VIGA SR VIGA DE HORMIGN ARMADO SEGN ACI - 2002 "DELFIN"
1 286846004.xlsx Msc. Ing. Franz Milton Delgado Lazarte
RESISTENCIA NOMINAL DE SECCIN RECTANGULAR
Caracterscas Geomtricas Caractersticas de los Materiales Coeficientes por NormaB = 30 (cm) F'c = 200 (kg/cm2) CM =H = 65 (cm) Fy = 4200 (kg/cm2) CV =
rec = 5 (cm) 1 = 0.85d = 60 (cm) Ec = 222222 (kg/cm2)Ac = 1950 (cm2) Es = 2000000 (kg/cm2)b = 1 (plg) n = 9#b = 3 f = 0.90
Aunit = 5.07 (cm2)Astot = 15.20 (cm2)
Resolucin1. Cuantas.
= 0.0084 = 0.84 (%)
cb = 35.29 (cm) b = 0.0202 b =
ab = 30.00 (cm)
2. Altura del bloque de compresin del Concreto.
a = 12.52 (cm) 20.9 % del Peralte Efectivo
3. Momento Nominal Resistente de la Seccin.
Mn = 3431080.87 (kg.cm) Mn = 34310.81 (kg.m)
4. Momento ltimo Resistente de la Seccin.
Mu = 30879.73 (kg.m)
-
VIGA SR VIGA DE HORMIGN ARMADO SEGN ACI - 2002 "DELFIN"
2 286846004.xlsx Msc. Ing. Franz Milton Delgado Lazarte
-
VIGA SR VIGA DE HORMIGN ARMADO SEGN ACI - 2002 "DELFIN"
3 286846004.xlsx Msc. Ing. Franz Milton Delgado Lazarte
Coeficientes por Norma1.21.4
2.02 (%)
-
VIGA SR VIGA DE HORMIGN ARMADO SEGN ACI - 2002 "DELFIN"
4 286846004.xlsx Msc. Ing. Franz Milton Delgado Lazarte
VIGA SR