Datos del proyecto Características de los materialesf'c (kg/cm2) 280 CEMENTO ARENA GRAVARevenim. Cm 10 P.V.S.S 1510 1920 1540Rel. A/C 0.46 DENSIDAD 3.1 2.6 2.74Lts. Agua/Saco ABSORCION 2.5 1.8
M.F. 2.8TAM. MAXIMO 99 mmHUMEDAD 0 0
MATERIALES PESO VOLUMEN COMPROBACIONRel. A/C 0.46 1.426Rel. G/A 1.38 1.30948905109AGUA 187.5 187.5 COLUMNA 1 = 2419.78235717064CEMENTO 131.467LECHADA 318.987AGREGADOS 681.013ARENA 294.94GRAVA 386.08
3 2 4 5 6
MATERIALES PESO KG VOLUMEN LTSCEMENTO 50 1 33.112582781 1 16.129032258AGUA 23.0034423 0.46006884593 23.003442296 0.69470395735 23.003442296ARENA 94.08027576 1.88160551513 49.000143623 1.47980433742 36.184721445GRAVA 129.783483 2.59566966026 84.27498897 2.54510466688 47.366234676
SUMA 296.8672011 122.68343068
CEMENTO ARENA GRAVAPROPORCIÓN 1 1.47980433742 2.5451046669
CORRECCIÓN POR HUMEDAD Y ABSORCIÓN
MATERIALES KG/CM3 HUMEDAD ABSORCIÓN% KG % KG
CEMENTO 407.5477AGUA 187.5ARENA 766.844 0 0 2.5 19.1711GRAVA 1057.8592 0 0 1.8 19.0414656
PROPORCIÓN PESO
PROPORCION VOL.
VOLÚMENES ABSOLUTOS
![Page 2: Dosificacion - Metodo de Abrams](https://reader036.fdocuments.ec/reader036/viewer/2022072106/5695cffd1a28ab9b029072ff/html5/thumbnails/2.jpg)
SUMA 2419.7509 0 38.2125656
![Page 3: Dosificacion - Metodo de Abrams](https://reader036.fdocuments.ec/reader036/viewer/2022072106/5695cffd1a28ab9b029072ff/html5/thumbnails/3.jpg)
COMPROBACION
2419.78235717064
PROPORCIONAMIENTO FINAL
1 3 2 4 5 6
KG/M3 MATERIALES PESO KG VOLUMEN LTS407.5477 CEMENTO 50 1 33.112582781 1 16.129032258
187.5 AGUA 27.6915519 0.55383103769 27.691551885 0.83628486691 27.691551885766.844 ARENA 91.7282689 1.83456537726 47.775140033 1.44280922899 35.280103409
1057.8592 GRAVA 127.44738 2.54894760638 82.758039168 2.49929278288 46.513642452
2419.7509 SUMA 296.867201 125.61433
CEMENTO ARENAPROPORCIÓN 1 1.442809229
CORRECCIÓN POR HUMEDAD Y ABSORCIÓN
KG/CM3
407.5477225.712566
747.67291038.81773
PROPORCIÓN PESO
PROPORCION VOL.
VOLÚMENES ABSOLUTOS
![Page 4: Dosificacion - Metodo de Abrams](https://reader036.fdocuments.ec/reader036/viewer/2022072106/5695cffd1a28ab9b029072ff/html5/thumbnails/4.jpg)
2419.7509
![Page 5: Dosificacion - Metodo de Abrams](https://reader036.fdocuments.ec/reader036/viewer/2022072106/5695cffd1a28ab9b029072ff/html5/thumbnails/5.jpg)
PROPORCIONAMIENTO FINAL
1
KG/M3407.5477
225.712566747.6729
1038.81773
2419.7509
GRAVA2.49929278