Transcript of CABLEDO ESTRUCTURADO

TELEMTICA I

TELEMTICA I2012

UNIVERSIDAD NACIONAL DE SAN AGUSTN

FACULTAD DE PRODUCCIN Y SERVICIOS

ESCUELA PROFESIONAL DE INGENIERA ELECTRNICA

CURSO:TELEMTICA I

TEMA:CABLEADO ESTRUCTURADO

PRESENTADO POR:CHVEZ BELLIDO, JUAN CARLOS20070932PACCORICHOQUEHUAYTA, RODOLFO20050250

DOCENTE:ING.ERASMO SULLA ESPINOZA

AREQUIPA PER2012

CABLEADO ESTRUCTURADO1. ELEMENTOSCableado HorizontalLa norma EIA/TIA 568A define el cableado horizontal de la siguiente forma: El sistema de cableado horizontal es la porcin del sistema de cableado de telecomunicaciones que se extiende del rea de trabajo al cuarto de telecomunicaciones o viceversa. El cableado horizontal consiste de dos elementos bsicos: Cable Horizontal y Hardware de Conexin (tambin llamado "cableado horizontal") que proporcionan los medios bsicos para transportar seales de telecomunicaciones entre el rea de trabajo y el cuarto de telecomunicaciones. Estos componentes son los "contenidos" de las rutas y espacios horizontales. Rutas y Espacios Horizontales (tambin llamado "sistemas de distribucin horizontal"). Las rutas y espacios horizontales son utilizados para distribuir y soportar cable horizontal y conectar hardware entre la salida del rea de trabajo y el cuarto de telecomunicaciones. Estas rutas y espacios son los "contenedores" del cableado Horizontal.1.- Si existiera cielo raso suspendido se recomienda la utilizacin de canaletas para transportar los cables horizontales.2.- Una tubera de in por cada dos cables UTP.3.- Una tubera de 1in por cada cable de dos fibras pticas.4.- Los radios mnimos de curvatura deben ser bien implementados.

El cableado horizontal incluye: Las salidas (cajas/placas/conectores) de telecomunicaciones en el rea de trabajo. En ingls: WorkAreaOutlets (WAO). Cables y conectores de transicin instalados entre las salidas del rea de trabajo y el cuarto de telecomunicaciones. Paneles de empalme (patchpanels) y cables de empalme utilizados para configurar las conexiones de cableado horizontal en el cuarto de telecomunicaciones.

Se deben hacer ciertas consideraciones a la hora de seleccionar el cableado horizontal: contiene la mayor cantidad de cables individuales en el edificio.Consideraciones de diseo: los costes en materiales, mano de obra e interrupcin de labores al hacer cambios en el cableado horizontal pueden ser muy altos. Para evitar estos costes, el cableado horizontal debe ser capaz de manejar una amplia gama de aplicaciones de usuario. La distribucin horizontal debe ser diseada para facilitar el mantenimiento y la relocalizacin de reas de trabajo. El diseador tambin debe considerar incorporar otros sistemas de informacin del edificio (por ej. televisin por cable, control ambiental, seguridad, audio, alarmas y sonido) al seleccionar y disear el cableado horizontal.

Topologa: la norma EIA/TIA 568A hace las siguientes recomendaciones en cuanto a la topologa del cableado horizontal: El cableado horizontal debe seguir una topologa estrella. Cada toma/conector de telecomunicaciones del rea de trabajo debe conectarse a una interconexin en el cuarto de telecomunicaciones.

Distancias: sin importar el medio fsico, la distancia horizontal mxima no debe exceder 90 m. La distancia se mide desde la terminacin mecnica del medio en la interconexin horizontal en el cuarto de telecomunicaciones hasta la toma/conector de telecomunicaciones en el rea de trabajo. Adems se recomiendan las siguientes distancias: se separan 10 m para los cables del rea de trabajo y los cables del cuarto de telecomunicaciones (cordones de parcheo, jumpers y cables de equipo).

Medios reconocidos: se reconocen tres tipos de cables para el sistema de cableado horizontal: Cables de par trenzado sin blindar (UTP) de 100 ohm y cuatro pares. Cables de par trenzado blindados (STP) de 150 ohm y cuatro pares . Cables de fibra ptica multimodo de 62.5/125 um y dos fibras.

Cableado vertical, troncal o backboneEl propsito del cableado del backbone es proporcionar interconexiones entre cuartos de entrada de servicios de edificio, cuartos de equipo y cuartos de telecomunicaciones. El cableado del backbone incluye la conexin vertical entre pisos en edificios de varios pisos. El cableado del backbone incluye medios de transmisin (cable), puntos principales e intermedios de conexin cruzada y terminaciones mecnicas. El cableado vertical realiza la interconexin entre los diferentes gabinetes de telecomunicaciones y entre estos y la sala de equipamiento. En este componente del sistema de cableado ya no resulta econmico mantener la estructura general utilizada en el cableado horizontal, sino que es conveniente realizar instalaciones independientes para la telefona y datos. Esto se ve reforzado por el hecho de que, si fuera necesario sustituir el backbone, ello se realiza con un coste relativamente bajo, y causando muy pocas molestias a los ocupantes del edificio. El backbone telefnico se realiza habitualmente con cable telefnico multipar. Para definir el backbone de datos es necesario tener en cuenta cul ser la disposicin fsica del equipamiento. Normalmente, el tendido fsico del backbone se realiza en forma de estrella, es decir, se interconectan los gabinetes con uno que se define como centro de la estrella, en donde se ubica el equipamiento electrnico ms complejo.El backbone de datos se puede implementar con cables UTP o con fibra ptica. En el caso de decidir utilizar UTP, el mismo ser de categora 5 y se dispondr un nmero de cables desde cada gabinete al gabinete seleccionado como centro de estrella.Actualmente, la diferencia de coste provocada por la utilizacin de fibra ptica se ve compensada por la mayor flexibilidad y posibilidad de crecimiento que brinda esta tecnologa. Se construye el backbone llevando un cable de fibra desde cada gabinete al gabinete centro de la estrella. Si bien para una configuracin mnima Ethernet basta con utilizar cable de 2 fibras, resulta conveniente utilizar cable con mayor cantidad de fibra (6 a 12) ya que la diferencia de coste no es importante y se posibilita por una parte disponer de conductores de reserva para el caso de falla de algunos, y por otra parte, la utilizacin en el futuro de otras topologas que requieren ms conductores, como FDDI o sistemas resistentes a fallas. La norma EIA/TIA 568 prev la ubicacin de la transmisin de cableado vertical a horizontal, y la ubicacin de los dispositivos necesarios para lograrla, en habitaciones independientes con puerta destinada a tal fin, ubicadas por lo menos una por piso, denominadas armarios de telecomunicaciones. Se utilizan habitualmente gabinetes estndar de 19 pulgadas de ancho, con puertas, de aproximadamente 50 cm de profundidad y de una altura entre 1.5 y 2 metros. En dichos gabinetes se dispone generalmente de las siguientes secciones: Acometida de los puestos de trabajo: 2 cables UTP llegan desde cada puesto de trabajo. Acometida del backbone telefnico: cable multipar que puede determinar en regletas de conexin o en patchpanels. Acometida del backbone de datos: cables de fibra ptica que se llevan a una bandeja de conexin adecuada. Electrnica de la red de datos: Hubs, Switches, Bridges y otros dispositivos necesarios. Alimentacin elctrica para dichos dispositivos. Iluminacin interna para facilitar la realizacin de trabajos en el gabinete. Ventilacin a fin de mantener la temperatura interna dentro de lmites aceptables.

Cuarto de entrada de serviciosConsiste en cables, accesorios de conexin, dispositivos de proteccin, y dems equipo necesario para conectar el edificio a servicios externos. Puede contener el punto de demarcacin. Ofrecen proteccin elctrica establecida por cdigos elctricos aplicables. Deben ser diseadas de acuerdo a la norma TIA/EIA-569-A. Los requerimientos de instalacin son: Precauciones en el manejo del cable Evitar tensiones en el cable Los cables no deben enrutarse en grupos muy apretados Utilizar rutas de cable y accesorios apropiados 100 ohmsUTP y ScTP No giros con un angulo mayor a 90 grados

Sistema de puesta a tierraEl sistema de puesta a tierra y puenteo establecido en estndar ANSI/TIA/EIA-607 es un componente importante de cualquier sistema de cableado estructurado moderno. El gabinete deber disponer de una toma de tierra, conectada a la tierra general de la instalacin elctrica, para efectuar las conexiones de todo equipamiento. El conducto de tierra no siempre se halla indicado en planos y puede ser nico para ramales o circuitos que pasen por las mismas cajas de pase, conductos bandejas. Los cables de tierra de seguridad sern puestos a tierra en el subsuelo.

AtenuacinLas seales de transmisin a travs de largas distancias estn sujetas a distorsin que es una prdida de fuerza o amplitud de la seal. La atenuacin es la razn principal de que el largo de las redes tenga varias restricciones. Si la seal se hace muy dbil, el equipo receptor no interceptar bien o no reconocer esta informacin. Esto causa errores, bajo desempeo al tener que retransmitir la seal. Se usan repetidores o amplificadores para extender las distancias de la red ms all de las limitaciones del cable. La atenuacin se mide con aparatos que inyectan una seal de prueba en un extremo del cable y la miden en el otro extremo.[editar]CapacitanciaLacapacitanciapuede distorsionar la seal en el cable, entre ms largo sea el cable, y ms delgado el espesor del aislante, mayor es la capacitancia, lo que resulta en distorsin. La capacitancia es la unidad de medida de la energa almacenada en un cable. Los probadores de cable pueden medir la capacitancia de este par para determinar si el cable ha sido roscado o estirado. La capacitancia del cable par trenzado en las redes est entre 17 y 20 pF.

Velocidad segn la categora de la red categora 1: se utiliza para comunicaciones telefnicas y no es adecuado para la transmisin de datos ya que sus velocidades no alcanzan los 512Kbps. categora 2: puede transmitir datos a velocidades de hasta 4 Mbps. categora 3: se utiliza en redes 10BaseT y puede transmitir datos a velocidades de hasta 10 Mbps. categora 4: se utiliza en redes Token Ring y puede transmitir datos a velocidades de hasta 16 Mbps. categora 5: puede transmitir datos a velocidades de hasta 100 Mbps. categora 6: Redes de alta velocidad hasta 1Gbps.

Impedancia y distorsin por retardadoLas lneas de transmisin tendrn en alguna porcin ruido de fondo, generado por fuentes externas, el transmisor o las lneas adyacentes. Este ruido se combina con la seal transmitida. La distorsin resultante puede ser menor, pero la atenuacin puede provocar que la seal digital descienda al nivel de la seal de ruido. El nivel de la seal digital es mayor que el nivel de la seal de ruido, pero se acerca al nivel de la seal de ruido a medida que se acerca al receptor. Una seal formada por varias frecuencias es propensa a la distorsin por retardo causada por laimpedancia, la cual es la resistencia al cambio de las diferentes frecuencias. Esta puede provocar que los diferentes componentes de frecuencia que contienen las seales lleguen fuera de tiempo al receptor. Si la frecuencia se incrementa, el efecto empeora y el receptor estar imposibilitado de interpretar las seales correctamente. Este problema puede resolverse disminuyendo el largo del cable. Ntese que la medicin de la impedancia nos sirve para detectar roturas del cable o falta de conexiones. El cable debe tener una impedancia de 100 ohm en la frecuencia usada para transmitir datos. Es importante mantener un nivel de seal sobre el nivel de ruido. La mayor fuente de ruido en un cable par trenzado con varios alambres es la interferencia. La interferencia es una ruptura de los cables adyacentes y no es un problema tpico de los cables. El ruido ambiental en los circuitos digitales es provocado por las lmparas fluorescentes, motores, hornos de microondas y equipos de oficina como computadoras, fax, telfonos y copiadoras. Para medir la interferencia se inyecta una seal de valor conocido en un extremo y se mide la interferencia en los cables vecinos TIA-526-7 Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant OFSTP-7 - (February 2002) TIA-526-14-A Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant OFSTP-14 - (August 1998) ANSI/TIA/EIA-568-B.1 de Alambrado de Telecomunicaciones para Edificios Comerciales, Parte 1: Requerimientos Generales, mayo de 2001. Adenda ANSI/TIA/EIA-568-B.1-1-2001, Adenda 1, Radio de Curvatura Mnimo para Cables de 4 Pares UTP y STP, julio de 2001. TIA/EIA-568-B.1-2 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 2 Grounding and Bonding Requirements for Screened Balanced Twisted-Pair Horizontal Cabling - (February 2003) TIA/EIA-568-B.1-3 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 3 Supportable Distances and Channel Attenuation for Optical Fiber Applications by Fiber Type - (February 2003) TIA/EIA-568-B.1-4 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 4 Recognition of Category 6 and 850 nm Laser Optimized 50/125 m Multimode Optical Fiber Cabling - (February 2003) TIA/EIA-568-B.1-5 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 5 Telecommunications Cabling for Telecommunications Enclosures (March 2004)oexvpemenn la rattamierdsapos TIA/EIA-568-B.1-7 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements Addendum 7 - Guidelines for Maintaining Polarity Using Array Connectors (January 2006) TIA/EIA-568-B.2 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components - (December 2003) TIA/EIA-568-B.2-1 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 1 Transmission Performance Specifications for 4-Pair 100 ohm Category 6 Cabling - (June 2002) TIA/EIA-568-B.2-2 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 2 Revision of Sub-clauses - (December 2001) TIA/EIA-568-B.2-3 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 3 Additional Considerations for Insertion Loss & Return Loss Pass/Fail Determination - (March 2002) TIA/EIA-568-B.2-4 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 4 Solderless Connection Reliability Requirements for Copper Connecting Hardware - (June 2002) TIA/EIA-568-B.2-5 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 5 Corrections to TIA/EIA-568-B.2 (January 2003) TIA/EIA-568-B.2-6 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 6 Category 6 Related Component Test Procedures (December 2003) TIA/EIA-568-B.2-11 Commercial Building Telecommunications Cabling Standard Part 2: Balanced Twisted-Pair Cabling Components Addendum 11 - Specification of 4-Pair UTP and SCTP Cabling (December 2005) TIA/EIA-568-3 Optical Fiber Cabling Components Standard - (April 2002) TIA/EIA-568-3.1 Optical Fiber Cabling Components Standard Addendum 1 Additional Transmission Performance Specifications for 50/125 m Optical Fiber Cables (April 2002) TIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces - (October 2004) TIA-598-C OpticalFiber Cable Color Coding - (January 2005) TIA/EIA-606-A Administration Standard for Commercial Telecommunications Infrastructure - (May 2002) J-STD-607-A Commercial Building Grounding (Earthing) and Bonding Requirements for Telecommunications - (October 2002) TIA-758-A Customer-owned Outside Plant Telecommunications Infrastructure Standard August 2004

2. CONEXIONADOSistema de telefona.- Para esto nicamente tendremos en cuenta que el telfono utiliza dos hilos de lnea coincidentes con el par 1 de P.D.S., y prcticamente puede convivir con casi cualquier tipo de redes.

Redes locales.- Tenemos bsicamente tres tipos de topologa de red, que son: en estrella, en BUS, en Anillo, o bien alguna combinacin de alguna de ellas. En los ltimos aos estamos asistiendo a un auge en el montaje de redes locales, con todas las ventajas que ello conlleva. Los concentradores se suelen instalar en el RAC 19 de la red P.D.S., debido a su pequeo tamao y facilita las conexiones.

INFRAESTRUCTURA NECESARIA PARA LA INSTALACIN.-CANALIZACIONES DE EDIFICIOS.- Para La instalacin de un sistema de cableado estructurado se puede usar toda la canalizacin de comunicaciones del edificio, siempre que permita su instalacin el dimetro de los conductores. Por esto, es preferible realizar el proyecto del edifico teniendo en cuenta las instalaciones que necesitar en cuanto voz, datos, seguridad de robo e incendios, etc.

Las canalizaciones pueden ser del tipo ackermann (bandeja metlica y registros incrustados bajo el cemento del suelo, tubo corrugado, tubo de PVC, falso techo, falso suelo, etc.

Falso suelo.- La instalacin en este medio es una de las ms fciles ya que slo tendremos que levantar las baldosas para realizar el tendido del cable y para sacarlo a la superficie, ser suficiente con un taladro y si el mecanismo va empotrado hay que mecanizar la baldosa. La ventaja es que no tenemos que usar canalizaciones ni escaleras.

Canalizaciones.- Tambin se puede usar la canalizacin existente en el edificio para lo cual tiene que tener suficiente seccin para albergar las mangueras y repartidores de planta. Esas podrn ir a la altura del suelo, por el rodapi, o por las paredes.

Falso techo.-Para instalaciones de este tipo no es necesario instalar prcticamente ningn elemento adicional, salvo en algunos casos que no tengamos las suficientes verticales dentro de la sala para acceder a algunos lugares, pudindose instalar columnas metlicas para descender hasta el puesto de trabajo. Este tipo de columna es aluminio prefabricado y viene con unas guas para su sujecin de mecanismos pero tendremos que mecanizarla (hacer los taladros o ranuras necesarias) para poder instalar los mecanismos.

Sala de equipos.- En la sala de equipos, donde se encuentra las centrales de abonados as como servidores, se ubicarn todos los elementos necesarios distribuidos sobre una pared, o preferiblemente en un armario o armarios de 19. Se podrn aadir elementos que mejoren el servicio como SAIs, etc.

Repartidores de planta.- Para ubicar en las distintas planta las regletas de parcheado, se pueden usar cajas metlicas de 19 de superficie o empotradas en la pared. Si la planta es demasiado grande, se pueden colocar concentradores.

3. DISPOSITIVOS COMPONENTES Y EQUIPOS DEL CABLEADO ESTRUCTURADO

a. COMPONENTES

KEYSTONE:Se trata de un dispositivo modular de conexin mono lnea, hembra, apto para conectar plug RJ45, que permite su insercin en rosetas yfrentes de patchpanels especiales mediante un sistema de encastre.Permite la colocacin de la cantidad exacta deconexionesnecesarias.

ROSETA P/KEYSTONE:Se trata de una pieza plstica de soporte que se amura a la pared y permite encastrar hasta 2 keystone, formando una roseta de hasta 2bocas. No incluye en keystone que se compra por separado.

FRENTE PARA KEYSTONE o FACEPLATE:Se trata de una pieza plstica plana de soporte que es tapa de una cajaestandard de electricidad embutida de 5x10 cm y permite encastrarhasta 2 keystone, formando un conjunto de conexin de hasta 2bocas. No incluye los keystone que se compran por separado. Laboca que quede libre en caso que se desee colocar un solo keystonese obtura con un inserto ciego que tambin se provee por separado.

ROSETAS INTEGRADAS:Usualmente de 2 bocas, aunque existe tambin la versin reducidade 1 boca. Posee un circuito impreso que soporta conectores RJ45 yconectores IDC (InsulationDesplacementConnector) de tipo 110para conectar los cables UTP slidos con la herramienta de impactoSe proveen usualmente con almohadilla autoadhesiva para fijar a lapared y/o perforacin para tornillo. Codigo Discar: CAT5DRJ45

CABLE UTP SOLIDO:El cable UTP (UnshieldedTwistedPair) posee 4 pares bien trenzados entre si (paso muchomstorsionado que el Vaina Gris de la norma ENTeL 755), sin foil de aluminio de blindaje,envuelto dentro de una cubierta de PVC.Existen tipos especiales (mucho ms caros) realizados en materiales especiales parainstalaciones que exigen normas estrictas de seguridad ante incendio.Se presenta en cajas de 1000 pies (305 mts) para su fcil manipulacin, no se enrosca, y vienemarcado con nmeros que representan la distancia en pies de cada tramo en forma correlativa,con lo que se puede saber la longitud utilizada y la distancia que an queda disponible en lacaja con solo registrar estos nmeros y realizar una simple resta. Cdigo Discar: CAT5CS4P

PATCH PANEL:Estn formados por un soporte, usualmentemetlico y de medidas compatibles con rack de19", que sostiene placas de circuito impresosobre la que se montan: de un lado los Conectores RJ45 y del otro los conectores IDCpara block tipo 110.Se proveen en capacidades de 12 a 96 puertos (mltiplos de 12) y se pueden apilar para formarcapacidades mayores. Cdigo Discar: CAT5PPxxP

PATCHCORD:Estn construidos con cable UTP de 4 pares flexibleterminado en un plug 8P8C en cada punta de modo depermitir la conexin de los 4 pares en un conector RJ45.A menudo se proveen de distintos colores y con undispositivo plstico que impide que se curven en la zonadonde el cable se aplana al acometer al plug.Es muy importante utilizar PC certificados puesto que elhacerlos en obra no garantiza en modo alguno lacertificacin a Nivel 5. Cdigos Discar: CAT5xM(color)

PLUG 8P8C:Plug de 8 contactos, similar al plug americano RJ11 utilizado en telefona,pero de ms capacidad. . Posee contactos baados en oro.Cdigo Discar: CAT5RJ45

CABLE UTP FLEXIBLE:

Igual al slido, pero sus hilos interiores estn constituidos por cables flexibles en lugar dealambres. Cdigo Discar: CAT5CF4P

b. HERRAMIENTAS

HERRAMIENTA DE IMPACTO:

Es la misma que se utiliza con block de tipo 110 de la ATT.Posee un resorte que se puede graduar para dar distintaspresiones de trabajo y sus puntas pueden ser cambiadas parapermitir la conexin de otros blocks, tal como los 88 y S66(Krone).En el caso del block 110, la herramienta es de dobleaccin: inserta y corta el cable. Codigo Discar:CAT5HII

HERRAMIENTA DE CRIMPEAR:Es muy similar a la crimpeadora de los plugs americanosRJ11 pero permite plugs de mayor tamao (8posiciones). Al igual que ella permite: cortar el cable,pelarlo y apretar el conector para fijar los hilos flexiblesdel cable a los contactos.Cdigo Discar: CAT5PCRJ45.

CORTADOR Y PELADOR DE CABLES:Permite agilizar notablemente la tarea de pelado devainas de los cables UTP, tanto slidos como flexibles,as como el emparejado de los pares internos del mismo.No produce marcado de los cables, como es habitualcuando se utiliza el alicate o pinza de corte normal.Cdigo Discar: CAT5CUT

PROBADOR RAPIDO DE CABLEADO:Ideal para controlar los cableados (no para certificar) porparte del tcnico instalador. De bajo costo y fcilmanejo.Permite detectar fcilmente: cables cortados o encortocircuito, cables corridos de posicin, piernasinvertidas, etc.Ademas viene provisto de accesorios para controlarcable coaxial (BNC) y PatchCords (RJ45)Codigo Discar: CAT5TEST

c. COMPONENTES INFORMATICOS ASOCIADOS

PLACAS DE RED:Se colocan en cada PC, son placas internas que toman su alimentacin de la misma MotherBoard de la PC. Las placas para 10 BaseT, que es la red mas difundida hoy con el cableadoestructurado, soporta 10 o 100 Mbit/seg. y es exactamente igual a las placas de salida coaxialpero poseen un conector RJ45. Muchos fabricantes proveen placas compatibles con coaxial yRJ45 al mismo tiempo.Existen diversos tipos en funcin de su interface con la PC (bus ISA, PCI, etc).HUB's:Es un equipo electrnico activo que sirve de concentrador y sincronizador de los datos quetransitan entre las distintas placas de red de los puestos de trabajo y el backbone. Siempre seconectan a energa (220v/110v) y tienen entradas con RJ45 como si fuese una patchera (8 a 24puertos tpicamente) y una salida que puede tener varios conectores en paralelo: RJ45, Coaxial(BNC), F.O. (ST) y AUI, este ltimo es el ms comn, pues permite conectar un "mediaadapter" dndole alimentacin.Los modelos "stackables" permiten apilarse y ampliar el nmero de entradas sin incrementarla cada de seal.Se pueden conectar un mximo de 4 HUB's en serie para no producir excesiva atenuacin a laseal, lo cual es muchisimo para las obras que trabajaremos. Tpicamente va uno por cadapiso (armario de piso). Los Servers se conectan a su entrada como si fueran una terminal ms.Existen modelos llamados "Inteligentes" que permiten administrar la red y sacar de serviciouna terminal que este fallando desde un puesto de mantenimiento remoto. Da informacin detrfico avanzada, errores, etc.Es importante ver la velocidad del HUB, ya que si el mismo soporta 10 Mbit, solo servir parala red 10 BaseT actual y habr que cambiarlo por uno ms veloz cuando se pase a una red dems velocidad.

REPETIDOR:Permiten ampliar la distancia a que se conecta un terminal determinado (ms all de los 90mts en el caso de cable UTP), funciona como un amplificador de seal.

MEDIA ADAPTERS:Son dispositivos electrnicos que permiten conectar medios de transmisin (cables, FO,coaxial)distintos de los originalmente previstos en el dispositivo al que se conectan. Generalmente seconectan a puerto de tipo AUI de las placas de red o de los HUB para conectar Fibras pticas,cables Coaxiles, cables Thin-coax, etc.

SERVER:Es el nombre dado a la/las computadoras principales de la red, donde se guarda la informacinvaliosa y que realizan el procesamiento centralizado de informacin de la empresa. A los finesdel cableado estructurado, se comporta como una terminal mas, conectndose a cualquierboca.

BRIDGE:Son equipos electrnicos sofisticados y costosos que permiten enlazar redes entre s. Amenudo realizan adaptaciones de protocolo, permitiendo inter-conectar redes de distintastecnologas y fabricantes.

ROUTER:Son dispositivos electrnicos complejos que permiten manejar comunicaciones entre redesque se encuentran a gran distancia, utilizando vnculos provistos por las empresas prestatariasdel servicio telefnico (lneas Punto a punto), lneas de datos (Arpac), enlaces va satlite, etc.Poseen avanzadas funciones de negociacin del enlace y conversin de protocolos deTransmisin. Se utilizan por lo general en empresas que manejan muchas sucursales, talesComo Bancos, etc. Estn relacionados con sistemas bajo Unix y TCP-IP.

4. ORGANISMOS Y NORMASANSI: American National Standards Institute:Organizacin Privada sin fines de lucro fundada en 1918, la cual administra y coordina el sistema de estandarizacin voluntaria del sector privado de los Estados Unidos.EIA: ElectronicsIndustryAssociation:Fundada en 1924. Desarrolla normas y publicaciones sobre las principales reas tcnicas: los componentes electrnicos, electrnica del consumidor, informacin electrnica, y telecomunicaciones.TIA: TelecommunicationsIndustryAssociation:Fundada en 1985 despus del rompimiento del monopolio de AT&T. Desarrolla normas de cableado industrial voluntario para muchos productos de las telecomunicaciones y tiene ms de 70 normas preestablecidas.ISO: InternationalStandardsOrganization:Organizacin no gubernamental creada en 1947 a nivel Mundial, de cuerpos de normas nacionales, con ms de 140 pases.IEEE: Instituto de Ingenieros Elctricos y de Electrnica:Principalmente responsable por las especificaciones de redes de rea local como 802.3 Ethernet,802.5TokenRing, ATM y las normas de GigabitEthernet

Normas:ANSI/TIA/EIA-568-BCableado de Telecomunicaciones en Edificios Comerciales. (Cmo instalar el Cableado)TIA/EIA 568-B1 Requerimientos generalesTIA/EIA 568-B2 Componentes de cableado mediante par trenzado balanceadoTIA/EIA 568-B3 Componentes de cableado, Fibra pticaANSI/TIA/EIA-569-ANormas de Recorridos y Espacios de Telecomunicaciones en Edificios Comerciales (Cmo enrutarel cableado)ANSI/TIA/EIA-570-ANormas de Infraestructura Residencial de TelecomunicacionesANSI/TIA/EIA-606-ANormas de Administracin de Infraestructura de Telecomunicaciones en Edificios ComercialesANSI/TIA/EIA-607Requerimientos para instalaciones de sistemas de puesta a tierra de Telecomunicaciones en Edificios Comerciales.ANSI/TIA/EIA-758Norma Cliente-Propietario de cableado de Planta Externa de Telecomunicaciones.