Dvm hydro sales Presentation
-
Author
haluk-tosun -
Category
Engineering
-
view
55 -
download
7
Embed Size (px)
Transcript of Dvm hydro sales Presentation
-
DVM HYDRO
-
2
DVM HYDRO UNIT
DVM HYDRO UNIT Integrated solution in one system (air + water) Hot Water up to 80C and 50 C water High COP operation with heat recovery technology Integrated control system
Optimized Solutionfor commercial use
Floor Heating
Fan Coil Unit
Hot Water
DHW Tank
Outdoor Unit
Hydro Unit
Air Heating
Air Cooling
-
3
DVM HYDRO UNIT
DVM series EHS
TARGET
DVM S (DVM+4)
DVM Mini2
All-in-One
More Efficient
Free of ChargeHeating
50 or 80 Water
Wide range of units
Space Saving
Easy Install/Control
Reliability
EHS Mono/Split Low Temperature
- Domestic, 50 water
EHS High Temperature
- Domestic, 80 water
DVM S water
POSITION FEATURE
High Efficiency- High Efficiency Operation- Hot water with free of charge (HR)
80, High Temp.- for Renewal building- can be equipped with smaller hot water tank
Flexibility- Wide Range of Line-up- Various Indoor & Outdoor units
Easy to Install- Quick & Easy Installation- Simple connection with BAS- Integrated Control
Easy maintenance- S-net Monitoring Program
Reliability- Pipe Anti-freezing operation- Anti-Bacteria operation
01 Introduction
MultiDomestic
Commercial
-
4
DVM HYDRO UNIT
Outdoor Indoor
Refrigerant
HeatingCooling
50 / 80Water
Hydro Unit / Hydro unit HT
UFH FCU
Indoor Unit (Air heating & cooling)
Sanitary Hot Water
Water
DHW Tank
DVM Hydro (NASA)/DVM Hydro HTDVM SDVM waterDVM geoDVM S Eco
Combination 130%
DVM HydroDVM Plus4DVM waterDVM Eco
DVM (HP, HR)
System conceptDVM outdoor unit /indoor units + DVM Hydro units for Underfloor heating, Fancoil unit, Sanitary Hot water
Type Combination Ratio
Air type Indoor unit 50% ~ 130%
Hydro unit 100%
Total 50% ~ 130%
-
5
DVM HYDRO UNIT
03 Specification
Hydro Unit Hydro Unit (NASA) Hydro Unit HT (NASA)
Heating (kW) 16 / 31.5 / 50.4 16 / 31.5 / 50.4 16 / 25
Power Source 1, 220-240V, 50/60 Hz 1, 220-240V, 50/60 Hz 3, 380-415V, , 50/60 Hz 1, 220-240V, 50/60 Hz
Water Temp.() 50 50 80
Refrigerant R410A R410AR410a
R134a (Compressor inside)
Size(WxDxH, mm) 520x1,210x330 520x1,210x330 520x627x330
RTS RUNNING 13. 08 13. 08
Outdoor UnitDVM+4 HP/HR
DVM EcoDVM S HP/HR (13 07)
DVM S HP/HR,
DVM S Eco, DVM Water
DVM S HP/HR, DVM S Eco
DVM Water
1,210 mm
627 mm
-
6
DVM HYDRO UNIT
03 SpecificationHeating Sanitary Hot Water
-20
25 80 Lwt()
Outdoor Temp()
35
43
-5
5 25
24
-20
25 50
Outdoor Temp ()
24
-20
25 80 Lwt()
Outdoor Temp()
Cooling
Outdoor Temp ()
Hyd
ro U
nit
HT
Hyd
ro U
nit
-20~43C when Using HR and Outdoor unit is in the Cooling Mode
-
7
DVM HYDRO UNIT
can be connected to all DVM S series (DVM S, DVM S HR, DVM Water, DVM mini2)
can be also connected to AHU (Field Supply)
HT unit (5/8HP)
HE unit (5/10/16HP)
DVM S DVM S HRDVM +4 HP/HR
DVM WaterDVM Geo
DVM S Eco
AHU
Water Heating
Hot Water Supply
Heat Source Hydro Unit Load
UFH
FCU
03 Application
DVM HYDRO
-
8
DVM HYDRO UNIT
03 Application
HU
HotelDormitoryGymCommercial BuildingStore
HU HU HU
-
9
DVM HYDRO UNIT
03 Application
HU
HotelDormitoryGymCommercial BuildingStore
HU HU HU
MCU
-
10
DVM HYDRO UNIT
03 Application
HUHT
HotelDormitoryGymCommercial BuildingStore
HUHT
HUHT
HUHT
MCU
HU
HU
HU
HU
-
11
DVM HYDRO UNIT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
U
U
U
U
U
U
HUHT
03 ApplicationHigh Temperature SolutionResidenceApartmentFlat
-
12
DVM HYDRO UNIT
03 ApplicationFarmGreen House
HU
HU
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
HU
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
-
13
DVM HYDRO UNIT
03 ApplicationPool VillaResidential House
HU
TitaniumHeat Exchanger
DVM S EcoFJM orDVM S Eco
-
14
DVM HYDRO UNIT
S-NET3I/M
DVM Hydro
Touch Controller
On/OffController
DMS2
Controller
BACnet
04 Control Solution
-
15
DVM HYDRO UNIT
Comm.
TypeModel Type
Power
Supply
Heating
CapacityModel Name
Outdoor Unit
(DVM)RTS
ConventionalDVM
Hydro Unit
Low Temp.
(50)
1, 220-240V,
50Hz
16 kW ADN160BDEHA/EUDVM+4 HP/HR
DVM Eco13.01.0432 kW ADN320BDEHA/EU
50 kW ADN500BDEHA/EU
NASA
DVM S
Hydro Unit
Low Temp.
(50)
1, 220-240V,
50Hz
16 kW AM160FNBDEH/EU
DVM S HP/HR,
DVM S Eco,
DVM S Water13.08.31
32 kW AM320FNBDEH/EU
50 kW AM500FNBDEH/EU
DVM S
Hydro Unit
HT
High Temp.
(80)
1, 220-240V,
50Hz
16 kW AM160FNBFEB/EU
25 kW AM250FNBFEB/EU
3, 380-415V,
50Hz
16kW AM160FNBFGB/EU
25 kW AM250FNBFGB/EU
05 Launching Schedule (EU)
-
Back up
-
18
R134a cycle R410A R134a PHE
FEATURE LT vs HT
HYDRO UNIT HYDRO UNIT HT
R410 A Water R410A R134AR134a Water
Refrigerant temp water tempUp to 50C Up to 80C
Outdoor Unit Water Side
Outdoor Unit Water SideR134a Water PHE
R410a Water PHE
-
19
DESIGN GUIDE
Water pump
HydroUnit
Heating
Water out
Water in
Manometer
Thermistor
Ball Valve Pressure Relief Valve(for HT)
Expansion Vessel
Drain (Hydro unit drain hole)
Flexible Joint
Ball Valve
DHW
3way V/V
Water supplement V/V
Cooling
Parts should endure 10kg/ or more.Water Pipe: Brass or Stainless Steel
Strainer (50mesh)
UFH
BufferTank
FCU
-
20
SPACE HEATINGINSTALLATION
1. Water pipe joint (union, flange)2. Thermometer3. Manometer4. Ball valve5. Flexible joint6. Drain (within the product)
7. Pump8. Air vent9. Expansion tank10.Temperature sensor for thermal storage tank11.Drain valve12.Strainer (more than 50 mesh)
PHE
BufferTank
FIELD SUPPLY
-
21
Domestic Hot WaterINSTALLATION
FIELD SUPPLY SAMSUNG SUPPLY
OrFIELD SUPPLY
PHE
1. Water pipe joint (union, flange)2. Thermometer3. Manometer4. Ball valve5. Flexible joint6. Drain (within the product)
7. Pump8. Air vent9. Expansion tank10.Temperature sensor for thermal storage tank11.Drain valve12.Strainer (more than 50 mesh)
-
22
MCU KitINSTALLATION
Model name Installation Examples Indoor Installation Remark
MCU-Y4NEE
- Under 10.0kW: Port 1EA- Up to 4units- 10.0kW ~ 14.0kW: Port 2EA- Big Duct: Not applicable- Max capacity: 46.4kW
- If indoor units capacity is same or higher than 10.0kW using Y-joint is necessary. Otherwise, refrigerant noise could be generated from MCU Kit.
MCU-Y6NEE- Under 10.0kW: Port 1EA- Up to 6units- 10.0kW ~ 14.0kW: Port 2EA- Big Duct: Not applicable- Max capacity: 46.4kW
MCU-Y4NEE1
- Up to 2 units- under 14.0kW: Not applicable- Big Duct: Port 2EA- Max capacity: 56.0kW
Only for Big Duct( ND220HHXEA,ND280HHXEA)
MCU
7.1kW
9.0kW
14.0kW
MCU
7.1kW7.1kW
14.0kW
7.1kW7.1kW
MCUBig Duct
Big Duct
ADN160BDEHA/EU : Y4NEE, Y6NEE and Y4NEE1 are available.
ADN320BDEHA/EU : Y4NEE1 using Y-joint(2 ports)
ADN500BDEHA/EU : MCU Kit is not allowed. Use two Hydro units(16+32kW)MCU-
Y4NEE1
16HP
5HP
MCU-
Y4NEE1
10HP
5HP
5HP
MCU Connection (General)
MCU Hydro unit Connection (Exceptional)
-
23
Flow RateDESIGN GUIDE
Standard condition
SectionInlet water
temperature(C)
Amount of water (/min)
ADN160BDEH ADN320BDEH ADN500BDEHCooling 23
48 92 150Heating 30
Recommended Flow Rate
SectionInlet water
temperature(C)
Amount of water (/min) Inlet water
ADN160BDEH ADN320BDEH ADN500BDEHCooling 15~25
24~48 46~92 75~150Heating 30~45