Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

12
CONEXION DE CABLEADO EN BBU 6101 REALICE TODAS LAS CONEXIONES EN LA BBU ANTES DE INSTALAR LA RBS ESTO HARA EL TRABAJO MAS SENCILLO

description

RBS 6601

Transcript of Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

Page 1: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CABLEADO EN BBU 6101REALICE TODAS LAS CONEXIONES EN LA BBU ANTES DE INSTALAR LA RBS ESTO HARA EL TRABAJO MAS SENCILLO

Page 2: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CCU

QUITE EL TORNILLO QUE SUJETA LA CCU RETIRE LA CCU

Page 3: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CCU

DESCONECTE EL CABLE QUE CONECTA LA CCU

Page 4: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CCU

TENGA A MANO EL CABLE DE CONEXION DE CLU

Page 5: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CCUCABLE GRIS +

CABLE NEGRO -

EL EXTREMO CON CONECTORDEBERA IR CONECTADO A UN PUERTO DE LA PDU

Page 6: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE CCU

VUELVA A CONECTAR EL CCU INSERTE LA CCU Y PONGALE SU TORNILLO

SALIDA DEL CABLE DC DE CLU

ENRUTE EL CABLE HASTA LA PDU

Page 7: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE ALAMAS BBU

CONECTE EL CABLE DE ALARMA AL CCUEN EL GABINETE RBS6101 CONECTE LA MALLA DE TIERRA

OVP ALARM

CONECTE LOS PARES AL OVPBLANCO AZUL-AZULBLANCO NARANJA-NARANJABLANCO VERDE-VERDEBLANCO CAFÉ-CAFE

SALIDA DEL CABLE DE ALARMA

Page 8: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DC DE CABLES DE BATERIAS EN DC FILTER

CONECTE EL CABLE 0V EN INPUT 1 (RETURN 0V)

CONECTE EL CABLE -48V EN INPUT 1 (-48)

Page 9: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DEL SENSOR DE TEMPERATURA DE BATERIAS

CONECTE EL SENSOR DE TEMPERATURA DE BATERIAS CON EL CONECTOR DB9 POR LA PARTE DE ABAJO DEL DF FILTER

SENSOR DE TEMP DEBATERIA EN LA SEGUNDABATERIA LADO DERECHO

Page 10: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXION DE DC EN BBU6101

CABLE -48V QUE VIENE DEL DC FILTERCABLE +0V QUE VIENE DEL DC FILTER

TERMOCONTRAIBLE NEGRO -48V AZUL +0V

Page 11: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]

CONEXIONES EN BBU

REALICE TODAS LAS CONEXIONES EN LA BBU ANTES DE INSTALAR LA RBS ESTO HARA EL TRABAJO MAS SENCILLO

DC FILTER A DC BAT

DC CLU (CCU)

SENSOR DE BATERIAS

Page 12: Bbu 6601 Guia Rapida de Conexion [Read-Only] [Compatibility Mode]