 Tipo Documento INFORME Código DNF-INFO-20383 Revisión 2 Fecha de aprobación 17/11/2006 confidencial Grupo France Telecom Página 1 de 19    U    N    A    V    E    Z    I    M    P    R    E    S    O     P    U    E    D    E    E    S    T    A    R    O    B    S    O    L    E    T    O  ,    A    S    E    G     Ú    R    E    S    E    D    E    U    T    I    L    I    Z    A    R    L    A    V    E    R    S    I     Ó    N    E    N    V    I    G    O    R  CONFIGURACIÓN DE TMAs POWERWAVE EN NODOS B ERICSSON  Elaborado por Dir/Unidad Fecha Elaboración José Aurelio Sánchez Arribas Ingeriría / DNF 17/10/2006 Lista de distribución Planning (Diseño y Planes) Roll-Out (IE & PPM) Soporte Técnico Especialista (O&M)  TRC OSS BDR Revisado por: Aprobado por: José Pablo Ruiz Jiménez Pedro Serna Dir/Unidad Dir/Unidad Ingeriría / DNF Ingeriría / DNF

Transcript of Dnf-Info-20383 Configuracion de Tmas Powerwave en Nodos b Ericsson

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

CONFIGURACIN DE TMAs POWERWAVE EN NODOS B ERICSSONElaborado por Jos Aurelio Snchez Arribas Lista de distribucin Dir/Unidad Ingerira / DNF Fecha Elaboracin 17/10/2006

Planning (Diseo y Planes) Roll-Out (IE & PPM) Soporte Tcnico Especialista (O&M) TRC OSS BDR

Revisado por: Jos Pablo Ruiz Jimnez Dir/Unidad Ingerira / DNF

Aprobado por: Pedro Serna Dir/Unidad Ingerira / DNF

confidencial Grupo France Telecom

Pgina 1 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

NDICE DE REVISIONES

N REVISINUNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

MODIFICACIONES RESPECTO A LA REVISIN ANTERIOR

N REVISIN 1 2

MODIFICACIONES RESPECTO AL INFORME ANTERIOR

Versin Inicial Configuracin de la MCU y del Nodo B con TMA no Ericsson

confidencial Grupo France Telecom

Pgina 2 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

ndice1.UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

OBJETO ............................................................................................................... 4 ALCANCE ............................................................................................................. 4 DOCUMENTACIN DE REFERENCIA ....................................................................... 4 Descripcin del sistema........................................................................................... 4 Aplicacin de TMA Powerwave en Nodo B Ericsson.................................................. 10 5.1 5.2 Configuracin de la MCU y del Nodo B con TMA no Ericsson ............................. 10 CONSIDERACIONES DE instalacin del sistema ............................................... 10

2. 3. 4. 5.

6.

Definiciones ......................................................................................................... 10

confidencial Grupo France Telecom

Pgina 3 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

1.

OBJETO

Describir la configuracin estndar para el uso de TMAs de Powerwave en Nodos B de Ericsson.UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

2.

ALCANCE

El presente documento afecta a la DNF de Orange Espaa.

3.N[1]

DOCUMENTACIN DE REFERENCIAREFERENCIA TTULO J:\Area RET Manual 7005_R1C DNF\_Privada\CdsDeRed\Sistem a Radiante, DDEE e Instrumentacion\TMAs\Powerwa ve\01-Informacin producto Sistema RET en Antenas GSMTYR-INFO-12961 UMTS norma de instalacin de alarmas DNF-PROC-20355 TMA de Powerwave en Nodos B de Ericsson EDITOR Powerwave

[2] [3]

Jos Aurelio Snchez Roll Out/ Equipment Implementation

4.

Descripcin del sistema

El sistema de PowerWave, consta de tres elementos, el TMA, la unidad CILOC y la unidad MCU, los cuales se describen a continuacin: 1. TMA: El TMA de powerwave es un Dual Duplex TMA denominado LGP167 que consta de 2 LNAs de 60 MHz en una misma carcasa. De este modo podemos conectar los conectores de una antena de doble polarizacin (+45 / -45) directamente al TMA, es decir, la recepcin directa de la antena y la de diversidad.

confidencial Grupo France Telecom

Pgina 4 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

El TMA solo puede ser alimentado a travs del cable coaxial (feeder) por dos mtodos, uno de ellos es desde la caseta mediante un inyector de corriente en el coaxial, si los dispositivos pasivos como diplexores, triplexores y/o combinadores lo permiten, y el otro mtodo es cuando los dispositivos pasivos no permiten alimentar al TMA desde la caseta, para ello se instalan los cables externos correspondientes desde la MCU hasta el inyector que estar ubicado junto al TMA. Hay que tener presente que slo es necesario alimentar al TMA a travs de un nico coaxial, no es necesario a travs de los dos coaxiales. Existen dos versiones del TMA LGP167, la que corresponde con una ganancia fija de 12 dB y la que corresponde con una ganancia variable de 23 a 32 dB. La segunda versin es la que se debe de utilizar con Nodos B de Ericsson y ajustarla a 27 dB, que es la ganancia correspondiente al ASC de Ericsson. El TMA de ganancia fija tiene como Product Number: LGP167.20 y la versin con ganancia variable tiene como Product Number: LGP167.21 Las caractersticas del TMA LGP167.21 son las siguientes: LGP167.21 Frequency range, full band (60 MHz) Nominal gain (dB) Noise figure* Output 3rd order Intercept Point* (OIP3) Frequency range, full band (60 MHz) Insertion loss* (dB) Return loss (dB) 2 Tx@x43 dBm (dBc) Two levels, individually supervised LNAs Power Supply Consumption @12 VDC Size, W x H x D (without mounting plate) Weight Colour Housing RF-connectors Mounting kit Temperature range MTBF Safety Ingress protection, IP 65 Environmental EMC AISG 1.0, 1.1 Connector Type Pin 6/7 current handling 10 30 V. 8 W per LNA 169 x 272.5 x 67.7 mm 1 million hours EN 60 950 EN 60 529 ETS 300 019 ETS 125 113 Data rate 9.6 kbps IEC 60130-9 (Ed. 3.0) female 1.3 A 1920-1980 MHz 23-32 1.4 dB +37 dBm 2110-2170 0.3 >20. -168

Up-link

Down-link Intermodulation Alarm Functionality Power

Mechanical Data

Environmental Data Approvals and Tests AISG Compatibility

confidencial Grupo France Telecom

Pgina 5 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

2. Unidad CILOC (Current Injector Layer One Converter): Se trata de un inyector de corriente que a su vez es capaz de transferir la informacin en capa 1 del protocolo AISG. Con el uso de este dispositivo es posible utilizar los cables coaxiales para poder alimentar al TMA y el envo de los comandos necesarios para la supervisin. A continuacin vemos una imagen de la unidad CILOC.

La unidad CILOC tiene dos versiones en funcin de su ubicacin en el sistema radiante. Si la unidad CILOC va a ser instalada, junto al Nodo B, para inyectar desde la MCU la seal de control y alimentacin al cable coaxial deberemos emplear la versin BTS CILOC. Por otro lado, si la unidad CILOC va a ser instalada junto al TMA para inyectar desde el cable coaxial la seal de control y alimentacin al TMA, deberemos emplear la versin ANTENNA CILOC. La diferencia tcnica entre ambas versiones es el conector AISG utilizado (para alimentacin y control del TMA desde la MCU), puesto que para la versin ANTENNA es un conector estndar AISG hembra y para la versin BTS es un conector AISG macho. A continuacin vemos las dos versiones de la unidad CILOC, donde se aprecian las diferencias en los conectores AISG:

Las caractersticas de la unidad CILOC son las siguientes: Product Number Frequency range Insertion Loss Return Loss ANT port Return Loss BTS port Passive intermodulation at 2X43dBm Power handling Power supply 7060.00 (Antena CILOC) 7060.10 (BTS CILOC) 806-960 MHz and 1710-2180 MHZ 20 dB >20dB 500.000 hrs. IP65 ETSI 300 019Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Current consumption Current handling AISG data rate Weight Dimensions (W,L,H) (mm) RF connectors AISG Antena connector AISG BTS connector Protection Ground Operation temperature range Type Approvals

MTBF Ingress protection Environmental

3. Master Control Unit (MCU): Es la unidad encarga de controlar, supervisar y suministrar alimentacin al TMA va un Bus Comn. A la MCU podemos conectarnos localmente, a travs del conector RS232 o remotamente va IP, y si la Estacin Base (Nodo B o BTS) tiene interfaces externos, la MCU podra ser conectada directamente a travs del puerto Site LAN a la Estacin Base. Tambin, si la Estacin Base es compatible con AISG, la unidad MCU no sera necesaria, pero no es el caso de Ericsson. La MCU puede ser integrada en el OMC del suministrador del Nodo B, que para el caso de Ericsson es el OSS RC, o bien, una solucin propietaria a travs de un Web-Browser o cliente SNMP, mediante el conector Site LAN o mdem. La unidad MCU no posee mdem GSM interno, por tanto, sera necesario conectar uno externo con el puerto RS-232 de la MCU, si se desea un acceso remoto a travs de GSM/GPRS. La MCU es compatible con la plataforma de red de Powerwave denominada NetWay Manage (NWM). La MCU de Powerwave puede manejar hasta un mximo de 3 TMAs, por tanto, si en algn emplazamiento existen ms de 3 TMAs sera necesario instalar 2 MCUs. A continuacin vemos una imagen real de la unidad MCU instalada en el trial de Barcelona:

La MCU se instala en un rack de 19 y tiene una altura de 1U, tal y como muestra la siguiente figura:confidencial Grupo France Telecom Pgina 7 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

La MCU puede ser alimentada a 220Vac, a +24Vdc y a 48Vdc. En nuestro caso ser siempre alimentada a 48Vdc, para de este modo poder tener alimentacin a travs de las bateras de la caseta cuando exista un fallo de suministro elctrico. En nuestro caso, siempre se va a alimentar a la MCU a -48Vdc por tanto junto con la MCU se suministra el cable y conector (tipo Mate-N-Lok) de alimentacin en DC, para ello sera necesario nicamente montar en el otro extremo del cable un conector compatible con la fuente de alimentacin en DC de la caseta. Para ello hay que considerar que el cable a tierra es el de color NEGRO. La MCU tiene dos salidas de alarmas (Local control ports, output ports) para conectar con el panel de alarmas de la RBS, y de este modo visualizar la alarma procedente del TMA. Cada alarma consta de un rele del tipo conmutador o tambin denominado NCNO (normalmente cerrado normalmente abierto). Cuando la MCU est sin alarmas, el rele conecta el conector comn con el conector NC (normalmente cerrado) y cuando la MCU est alarmada, el rele conmuta al conector NO (normalmente abierto), y aparecer un Warnning en el OSS RC de Ericsson. Vase la siguiente imagen para entender mejor el funcionamiento de las alarmas.

confidencial Grupo France Telecom

Pgina 8 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Solo se configuraran las alarmas a travs del Rele 1, y se conectarn al panel de alarmas del Nodo B que quedan libres. De este modo, se podrn supervisar las alarmas de la MCU y TMA a travs del Nodo B. Los conectores del rele de alarmas son del tipo Connector Panel de mtrica 2, el cual puede ser extrado de la MCU para una mejor conexin de los cables, los cuales tienen que ser de una seccin mxima de 1,5 mm. Para ello, deberemos conectar el Rel 1 de la MCU, contactos comn y NO, al mdulo 8, posiciones 1&2 de la EACU, que corresponde con la entrada de alarmas N 15 de la RBS. Tambin, se deber configurar en el apartado de alarmas externas del equipo RBS3202, la entrada 15 como Alarma de TMA. Para ms informacin recomendamos leer la norma de instalacin de alarmas TMA de Powerwave en Nodos B de Ericsson, DNF-PROC20355, en la que se explica paso a paso y detalladamente las instrucciones a seguir para la instalacin. Los conectores del TMA son denominados Cables ALD por Powerwave y son del tipo IEC 60130-9 (Ed. 3.0). A continuacin vemos una imagen con la denominacin de los conectores:

Las caractersticas de la MCU son las siguientes: Product Number (-48V) Power supply DC / Current consumption TMA supply voltage Max current draw per connector Total current draw all connectors Local alarm ports (IN port) Local control ports (Out ports, 3-pole relays) AISG data rate Weight 7070.50 -48V -48V /< 2.5A +24 V DC 1.16 A 3.48 A Output voltage at open Output current at closed Max input Voltage Max input current 9.6 kbps, 38.4 kbps < 2,5 kg 5 1 V 5 2mA 30 V DC 0.5 A

confidencial Grupo France Telecom

Pgina 9 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006 Width 19 rack, (1U) Height 44mm, Depth 207mm DC power supply CAP 2 Circuit universal MATE-N-LOK 350778-1 AC power supply IEC/EB60320-1 Male TMA 1 to 3 IEC 60130-9 (Ed. 3.0) Site LAN 4-pole RJ45 MDI Local (Ethernet port) 4-pole RJ45 MDI RS-232 9-pin d-SUB male Local alarm Connector panel Conformity with the relevant provision(s)of the directives RTTE 99/5/EG and LVD 73/23/EEG. >250.000 hrs. -5C to 60C ETSI 300 019 * Weather-protected locations*Revisin 2

Dimensions

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Connectors

Type Approvals MTBF Operating temperature Environmental

5.

Aplicacin de TMA Powerwave en Nodo B Ericsson

Para el caso de instalacin de un TMA Powerwave en un emplazamiento con Nodo B Ericsson es necesario instalar la MCU, un inyector CILOC y el TMA en cuestin. Y para ello existen dos posibilidades, una a travs de cable coaxial (feeder) desde la caseta y otra a travs de un cable externo hasta el CILOC situado junto al TMA, tal y como muestran las siguientes figuras:

TMA

TMA

TMA ANTENN A

TMA

TMA

TMA

BTS CILO

MCU

MCU

Figura a) control y alimentacin desde la caseta

NODO B

Figura b) control y alimentacin con cable externo

NODO B

confidencial Grupo France Telecom

Pgina 10 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

La instalacin de la figura a), alimentacin y control desde la caseta a travs del cable coaxial, es la instalacin recomendada, pero en ocasiones no es posible debido a que los dispositivos pasivos empleados como diplexores, triplexores y/o combinadores no permiten el paso de corriente, por tanto, ser necesario recurrir a la instalacin de la figura b), para alimentar y supervisar al TMA con cables externos.UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Una vez instalado el TMA y la MCU se deber conectar a la MCU la alimentacin del emplazamiento, as como las alarmas que dispone la MCU con el panel de alarmas externas de la caseta del emplazamiento y de este modo visualizar la alarma procedente del TMA. Para la comunicacin remota con la MCU se pueden utilizar dos mtodos, bien a travs del conector RS232 y con un mdem, o bien a travs del Nodo B conectado con el puerto SITE LAN de la MCU. En cualquiera de los dos casos, es necesario poner en la web residente de la MCU una direccin IP al dispositivo, para ello es necesario conectarnos localmente a la MCU durante la instalacin. Para conectarnos a la MCU a travs de la subred del Nodo B es necesario comunicarle al Nodo B que un dispositivo con direccin IP xxxxxx se ha conectado a la subred del Nodo B, as mismo, es necesario introducir en la MCU la direccin IP de la subred del Nodo B. Para ms informacin de la puesta en marcha del sistema recomendamos que el instalador siga las instrucciones de instalacin del manual de usuario (User`s Manual RET Manual 7005_R1C), en el que se explica paso a paso y detalladamente las instrucciones a seguir en la web residente para la primera instalacin. Uno de los parmetros a introducir en la web residente de la MCU es la ganancia del TMA, que deber ser de 27 dB, por ser la misma ganancia que utiliza el TMA (ASC) de Ericsson. No obstante, la ganancia podra ser mayor, hasta 32 dB, en funcin de la longitud del cable coaxial (feeder), como ocurre con el ASC de Ericsson.

5.1 Configuracin de la MCU y del Nodo B con TMA no EricssonAl Nodo B es necesario comunicarle que se ha instalado un TMA en el sector correspondiente, y que dicho TMA no es Ericsson, y que ser alimentado de forma externa al Nodo B, adems de los valores de los parmetros que Planning debe indicar en el CDR para configurar el Nodo B con un TMA externo. Los valores de dichos parmetros viene por defecto cuando se instala el TMA ASC de Ericsson, para el caso de un TMA externo los valores y parmetros son los siguientes:long Dejar el valor por defecto long Dejar el valor por defecto long Dejar el valor por defecto long Dejar el valor por defecto long Obligatorio Attributes currentHighLimA = 180 { 0..600 } Indicates the higher current limit when LNA failure shall be reported for branch A. This attribute is only valid for configurations with FU 1900. UNIT=mA currentHighLimB = 180 { 0..600 } Indicates the higher current limit when LNA failure shall be reported for branch B. This attribute is only valid for configurations with FU 1900. UNIT=mA currentLowLimA = 50 { 0..200 } Indicates the lower current limit when LNA failure shall be reported for branch A. This attribute is only valid for configurations with FU 1900. UNIT=mA currentLowLimB = 50 { 0..200 } Indicates the lower current limit when LNA failure shall be reported for branch B. This attribute is only valid for configurations with FU 1900. UNIT=mA dlAttenuation { 0..500 } Indicar la atenuacin que introduce el feeder en Downlink. Example: 50 = 5.0 dB UNIT=0.1(dB)

confidencial Grupo France Telecom

Pgina 11 de 19

Tipo Documento Cdigo Fecha de aprobacin long

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

dlTrafficDelayA { 0..2000 } Indicar el retardo que introduce el feeder en Downlink. Example: 312 = 31.2 ns UNIT=0.1(ns) RECOMMENDED VALUE=300 long dlTrafficDelayB { 0..2000 } Indicar el retardo que introduce el feeder en Downlink. Example: 312 = 31.2 ns UNIT=0.1(ns) RECOMMENDED VALUE=300 string ExternalTmaId noNotification Indicar el nmero id del TMA. Por defecto=1 restricted Indicates the id number of the external TMA. ExtTMA_InternalPower internalPower Obligatorio Indicar como es alimentado el TMA externo. NO=no alimentado por la RBS. YES=la RBS alimenta al TMA a travs del feeder. Se debe indicar NO. ExtTMA_tmaDegraded tmaDegradedSupported = NO Supported Indicates whether the TMA support reporting of degraded functionality. Dejar el valor por The attribute is only valid for configurations with FU 1900. No: The TMA does not defecto support reporting of degraded functionality in a similar way as for Ericsson TMA. Yes: The TMA does support reporting of degraded functionality in a similar way as for Ericsson TMA. long ulGain { 0..360 } Obligatorio Ganancia uplink con la que se configurado el TMA. Example: 270 = 27.0 dB UNIT=0.1(dB) long ulTrafficDelayA { 0..2000 } Indicar el retardo que introduce el feeder en Uplink. Example: 312 = 31.2 ns UNIT=0.1(ns) RECOMMENDED VALUE=300 long ulTrafficDelayB { 0..2000 } Indicar el retardo que introduce el feeder en Uplink. Example: 312 = 31.2 ns UNIT=0.1(ns) RECOMMENDED VALUE=300

NOTA: slo es obligatorio configurar los parmetros de TMA y alimentacin del TMA. El resto de parmetros son vlidos los establecidos a travs del CDR. En la siguiente ilustracin se muestra como se configuro el Nodo B durante la FOA:

confidencial Grupo France Telecom

Pgina 12 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Configuracin de la MCU: Como se ha indicado anteriormente, el software de configuracin de la MCU es residente en la propia MCU, por tanto tan solo es necesario conectarse con el PC a la MCU a travs de un cable cruzado para RS232. Los parmetros que se deben configurar en el nodo B son los siguientes: Location (Recomendable). MCU Id (Recomendable). Ganancia de cada TMA instalado (Obligatorio) IPs (obligatorio). NTP (Recomendable). Igual que el del Nodo B.

confidencial Grupo France Telecom

Pgina 13 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

Alarmas hacia el Rel 1, con la criticidad cleared desactivadas (establecidas como puerto=SNMP), slo establecer Major o Minor.

Para entrar en la aplicacin de la MCU, el usuario y la password son los siguientes.UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Access level Surveillance ALD Configuration Network Configuration

User name Level1 Level2 Level3

Default password public private private

Description Read access only. Write access to parameters for ALD configuration. Write access to configuration parameters for the management network.

En la siguiente ilustracin se muestra como se configuro la identifico de la MCU durante la FOA:

En las siguientes ilustraciones se muestra como se configuro la Ganancia de uno de los TMAs durante la FOA:

confidencial Grupo France Telecom

Pgina 14 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

En las siguientes ilustraciones se muestra como se configuro las IPs de la MCU durante la FOA:confidencial Grupo France Telecom Pgina 15 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

IPs establecidas en el Nodo B: Nodo B IP SubnetMask BroadcastAdress MADB3779 10.163.21.233 255.255.255.248 10.163.21.239UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

confidencial Grupo France Telecom

Pgina 16 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

IPs establecidas en la MCU, deben ser las siguientes: IP: una ms que la del nodo: 10.163.21.234 Mscara y Default Gateway.UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Una vez configuradas la IPs en la MCU, es posible supervisar y controlar la MCU de forma remota a travs de la LAN del Nodo B. El cable de datos entre la MCU y el Nodo B debe ser un cable recto. Durante la FOA las IPs se establecieron del siguiente modo:

RX21 Nodo B IP: 10.163.21.233 RX22 10.163.177.2 33 MCU IP: 10.163.21.234 Mask: 10.163.21.248 Default Gateway: 10.163.21.233

confidencial Grupo France Telecom

Pgina 17 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

En la siguiente ilustracin se muestra como se configuraron las alarmas externas de la MCU para slo el Rele 1:

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Los Product Number de los dispositivos a utilizar son los siguientes: TMA: LGP167.21; por ser un TMA de 60 MHz de ancho de banda y una ganancia variable de 23 a 32 dB. CILOC: 7060.00 (Antena CILOC) 7060.10 (BTS CILOC). El empleo de uno u otro ser funcin de la instalacin. MCU: 7070.50 ; por ser una MCU alimentada a 48 Vdc. CABLES EXTERNOS ALD:Product Number. 7085.05 7085.15 7085.30 7085.50 7095.10 7095.20 7095.40 7095.60 7095.80 CABLES ALD (De la MCU al CILOC) Descripcin Comentarios Cable de 0,5 m Cable de 1,5 m 5-wire cable for connecting an MCU to a BTS CILOC Cable de 3 m Cable de 5 m Cable de 10 m Cable de 20 m Cable de 40 m 5-wire cable for connecting an MCU to a ANTENNA CILOC Cable de 60 m Cable de 80 m

confidencial Grupo France Telecom

Pgina 18 de 19

Tipo Documento Cdigo Fecha de aprobacin

INFORME DNF-INFO-20383 17/11/2006Revisin 2

5.2 CONSIDERACIONES DE instalacin del sistemaSe recomienda que el instalador anote en una etiqueta o similar el nmero de serie del TMA a instalar y el sector en el que se instala, para evitar de este modo volver a subir a la torre para verificarlo, puesto que es necesario introducirlo en la web residente de la MCU en la primera puesta en funcionamiento. Tal y como muestra la siguiente figura:

UNA VEZ IMPRESO PUEDE ESTAR OBSOLETO, ASEGRESE DE UTILIZAR LA VERSIN EN VIGOR

Por ultimo, NO se debe instalar un descargador entre el TMA y la unidad CILOC, porque este dispositivo podra provocar una interrupcin del paso de corriente necesario para el funcionamiento del TMA.

6. DefinicionesAISG = Antenna Interface Standards Group ALD = Dispositivos de antena. ASC = Antenna System Controller (TMA Ericsson). CILOC = Current Injector Layer One Converter (Inyector de corriente de Powerwave). DNF = Domestic Network Factory (Orange Spain). EMC = Electronic Magnetic Compatible. LNA = Low Noise Amplifier MCU = Master Control Unit. MTBF = Mean Time Between Failure. NO = Normalmente Abierto. NC = Normalmente Cerrado. NWM = NetWay Manager (sofware de supervision de Powerwave) TMA = Amplificador de Torre de Bajo Nivel de Ruido para el enlace ascendente.