specialized digital pressure transducer.
Visual Alarm Visual status alarm:
Green Normal Operation Yellow Near Alarm Status
Red Status Alarm
Outlet(s) On/Off
Up Value Down Value
Alarms. An audible alarm will sound for 30 continuous seconds then ring back for one second every five seconds until silenced or the alarm
condition is cleared. If Silence is pressed, the Silenced alarm condition will be blocked from repeating for a period of 15 minutes.
NU-540
8
NuAire’s commitment to safety doesn’t stop at meeting industry standards. NuAire continually performs dynamic tests to
push the limits of our product’s performance to ensure you and your laboratory personnel will remain safe.
Automatic Airflow Compensation - the Ultra High Efficiency motor will automatically increase or decrease speed to maintain
proper airflow settings based on readings from AeroMax ECS.
Your Safety is Our Number 1 Priority
True laminar (unidirectional) downward moving air flushes the
work surface at 60 fpm (0.30 m/s) minimizing cross contamination.
A dynamic air barrier at the front of the cabinet separates the laboratory
from the work zone environment at an air speed of 105 fpm (0.53 m/s).
The HEPEX Zero Leak Airflow system evenly disperses air over the supply and exhaust
HEPA filters, minimizes vibration transfer, and eliminates potential leaks by surrounding positive
pressure chambers with negative pressure.
Air Split
9
We at NuAire® have designed each LabGard® Biosafety Cabinet to be service friendly. 100% of service functions can be
performed at the front or top of the cabinet.
Drop Down Control Panel
tray for service technicians.
Front Filter Access
of the cabinet with the removal of a safety panel.
Decon101 System
systems that use Formaldehyde, Chlorine Dioxide
or Vapor Phase Hydrogen Peroxide
Make it Easier on your Service Personnel
NU-540
Sustainability
At NuAire we continually strive to improve our responsibilities to the economy, environment, social communications, and
our customer satisfaction. Our commitment extends to purchasing or using products that reduce energy consumption,
reduce environmental impact, minimize pollution and make use of recycled content that will not deplete natural resources.
We continually use more recycled materials in our cabinets through both design and supplier parts and process improve-
ments. The following chart represents our current level of sustainability for Biological Safety Cabinets.
General Cabinet % Content by Weight % of Recycled Material % Recyclable Component Description used in Manufacturing
Stainless Steel 75% 80% 100%
Mild Steel 10% 10% 100%
Copper 2% 0% 100%
Aluminum 2% 50% 100%
Glass 3% 0% 100%
Electronics 1% 0% 25%
Misc. Plastic Parts 1% 0% 0%
Packing Materials 5% 60% 95%
100% BSC 65% 97%
Net Weight
[ 873 x 654 x 724 ]
41 5/8 x 31 7/16 x 61 7/8
[ 1057 x 799 x 1572 ]
400 lbs
[ 181 kg ]
[ 1178 x 654 x 724 ]
53 5/8 x 31 7/16 x 61 7/8
[ 1362 x 799 x 1572 ]
465 lbs
[ 211 kg ]
[ 1483 x 654 x 724 ]
65 5/8 x 31 7/16 x 61 7/8
[ 1669 x 799 x 1572 ]
550 lbs
[ 249 kg ]
[ 1788 x 654 x 724 ]
77 5/8 x 31 7/16 x 61 7/8
[ 1972 x 799 x 1572 ]
620 lbs
[ 281 kg ]
Specifications
Specifications
The LabGard ES is a Class II Type A2 Biological Safety Cabinet that can be either exhausted back into the room
or connected to a facility HVAC system. The cabinet’s airflow is 30% exhausted / 70% recirculated to minimize cross-
contamination of low to moderate risk biologicals in the absence of volatile toxic chemicals.
WARRANTY - Best products backed by the best warranty.
5 Parts (Filters Included) & Labor (US & CA)
6 Years Parts (Filters Included) (Intl)
10” (254 mm)
8” (203 mm)
NU-540
60 fpm (0.30 m/s) Down Flow
Filter Load Capacity 250% plus
Filter Life +- 10 Years
Attenumont Vibration Control System
Permanent Plenum with Quick Release Supply Filter
3” (76 mm) Metal Frame Supply HEPA Filter 99.99% @ 0.3 microns
6” (152 mm) Metal Frame Exhaust HEPA Filter 99.99% @ 0.3 microns
Metal Diffuser Over Supply Filter
10” (254 mm) Window Sash Access Opening
Frame-less Sliding Tempered Glass View Window
External Fluorescent Lighting
Front Filter Removal
PVC Plastic Armrest
Removable Work Tray
Removable Airflow Grill
Two (2) Duplex Outlets Back Wall
One (1) Service Valve Right Side Wall
One (1) Service Coupling Right Side Wall
Two (2) Service Couplings Left Side Wall
12 ft. (2.5m) Power Cord
Optional Features and Accessories*:
Metal Frame Supply ULPA Filter 99.999% @ 0.12 microns
Metal Frame Exhaust ULPA Filter 99.999% @ 0.12 microns
Canopy Exhaust Transitions
IV Bar with Six (6) Hooks
Duplex Outlets
Additional Service Valves/Couplings Up to Three (3) Each Side Wall
Prop Up Work Tray
Telescoping Base Support Stand
Motorized Base Support Stand
Base Support Stand Shelf
Adjustable Footrest
Elbow Rests
Armrest Pads
Custom Solutions
Class II, Type A2 Air In-flow 70% Recirculated vs. 30% Exhausted
HEPA Filtered Air
Contaminated Worksurface Air
Contaminated Room Air
Air Split*Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
NU-540
Ultraviolet (UV) Light
Microscope Window Ergotron® arm for monitor and keyboard/mouse
Cord Pass-thru (NSF) LED Lighting (Replaces Florescent Lighting)
Duplex and/or GFI Outlets
Design Your Very Own
Each laboratory is unique and every protocol can differ. Set your laboratory up for success by designing your own NuAire Biological
Safety Cabinet. It can be as simple as adding a service valve or as involved as customizing the height of the work zone. NuAire
can do it all. Invest in a product that lasts and is designed for your needs.
Popular Built-in Options & Accessories
Airflow Alarms Laboratory Cart Silicone Connection Kit
Motorized Base Stand Base Stand ShelfTelescoping Leg Leveler or Castor Base Stand
Adjustable Foot Rest Stainless Steel Turntable
Options and Accessories
Flex Duct Manual and Automatic Butterfly Valves
8” (204 mm) to 10” (254 mm) Round Transition
Variable Flow Control (VFC) Exhaust Transition w/ Alarm
NU-540
Complete your Laboratory
NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.
Mini-Centrifuges
Compounding Isolators Animal Laboratory Products Polypropylene Fume Hoods
and Casework
17
Delivering product to the customer that is cost effective, exceeds their requirements, delivers product on-time, and increases
productivity and profitability.
In every NuAire product you’ll find brilliant but practical design, keen attention to detail in every phase of the fabrication and
assembly process, thoroughly tested, outstanding value, and dependable service. These are the foundation for NuAire’s inter-
national reputation, and practical reasons why NuAire is universally recognized as the finest. NuAire’s Quality Policy to Satisfy
Customers, Comply with Quality System Requirements and Continually Improve.
Sales and Service Like No Other NuAire employs a network of
knowledgable sales and service individuals some of which have been
selling and servicing NuAire Laboratory Products since our inception
in 1971.
Working safely video series. Learn how to work safely in your NuAire
Biological Safety Cabinet with this 7 Chapter online video series.
Our Sales Representatives are located throughout the globe
providing you with a local individual who can assist product
selection, pricing, installation, training, and service throughout the
life of your product. Once you buy a NuAire you’re a part of our
family and we’ll work hard to satisfy your needs.
NuAire offers service-training classes and individualize assistance
to service professionals in the laboratory community. These NuAire
certified companies are located throughout the world allowing
NuAire to provide service and assistance to the farthest corners of
the earth. Have the option to select from multiple service vendors in
your area to find a company that fits your needs.
Contracts, GPO’s and many more! NuAire has a variety of Contracts
set up through Group Purchasing Organizations, Government
Associations, Health Systems, Universities and many more.
ISO 9001:2008 Certificate ISO 13485 Certificate
NU-540
20-1315-B-D-EN-3-0516 Request a quote online
For more information please visit www.nuaire.com or call 1-763-553-1270
SHARE A PICTURE AND TAG YOUR NUAIRE BIOSAFETY CABINET USING #MYNUAIRE
Your Local NuAire Partner
NuAire® | 2100 Fernbrook Lane | Plymouth, MN 55447 | USA | 763-553-1270 | www.nuaire.com
© Copyright 2018 NuAire, Inc. All Rights Reserved
20-1459-F-D-EN-4-1218
NU-560 CLASS II TYPE B2 BIOSAFETY CABINET
The LabGard® ES (Energy Saver) TE (Total Exhaust) NU-560 Biosafety Cabinet (BSC) is available as a bench or table top cabinet designed to provide optimum control over product quality in the lab, while also reducing the risk of exposing the product or lab personnel to any airborne biological or particulate chemical agents. This cabinet -- which meets all requirements of a Class II, Type B2 cabinet -- is equipped with an energy-saving motor to maximize energy efficiency and filter loading capacity. As prescribed by the Center for Disease Control in Atlanta, Georgia, the cabinet is intended for use in low to moderate risk-hazard research and drug preparation or product operations.
Blower UV Light Fluorescent Light Outlet Timers Menu
Night setback mode is initiated by the window closure, will reduce motor / blower operational airflow to conserve energy while maintaining work zone sterility.
COMPONENTS
intelliflow™ airflow sensor technology incorporates the same thermal anemometer technology used by service technicians (certifiers) to annually verify your biological safety cabinet’s airflow performance.
Performance Features: • 100% exhausted • Dynamic air barrier of 105 linear fpm (0.54 m/s)
inflow separating laboratory from work zone environment
• True Laminar Unidirectional Down-flow air of 60 fpm (0.30 m/s) for minimal cross contamination
• 300% Filter Load Capacity for Supply HEPA only (±10 Year Average depending on laboratory environment)
• ISO Class 5 Clean Air
The NuAire TouchLink Touchscreen LCD Control Center brings Biosafety Cabinet performance to your fingertips. The TouchLink control center allows supervisors to control the blower by password, provides real-time airflow measurements
and alarms, and integrates quickly with current facility security systems. TouchLink also simplifies maintenance by providing detailed diagnostic information and step-by-step decontamination procedures. TouchLink can even wake up when you do—by running the blower and lights on a customizable schedule!
Real time Airflow
NuAire® | 2100 Fernbrook Lane | Plymouth, MN 55447 | USA | 763-553-1270 | www.nuaire.com
© Copyright 2018 NuAire, Inc. All Rights Reserved
20-1459-F-D-EN-4-1218
NU-560 CLASS II TYPE B2 BIOSAFETY CABINET
*Specify model with appropriate letter suffix for electrical specifications. “NU-560-400E” for 230 VAC / 50 - 60 Hz
Model Width Size (nominal) Electrical* (all sizes) Interior Dimensions
(W x D x H) in. [mm] Exterior Dimensions (W x D x H) in. [mm] Net Weight Exhaust
Requirement
E: 230 VAC / 50 Hz-60 Hz
46 3/8 x 26 x 25 3/16 [1178 x 660 x 640]
53 5/8 x 31 7/16 x 62 [1362 x 798 x 1575]
490 lbs [222 kg] 815 CFM @ 1.7 w.g.
NU-560-600 6 ft [1.8 m]
70 3/8 x 26 x 25 3/16 [1788 x 660 x 640]
77 5/8 x 31 7/16 x 62 [1972 x 798 x 1575]
680 lbs [308 kg] 1275 CFM @ 1.8 w.g.
Specifications
request online or scan the code.
Popular Accessories/Built-in Options
Prop Up Work Surface Ultraviolet (UV) LightArm Rest Pads Elbow RestMotorized Base StandTelescoping Leg Leveler or Castor Base Stand
NuAire is a sponsor of the IFBA
Standard Features
Ultra-high Efficiency Motor
Front Filter Removal
Metal Diffuser Over Supply Filter
3-inch (76mm) Supply HEPA Filter 99.99 @
0.3 Micron Efficiency Rating
12-inch (305 mm) Exhaust HEPA Filter 99.99 @ 0.3 Micron Efficiency Rating
Attenumont Vibration Control
Exterior LED Lighting
Frame-less Sliding Tempered Glass View Screen
Heavy Duty, Ergonomic Plastic Armrest
10 degree slope front
Power Cord
**Telescoping Base Stand Only
Bag In/Bay Out of Exhaust HEPA Filter with Single Point External Release
Ultraviolet Light
Additional Service Valves
IV Bar with 3 Locations, 6 Stainless Steel Hooks
Gas Tight Butterfly Valves (Manual or Automatic)
Sink with Hot/Cold or DI Water Faucets
Storage Pull-Out Trays
Decorative Side Panels
• Auto Filter Loading Compensation
Superior Construction Features: • Monolithic 16/18 Gauge, Type 304 Stainless Steel
Welded
• Removable Control Center
• Stainless Steel Spill Trough with Drain Valve
• Vibration Reducing Work Surface Support System
• External Non-Glare 110 lm/ft2 LED Lighting
Safety Features: • 3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron
Efficiency Rating
Microns Efficiency Rating
• Airflow / Window Alarms with Ring Back Function
• Security Password Protection
• NSF/ANSI 49, UL Listed
NuAire, Inc. | 2100 Fernbrook Lane | Plymouth, MN 55447 | U.S.A. | nuaire.com
For more information please visit www.nuaire.com or call 1.763.553.1270
1
2
NuAire PharmaGard Compounding Aseptic & Containment Isolators are engineered to maximize work productivity by providing a comfortable and ergonomically correct environment.
PharmaGard Compounding Aseptic (CAI) and Containment
(CACI) Isolators provide a sterile work environment for
the compounding of hazardous and non-hazardous drugs.
PharmaGard creates true HEPA filtered laminar airflow at
20 air changes per minute within both the work zone and
interchange areas to assure ISO Class 5 conditions. Utilizing
laminar flow assures a continuous stream of HEPA filtered air
across the work zone and interchange areas assuring sterility
and minimizes cross contamination. Once the air is through
the work area, the airflow is split from front to rear. The
airflow then proceeds under the work tray, up the rear divider
panel where it is recirculated or exhausted.
The PharmaGard PR is a Compounding Aseptic Isolator that meets the USP 797 Standard for aseptic compounding of non-hazardous drugs.
The PharmaGard NTE is a Compounding Aseptic Containment Isolator that meets the USP 800 Standard for handling hazardous drugs.
3
PharmaGard Compounding Aseptic and Containment Isolators offer the best possible user ergonomics.
Ergonomic features on the PharmaGard include:
Counter Balance Inner Transfer Window
The transfer window counter balance [B] is isolated from
sterile product inside the inter-chamber wall. The window
moves easily up or down with one finger. A security lock on
NR and NTE units ensures the inner transfer door remains
locked if the outer door is open.
Sliding Work Tray
Located in the transfer compartment, the sliding work tray [A]
provides a seamless transition when entering compounding
materials into the work zone. The stainless steel work tray
is mounted on ball bearing brackets to smoothly enter
compounding materials into the sterile work area.
[B]
[A]
4
Expanded Vision Zone and Work Zone
PharmaGard isolators offer greater visibility due to cool white lighting and open sight lines. The largest effective work zone [C]
helps reduce arm / neck / shoulder strain. Large oval glove ports [D] extend the reach of the user, and three IV bar locations
[E] provide proper compounding height/distance.
Ability to sit or stand at a range of heights
The isolator design maximizes knee/thigh clearance to
improve posture and the adjustable base stand allows for
optimization of leg and upper body support.
[D]
[E]
5
6
[A]
Sharps and Waste Disposal
The PharmaGard allows a user to dispose of waste and sharps directly from the sterile work zone. Two waste containers [A] are accessible through covered negative pressure drop tubes to maintain sterility inside the work area and containment on the isolator exterior.
Once a container has been filled and is ready for replacement, PharmaGard
allows the end user to individually change out each container when needed.
After the waste or sharps container lid has been sealed, follow these steps:
Step 1. Release locking mechanism by
pulling handle.
Remove container block.
and replace.
Documentation and Surveillance Training in the Pharmacy
US Pharmacopeia (USP) calls for the documentation of standard operating procedures (SOPs) and the development of a medical surveillance programs. NuAire has developed easy add-on accessories and built-in options to help with the documentation process.
Monitor and Keyboard/Mouse Arm
technicians to easily access and follow compounding SOPs.
Workflow documentation can be entered throughout the
compounding process.
Video Cameras
One or more cameras can be added to a PharmaGard back
wall or mounted to the front of the control panel to monitor
the healthcare worker, document compounding processes or
spill control procedures, etc.
work area by a glass panel can be added to
the back wall of a PharmaGard.
Video Surveillance Cameras
allows for the mounting of many different
types of cameras outside the cabinet.
9
Electronic Control System (ECS)
Each PharmaGard Electronic Control System (ECS) is designed for high user adoption. Easy to read on/off switches make
each PharmaGard simple to operate. Visual indication of system operations is shown through mini-helic gauges that monitor
pressures within the interchange and main chamber.
Compounding Aseptic Isolators (CAI)
The Pressure Monitor displays the positive static pressure within the main chamber. The pressure monitor is calibrated in
“inches of water gauge” pressure. The pressure monitor will read the same as the main chamber minihelic gauge and in
addition, allow a low/high alarm limit point to be set. The default alarm limits is set to 0.10” w.g. low and 0.50” w.g. high. See
optional equipment section for greater detail.
[A] The Blower key indicates and controls ON/OFF power to the blower.
[B] The Light key indicates and controls ON/OFF power to the fluorescent light.
[C] The UV Light key indicates and controls ON/OFF power to the UV light (optional).
[D] The Outlet key indicates and controls ON/OFF power to the outlets.
[E] The Enter key is used to select item on display or accept and enter current
item, function or value.
[F] The Silence key allows a user to silence an audible alarm for 15 minutes.
After 15 minutes if the alarm condition continues, the alarm will repeat.
[G] The FlowGard OLED screen displays a variety of cabinet functions as well as
display cabinet performance.
[H] The Arrow Adjustment keys allow user interaction for various functions.
[I] The Red Alarm LED indicates any alarm condition.
[I]
Compounding Aseptic Containment Isolators
(CACI) pressure. System operational health is displayed
visually through system LEDs. Each color represents specific
condition outlined below:
Green = Acceptable Pressure
Red = Alarm Condition
In the event of an Alarm Status a audible alarm will sound
notifying the end user the system no longer offers protection.
The PharmaGard Digital Monitor comes standard on models
NU-NR800 and NU-NTE800 and is an optional upgrade on
model NU-PR797.
The PharmaGard Pressure Monitor displays the negative static pressure with- in the main chamber. The pressure monitor is calibrated in “inches of water gauge” pressure. The pressure monitor will read the same as the main chamber minihelic gauge and in addition, allow a low/high alarm limit point to be set. The default alarm limits is set to - 0.05” w.g. high and - .50” w.g. low.
[I]
[C][B][A]
[A] The Blower key indicates and controls ON/OFF power to the blower.
[B] The Light key indicates and controls ON/OFF power to the fluorescent light.
[C] The UV Light key indicates and controls ON/OFF power to the UV light (optional).
[D] The Outlet key indicates and controls ON/OFF power to the outlets.
[E] The Enter key is used to select item on display or accept and enter current
item, function or value.
[F] The Silence key allows a user to silence an audible alarm for 15 minutes.
After 15 minutes if the alarm condition continues, the alarm will repeat.
[G] The FlowGard OLED screen displays a variety of cabinet functions as well as
display cabinet performance.
[H] The Arrow Adjustment keys allow user interaction for various functions.
[I] The Red Alarm LED indicates any alarm condition.
11
Work Zone Dimensions (W x D x H) In. [ mm ]
Interchange Dimensions (W x D x H) In. [ mm ]
Net Weight
E: 230 VAC / 50 Hz
50 x 32 1/2 x 51 1/2
[ 1270 x 826 x 1308 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
425 lbs.
[ 193 kg. ]
[ 1880 x 826 x 1219 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
575 lbs.
[ 261 kg. ]
* Specify models with appropriate letter suffix for electrical specifications. “NU-PR797-400E” for 230 VAC / 50 Hz **Exterior width dimension will increase 3” minimum for base stand
Compounding Aseptic Isolators (CAI) for Non Hazardous Drugs
The PharmaGard PR creates a positive pressure clean air [ISO Class 5] controlled environment
specifically for aseptic compounding of non-hazardous drugs. The HEPA filtered work area maintains
a positive pressure relative to the interchange compartment, which
operates at a positive air pressure relative to the surrounding
room. These two levels of protection minimize the possibility of
contamination migrating into the work zone.
12
Specifications
50 fpm (0.25 m/s) Average Down Flow
Efficiency Features:
Motor Speed Controller
Internal Exhaust Damper
Superior Construction Features:
Monolithic 16/18 Gauge, Type 304 Stainless Steel Welded Pressure Tight Construction
Removable Control Center
Stainless Steel Spill Trough with Drain Valve
Vibration Reducing Work Surface Support System
External Non-Glare 100 lm/ft2 Fluorescent Lighting
Safety Features:
3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron Efficiency Rating
HEPEX Zero Leak Airflow System
UL Listed
Standard Features:
Large Oval Glove Ports
Flexible Two-Piece Nitrile Sleeve / Glove
Front Filter Removal
External Fluorescent Lighting
Removable Work Tray
One Duplex Outlet Back-wall
Optional Features and Accessories*:
Sharps and Waste System
Heated Work-surface
Adjustable Footrest
Custom Solutions
* Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
13
Work Zone Dimensions (W x D x H) In. [ mm ]
Interchange Dimensions (W x D x H) In. [ mm ] Net Weight
NU-NR800-400 4 ft.
50 x 32 1/2 x 51 3/4
[ 1270 x 826 x 1314 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
440 lbs.
[ 200 kg. ]
[ 1880 x 826 x 1314 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
590 lbs.
[ 268 kg. ]
[ 1270 x 826 x 1550 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
465 lbs.
[ 211 kg. ]
[ 1880 x 826 x 1550 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
615 lbs.
[ 279 kg. ]
* Specify models with appropriate letter suffix for electrical specifications. “NU-PR800-400E” for 230 VAC / 50 Hz **Exterior width dimension will increase 3” minimum for base stand
Compounding Aseptic Containment Isolators (CACI) for Hazardous Drugs
The PharmaGard NR and NTE create a negative pressure clean air [ISO Class 5] controlled environment
for the aseptic compounding of hazardous drugs. The HEPA filtered interchange compartment
maintains a negative pressure relative to the work area, which
operates at a negative air pressure relative to the surrounding room.
These levels of protection minimize the possibility of chemotherapy
agents or other hazardous materials migrating from the work area
into the surrounding room as well as minimizing the possibility of
contamination migrating into the work zone.
14
Specifications
Performance Specifications:
50 fpm (0.25 m/s) Average Down Flow
Efficiency Features:
Motor Speed Controller
Internal Exhaust Damper
Superior Construction Features:
Monolithic 16/18 Gauge, Type 304 Stainless Steel Welded Pressure Tight Construction
Removable Control Center
Stainless Steel Spill Trough with Drain Valve
Vibration Reducing Work Surface Support System
External Non-Glare 100 lm/ft2 Fluorescent Lighting
Safety Features:
3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron Efficiency Rating
12” (305 mm) Exhaust HEPA filter, 99.99 @ 0.3 Micron Efficiency Rating
HEPEX Zero Leak Airflow System
UL Listed
Standard Features:
Large Oval Glove Ports
3/8” Thick Scratch Resistant Polycarbonate Window
Flexible Two-Piece Nitrile Sleeve / Glove
Front Filter Removal
External Fluorescent Lighting
Removable Work Tray
One Duplex Outlet Back-wall
Optional Features and Accessories*:
Sharps and Waste System
Adjustable Footrest
Custom Solutions
* Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
15
Front Camera Mount
Storage Bin Sharps and Waste Back-wall LCD Screen Mount Ergotron® arm for monitor and keyboard/mouse
Cord Pass-thru (NSF) LED Lighting (Replaces Florescent Lighting)
Duplex and/or GFI Outlets
Popular Built-in Options & Accessories
Each laboratory is unique and every protocol can differ. Set your laboratory up for success by designing your own NuAire
Biological Safety Cabinet. It can be as simple as adding a service valve or as involved as customizing the height of the work
zone. NuAire can do it all. Invest in a product that lasts and is designed for your needs.
Design Your Own PharmaGard NU-797
16
Replacement Waste Bins TexWipe® Aseptic Cleaning Materials
Motorized Base Stand Bench Top MountTelescoping Leg Leveler or Castor Base Stand
Adjustable Foot Rest Stainless Steel Turntable Fixed Exhaust Canopy Transition w/ Alarm
Flex Duct Manual and Automatic Butterfly Valves
Airflow Alarms Laboratory Cart Silicone Connection Kit8” (204 mm) to 10” (254 mm) Round Transition
TexWipe® Isolator Cleaning Wand
17
NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.
Custom Solutions
Complete Your Pharmacy
NuAire custom solutions allow for sterile environments for any automation system: IV mixture, infusion compounding, syringe filling, and more.
18
Sales, Service, and Training
Delivering product to the customer that is cost effective, exceeds their requirements, delivers product
on-time, and increases productivity and profitability.
In every NuAire product you’ll find brilliant but practical design, keen attention to detail in every phase of the fabrication
and assembly process, thoroughly tested, outstanding value, and dependable service. These are the foundation for NuAire’s
international reputation, and practical reasons why NuAire is universally recognized as the finest. NuAire’s Quality Policy to
Satisfy Customers, Comply with Quality System Requirements and Continually Improve.
Sales and Service Like No Other NuAire employs a network
of knowledgable sales and service individuals some of which
have been selling and servicing NuAire Laboratory Products
since our inception in 1971.
Our Sales Representatives are located throughout the
globe providing you with a local individual who can assist
product selection, pricing, installation, training, and service
throughout the life of your product. Once you buy a
NuAire you’re a part of our family and we’ll work hard to
satisfy your needs.
assistance to service professionals in the laboratory
community. These NuAire certified companies are located
throughout the world allowing NuAire to provide service
and assistance to the farthest corners of the earth. Have
the option to select from multiple service vendors in your
area to find a company that fits your needs.
Contracts, GPO’s and many more! NuAire has a variety of
Contracts set up through Group Purchasing Organizations,
Government Associations, Health Systems, Universities
and many more.
SHARE A PICTURE AND TAG YOUR NUAIRE ISOLATOR USING #MYNUAIRE
Request a quote online © Copyright 2015. NuAire, Inc. All Rights Reserved.
20-1156-B-D-EN-5-1015-PharmaGard-Brochure
PROMOCIONES-JUNIO-rev2
PROMOCIONES-JUNIO-rev2_compressed
infographic-usp-797-and-usp-800-pec-requirements
nu-540-class-ii-type-a2-biosafety-cabinet-brochure
flyer-labgard-nu-560-class-ii-type-b2-biosafety-cabinet
brochure-pharmagard-compounding-isolators-nu-pr797
[email protected] [email protected]
GARANTIA
BIOSEGURIDAD
FOLLETO
+52 (33) 36 20 12 14 +52 (33) 36 20 12 15 +52 (55) 49 09 75 81 (cotizacion 24 / 7)
[email protected] [email protected]
https://www.abatec.com.mx/nuaire/
Disponibles con entrega inmediata NU-540-300 3 pies (0.9144m) NU-540-400 4 pies (1.2192m)
NU-540 Clase II Tipo A2
Gabinete de BioSeguridad
NU-560 Clase II Tipo B2
Disponibles con entrega inmediata NU-NRE800-600 6 pies (1.8m)
AISLADOR FARMACEUTICO
Horizontal Airflow Style: Console
CLASS II BIOSAFETY CABINET (BSC)
Type A2 70% Recirculated / 30 % Exhausted No Requirement to Externally Vent
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
Compounding Aseptic Isolator (CAI) Positive Pressure Recirculating
UNCLASSIFIED NO AIR CHANGES NEEDED
SEGREGATED COMPOUNDING AREA
ISO CLASS 7 CLEAN ROOM
+
+
+
+
+
+
+
+
+
+
≤24 Hrs if Refrigerated BUD ≤ 12 hrs
>24 Hrs if Refrigerated BUD > 12 hrs
CATEGORY 2 Beyond Use Date (BUD))
s BBBB BB
CONTAINMENT PRIMARY ENGINEERING CONTROL
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
ENTS
Negative Pressure Recirculating Canopy Connected External Vent
Compounding Aseptic Containment Isolator (CACI)
Negative Pressure Total Exhaust Hard Connection External Vent
Type B1 30% Recirculated /
70% Exhausted Hard Connection
ISO CLASS 7
NEG. PRESSURE 0.01” - 0.03” WC NEG. PRESSURE 0.01” - 0.03” WC
STERILE
≤24 Hrs if Refrigerated BUD ≤ 12 hrs BUD > 12 hrs
CATEGORY 2 Beyond Use Date (BUD)
>24 Hrs if Refrigerated
CONTAINMENT PRIMARY ENGINEERING CONTROL
EXTERNALLY VENTED OR REDUNDANT HEPA FILTER EXHAUST INTO ROOM
CLASS II BIOSAFETY CABINET (BSC) EXTERNALLY VENTED
RESTRICTED ACCESS BARRIER SYSTEM (RABS) OR ISOLATOR
EXTERNALL
OR
OR
Canopy Connected Exhaust
Exhaust into Room through Redundant HEPA Filters h t i t R th
Redundant HEPA Filters
Negative Pressure Recirculating Canopy Connected External Vent
Compounding Aseptic Containment Isolator (CACI)
Negative Pressure Total Exhaust Hard Connection External Vent763.553.1270 | NUAIRE.COM
Glove ports are used to provide physical separation between the surrounding area and the aseptic manipulations. If used to prepare Category 2 CSPs, the area surrounding the RABS must meet ISO Class 7 or better air quality.
All transport ports on the RABS must be closed during compounding. When a RABS is used, the recovery time after opening to achieve ISO Class 5 air quality must be documented, and internal procedures must be developed to ensure that adequate recovery time is allowed after opening and closing the RABS, both before and during compounding operations.
RESTRICTED ACCESS BARRIER SYSTEM (RABS) Provides isolation from the surrounding area and maintains ISO Class 5 air quality during typical operating conditions.
The following standards must be met to qualify as an isolator:
• High-integrity transfer ports are used to move supplies, Ingredients, components, and devices into and out of the isolator.
• The isolator is decontaminated using a generator that distributes a sporicidal chemical agent throughout the isolator chamber.
• The isolator maintains constant overpressure of at least 0.05-inch water column.
• The manufacturer has provided documentation that the isolator will continuously meet ISO Class 5 conditions, including during material transfer.
• A CAI or CACI is not an isolator.
ISOLATOR
FLOW CHART FOR USP 797 AND USP 800 PEC REQUIREMENTS
ACPH - Air Changes per Hour BUD - Beyond Use Date BSC - Biosafety Cabinet CACI - Compounding Aseptic Containment Isolator CAI - Compounding Aseptic Isolator C-PEC - Containment Primary Engineering Control C-SCA - Containment Segregated Compounding Area C-SEC - Containment Secondary Engineering Control CSP - Compounded Sterile Preparation CVE - Containment Ventilated Enclosure LAFW - Laminar Airflow Workstation PEC - Primary Engineering Control RABS - Restricted Access Barrier System SCA - Segregated Compounding Area SEC - Secondary Engineering Control
Glossary
Sources
USP General Chapter <800> Hazardous Drugs– Handling in Healthcare Settings. (2017). The United States Pharmacopeial Convention.
General Chapter <797> Pharmaceutical Compounding – Sterile Compounding. (n.d.). The United States Pharmacopeial Convention.
20-1389-I-D-EN-4-1018
A CAI is designed for compounding non-HD CSPs. It is designed to maintain an ISO Class 5 environment throughout the compounding and material transfer processes. Air exchange into the CAI from the surrounding environment must not occur unless the air has first passed through a HEPA filter.
COMPOUNDING ASEPTIC ISOLATOR (CAI)
TYPES OF RABS
A CACI is designed to provide worker protection from exposure to undesirable levels of airborne drug throughout the compounding and material transfer processes, and to maintain an ISO Class 5 environ- ment for compounding sterile HD preparations. Air exchange with the surrounding environment must not occur unless it is first passed through a HEPA filter capable of containing airborne concentrations of the physical size and state of the drug being compounded.
COMPOUNDING ASEPTIC CONTAINMENT ISOLATOR (CACI)
DESIGNED BY YOU. DESIGNED FOR YOUR APPLICATION.
NU-540 CLASS II TYPE A2 BIOLOGICAL SAFETY CABINET
NuAire, Inc. | 2100 Fernbrook Lane | Plymouth, MN 55447 | U.S.A. | nuaire.com
For more information please visit www.nuaire.com or call 1-763-553-1270
There is a Perfect Fit for You
3 FOOT 4 FOOT 6 FOOT5 FOOT
You deserve a quality and robust Biological Safety Cabinet every time you sit down for work. NuAire Biological Safety Cabinets
are designed to last. Every NuAire Biological Safety Cabinet goes through a series of checks before it reaches your laboratory.
As your product moves through the assembly plant, each work station double checks the work of the previous station, filters
are tripled check, and biological tests are constantly being performed under dynamic conditions to ensure maximum safety.
Each cabinet is built to order for your application. It is as simple as including an additional service valve or as complex as
developing the interior to fit a specific piece of machinery.
Our local sales representatives are the best in the industry. They assist with product selection, review built-in options and
accessories, discuss pricing, offer installation guidance, and provide support over the life of your NuAire product.
Designed By You. Designed for your Application.
NU-540
is a Class II, Type A2 Biological Safety Cabinet
offering Personnel, Product, and Environmental
Protection through the use of quality design,
an ultra high efficiency motor, and longer
lasting filters all at an affordable price.
Join the NuAire family of over 100,000
Biological Safety Cabinets in use throughout
the world and learn why NuAire offers the
longest lasting, lower cost, and safest
Biological Safety Cabinet in the world.
NU-540
6” (152 mm)
- Recessed air foil
- Recessed work zone
- More knee room
- Ability to sit or stand at a range of heights
- 21” (533 mm) frame-less edge window sash improves vision/sight lines into work zone
- Staggered service valves
- Accessories (elbow rests, armrest foam pads, ergo chair, adjustable base stand, sst turntable)
Ergonomic Design
NuAire designs equipment that accommodates advancement for: improved safety conditions; improved productivity;
improved quality and reliability; and reduction of arm, shoulder, and neck strain contributing to common work place injuries.
NU-540
Wrists Straight90
23”-28”Adjustable Seat Height
[ Larger Work Area ]
[ Expanded Vision Zone ]
[B]
[A]
Monolithic Design. At core of any biosafety cabinet is its basic structure. NuAire has over 100,000 biological
safety cabinets in the field; some of which have been running strong since the 1970’s.
The NuAire design is a single piece of type 304 stainless steel. A stainless steel wrap [A] makes up the walls
of the cabinet. Stainless steel sheets [B] are welded in place to make up the top and bottom of the cabinet. A
smaller wrap [C] featuring coved interior corners is welded in place to make up the back wall of the cabinet.
This improves the cabinet integrity by creating a double sidewall. New work tray supports [D] help minimize
the vibration transfer from the shell of the cabinet to the work zone.
The end result is a monolithic shell of 100% stainless steel [E] without the use of silicone like many multi-piece
cabinets. This provides you with a solid foundation for longer product life eliminating potential leaks.
[D][C]
Save More Money Over a Longer Period of Time
Ultra High Efficiency Motor. An ultra-high efficiency ECM motor combined with the properly sized
fan blade lowers energy usage while extending the life of filters. LabGard® offers the lowest total
cost of ownership compared to other models.
* estimate based on Filter Load capacity ** estimate based on historical information. Disclaimer: This example is for illustrative purposes only and should not be deemed a representation of future performance or a guarantee of any kind. Information is based on internal performance data obtained through NuAire® testing and information provided by motor, blower, HEPA filter manufacturers, and independent service technicians.
Total cost of ownership breakdown. Motor Comparison NuAire DC ECM NuAire AC PSC BSC with AC 3-Phase BSC with DC
8 hrs per day / 5 days per week = 2,000 hrs per year
KWH per year 598 1128 828 326
$0.09/kwh $54 $102 $75 $29
24 hrs per day / 7 days per week = 8,736 hrs per year
KWH per year 2612 4927 3617 1424
$0.09/kwh $235 $443 $326 $128
15 Year Life Cycle Costs
Avg. Filter Changes* 1 Set 2 Sets 1 Set 3 Sets
Estimated Cost of HEPA Filters $715 $1,430 $715 $2.145
Total Cost of Decon/Certification $450 $900 $450 $1,350
Motors to Replace** 1 Motor 1 Motor 1 Motor 2 Motors
Cost of Motors/ Power Supplies/ Fan Control
$650 $420 $725 $2,544
$810 $1,530 $1,125 $435
NU-540
by operating environment
Software/Hardware Watchdog - automatically reset upon failure to last known status or to
blower “ON” to assure containment.
Software updates via USB
maintaining work zone sterility.
AeroMax Electronic Control System (ECS) monitors and displays airflow system performance via
PresurFlow™ - A specialized digital pressure transducer.
Visual Alarm Visual status alarm:
Green Normal Operation Yellow Near Alarm Status
Red Status Alarm
Outlet(s) On/Off
Up Value Down Value
Alarms. An audible alarm will sound for 30 continuous seconds then ring back for one second every five seconds until silenced or the alarm
condition is cleared. If Silence is pressed, the Silenced alarm condition will be blocked from repeating for a period of 15 minutes.
NU-540
8
NuAire’s commitment to safety doesn’t stop at meeting industry standards. NuAire continually performs dynamic tests to
push the limits of our product’s performance to ensure you and your laboratory personnel will remain safe.
Automatic Airflow Compensation - the Ultra High Efficiency motor will automatically increase or decrease speed to maintain
proper airflow settings based on readings from AeroMax ECS.
Your Safety is Our Number 1 Priority
True laminar (unidirectional) downward moving air flushes the
work surface at 60 fpm (0.30 m/s) minimizing cross contamination.
A dynamic air barrier at the front of the cabinet separates the laboratory
from the work zone environment at an air speed of 105 fpm (0.53 m/s).
The HEPEX Zero Leak Airflow system evenly disperses air over the supply and exhaust
HEPA filters, minimizes vibration transfer, and eliminates potential leaks by surrounding positive
pressure chambers with negative pressure.
Air Split
9
We at NuAire® have designed each LabGard® Biosafety Cabinet to be service friendly. 100% of service functions can be
performed at the front or top of the cabinet.
Drop Down Control Panel
tray for service technicians.
Front Filter Access
of the cabinet with the removal of a safety panel.
Decon101 System
systems that use Formaldehyde, Chlorine Dioxide
or Vapor Phase Hydrogen Peroxide
Make it Easier on your Service Personnel
NU-540
Sustainability
At NuAire we continually strive to improve our responsibilities to the economy, environment, social communications, and
our customer satisfaction. Our commitment extends to purchasing or using products that reduce energy consumption,
reduce environmental impact, minimize pollution and make use of recycled content that will not deplete natural resources.
We continually use more recycled materials in our cabinets through both design and supplier parts and process improve-
ments. The following chart represents our current level of sustainability for Biological Safety Cabinets.
General Cabinet % Content by Weight % of Recycled Material % Recyclable Component Description used in Manufacturing
Stainless Steel 75% 80% 100%
Mild Steel 10% 10% 100%
Copper 2% 0% 100%
Aluminum 2% 50% 100%
Glass 3% 0% 100%
Electronics 1% 0% 25%
Misc. Plastic Parts 1% 0% 0%
Packing Materials 5% 60% 95%
100% BSC 65% 97%
Net Weight
[ 873 x 654 x 724 ]
41 5/8 x 31 7/16 x 61 7/8
[ 1057 x 799 x 1572 ]
400 lbs
[ 181 kg ]
[ 1178 x 654 x 724 ]
53 5/8 x 31 7/16 x 61 7/8
[ 1362 x 799 x 1572 ]
465 lbs
[ 211 kg ]
[ 1483 x 654 x 724 ]
65 5/8 x 31 7/16 x 61 7/8
[ 1669 x 799 x 1572 ]
550 lbs
[ 249 kg ]
[ 1788 x 654 x 724 ]
77 5/8 x 31 7/16 x 61 7/8
[ 1972 x 799 x 1572 ]
620 lbs
[ 281 kg ]
Specifications
Specifications
The LabGard ES is a Class II Type A2 Biological Safety Cabinet that can be either exhausted back into the room
or connected to a facility HVAC system. The cabinet’s airflow is 30% exhausted / 70% recirculated to minimize cross-
contamination of low to moderate risk biologicals in the absence of volatile toxic chemicals.
WARRANTY - Best products backed by the best warranty.
5 Parts (Filters Included) & Labor (US & CA)
6 Years Parts (Filters Included) (Intl)
10” (254 mm)
8” (203 mm)
NU-540
60 fpm (0.30 m/s) Down Flow
Filter Load Capacity 250% plus
Filter Life +- 10 Years
Attenumont Vibration Control System
Permanent Plenum with Quick Release Supply Filter
3” (76 mm) Metal Frame Supply HEPA Filter 99.99% @ 0.3 microns
6” (152 mm) Metal Frame Exhaust HEPA Filter 99.99% @ 0.3 microns
Metal Diffuser Over Supply Filter
10” (254 mm) Window Sash Access Opening
Frame-less Sliding Tempered Glass View Window
External Fluorescent Lighting
Front Filter Removal
PVC Plastic Armrest
Removable Work Tray
Removable Airflow Grill
Two (2) Duplex Outlets Back Wall
One (1) Service Valve Right Side Wall
One (1) Service Coupling Right Side Wall
Two (2) Service Couplings Left Side Wall
12 ft. (2.5m) Power Cord
Optional Features and Accessories*:
Metal Frame Supply ULPA Filter 99.999% @ 0.12 microns
Metal Frame Exhaust ULPA Filter 99.999% @ 0.12 microns
Canopy Exhaust Transitions
IV Bar with Six (6) Hooks
Duplex Outlets
Additional Service Valves/Couplings Up to Three (3) Each Side Wall
Prop Up Work Tray
Telescoping Base Support Stand
Motorized Base Support Stand
Base Support Stand Shelf
Adjustable Footrest
Elbow Rests
Armrest Pads
Custom Solutions
Class II, Type A2 Air In-flow 70% Recirculated vs. 30% Exhausted
HEPA Filtered Air
Contaminated Worksurface Air
Contaminated Room Air
Air Split*Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
NU-540
Ultraviolet (UV) Light
Microscope Window Ergotron® arm for monitor and keyboard/mouse
Cord Pass-thru (NSF) LED Lighting (Replaces Florescent Lighting)
Duplex and/or GFI Outlets
Design Your Very Own
Each laboratory is unique and every protocol can differ. Set your laboratory up for success by designing your own NuAire Biological
Safety Cabinet. It can be as simple as adding a service valve or as involved as customizing the height of the work zone. NuAire
can do it all. Invest in a product that lasts and is designed for your needs.
Popular Built-in Options & Accessories
Airflow Alarms Laboratory Cart Silicone Connection Kit
Motorized Base Stand Base Stand ShelfTelescoping Leg Leveler or Castor Base Stand
Adjustable Foot Rest Stainless Steel Turntable
Options and Accessories
Flex Duct Manual and Automatic Butterfly Valves
8” (204 mm) to 10” (254 mm) Round Transition
Variable Flow Control (VFC) Exhaust Transition w/ Alarm
NU-540
Complete your Laboratory
NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.
Mini-Centrifuges
Compounding Isolators Animal Laboratory Products Polypropylene Fume Hoods
and Casework
17
Delivering product to the customer that is cost effective, exceeds their requirements, delivers product on-time, and increases
productivity and profitability.
In every NuAire product you’ll find brilliant but practical design, keen attention to detail in every phase of the fabrication and
assembly process, thoroughly tested, outstanding value, and dependable service. These are the foundation for NuAire’s inter-
national reputation, and practical reasons why NuAire is universally recognized as the finest. NuAire’s Quality Policy to Satisfy
Customers, Comply with Quality System Requirements and Continually Improve.
Sales and Service Like No Other NuAire employs a network of
knowledgable sales and service individuals some of which have been
selling and servicing NuAire Laboratory Products since our inception
in 1971.
Working safely video series. Learn how to work safely in your NuAire
Biological Safety Cabinet with this 7 Chapter online video series.
Our Sales Representatives are located throughout the globe
providing you with a local individual who can assist product
selection, pricing, installation, training, and service throughout the
life of your product. Once you buy a NuAire you’re a part of our
family and we’ll work hard to satisfy your needs.
NuAire offers service-training classes and individualize assistance
to service professionals in the laboratory community. These NuAire
certified companies are located throughout the world allowing
NuAire to provide service and assistance to the farthest corners of
the earth. Have the option to select from multiple service vendors in
your area to find a company that fits your needs.
Contracts, GPO’s and many more! NuAire has a variety of Contracts
set up through Group Purchasing Organizations, Government
Associations, Health Systems, Universities and many more.
ISO 9001:2008 Certificate ISO 13485 Certificate
NU-540
20-1315-B-D-EN-3-0516 Request a quote online
For more information please visit www.nuaire.com or call 1-763-553-1270
SHARE A PICTURE AND TAG YOUR NUAIRE BIOSAFETY CABINET USING #MYNUAIRE
Your Local NuAire Partner
NuAire® | 2100 Fernbrook Lane | Plymouth, MN 55447 | USA | 763-553-1270 | www.nuaire.com
© Copyright 2018 NuAire, Inc. All Rights Reserved
20-1459-F-D-EN-4-1218
NU-560 CLASS II TYPE B2 BIOSAFETY CABINET
The LabGard® ES (Energy Saver) TE (Total Exhaust) NU-560 Biosafety Cabinet (BSC) is available as a bench or table top cabinet designed to provide optimum control over product quality in the lab, while also reducing the risk of exposing the product or lab personnel to any airborne biological or particulate chemical agents. This cabinet -- which meets all requirements of a Class II, Type B2 cabinet -- is equipped with an energy-saving motor to maximize energy efficiency and filter loading capacity. As prescribed by the Center for Disease Control in Atlanta, Georgia, the cabinet is intended for use in low to moderate risk-hazard research and drug preparation or product operations.
Blower UV Light Fluorescent Light Outlet Timers Menu
Night setback mode is initiated by the window closure, will reduce motor / blower operational airflow to conserve energy while maintaining work zone sterility.
COMPONENTS
intelliflow™ airflow sensor technology incorporates the same thermal anemometer technology used by service technicians (certifiers) to annually verify your biological safety cabinet’s airflow performance.
Performance Features: • 100% exhausted • Dynamic air barrier of 105 linear fpm (0.54 m/s)
inflow separating laboratory from work zone environment
• True Laminar Unidirectional Down-flow air of 60 fpm (0.30 m/s) for minimal cross contamination
• 300% Filter Load Capacity for Supply HEPA only (±10 Year Average depending on laboratory environment)
• ISO Class 5 Clean Air
The NuAire TouchLink Touchscreen LCD Control Center brings Biosafety Cabinet performance to your fingertips. The TouchLink control center allows supervisors to control the blower by password, provides real-time airflow measurements
and alarms, and integrates quickly with current facility security systems. TouchLink also simplifies maintenance by providing detailed diagnostic information and step-by-step decontamination procedures. TouchLink can even wake up when you do—by running the blower and lights on a customizable schedule!
Real time Airflow
NuAire® | 2100 Fernbrook Lane | Plymouth, MN 55447 | USA | 763-553-1270 | www.nuaire.com
© Copyright 2018 NuAire, Inc. All Rights Reserved
20-1459-F-D-EN-4-1218
NU-560 CLASS II TYPE B2 BIOSAFETY CABINET
*Specify model with appropriate letter suffix for electrical specifications. “NU-560-400E” for 230 VAC / 50 - 60 Hz
Model Width Size (nominal) Electrical* (all sizes) Interior Dimensions
(W x D x H) in. [mm] Exterior Dimensions (W x D x H) in. [mm] Net Weight Exhaust
Requirement
E: 230 VAC / 50 Hz-60 Hz
46 3/8 x 26 x 25 3/16 [1178 x 660 x 640]
53 5/8 x 31 7/16 x 62 [1362 x 798 x 1575]
490 lbs [222 kg] 815 CFM @ 1.7 w.g.
NU-560-600 6 ft [1.8 m]
70 3/8 x 26 x 25 3/16 [1788 x 660 x 640]
77 5/8 x 31 7/16 x 62 [1972 x 798 x 1575]
680 lbs [308 kg] 1275 CFM @ 1.8 w.g.
Specifications
request online or scan the code.
Popular Accessories/Built-in Options
Prop Up Work Surface Ultraviolet (UV) LightArm Rest Pads Elbow RestMotorized Base StandTelescoping Leg Leveler or Castor Base Stand
NuAire is a sponsor of the IFBA
Standard Features
Ultra-high Efficiency Motor
Front Filter Removal
Metal Diffuser Over Supply Filter
3-inch (76mm) Supply HEPA Filter 99.99 @
0.3 Micron Efficiency Rating
12-inch (305 mm) Exhaust HEPA Filter 99.99 @ 0.3 Micron Efficiency Rating
Attenumont Vibration Control
Exterior LED Lighting
Frame-less Sliding Tempered Glass View Screen
Heavy Duty, Ergonomic Plastic Armrest
10 degree slope front
Power Cord
**Telescoping Base Stand Only
Bag In/Bay Out of Exhaust HEPA Filter with Single Point External Release
Ultraviolet Light
Additional Service Valves
IV Bar with 3 Locations, 6 Stainless Steel Hooks
Gas Tight Butterfly Valves (Manual or Automatic)
Sink with Hot/Cold or DI Water Faucets
Storage Pull-Out Trays
Decorative Side Panels
• Auto Filter Loading Compensation
Superior Construction Features: • Monolithic 16/18 Gauge, Type 304 Stainless Steel
Welded
• Removable Control Center
• Stainless Steel Spill Trough with Drain Valve
• Vibration Reducing Work Surface Support System
• External Non-Glare 110 lm/ft2 LED Lighting
Safety Features: • 3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron
Efficiency Rating
Microns Efficiency Rating
• Airflow / Window Alarms with Ring Back Function
• Security Password Protection
• NSF/ANSI 49, UL Listed
NuAire, Inc. | 2100 Fernbrook Lane | Plymouth, MN 55447 | U.S.A. | nuaire.com
For more information please visit www.nuaire.com or call 1.763.553.1270
1
2
NuAire PharmaGard Compounding Aseptic & Containment Isolators are engineered to maximize work productivity by providing a comfortable and ergonomically correct environment.
PharmaGard Compounding Aseptic (CAI) and Containment
(CACI) Isolators provide a sterile work environment for
the compounding of hazardous and non-hazardous drugs.
PharmaGard creates true HEPA filtered laminar airflow at
20 air changes per minute within both the work zone and
interchange areas to assure ISO Class 5 conditions. Utilizing
laminar flow assures a continuous stream of HEPA filtered air
across the work zone and interchange areas assuring sterility
and minimizes cross contamination. Once the air is through
the work area, the airflow is split from front to rear. The
airflow then proceeds under the work tray, up the rear divider
panel where it is recirculated or exhausted.
The PharmaGard PR is a Compounding Aseptic Isolator that meets the USP 797 Standard for aseptic compounding of non-hazardous drugs.
The PharmaGard NTE is a Compounding Aseptic Containment Isolator that meets the USP 800 Standard for handling hazardous drugs.
3
PharmaGard Compounding Aseptic and Containment Isolators offer the best possible user ergonomics.
Ergonomic features on the PharmaGard include:
Counter Balance Inner Transfer Window
The transfer window counter balance [B] is isolated from
sterile product inside the inter-chamber wall. The window
moves easily up or down with one finger. A security lock on
NR and NTE units ensures the inner transfer door remains
locked if the outer door is open.
Sliding Work Tray
Located in the transfer compartment, the sliding work tray [A]
provides a seamless transition when entering compounding
materials into the work zone. The stainless steel work tray
is mounted on ball bearing brackets to smoothly enter
compounding materials into the sterile work area.
[B]
[A]
4
Expanded Vision Zone and Work Zone
PharmaGard isolators offer greater visibility due to cool white lighting and open sight lines. The largest effective work zone [C]
helps reduce arm / neck / shoulder strain. Large oval glove ports [D] extend the reach of the user, and three IV bar locations
[E] provide proper compounding height/distance.
Ability to sit or stand at a range of heights
The isolator design maximizes knee/thigh clearance to
improve posture and the adjustable base stand allows for
optimization of leg and upper body support.
[D]
[E]
5
6
[A]
Sharps and Waste Disposal
The PharmaGard allows a user to dispose of waste and sharps directly from the sterile work zone. Two waste containers [A] are accessible through covered negative pressure drop tubes to maintain sterility inside the work area and containment on the isolator exterior.
Once a container has been filled and is ready for replacement, PharmaGard
allows the end user to individually change out each container when needed.
After the waste or sharps container lid has been sealed, follow these steps:
Step 1. Release locking mechanism by
pulling handle.
Remove container block.
and replace.
Documentation and Surveillance Training in the Pharmacy
US Pharmacopeia (USP) calls for the documentation of standard operating procedures (SOPs) and the development of a medical surveillance programs. NuAire has developed easy add-on accessories and built-in options to help with the documentation process.
Monitor and Keyboard/Mouse Arm
technicians to easily access and follow compounding SOPs.
Workflow documentation can be entered throughout the
compounding process.
Video Cameras
One or more cameras can be added to a PharmaGard back
wall or mounted to the front of the control panel to monitor
the healthcare worker, document compounding processes or
spill control procedures, etc.
work area by a glass panel can be added to
the back wall of a PharmaGard.
Video Surveillance Cameras
allows for the mounting of many different
types of cameras outside the cabinet.
9
Electronic Control System (ECS)
Each PharmaGard Electronic Control System (ECS) is designed for high user adoption. Easy to read on/off switches make
each PharmaGard simple to operate. Visual indication of system operations is shown through mini-helic gauges that monitor
pressures within the interchange and main chamber.
Compounding Aseptic Isolators (CAI)
The Pressure Monitor displays the positive static pressure within the main chamber. The pressure monitor is calibrated in
“inches of water gauge” pressure. The pressure monitor will read the same as the main chamber minihelic gauge and in
addition, allow a low/high alarm limit point to be set. The default alarm limits is set to 0.10” w.g. low and 0.50” w.g. high. See
optional equipment section for greater detail.
[A] The Blower key indicates and controls ON/OFF power to the blower.
[B] The Light key indicates and controls ON/OFF power to the fluorescent light.
[C] The UV Light key indicates and controls ON/OFF power to the UV light (optional).
[D] The Outlet key indicates and controls ON/OFF power to the outlets.
[E] The Enter key is used to select item on display or accept and enter current
item, function or value.
[F] The Silence key allows a user to silence an audible alarm for 15 minutes.
After 15 minutes if the alarm condition continues, the alarm will repeat.
[G] The FlowGard OLED screen displays a variety of cabinet functions as well as
display cabinet performance.
[H] The Arrow Adjustment keys allow user interaction for various functions.
[I] The Red Alarm LED indicates any alarm condition.
[I]
Compounding Aseptic Containment Isolators
(CACI) pressure. System operational health is displayed
visually through system LEDs. Each color represents specific
condition outlined below:
Green = Acceptable Pressure
Red = Alarm Condition
In the event of an Alarm Status a audible alarm will sound
notifying the end user the system no longer offers protection.
The PharmaGard Digital Monitor comes standard on models
NU-NR800 and NU-NTE800 and is an optional upgrade on
model NU-PR797.
The PharmaGard Pressure Monitor displays the negative static pressure with- in the main chamber. The pressure monitor is calibrated in “inches of water gauge” pressure. The pressure monitor will read the same as the main chamber minihelic gauge and in addition, allow a low/high alarm limit point to be set. The default alarm limits is set to - 0.05” w.g. high and - .50” w.g. low.
[I]
[C][B][A]
[A] The Blower key indicates and controls ON/OFF power to the blower.
[B] The Light key indicates and controls ON/OFF power to the fluorescent light.
[C] The UV Light key indicates and controls ON/OFF power to the UV light (optional).
[D] The Outlet key indicates and controls ON/OFF power to the outlets.
[E] The Enter key is used to select item on display or accept and enter current
item, function or value.
[F] The Silence key allows a user to silence an audible alarm for 15 minutes.
After 15 minutes if the alarm condition continues, the alarm will repeat.
[G] The FlowGard OLED screen displays a variety of cabinet functions as well as
display cabinet performance.
[H] The Arrow Adjustment keys allow user interaction for various functions.
[I] The Red Alarm LED indicates any alarm condition.
11
Work Zone Dimensions (W x D x H) In. [ mm ]
Interchange Dimensions (W x D x H) In. [ mm ]
Net Weight
E: 230 VAC / 50 Hz
50 x 32 1/2 x 51 1/2
[ 1270 x 826 x 1308 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
425 lbs.
[ 193 kg. ]
[ 1880 x 826 x 1219 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
575 lbs.
[ 261 kg. ]
* Specify models with appropriate letter suffix for electrical specifications. “NU-PR797-400E” for 230 VAC / 50 Hz **Exterior width dimension will increase 3” minimum for base stand
Compounding Aseptic Isolators (CAI) for Non Hazardous Drugs
The PharmaGard PR creates a positive pressure clean air [ISO Class 5] controlled environment
specifically for aseptic compounding of non-hazardous drugs. The HEPA filtered work area maintains
a positive pressure relative to the interchange compartment, which
operates at a positive air pressure relative to the surrounding
room. These two levels of protection minimize the possibility of
contamination migrating into the work zone.
12
Specifications
50 fpm (0.25 m/s) Average Down Flow
Efficiency Features:
Motor Speed Controller
Internal Exhaust Damper
Superior Construction Features:
Monolithic 16/18 Gauge, Type 304 Stainless Steel Welded Pressure Tight Construction
Removable Control Center
Stainless Steel Spill Trough with Drain Valve
Vibration Reducing Work Surface Support System
External Non-Glare 100 lm/ft2 Fluorescent Lighting
Safety Features:
3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron Efficiency Rating
HEPEX Zero Leak Airflow System
UL Listed
Standard Features:
Large Oval Glove Ports
Flexible Two-Piece Nitrile Sleeve / Glove
Front Filter Removal
External Fluorescent Lighting
Removable Work Tray
One Duplex Outlet Back-wall
Optional Features and Accessories*:
Sharps and Waste System
Heated Work-surface
Adjustable Footrest
Custom Solutions
* Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
13
Work Zone Dimensions (W x D x H) In. [ mm ]
Interchange Dimensions (W x D x H) In. [ mm ] Net Weight
NU-NR800-400 4 ft.
50 x 32 1/2 x 51 3/4
[ 1270 x 826 x 1314 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
440 lbs.
[ 200 kg. ]
[ 1880 x 826 x 1314 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
590 lbs.
[ 268 kg. ]
[ 1270 x 826 x 1550 ]
35 1/4 x 23 1/4 x 27 3/8
[ 895 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
465 lbs.
[ 211 kg. ]
[ 1880 x 826 x 1550 ]
59 1/4 x 23 1/4 x 27 3/8
[ 1505 x 591 x 695 ]
14 1/8 x 24 x 27 3/8
[ 359 x 610 x 695 ]
615 lbs.
[ 279 kg. ]
* Specify models with appropriate letter suffix for electrical specifications. “NU-PR800-400E” for 230 VAC / 50 Hz **Exterior width dimension will increase 3” minimum for base stand
Compounding Aseptic Containment Isolators (CACI) for Hazardous Drugs
The PharmaGard NR and NTE create a negative pressure clean air [ISO Class 5] controlled environment
for the aseptic compounding of hazardous drugs. The HEPA filtered interchange compartment
maintains a negative pressure relative to the work area, which
operates at a negative air pressure relative to the surrounding room.
These levels of protection minimize the possibility of chemotherapy
agents or other hazardous materials migrating from the work area
into the surrounding room as well as minimizing the possibility of
contamination migrating into the work zone.
14
Specifications
Performance Specifications:
50 fpm (0.25 m/s) Average Down Flow
Efficiency Features:
Motor Speed Controller
Internal Exhaust Damper
Superior Construction Features:
Monolithic 16/18 Gauge, Type 304 Stainless Steel Welded Pressure Tight Construction
Removable Control Center
Stainless Steel Spill Trough with Drain Valve
Vibration Reducing Work Surface Support System
External Non-Glare 100 lm/ft2 Fluorescent Lighting
Safety Features:
3” (76 mm) Supply HEPA Filter, 99.99 @ 0.3 Micron Efficiency Rating
12” (305 mm) Exhaust HEPA filter, 99.99 @ 0.3 Micron Efficiency Rating
HEPEX Zero Leak Airflow System
UL Listed
Standard Features:
Large Oval Glove Ports
3/8” Thick Scratch Resistant Polycarbonate Window
Flexible Two-Piece Nitrile Sleeve / Glove
Front Filter Removal
External Fluorescent Lighting
Removable Work Tray
One Duplex Outlet Back-wall
Optional Features and Accessories*:
Sharps and Waste System
Adjustable Footrest
Custom Solutions
* Note: some optional features are not approved by 3rd party listings. Please contact NuAire information.
15
Front Camera Mount
Storage Bin Sharps and Waste Back-wall LCD Screen Mount Ergotron® arm for monitor and keyboard/mouse
Cord Pass-thru (NSF) LED Lighting (Replaces Florescent Lighting)
Duplex and/or GFI Outlets
Popular Built-in Options & Accessories
Each laboratory is unique and every protocol can differ. Set your laboratory up for success by designing your own NuAire
Biological Safety Cabinet. It can be as simple as adding a service valve or as involved as customizing the height of the work
zone. NuAire can do it all. Invest in a product that lasts and is designed for your needs.
Design Your Own PharmaGard NU-797
16
Replacement Waste Bins TexWipe® Aseptic Cleaning Materials
Motorized Base Stand Bench Top MountTelescoping Leg Leveler or Castor Base Stand
Adjustable Foot Rest Stainless Steel Turntable Fixed Exhaust Canopy Transition w/ Alarm
Flex Duct Manual and Automatic Butterfly Valves
Airflow Alarms Laboratory Cart Silicone Connection Kit8” (204 mm) to 10” (254 mm) Round Transition
TexWipe® Isolator Cleaning Wand
17
NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.
Custom Solutions
Complete Your Pharmacy
NuAire custom solutions allow for sterile environments for any automation system: IV mixture, infusion compounding, syringe filling, and more.
18
Sales, Service, and Training
Delivering product to the customer that is cost effective, exceeds their requirements, delivers product
on-time, and increases productivity and profitability.
In every NuAire product you’ll find brilliant but practical design, keen attention to detail in every phase of the fabrication
and assembly process, thoroughly tested, outstanding value, and dependable service. These are the foundation for NuAire’s
international reputation, and practical reasons why NuAire is universally recognized as the finest. NuAire’s Quality Policy to
Satisfy Customers, Comply with Quality System Requirements and Continually Improve.
Sales and Service Like No Other NuAire employs a network
of knowledgable sales and service individuals some of which
have been selling and servicing NuAire Laboratory Products
since our inception in 1971.
Our Sales Representatives are located throughout the
globe providing you with a local individual who can assist
product selection, pricing, installation, training, and service
throughout the life of your product. Once you buy a
NuAire you’re a part of our family and we’ll work hard to
satisfy your needs.
assistance to service professionals in the laboratory
community. These NuAire certified companies are located
throughout the world allowing NuAire to provide service
and assistance to the farthest corners of the earth. Have
the option to select from multiple service vendors in your
area to find a company that fits your needs.
Contracts, GPO’s and many more! NuAire has a variety of
Contracts set up through Group Purchasing Organizations,
Government Associations, Health Systems, Universities
and many more.
SHARE A PICTURE AND TAG YOUR NUAIRE ISOLATOR USING #MYNUAIRE
Request a quote online © Copyright 2015. NuAire, Inc. All Rights Reserved.
20-1156-B-D-EN-5-1015-PharmaGard-Brochure
PROMOCIONES-JUNIO-rev2
PROMOCIONES-JUNIO-rev2_compressed
infographic-usp-797-and-usp-800-pec-requirements
nu-540-class-ii-type-a2-biosafety-cabinet-brochure
flyer-labgard-nu-560-class-ii-type-b2-biosafety-cabinet
brochure-pharmagard-compounding-isolators-nu-pr797