Dvm hydro sales Presentation

of 23 /23
DVM HYDRO

Embed Size (px)

Transcript of Dvm hydro sales Presentation

  • DVM HYDRO

  • 2

    DVM HYDRO UNIT

    DVM HYDRO UNIT Integrated solution in one system (air + water) Hot Water up to 80C and 50 C water High COP operation with heat recovery technology Integrated control system

    Optimized Solutionfor commercial use

    Floor Heating

    Fan Coil Unit

    Hot Water

    DHW Tank

    Outdoor Unit

    Hydro Unit

    Air Heating

    Air Cooling

  • 3

    DVM HYDRO UNIT

    DVM series EHS

    TARGET

    DVM S (DVM+4)

    DVM Mini2

    All-in-One

    More Efficient

    Free of ChargeHeating

    50 or 80 Water

    Wide range of units

    Space Saving

    Easy Install/Control

    Reliability

    EHS Mono/Split Low Temperature

    - Domestic, 50 water

    EHS High Temperature

    - Domestic, 80 water

    DVM S water

    POSITION FEATURE

    High Efficiency- High Efficiency Operation- Hot water with free of charge (HR)

    80, High Temp.- for Renewal building- can be equipped with smaller hot water tank

    Flexibility- Wide Range of Line-up- Various Indoor & Outdoor units

    Easy to Install- Quick & Easy Installation- Simple connection with BAS- Integrated Control

    Easy maintenance- S-net Monitoring Program

    Reliability- Pipe Anti-freezing operation- Anti-Bacteria operation

    01 Introduction

    MultiDomestic

    Commercial

  • 4

    DVM HYDRO UNIT

    Outdoor Indoor

    Refrigerant

    HeatingCooling

    50 / 80Water

    Hydro Unit / Hydro unit HT

    UFH FCU

    Indoor Unit (Air heating & cooling)

    Sanitary Hot Water

    Water

    DHW Tank

    DVM Hydro (NASA)/DVM Hydro HTDVM SDVM waterDVM geoDVM S Eco

    Combination 130%

    DVM HydroDVM Plus4DVM waterDVM Eco

    DVM (HP, HR)

    System conceptDVM outdoor unit /indoor units + DVM Hydro units for Underfloor heating, Fancoil unit, Sanitary Hot water

    Type Combination Ratio

    Air type Indoor unit 50% ~ 130%

    Hydro unit 100%

    Total 50% ~ 130%

  • 5

    DVM HYDRO UNIT

    03 Specification

    Hydro Unit Hydro Unit (NASA) Hydro Unit HT (NASA)

    Heating (kW) 16 / 31.5 / 50.4 16 / 31.5 / 50.4 16 / 25

    Power Source 1, 220-240V, 50/60 Hz 1, 220-240V, 50/60 Hz 3, 380-415V, , 50/60 Hz 1, 220-240V, 50/60 Hz

    Water Temp.() 50 50 80

    Refrigerant R410A R410AR410a

    R134a (Compressor inside)

    Size(WxDxH, mm) 520x1,210x330 520x1,210x330 520x627x330

    RTS RUNNING 13. 08 13. 08

    Outdoor UnitDVM+4 HP/HR

    DVM EcoDVM S HP/HR (13 07)

    DVM S HP/HR,

    DVM S Eco, DVM Water

    DVM S HP/HR, DVM S Eco

    DVM Water

    1,210 mm

    627 mm

  • 6

    DVM HYDRO UNIT

    03 SpecificationHeating Sanitary Hot Water

    -20

    25 80 Lwt()

    Outdoor Temp()

    35

    43

    -5

    5 25

    24

    -20

    25 50

    Outdoor Temp ()

    24

    -20

    25 80 Lwt()

    Outdoor Temp()

    Cooling

    Outdoor Temp ()

    Hyd

    ro U

    nit

    HT

    Hyd

    ro U

    nit

    -20~43C when Using HR and Outdoor unit is in the Cooling Mode

  • 7

    DVM HYDRO UNIT

    can be connected to all DVM S series (DVM S, DVM S HR, DVM Water, DVM mini2)

    can be also connected to AHU (Field Supply)

    HT unit (5/8HP)

    HE unit (5/10/16HP)

    DVM S DVM S HRDVM +4 HP/HR

    DVM WaterDVM Geo

    DVM S Eco

    AHU

    Water Heating

    Hot Water Supply

    Heat Source Hydro Unit Load

    UFH

    FCU

    03 Application

    DVM HYDRO

  • 8

    DVM HYDRO UNIT

    03 Application

    HU

    HotelDormitoryGymCommercial BuildingStore

    HU HU HU

  • 9

    DVM HYDRO UNIT

    03 Application

    HU

    HotelDormitoryGymCommercial BuildingStore

    HU HU HU

    MCU

  • 10

    DVM HYDRO UNIT

    03 Application

    HUHT

    HotelDormitoryGymCommercial BuildingStore

    HUHT

    HUHT

    HUHT

    MCU

    HU

    HU

    HU

    HU

  • 11

    DVM HYDRO UNIT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    U

    U

    U

    U

    U

    U

    HUHT

    03 ApplicationHigh Temperature SolutionResidenceApartmentFlat

  • 12

    DVM HYDRO UNIT

    03 ApplicationFarmGreen House

    HU

    HU

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    HU

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

    U

  • 13

    DVM HYDRO UNIT

    03 ApplicationPool VillaResidential House

    HU

    TitaniumHeat Exchanger

    DVM S EcoFJM orDVM S Eco

  • 14

    DVM HYDRO UNIT

    S-NET3I/M

    DVM Hydro

    Touch Controller

    On/OffController

    DMS2

    Controller

    BACnet

    04 Control Solution

  • 15

    DVM HYDRO UNIT

    Comm.

    TypeModel Type

    Power

    Supply

    Heating

    CapacityModel Name

    Outdoor Unit

    (DVM)RTS

    ConventionalDVM

    Hydro Unit

    Low Temp.

    (50)

    1, 220-240V,

    50Hz

    16 kW ADN160BDEHA/EUDVM+4 HP/HR

    DVM Eco13.01.0432 kW ADN320BDEHA/EU

    50 kW ADN500BDEHA/EU

    NASA

    DVM S

    Hydro Unit

    Low Temp.

    (50)

    1, 220-240V,

    50Hz

    16 kW AM160FNBDEH/EU

    DVM S HP/HR,

    DVM S Eco,

    DVM S Water13.08.31

    32 kW AM320FNBDEH/EU

    50 kW AM500FNBDEH/EU

    DVM S

    Hydro Unit

    HT

    High Temp.

    (80)

    1, 220-240V,

    50Hz

    16 kW AM160FNBFEB/EU

    25 kW AM250FNBFEB/EU

    3, 380-415V,

    50Hz

    16kW AM160FNBFGB/EU

    25 kW AM250FNBFGB/EU

    05 Launching Schedule (EU)

  • Back up

  • 18

    R134a cycle R410A R134a PHE

    FEATURE LT vs HT

    HYDRO UNIT HYDRO UNIT HT

    R410 A Water R410A R134AR134a Water

    Refrigerant temp water tempUp to 50C Up to 80C

    Outdoor Unit Water Side

    Outdoor Unit Water SideR134a Water PHE

    R410a Water PHE

  • 19

    DESIGN GUIDE

    Water pump

    HydroUnit

    Heating

    Water out

    Water in

    Manometer

    Thermistor

    Ball Valve Pressure Relief Valve(for HT)

    Expansion Vessel

    Drain (Hydro unit drain hole)

    Flexible Joint

    Ball Valve

    DHW

    3way V/V

    Water supplement V/V

    Cooling

    Parts should endure 10kg/ or more.Water Pipe: Brass or Stainless Steel

    Strainer (50mesh)

    UFH

    BufferTank

    FCU

  • 20

    SPACE HEATINGINSTALLATION

    1. Water pipe joint (union, flange)2. Thermometer3. Manometer4. Ball valve5. Flexible joint6. Drain (within the product)

    7. Pump8. Air vent9. Expansion tank10.Temperature sensor for thermal storage tank11.Drain valve12.Strainer (more than 50 mesh)

    PHE

    BufferTank

    FIELD SUPPLY

  • 21

    Domestic Hot WaterINSTALLATION

    FIELD SUPPLY SAMSUNG SUPPLY

    OrFIELD SUPPLY

    PHE

    1. Water pipe joint (union, flange)2. Thermometer3. Manometer4. Ball valve5. Flexible joint6. Drain (within the product)

    7. Pump8. Air vent9. Expansion tank10.Temperature sensor for thermal storage tank11.Drain valve12.Strainer (more than 50 mesh)

  • 22

    MCU KitINSTALLATION

    Model name Installation Examples Indoor Installation Remark

    MCU-Y4NEE

    - Under 10.0kW: Port 1EA- Up to 4units- 10.0kW ~ 14.0kW: Port 2EA- Big Duct: Not applicable- Max capacity: 46.4kW

    - If indoor units capacity is same or higher than 10.0kW using Y-joint is necessary. Otherwise, refrigerant noise could be generated from MCU Kit.

    MCU-Y6NEE- Under 10.0kW: Port 1EA- Up to 6units- 10.0kW ~ 14.0kW: Port 2EA- Big Duct: Not applicable- Max capacity: 46.4kW

    MCU-Y4NEE1

    - Up to 2 units- under 14.0kW: Not applicable- Big Duct: Port 2EA- Max capacity: 56.0kW

    Only for Big Duct( ND220HHXEA,ND280HHXEA)

    MCU

    7.1kW

    9.0kW

    14.0kW

    MCU

    7.1kW7.1kW

    14.0kW

    7.1kW7.1kW

    MCUBig Duct

    Big Duct

    ADN160BDEHA/EU : Y4NEE, Y6NEE and Y4NEE1 are available.

    ADN320BDEHA/EU : Y4NEE1 using Y-joint(2 ports)

    ADN500BDEHA/EU : MCU Kit is not allowed. Use two Hydro units(16+32kW)MCU-

    Y4NEE1

    16HP

    5HP

    MCU-

    Y4NEE1

    10HP

    5HP

    5HP

    MCU Connection (General)

    MCU Hydro unit Connection (Exceptional)

  • 23

    Flow RateDESIGN GUIDE

    Standard condition

    SectionInlet water

    temperature(C)

    Amount of water (/min)

    ADN160BDEH ADN320BDEH ADN500BDEHCooling 23

    48 92 150Heating 30

    Recommended Flow Rate

    SectionInlet water

    temperature(C)

    Amount of water (/min) Inlet water

    ADN160BDEH ADN320BDEH ADN500BDEHCooling 15~25

    24~48 46~92 75~150Heating 30~45