    P l e a s e Read

    INFORMATION CONCERNING NEW FEATURES

    Controls with microprocessor part number N7185V3 or higher contain the following new features. These controlscan be identified via the downloader as Rev. 06.

    1. This control complies with National Fire Protection Association (NFPA) requirements for temporal pulse sounding of fire notificationappliances. Fire alarms now sound as interrupted pulses consisting of three pulses and a brief pause (i.e. ring, ring, ring, pause -ring, ring, ring, pause, etc.)

    2. Capability has been added for the control to call a pager on the secondary telephone number. This can only be used if the primaryreporting format is Ademco Contact ID. The following entries have been added to program field *49 (Split/Dual Reporting) for thepurpose of paging messages:

    Primary Secondary (Paging number)

    6 = All reports except Open/Close Alarms/ Open/Close, Troubles7 = All reports Alarms, Troubles8 = All reports Alarms, Open/Close, Troubles

    Touch-tone codes sent to the pager are:1911 = Alarm1001 = Open1002 = Close1811 = Trouble

    No restore reports are sent to the pager.

    3. Three additional user codes have been added (identified as Users 5, 6, and 7).

    4. Duress is now User 8 (no longer User code + 1).

    5. AC Loss report is now sent at a random time delay up to 1 hour. If AC is restored before the report goes out, no report will be sent.

    6. Telephone number entries can now contain *, #, and a 2-second pause.Enter # + 11 for "*"Enter # + 12 for "#"Enter # + 13 for 2-sec. pause

    7. Audible Exit Warning option has been added (field *27: 0 = no; 1 = yes [default = 1]). If enabled, beeping will occur during exit timeand will change from slow to rapid beeping during last 5 seconds of exit delay.

    8. Master code is now able to change itself in normal operating mode. To change, enter:[Master code] + [8] + [1] + [new Master code] + [new Master code] again.

    9. New Telco Hand-off feature allows the technician at the site to call the downloading facility from the control panel phone line,initiate a site download (Master Code + # +1), and the control will immediately be on-line with the modem at the downloadingfacility.

    10. If all power is lost at the control, upon power up, the armed status will be the same as it was before the power loss. Bypasses,however, are not retained.

    11. The control checks for the physical battery connection every two minutes. If connection is lost, a visual and audible trouble isindicated, and a communicator report will be sent (if programmed). The actual condition of the battery is still checked once everyfour hours. To clear the low battery message after the low battery condition is restored, enter Test mode: [User code] + [5];otherwise it will clear itself the next time the system checks the battery's condition.

  • 8/10/2019 4110DL Instalacion

    3/16

  • 8/10/2019 4110DL Instalacion

    4/16

    4

    TABLE OF CONTENTS

    RECOMMENDATIONS FOR PROPER PROTECTION .............................5

    Section 1. GENERAL DESCRIPTION................................................................ .........6FEATURES ..........................................................................................6SPECIFICATIONS ...............................................................................6COMPATIBLE DEVICES ................................................................ .....6ZONE RESPONSE TYPE CHARACTERISTICS .................................7WIRING GUIDELINES .........................................................................7

    Section 2. SYSTEM INSTALLATION AND WIRING ..................................................8

    Section 3. PROGRAMMING THE SYSTEM................................................................ 9THE MECHANICS OF PROGRAMMING ............................................9

    Entering Program Mode.................................................................9Programming a Data Field .............................................................9Reviewing a Data Field ..................................................................9Erasing an Entry in a Data Field ....................................................9Downloading ..................................................................................9Clearing All Data Fields .................................................................9Exiting Program Mode ...................................................................9

    Section 4. SYSTEM OPERATION...............................................................................10USER ACCESS CODES......................................................................10

    Adding a Secondary User Code ....................................................10Deleting a Secondary User Code ..................................................10

    KEYPAD FUNCTIONS.........................................................................10System Commands .......................................................................10Panic Keys.....................................................................................10Keyswitch LED Indications ............................................................10Keyswitch Operation ...................................................................... 10

    Section 5. TESTING THE SYSTEM............................................................................11

    REGULATORY AGENCY STATEMENTS.................................................12

    DOC STATEMENT................................ ..................................................... 13

    THE LIMITATIONS OF THIS ALARM SYSTEM .......................................14

    SUMMARY OF CONNECTIONS DIAGRAM ............ INSIDE BACK COVER

    ADEMCO LIMITED WARRANTY .......................................... BACK COVER

  • 8/10/2019 4110DL Instalacion

    5/16

    5

    RECOMMENDATIONS FOR PROPER PROTECTION

    The Following Recommendations For The Location Of Fire AndBurglary Detection Devices Help Provide Proper Coverage ForThe Protected Premises.

    Recommendations For Smoke And Heat Detectors

    With regard to th e number a nd pla cement of smoke/heat detectors, w e subscr ibe to therecommendations contained in the National Fire Protection Association's (NFPA) Standard #72

    noted below.Early warning fire detection is best achieved by the installat ion of fire detection equipmentin all rooms and areas of the household as follows: For minimum protection a smoke detectorshould be installed outside of each separa te sleeping a rea, a nd on each a ddit ional floor of amulti-floor family living unit , including basements. The installat ion of smoke detectors in

    kitchens, attics (finished or unfinished), or in garages is not normally recommended.

    For ad dit ional protection th e NFP A recommends t ha t you insta ll h eat or smoke detectors in

    th e living room, dining r oom, bedroom(s), kitchen, ha llwa y(s), at tic, furna ce room, ut ility a ndstorage rooms, basements and attached garages.

    In addition, we recommend the following:

    Insta l l a smoke detector inside every bedroom where a smoker sleeps.

    Insta l l a smoke detector inside every bedroom w here someone sleeps with the door par t ly

    or completely closed. Smoke could be blocked by the closed door. Also, an alarm in thehallway outside may not wake up the sleeper if the door is closed.

    Insta l l a smoke detector inside bedrooms wh ere electr ica l appliances (such as por ta bleheaters, air conditioners or humidifiers) are used.

    Insta l l a smoke detector a t both ends of a ha l lwa y i f the hal lway is more than 40 feet (12meters) long.

    Insta l l smoke detectors in any room where an a la rm control is loca ted, or in any roomwhere alarm control connections to an AC source or phone lines are made. If detectors arenot so located, a fire within the room could prevent the control from reporting a fire or anintrusion.

    DINING

    KITCHENBEDROOM

    BEDROOM

    BEDROOM

    BEDROOM

    LIVING ROOM

    BEDROOM

    BDRM

    BDRM

    DINING

    LIVING ROOM

    TV ROOM KITCHEN

    BEDROOM BEDROOMTO

    BR

    LVNG RM

    BASEMENT

    KTCHN

    . CLOSEDDOOR

    GARAGE

    Smoke Detectors for Minimum Protection

    Smoke Detectors for Additional Protection

    Heat-Activated Detectors

    Recommendations For Proper Intrusion Protection

    For proper int rusion covera ge, sensors should be locat ed at every possible point of ent ry t o a home orcommercial premises. This w ould include any skylights tha t m ay be present, a nd t he upper w indowsin a multi-level building.

    In a ddit ion, we recommend tha t ra dio backup be used in a security syst em so tha t a larm s ignals canstill be sent to the alarm monitoring stat ion in the event that the telephone lines are out of order(ala rm signa ls ar e normally sent over the phone lines, if connected to a n a larm monitoring sta t ion).

  • 8/10/2019 4110DL Instalacion

    6/16

    -6-

    Section 1. GENERAL DESCRIPTIONThe 4110DL is a microprocessor-ba sed st a te-of-th e-a rt security controls int ended for w ired a pplica tions. TheControl Panel supports up to 6 hardwired zones and can be programmed either through the keypad orremotely using ADEMCO's V-LINK downloading software.

    FEATURES

    ZonesSupported 6 h a r d w ir e z on es , h a v in g t he fol low i n g

    characteristics:

    EOLR supervision supporting N.O. or N.C.sensors.

    300-500 msec normal response.

    Zone 3 programma ble for Fast Response toopen (10mS ).

    Security Codes 1 ma s t er code f or en t ir e s yst em (u ser 1)

    3 secon da r y us er codes (u sers 2-4)

    Keypad Panic Keys P r ov id es 3 pa n ic k ey fu nct ion s

    Alarm Output

    Provides a 12VDC, 2 AMP output (assumes a fullycharged ba tt ery is connected)

    S t e a d y ou t pu t for B u r g la r y /P a n i c, or pu l si n goutput for Fire

    Ou tpu t is cu rr en t lim it ed

    Communication Formats

    Ademco Low Speed (Standard or Expanded):

    1400Hz ACK /KI SS OFF .

    Sescoa/Radionics (Standard or Expanded):

    2300Hz ACK /KI SS OFF .

    Ademco Express:

    DTMF, 1400/2300Hz ACK, 1400Hz KI SS OFF .

    Ademco Contact ID:

    DTMF 1400/2300Hz ACK , 1400Hz KI SS OFF .

    SPECIFICATIONS

    4110DL CONTROL

    1. Physical:

    12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x76mm)

    2. Electrical:

    VOLTAGE INPUT: 16.5VAC from plug-in 25VAtr a nsfor mer , Ademco No. 1321/TF2 (in U .S.A.),1321CN (in Ca na da )

    RECHARGEABLE BACK-UP BATTERY: 12VDC,4AH (Gel t ype).

    CH ARG ING VOLTAGE : 13.8VDC .

    ALARM S OU NDE R: 12V, 2.0 Amp output

    AUXILIARY POWER OUTPUT: 12VDC, 500mAma x. Interru pts for 4-wire sm oke detector reset.

    MAXIMUM ZONE RESISTANCE: Zones 1-8 =300 ohms excluding E OLR

    ULI n U L i n s t a l l a t i o n s, m a x im u m c u r r en t

    d r a w f r o m t h e A u x i l i a r y Ou t p u t a n d

    t h e A l a r m Ou t p u t c omb i n ed mu st n o t

    exceed 500mA t ota l .

    F U S E : B a t t er y (3A) N o. 90-12

    LINE SEIZE: Double Pole

    REGULATORY INFORMATION

    Ringer Eq uivalence: 0.7B

    FC C Regist ra tion No.: AC 398U-68192-AL-E

    UL File No. S1632, G uide U XOU

    COMPATIBLE DEVICES

    Remote Keypads (up to 4)Model Type

    4127, 6127 Fixed E nglish4137AD, 6137, 6128 Fixed En glish Addressa ble

    5330 (Select for Vist a ) Alpha

    IMPORTANT

    Add r essab l e keypads mu st be used i n

    t h e non -ad d r essab l e mode (Dev i c e

    Add r ess 31 ) , wh i c h i s p r e-set a t t he

    fac t o r y . Do no t set t h ese keypad s toan y oth er ad dr esses.

    Smoke Detectors (4-wire only)

    Model Type1412 Ionization P roducts of Combustion

    Detector

    2412 P hotoelectr ic Sm oke Det ector

    2412TH P hotoelectric Smoke Detector)w/135 F(57 C) Hea t D etector)

    Fire Supervisory ModuleA77-71601 EOL Rela y Module (supervises power for 4wir e fire zone).

    Optional Keyswitch4116 Keysw itch

  • 8/10/2019 4110DL Instalacion

    7/16

    -7-

    ZONE RESPONSE TYPE CHARACTERISTICS

    Zone Response Type Characteristics1 Entry/Exit Burglary P r ov ides exi t del a y t ime w h en p a n el i s a r med in a n y a r min g mode.

    P r ov ides ent r y del a y w h en p a n el i s a r med in Aw a y a n d S t a y modesonly.

    3 Perimeter Burglary P r ov ides a n ins t a n t a l a r m w h en p a n el i s a r med in a n y a r ming mode.

    4 Interior, Follower P r ov ides ex it del a y t ime w h en p a n el is a r med in a n y mode.

    Will on ly prov ide ent ry delay i f an Ent ry/Exi t zone is f au lted fi r st upon

    entry. Otherwise, a larm w ill be instant . B y p a ss ed a u t om a t i ca l ly w h en pa n e l i s a r m ed in t h e S t a y or I n st a n t

    mode.

    5 Trouble by Day/Alarm byNight

    P rov ides a t rouble response i f panel is not a rmed when zone is f au lted .

    P r ov ides a n in st a n t a l a r m i f p a n el is a r med in a n y mode.

    6 24-Hr. Silent Alarm P r o vides a s i len t a l a r m t o C en t ra l S t a t ion w h e t her p a n el is a r med ordisarmed.

    7 24 Hr. Audible Alarm P r ov id es a n a u d ib le a l a r m a t t h e b el l ou t pu t a n d k ey pa d w h et h erpanel is armed or disarmed.

    8 24-Hr. Auxiliary Alarm P r ov id es a n a u dib le a la r m a t t h e k ey pa d on ly . No bell output isprovided.

    9 Fire P r o v ides a f ir e a l a r m w h en z on e i s s h or t ed . C a u s es b el l ou t p ut t opulse.

    P r ov ides a t r ou ble r es pon s e w h en zon e is op en .

    10 Interior w/Delay P r ov id es en t ry a n d ex it d el a y t im es .

    B y p a ss ed a u t om a t i ca l ly w h en pa n e l i s a r m ed in t h e S t a y or I n st a n tmode.

    WIRING GUIDELINES

    Wiring Run Chart For Devices* Drawing Aux Power From

    The Control (12V+ & GND)

    TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRERU N

    Wire Size 50 mA or less 100 mA 300 mA 500 mA

    #22 500 ft (152m) 250 ft (76m) 80 ft (24m) 50 ft (15m)

    #20 750 ft (228.6m) 380 ft (116m) 130 ft (39.6m) 80 ft (24m)#18 1300 ft (396m) 650 ft (198m) 220 ft (67m) 130 ft (39.6m)

    #16 1500 ft (457m) 1000 ft (305m) 330 ft (100.5m) 200 ft (70m)

    * Includes Keypads and a la rm devices requir ing separa te power.

    Example: I f you have tw o motion detectors tha t dra w a tota l of 44 mA, and y ou are using #20 AWGwire, th e dista nce from the control pan el Aux + an d - termin als t o the last device can be upto 750 ft.

    IMPORTANT

    Th e l eng t h o f a l l w i r e r un s f o r k eypads mu st n o t ex ceed 1500 f eet ( 457m )

    wh en un sh i el d ed quad condu c t or

    cab l e i s used (750 feet i f sh i el ded cab l e i s

    used ) . Th i s r e st r i c t i o n i s due t o t he capac i t i v e ef f ec t on t h e da t a l i n e s wh en

    qua d cab l e i s used .

    Transformer Wiring Table

    Distance of Transformer Wire GaugeFrom the Control Panel To Use

    U p t o 50 feet # 20

    50100 feet # 18

    100250 feet # 16

  • 8/10/2019 4110DL Instalacion

    8/16

    -8-

    Section 2.SYSTEMINSTALLATION AND WIRING

    INSTALLING THE SYSTEM

    Refer to the Summary of Connections diagram on the inside back cover of this manual for terminalconnections w hen follow ing t hese procedures.

    1. M ou n t t h e Con t rol Ca b in et .

    2. M ou nt t he P C b oa r d.

    WARNING

    BE SURE TO USE THE P L AST I C MOUN T IN G C L I PS (SUPPL I ED ) TO

    I SOLATE THE C IRCU I T BOARDS FROM THE CAB IN ET . FA I L URE

    TO DO SO MAY R ESU L T I N D AMAGE TO TH E TR ANS FORMER

    AND /OR THE C IRCU IT BOARD S .

    3. I n st a l l Rem ot e K ey pa d s .

    4. I n st a l l Ha r d w ir ed Zon es .

    5. Ins t a l l Sounding Devices.

    UL Use on l y UL L i st ed soun d i n g dev i c es f o r U L i n st a l l a t i o n s .

    6. Ins t a l l the Remote Keyswi t ch .

    7. Connect Telephone Line.

    IMPORTANT

    Ma k e su r e te l eph ones on th e p r em i ses a r e conn ec ted on l y th r ough t he

    a l a r m con t r o l pane l (d i sconn ec t f r om th e i n com i ng phone l i n e a t t h ete l eph one j a ck ) . Th i s i s necessa r y to have t r ue l i ne sei zu r e.

    8. Connect the AC Transformer .

    WARNING

    DO NOT P LUG THE TRANSFORMER I N TO THE AC OUTLET UNT I L

    A L L OTH ER WIR I N G TO THE CONTROL I S COMPLETE .

    9. C on nect t h e B a t t er y.

    IMPORTANT

    Do n o t a t t a c h t h e c on n ec t or c a b l e t o t h e b a t t er y 's t er m i n a l s u n t i l

    a f t e r y ou h a v e p l u g g ed t h e AC t r a n s f or me r i n t o a n u n i n t er r u p t ed 120VAC ou t l e t .

    UL1. I n U L i n st a l l a t i on s, m a x i m um c u r r en t d r a w f r om t h e Au x i l i a r y

    Ou t p u t and t h e A l a r m Ou tpu t comb i n ed m us t no t ex ceed 500mA .

    2. U se a 3 A ba t t er y or l a r g er f or U L i n st a l l a t i o n s.

    11. Con n ect E a r t h G r ou nd .

  • 8/10/2019 4110DL Instalacion

    9/16

    -8-

    Section 3. PROGRAMMING THE SYSTEM

    THE MECHANICS OF PROGRAMMING

    For actua l progra m fields, refer to the programm ing form included at t he center of this ma nua l.

    Entering Program Mode

    Use one of th e following m ethods:

    Pr ess both the [*] and [#] keys a t t he same t ime within 50 seconds a f ter power is appled to the Control .

    or

    Af ter power-up, enter the [Mas ter Code] + 8 + 0 (defau l t Mas ter Code is 4110)

    This method is disabled if you exit the program m ode using *98 instead of *99. See "E xiting P rogramMode" lat er in th is section.

    Once you ha ve entered program m ode, da ta field *20 will be display ed (this is the first field in the system).The system will now accept entries for field *20.

    Programming a Data Field

    Field Number

    20

    P ress [*] plus [Field No.] (e.g., *20), and t hen ma ke the requ ired ent ry. Note the following:

    The keypad beeps three t imes when the da t a f ield has been completely programmed

    The next Field No. is displayed. I f you do not want t o program this f ield, press [*] + the Field No. youwa nt to program.

    I f the number of d ig i t s tha t you need to enter in a da t a f ie ld is less than the maximum digi t s ava i lab le(e.g. , the phone number field), enter t he desired da ta , then press [*] + the next Field No. to beprogrammed.

    I f you t ry to enter a non-exis tent f ie ld , the keypad wi l l d isp lay EE or Entry Error . Sim ply re-enter [*]plus a va lid Field No.

    Reviewing a Data Field

    P ress [#] plus [Field No. ]. Note th e follow ing:

    Da ta wi l l be displayed for tha t f ie ld number , en t ry by ent ry (a beep wi ll be heard between ent r ies andthree beeps aft er the last ).

    N o ch a n ges w il l b e a c cept ed in t h is mode.

    I f you t ry to enter a non-exis tent f ie ld , the keypad wi l l d isp lay EE or Entry Error. Sim ply re-enter [#]plus a va lid field number.

    Erasing an Entry in a Data Field

    Applies only to fields *40-*43, and *94.

    P ress [*] plus F ield No. plus [*].

    Downloading

    *96 resets the Subscriber Account number and CS ID in prepara tion for an initia l down load. If *97 wa s

    enter ed previously, *96 mus t be entered last .

    Clearing All Data Fields

    *97 clears (zeros) all da ta fields. The Mast er Code will now be 0 0 0 0.

    WARNING

    DO NO T P R E S S * 97 I F A N Y P ROGR AMM I N G H A S B E E N DON E

    PREV I OUSLY ; DA TA A L READY PROGRAMMED I N T O TH E SYSTEM W I L L

    BE DELETED .

    Exiting Program Mode

    *98 inhibits re-entry int o the progra mming m ode with th e use of the Ma ster Code.

    *99allows re-entry in to the program m ode using Master Code + 8 + 0.

  • 8/10/2019 4110DL Instalacion

    10/16

    -10-

    Section 4: SYSTEM OPERATION

    USER ACCESS CODES

    Adding a Secondary User Code

    MASTER COD E + [CODE KEY] + US ER # ( 2, 3, OR 4) + DES IRED 4-DIG IT ACCE SS CODE .

    (The system will emit a single beep when a secondary code ha s been successfully ent ered.)

    Deletinga Secondary User Code

    MASTER C ODE + [CODE KEY] + US ER # (2, 3 OR 4)

    N otes:

    Al l Mas ter a nd Secondary secur i t y codes permit a ccess to the sys tem for a rming, d isa rming, etc .

    I f a secondary code is inadver tent ly repea ted for d i f ferent users , the lower user number wi l l t akepriority.

    Opening and closing reports are sent for the Master as No. 1. U ser codes are sent as Numbers 2, 3,an d 4, r espectively.

    KEYPAD FUNCTIONS

    System Commands

    B efore armin g, the system must be in the READY condit ion (a ll zones must be intact) . I f the "NOTREADY" message appears, press the READY [* ] key to display fa ulted zones.

    SUMMARY OF SYSTEM COMMANDS

    MODE HOW TO PERFORM EXIT DELAY ENTRYDELAY PERIMETERARMED

    INTERIOR ARMED

    AWAY Security Code + [2] Yes Yes Yes Yes

    STAY Security Code + [3] Yes Yes Yes No

    INSTANT Security Code + [7] Yes No Yes No

    MAXIMUM Security Code + [4] Yes No Yes Yes

    DISARM Security Code + [1]

    BYPASS Security Code + [6] +

    Zone #(s)

    QUICK BYPASS

    (if enabled)

    Security Code + [6]

    CHIME MODE Security Code + [9]

    (toggles on and off)

    SITE-INITIATEDDOWNLOAD*

    Security Code + [#] + [1]

    * Init ia tes phone call t o the downloading facility .

    Panic Keys

    A panic function is activa ted w hen:

    Both keys of the appropria te key pair are pressed a t the same t ime, or

    The appropria te let tered key is pressed for a t least 2 seconds.

    The panic functions ar e identified by th e system as follows:

    Keys Displayed as Zone Zone Type

    [1] & [*], or [A] 95 24-H r. S ilent

    [*] & [#], or [B ] 7 P rogra mma ble (24-H r.Silent, Audible,Auxiliary, or Fire

    [3] & [#], or [C] 96 24-H r. Audible

    Notes:

    Keys [A], [B ], [C] are not on a ll keypads.

    Key [D], if present, is not active here.

    Keyswitch LED Indications

    RED MEANING

    OFF D IS ARME D & NOT RE ADY

    S LOW FLAS H ARME D RE ADY

    RAP ID FLASH ARMED

    Keyswitch Operation

    To arm AWAY, turn key and release within a 1/2 second.

    To arm STAY, turn an d hold key for longer than 2 seconds.

    To disa rm, turn key and immedia te ly release .

  • 8/10/2019 4110DL Instalacion

    11/16

  • 8/10/2019 4110DL Instalacion

    12/16

    -11-

    REGULATORY AGENCY STATEMENTSUL NOTICE: This is a "Grade A" residential system.

    FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENTThis equipment ha s been tested to FCC requirements an d ha s been found a cceptable for use. The FCC requires thefollowing sta tement for your information:

    This equipment generates a nd uses ra dio frequency energy and if not insta lled an d used properly, that is , in s tr ictaccordance with the manufacturer's instructions, may cause interference to radio and television reception. It has beentype tested a nd found to comply with t he limits for a Cla ss B computing device in accorda nce with th e specifications in

    Pa rt 15 of FCC Rules , which are designed to provide reasonable protect ion a gainst such interference in a resident ia linsta lla t ion. However, there is no guarantee that interference will not occur in a part icular insta lla t ion. I f thisequipment d oes cause interference to ra dio or television reception, w hich can be determ ined by tur ning t he equipmentoff and on, th e user is encoura ged to tr y t o correct t he interference by one or more of the following measur es:

    I f using an indoor an tenna , have a qua l i t y outdoor an tenna ins t a l led .

    Reorient the receiving antenna unt il interference is reduced or eliminated.

    Move the ra dio or television receiver awa y from the receiver/contr ol.

    Move the ant enna leads aw ay from any w ire runs to the receiver/control .

    P lug the receiver/contr ol into a different outlet so tha t it an d the rad io or television receiver are on different branchcircuits.

    I f necessary , the user should consult t he dealer or a n experienced ra dio/televis ion technician for add it iona lsuggestions. The user or mast er ma y find t he following booklet prepared by t he Federa l Communicat ions Commissionhelpful:

    "Interference Handbook"

    This booklet is ava ilable from the U .S. G overnment P rinting Office, Wash ington, DC 20402.Th e user shal l n ot make any changes or m odif i cat ions to the equi pment un less author i zed by th e In stal l at i on

    In struct i ons or User' s M anu al. U nau thori zed changes or modif icat i ons coul d void th e user' s aut hori ty to opera te the

    equipment.

    FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENTThis equipment complies with P ar t 68 of the FC C rules. On the front cover of this equipment is a la bel that conta ins,among other informat ion, the FCC regis tra t ion number a nd ringer equivalence number (REN) for this equipment . I frequested, this in forma tion must be provided to the t elephone company.

    This equipment uses the following jacks: An RJ 31X is used to connect t his equipment to the telephone network.

    The REN is used t o determine the qu an tity of devices which ma y be connected to the t elephone line. Excessive RENson the telephone line ma y result in t he devices not ringing in r esponse to an incoming call. In most, but n ot all a reas,the sum of the RE Ns should not exceed five (5.0). To be certa in of the nu mber of devices tha t m ay be connected to th e

    line, as determined by the tota l RENs, conta ct the telephone company to determine the ma ximum REN for the call ingarea .

    I f this equipment causes harm to the telephone network, the telephone company will not ify you in advance thattemporary discontinuance of service may be required. If advance notice is not practical, the telephone company willnotify th e customer as soon a s possible. Also, you will be advised of your right t o file a complaint w ith t he FCC if youbelieve necessary.

    The telephone compa ny ma y ma ke cha nges in its fa cilit ies, equipment, opera tions, or procedures tha t could affect th eoperation of the equipment. If this happens, the telephone company will provide advance notice in order for you toma ke the necessa ry modificat ions in order to maint ain unint errupted service.

    I f t rouble is experienced w ith th is equipment , please conta ct the ma nufacturer for repair a nd w arra nty informat ion. I fthe trou ble is causing ha rm to the telephone netw ork, the telephone company m ay r equest you remove the equipmentfrom the netw ork until th e problem is resolved.

    There a re no user serv iceab le components in th is product , and a l l necessary repa irs mus t be made by themanufa cturer . Other repair methods may invalidate the F CC registra t ion on th is product .

    This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service issubject to sta te ta riffs.

    This equipment is hea ring-aid compat ible.

    When program ming or ma king test calls to an emergency number, briefly explain to the dispa tcher the rea son for thecall. Perform such a ctivities in the off-peak hours; such as early morning or lat e evening.

  • 8/10/2019 4110DL Instalacion

    13/16

    -13-

    CANADIAN DEPARTMENT OF COMMUNICATIONS(DOC ) STATEM E NT

    NOTICEThe Canadian Department of Communicat ions label ident if ies cert i f ied equipment . This cert i f ica t ion means that theequipment meets certain telecommunications network protective, operational and safety requirements. The Departmentdoes not guar an tee the equipment will operat e to the user's sat isfaction.

    Before installing this equipment, users should ensure that it is permissible to be connected to the facilit ies of the localtelecommun ications compa ny. The equipment m ust a lso be insta lled using a n a cceptable meth od of connection. In somecases, the compa ny's inside wiring a s sociat ed with a single line individual service may be extended by mean s of certifiedconnector assembly (telephone extension cord). The customer should be aw ar e tha t compliance with the a bove conditions

    ma y not prevent degra da tion of service in some situa tions.Repairs to cert i f ied equipment should be made by an authorized Canadian maintenance facil i ty designated by thesupplier . Any repairs or a lterat ions made by the user to this equipment , or equipment malfunct ions , may give thetelecommun ications compan y cause to request the user t o disconnect t he equipment.

    U sers should ensure for th eir own protection th at the electrical ground connections of the power utility , telephone linesand internal metall ic water pipe system, i f present , are connected together. This precaut ion may be part icularlyimporta nt in rural area s .

    Caution: User should not a t tempt to ma ke such connect ions themselves , but should conta ct the a ppropria te electr icinspection aut hority, or electrician, as a ppropriate.

    The Load Number (LN) a ssigned to each t ermina l device denotes th e percenta ge of the tota l load to be connected t o atelephone loop which is used by the device, to prevent overloading. The terminat ion on a loop may consis t of anycombination of devices subject only to the requirement that the total of the Load Numbers of all the devices does notexceed 100.

    AVISL'tiquet te du ministre des Commun ications du Can ad a ident ifie le matriel homologu. Cett e tiqu ette certifie que lema triel est conforme certaines n ormes de protection, d'exploitat ion et de scurit des r seaux de tlcommun ications.Le ministre n'assur e toutefois pas que le mat riel fonctionnera la sa tisfa ction de l'utilisat eur.

    Avan t d'insta ller ce ma triel, l'utilisa teur doit s'assurer q u'il est permis de le raccorder a ux insta llat ions de l'entrepriseloca le de t lcommunica t ions . Le matr ie l do i t ga lement t re ins t a l l en su ivant une mthode accepte deraccordement. Dans certains cas, les fils intrieurs de l'entreprise utiliss pour un service individuel la ligne uniquepeuvent tr e prolongs a u moyen d'un dispositif homologu de ra ccordement (cordon prolongateur tlphonique interne).L'abonne ne d oit pas oublier q u'il est possible que la conformit au x condit ions nonces ci-dessus n 'em pche pas ladgra da tion du service dans certa ines situat ions. Actuellement, les entreprises de tlcommun ications ne permett ent pasque l'on raccorde leur matriel aux prises d'abonns, sauf dans les cas precis prvus par les tarifs particuliers de cesentreprises.

    Les rpara tions du ma triel homologu doivent tre effectues pas un centr e d'entretien can ad ien aut oris dsign par lefournisseur. La compagnie de tlcommunications peut demander l'utilisateur de dbrancher un appareil la suite derpara tions ou de modificat ions effectues par l'utilisateur ou cause de ma uvais fonctionnement.

    P our sa propre protection, l'utilisa teur d oit s'a ssurer q ue tous les fils de mise en t erre de la source d'nergie lectriq ue,des l ignes tlphoniques de rseau de conduites d'eau, s ' i l y en a , soient raccords ensemble. Cet te prcaut ion estpart iculirement important e dans les rgions rura les.

    Avertissement: L'utilisateur n e doit pas tent er de faire ces raccordement s lui-mme; il doit avoir recours un serviced'inspection des in sta llations lectriques, ou un lectricien, selon le ca s.

    L'indice de char ge (IC) ass ign chaque d isposit i f termina l pour viter toute surcharge indiq ue le pourcenta ge de lacharge totale qui peut tre raccord un circuit tlphonique boucl utilis par ce dispositif . La terminaison du circuitboucl peut tre constitue de n'importe q uelle combinaison de dispositifs, pourvu q ue la somme des indices de charge del'ensemble des dispositifs ne dpasse pas 100.

  • 8/10/2019 4110DL Instalacion

    14/16

    -14-

    WARNINGTHE LIMITATIONS OF THIS ALARM SYSTEM

    While this Syst em is an a dva nced design security system, it does not offer guara nteed protection aga inst burgla ry, fire orother emergency. Any a larm system, w hether commercial or residential, is subject to compromise or failure to wa rn for avari ety of reasons. For example:

    Intrusion detectors (e.g., passive infrared detectors), smoke detectors , and ma ny other sensing devices will not w orkwithout power. Ba t tery-operated devices will not w ork without bat teries , with dead bat t eries , or i f the ba t teries arenot put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason,however briefly.

    Signals sent by wireless t ransmit t ers may be blocked or ref lected by metal before they reach the a larm r eceiver. Evenif the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved intothe path.

    A user may not be able to reach a panic or emergency but ton quickly enough.

    While smoke detectors have played a key role in reducing resident ia l f ire deaths in the Unit ed Sta tes , they may notact ivate or provide early w arn ing for a variety of reasons in as m any as 35%of a ll f ires , according to data publishedby the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with thisSyst em may not work are a s follows. Smoke detectors may ha ve been improperly insta lled and posit ioned. Smokedetectors may not sense f ires tha t s ta rt w here smoke cannot reach the detectors , such a s in chimneys , in wa lls , orroofs, or on the other side of closed doors. Smoke detectors also ma y not sense a fire on an other level of a residence orbuilding. A second floor detector, for exam ple, may n ot sense a first floor or basem ent fire. Fina lly, smoke detectorsha ve sensing limitat ions. No smoke detector can sense every kind of fire every time. In genera l, detectors ma y notalways warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escapinggas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson.Depending on th e na ture of th e f ire and /or locat ion of the smoke detectors , the detector , even if i t operat es as

    an ticipated, may not provide sufficient wa rning t o allow a ll occupant s to escape in time to prevent injury or deat h.

    Pa ss ive In f ra red Mot ion Detectors can only detect in t rus ion wi th in the des igned ranges as d iagrammed in theirinsta lla t ion ma nual. P ass ive Infra red D etectors do not provide volumetric ar ea protect ion. They do create mult iplebeams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannotdetect motion or intrusion th at ta kes place behind w alls, ceilings, floors, closed doors, glass part it ions, glass doors, orwindows. Mechanical ta mpering, masking, paint ing or spraying of any ma teria l on the mirrors , windows or any pa rtof the opt ical system ca n reduce their detect ion abili ty . P ass ive Infra red Detectors sense changes in temperat ure;however, as the a mbient temperature of the protected a rea a pproaches the t emperat ure ran ge of 90t o 105F (32t o40C), the detection performa nce can decrease.

    Alarm w arning devices such a s s irens , bells or horns may n ot a lert people or wake up s leepers i f they are locat ed onthe other side of closed or par tly open doors. If w ar ning d evices ar e locat ed on a d ifferent level of the r esidence fromthe bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awakemay not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, orby passing tra ffic. Fin ally, ala rm w ar ning devices, however loud, ma y not wa rn hear ing-impaired people.

    Telephone l ines needed to t ransmit a la rm s igna ls f rom a premises to a cent ra l moni tor ing s t a t ion may be out o fservice or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.

    Even if the system responds to the emergency as intended, however, occupants ma y ha ve insuff icient t ime to protectthemselves from the emergency s ituat ion. In the case of a monitored a larm system, authorit ies may not respondappropriately.

    This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designedto last as long a s 20 year s, the electronic components could fail a t a ny t ime.

    The most common cause of an a larm system not functioning when a n intru sion or fire occurs is inadequa te ma intena nce.This ala rm syst em should be tested w eekly to ma ke sure all sensors an d tra nsmitt ers are w orking properly. The securitykeypad (and r emote keypad) should be tested a s well.

    Wireless t ransmit ters (used in some systems) are designed to provide long bat tery l i fe under normal operat ingconditions. Longevity of batt eries may be a s much a s 4 to 7 year s, depending on th e environment , usage, a nd th e specificwireless device being used. External factors such as humidity, high or low temperatures , as well as large swings intemperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify atrue low bat t ery s ituat ion, thus a llowing t ime to arra nge a cha nge of bat tery to ma inta in protect ion for tha t given point

    within the system.Ins t a l l ing an a la rm sys tem may make the owner e l ig ib le for a lower insurance ra te , bu t an a la rm sys tem is not asubst itute for insurance. Homeowners , property owners and renters should cont inue to act prudent ly in protect ingthemselves and continue to insure their lives and property.

    We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and theirloved ones to learn about t hese developments.