00 Portada cálculos -...

107
Documento 1.2 Cálculos PROYECTO FIN DE CARRERA PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2MW Marzo 2011

Transcript of 00 Portada cálculos -...

Documento 1.2

Cálculos

PROYECTO FIN

DE CARRERA

PLANTA DE GENERACIÓN DE ENERGÍA

ELÉCTRICA A PARTIR DE BIOMASA CON

UNA POTENCIA DE 2MW

Marzo 2011

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

1/106

ÍNDICE ....................................................................................................................................................... 1

1 CÁLCULOS DEL SISTEMA DE OBTENCIÓN DE ENERGÍA ................................................ 3

1.1 CICLO DE RANKINE ...................................................................................................................... 3 1.2 RESULTADOS DEL CÁLCULO TERMODINÁMICO ................................................................................ 5

1.2.1 Balance de materia .......................................................................................... 7 1.2.2 Balance de energía .......................................................................................... 7

1.3 ANÁLISIS DE LOS COMPONENTES DEL CICLO DE VAPOR .................................................................. 7

1.3.1 Caldera ........................................................................................................... 8 1.3.2 Turbina de vapor ............................................................................................. 8 1.3.3 Condensador ................................................................................................... 8 1.3.4 Torres de refrigeración ..................................................................................... 9 1.3.5 Desgasificador ............................................................................................... 10 1.3.6 Bombas......................................................................................................... 10 1.3.7 Alimentación de aire ...................................................................................... 10 1.3.8 Alimentación de combustible .......................................................................... 11 1.3.9 Salida de gases ............................................................................................. 11 1.3.10 Splitter (separador de corrientes) ................................................................... 11

1.4 ANÁLISIS DE LAS CORRIENTES .................................................................................................... 11

1.4.1 Corrientes de aire y gases .............................................................................. 11 1.4.2 Corrientes de agua líquida y vapor .................................................................. 12 1.4.3 Corrientes de combustible .............................................................................. 12

1.5 CANTIDAD DE BIOMASA NECESARIA Y ALMACENAMIENTO DE LA MISMA ......................................... 13

2 CÁLCULOS ESTRUCTURALES ................................................................................................ 15

2.1 NAVE ALMACÉN ......................................................................................................................... 15

2.1.1 Estructura ..................................................................................................... 15 2.1.2 Cimentación .................................................................................................. 32

2.2 NAVE DE PROCESO .................................................................................................................... 42

2.2.1 Estructura ..................................................................................................... 42 2.2.2 Cimentación .................................................................................................. 72

3 CÁLCULO DEL SISTEMA CONTRA INCENDIOS ................................................................. 87

3.1 CARACTERIZACIÓN ..................................................................................................................... 87

3.1.1 Configuración ................................................................................................ 87 3.1.2 Carga de fuego de las áreas de incendio ......................................................... 87

3.2 SECTORIZACIÓN ........................................................................................................................ 99

3.2.1 Sectores de incendio ...................................................................................... 99 3.2.2 Nivel de riesgo del establecimiento ............................................................... 100

3.3 INSTALACIONES NECESARIAS .................................................................................................... 100

3.3.1 Hidrantes exteriores ..................................................................................... 101 3.3.2 Red de bocas de incendio equipadas (BIEs) .................................................. 101 3.3.3 Rociadores automáticos ............................................................................... 101 3.3.4 Columna seca .............................................................................................. 101 3.3.5 Sistema de abastecimiento de agua y grupo de bombeo ................................ 101

Índice

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

2/106

3.3.6 Extintores de incendio .................................................................................. 102 3.3.7 Detectores automáticos................................................................................ 102 3.3.8 Sistemas manuales de alarma de incendios ................................................... 102 3.3.9 Estabilidad al fuego de los elementos constructivos portantes ........................ 102 3.3.10 Evacuación .................................................................................................. 104

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

3/106

1.1 Ciclo de Rankine

El fundamento termodinámico que emplea la planta para la generación del

trabajo, transformable en energía eléctrica por el generador, se basa en el ciclo

termodinámico de Rankine. Dicho ciclo se trata de un ciclo agua-vapor

caracterizado por dos procesos isóbaros y otros dos isentrópicos, como

podemos ver en la siguiente figura:

Fig. 1: Ciclo de Rankine

1

1 Cálculos del sistema de obtención de energía

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

4/106

El anterior se trata del ciclo ideal, es decir, el que seguiría el sistema si los

rendimientos de los todos equipos fuesen del 100% y las pérdidas de calor en

todo el circuito agua-vapor fuesen nulas.

A continuación analizamos los puntos de trabajo representativos del ciclo

real con el que trabajará la planta:

PUNTO 1

Vapor sobrecalentado

T (ºC) 450

P (bar) 40

H (kJ/kg) 3331,01

S (J/kg ºC) 6,9388

PUNTO 2

Vapor húmedo

T (ºC) 45,83

P (bar) 0,1

H (kJ/kg) 2326,69

S (J/kg ºC) 8,1511

PUNTO 3

Líquido saturado

T (ºC) 45,83

P (bar) 0,1

H (kJ/kg) 191,82

S (J/kg ºC) 0,6492

PUNTO 4

Líquido subenfriado

T (ºC) 45,85

P (bar) 1,196

H (kJ/kg) 192,00

S (J/kg ºC) 0,6494

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

5/106

1.2 Resultados del cálculo termodinámico

Para la resolución de todos los cálculos termodinámicos necesarios hemos

empleado el programa informático THERMOFLEX, uno de los subprogramas

perteneciente al grupo THERMOFLOW. En dicho programa hemos modelado el

ciclo de Rankine con todos sus componentes, dando como datos de partida el

rendimiento de todos los equipos, la presión y temperatura de vapor vivo, y el

caudal de vapor necesario para la generación de 2 MWe. A continuación

mostramos el esquema del ciclo Rankine resuelto por el programa:

Fig. 2: Modelado del ciclo con Thermoflex

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

6/106

A continuación mostramos los resultados generales obtenidos con dicho

programa:

PCI PCS

Potencia de entrada neta de combustible (kW) 7235 7796

Tasa bruta de calor (kJ/kWh) 13023

Tasa neta de calor (kJ/kWh) 13841 14915

Eficiencia eléctrica bruta (%) 27,64

Eficiencia eléctrica neta (%) 26,01 24,14

Potencia bruta 2000

Potencia neta 1901,8

Potencia auxiliar total 98,2

• Equipos generadores de energía eléctrica:

Potencia en el eje (kW) Eficiencia (%) Salida (kW)

Turbina de vapor 2083,7

Generador 2083,7 95,98 2000

• Equipos consumidores de energía eléctrica (autoconsumo):

Potencia en el eje (kW) Eficiencia (%) Potencia consumida (kW)

Torres de refrigeración 48,1

Caldera 19,1

Bomba 1 15,8 91,07 17,3

Bomba 2 0,4 98,52 0,4

Condensador 13,4

Total 98,2

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

7/106

1.2.1 Balance de materia

Caudal másico de entrada (kg/s) Caudal másico de salida (kg/s)

Combustible de entrada 0,43

Aire de entrada 2,51

Salida de gases 2,94

TOTAL 2,94 2,94

1.2.2 Balance de energía

Energía suministrada (KW) Energía cedida (KW)

Torres de refrigeración 4.439,00

Combustible de entrada 7.235,00

Salida de gases 539,20

Turbina de vapor 2.087,80

Bomba 1 0,37

Bomba 2 15,31

Caldera 17,32 202,00

TOTAL 7.268,00 7.268,00

1.3 Análisis de los componentes del ciclo de vapor

En este apartado mostramos los resultados obtenidos para cada uno de

los equipos que componen el ciclo agua-vapor de Rankine:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

8/106

1.3.1 Caldera

Nº de

corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Aire de entrada 5 1,013 25 2,51 0

Combustible de entrada 4 1,013 25 0,429 16850,84

Salida de gases 7 1,013 194,51 2,936 183,68

Agua de entrada 13 42,44 100,51 2,24 -2123,08 424,41

Vapor de salida 8 40 450 2,24 783,52 3331,01

• Calor transferido:

Calor cedido en el economizador (kW) 1291,3

Calor cedido en el evaporador (kW) 4029

Calor cedido en el sobrecalentador (kW) 1190,3

Calor total transferido (kW) 6511

Perdidas de calor (kW) 201,4

1.3.2 Turbina de vapor

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 3 40 450 2,079 783,52 3331,01

Agua de salida 6 0,1 45,83 2,079 -220,7 2326,79

1.3.3 Condensador

Nº de corriente

P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

9/106

Vapor de entrada 6 0,1 45,83 2,079 -220,7 2326,79

Agua de salida 10 0,1 45,83 2,079 -2355,67 191,82

Entrada agua refrigeración 1 1,013 29,48 106,615 -2423,8 123,69

Salida agua refrigeración 11 1,013 39,48 106,615 -2382,16 165,32

1.3.4 Torres de refrigeración

Nº de corriente

P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 11 1,013 39,48 106,615 -2382,16 165,32

Agua de salida 1 1,013 29,48 106,615 -2423,8 123,69

Aire de entrada 25 253,253

Aire de salida 25,11 255,073

• Balance de materia en las torres:

Purgas (kg/s) 0,4336

Derivaciones (kg/s) 0,02132

Evaporada (kg/s) 1,82

Entrada desde depósito (kg/s) 2,275

• Consumo de energía eléctrica en las torres:

Potencia consumida (kW)

Bombas 13,38

Ventiladores 34,7

TOTAL 48,08

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

10/106

1.3.5 Desgasificador

Nº de

corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 9 1,196 45,85 2,079 -2355,49 192

Vapor de entrada 12 40 450 0,161 783,52 3331,01

Agua de salida 2 1,196 99,63 2,24 -2129,91 417,58

1.3.6 Bombas

• Bomba de baja presión:

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 10 0,1 45,83 2,079 -2355,67 191,82

Agua de salida 9 1,196 45,85 2,079 -2355,49 192

• Bomba de alta presión:

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 2 1,196 99,63 2,24 -2129,91 417,58

Agua de salida 13 42,44 100,51 2,24 -2123,08 424,41

1.3.7 Alimentación de aire

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)

Aire 5 1,013 25 2,511 0

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

11/106

1.3.8 Alimentación de combustible

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)

Combustible 4 1,013 25 0,492 16850,84

1.3.9 Salida de gases

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg)

Gases 7 1,013 194,51 2,936 183,68

1.3.10 Splitter (separador de corrientes)

Nº de corriente P (bar) T (ºC) M (kg/s) H* (kJ/kg) H (kJ/kg)

Agua de entrada 8 40 450 2,24 783,52 3331,01

Agua de salida 1 3 40 450 2,079 783,52 3331,01

Agua de salida 2 12 40 450 0,161 783,52 3331,01

1.4 Análisis de las corrientes

En este apartado analizamos cada una de las corrientes que forman el

circuito:

1.4.1 Corrientes de aire y gases

Nº de corriente P (bar) T (ºC) H* (kJ/kg) Mgas (kg/s) Mash (kg/s) V (m3/s)

5 1,0132 25 0 2,511 0 2,1

7 1,0132 194,51 183,68 2,936 0,004 3,8

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

12/106

1.4.2 Corrientes de agua líquida y vapor

Nº de corriente P (bar) T (ºC) H* (kJ/kg) H (kJ/kg) M (kg/s) Sup/Sub

(ºC)

1 1,0132 29,48 -2423,8 123,69 106,6 -10,52

2 1,196 99,63 -2129,91 417,58 2,24 -5,09

3 40 450 783,52 3331,01 2,079 199,67

6 0,1 45,83 -220,7 2326,79 2,079 0,8922

8 40 450 783,52 3331,01 2,24 199,67

9 1,196 45,85 -2355,49 192 2,079 -58,87

10 0,1 45,83 -2355,67 191,82 2,079 0

11 1,0132 39,48 -2382,17 165,32 106,6 -60,52

12 40 450 783,52 3331,01 0,161 199,67

13 42,44 100,51 -2123,08 424,41 2,24 -153,35

1.4.3 Corrientes de combustible

Nº de corriente P (bar) T (ºC) H* (kJ/kg) M (kg/s) Cenizas (%) H2O (%)

4 1,0132 25 16850,84 0,429 1,08 5

Composición del combustible de entrada al ciclo:

% en peso de cenizas 1,08

% en peso de humedad 12

% en peso de C 45,41

% en peso de H 5,43

% en peso de O 42,56

% en peso de N 0,45

% en peso de S 0,07

PCI (kJ/kg) 16851

PCS (kJ/kg) 18158

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

13/106

1.5 Cantidad de biomasa necesaria y almacenamiento de la misma

La caldera de biomasa consume 0.429 kg/s de astillas de eucalipto

durante su funcionamiento, por lo que es necesario asegurar el abastecimiento

de la misma para evitar paradas en la producción. La planta estará

funcionando durante 7.500 horas al año, por lo que la demanda anual de

biomasa será:

año

ton

año

kg

h

s

año

h

s

kg115831158300036007500429.0 ==⋅⋅

En cuanto a las necesidades de almacenamiento, los requerimientos que

vamos a imponer al silo principal son que tenga suficiente capacidad para el

almacenamiento de astillas para el funcionamiento ininterrumpido de la planta

durante una semana. Por lo tanto la capacidad del silo principal, considerando

una densidad de la madera astillada de 300 kg/m3, ha de ser:

3

3

865300

3600247429.0m

m

kgh

s

día

hdías

s

kg

=⋅⋅⋅

Finalmente, la nave de almacenamiento debe tener una capacidad

suficiente para almacenar troncos de eucalipto para la producción

ininterrumpida durante una semana. Considerando una densidad de la madera

de 720 kg/m3, tenemos que el volumen de madera necesario es:

3

3

36.360720

3600247429.0m

m

kgh

s

día

hdías

s

kg

=⋅⋅⋅

Suponiendo un factor de apilamiento de los troncos de 0,7 tenemos que el

volumen necesario para el almacenamiento de los troncos es:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

14/106

33 6137.036.360 mm =⋅

Suponiendo una altura de almacenamiento de 2 m, tenemos que la

superficie destinada al almacenamiento de los troncos a de ser:

23

5.3062

613m

m

m =

Puesto que la superficie de la Nave de Almacenamiento es 600 m2,

concluimos que ésta es lo suficientemente grande para cumplir los requisitos de

almacenamiento de troncos.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

15/106

2.1 Nave Almacén

2.1.1 Estructura

La estructura de la Nave Almacén se ha calculado empleando perfiles de

acero laminado S 275 JR. Está formada por 7 pórticos rígidos a un agua de 20

m de luz, con 8 m de altura en los pilares aguas abajo y 10 m en los pilares

aguas arriba, en todos los casos respecto a la solera terminada.

Los pilares irán empotrados en su base a la cimentación mediante placas

de anclaje, con una separación entre pórticos 5 m.

Las correas están formadas por perfiles laminados en caliente IPE 140

separados entre sí 1 m, que reciben la carga de la cubierta.

Fig. 3: Detalle de un pórtico intermedio y las correas

2

2 Cálculos estructurales

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

16/106

La tipología de la estructura se puede ver de una forma más clara en la

siguiente figura, en la que se muestra una representación 3D de la misma:

Fig. 4: Vista 3D de la estructura metálica

• Acciones adoptadas en el cálculo

Todos los valores de las acciones que se han aplicado en el cálculo de

cada uno de los elementos resistentes se ajustan a lo prescrito en la Norma

“CTE DB SE-AE Acciones en la Edificación”, siendo sus valores los siguientes:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

17/106

Acciones Gravitatorias

Concargas Peso Propio

Cubierta de chapa: 15 kg/m²

Estructura: 7.850 kg/m³

Carga Permanente -

Sobrecargas De Uso 25 kg/m2

De Nieve H: 300 m 20 kg/m²

Acciones del Viento Según CTE DB SE-AE

Altura Coronación < 10 m. Situación Expuesta.

Acciones Térmicas No se necesitan juntas de dilatación

Acciones Reológicas

No han sido consideradas por tratarse de una estruc-tura toda ella realizada con materiales metálicos y

ser, por tanto, despreciables los efectos de las mismas, según indica la Norma CTE DB SE-A.

Acciones Sísmicas No han sido consideradas por ser la aceleración

básica menor que la mínima exigida para realizar los cálculos sísmicos según indica el CTE

El acero empleado en la estructura será del tipo S 275 JR con límite

elástico σe = 275 N/mm2, la estructura secundaria (correas) será del tipo S 275

JR con límite elástico σe = 275 N/mm2. La resistencia de cálculo del acero viene

fijada por la expresión: σu = σe / γa, donde γa es el coeficiente de minoración,

con valor 1, pues el acero tendrá el límite elástico mínimo garantizado.

Las constantes elásticas del acero serán las siguientes:

Módulo de elasticidad E = 2100000 kg/cm2

Módulo de elasticidad transversal G = 810000 kg/cm2

Coeficiente de Poisson µ = 0.30

El coeficiente de dilatación térmica del acero para el cálculo de esfuerzos,

tensiones y deformaciones se tomará: αt = 0.000012 m/m°C.

• Métodos de cálculo e hipótesis de carga

El cálculo se ha realizado mediante programa informático comercial

“METAL 3D” de la casa especializada “CYPE INGENIEROS, S.A.”,

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

18/106

comprobándose la estabilidad estática y elástica, las tensiones y las

deformaciones.

Dichos cálculos están basados en las leyes de la mecánica y en la teoría

de la elasticidad, admitiendo, en alguna ocasión y de modo implícito, la

existencia de estados tensionales plásticos locales.

Las hipótesis de carga utilizadas son las establecidas en el CTE DB SE-AE y

las acciones características las prescritas en el CTE DB SE-AE. Las acciones

consideradas en este cálculo han sido las siguientes:

Acciones constantes:

- el peso propio;

- la carga permanente;

Acciones variables:

- las sobrecargas de uso o explotación;

- las acciones de viento;

- la sobrecarga producida por la nieve;

Los coeficientes de ponderación según la hipótesis de carga, la clase de

acción y el efecto favorable o desfavorable de la acción sobre la estabilidad o

las tensiones se dan en el cuadro siguiente:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

19/106

• Resultados en el cálculo de esfuerzos sobre la estructura

Se muestran a continuación los resultados del cálculo sobre la estructura

principal y correas. No se incluyen en estos listados los resultados sobre las

cruces de San Andrés.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

20/106

Resultados de cálculo en pórtico hastial 1.- Barras: Descripción

Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.

(kp) (m³) (m) (m) (m)

53/54 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00

54/56 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

55/56 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 8.38

56/58 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

57/58 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 8.75

58/60 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02

59/60 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 9.25

60/62 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

61/62 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 9.63

62/64 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

63/64 Acero (S275) HE 240 A (HEA) 602.88 0.077 10.00 0.70 1.28 10.00 10.00

2.- Cargas (Barras)

Barras Hipót. Tipo Cargas Dirección

P1 P2 L1 (m) L2 (m) X Y Z

53/54 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

53/54 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

53/54 3 (V 1) Uniforme 0.152 t/m - - - 0.000 1.000 0.000

53/54 3 (V 1) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

53/54 4 (V 2) Uniforme 0.152 t/m - - - 0.000 1.000 0.000

53/54 4 (V 2) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

53/54 5 (V 3) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000

53/54 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000

53/54 6 (V 4) Uniforme 0.076 t/m - - - 0.000 -1.000 0.000

53/54 6 (V 4) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

53/54 7 (V 5) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000

53/54 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

54/56 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

54/56 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

54/56 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

54/56 3 (V 1) Faja 0.120 t/m - 2.010 3.769 0.000 -0.100 0.995

54/56 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995

54/56 4 (V 2) Faja 0.003 t/m - 2.010 3.769 0.000 0.100 -0.995

54/56 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995

54/56 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

54/56 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995

54/56 7 (V 5) Uniforme 0.342 t/m - - - 0.000 -0.100 0.995

54/56 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

54/56 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

54/56 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

55/56 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

55/56 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

55/56 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

21/106

55/56 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000

55/56 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

55/56 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

56/58 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

56/58 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

56/58 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

56/58 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995

56/58 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995

56/58 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

56/58 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995

56/58 7 (V 5) Faja 0.342 t/m - 0.000 1.256 0.000 -0.100 0.995

56/58 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

56/58 7 (V 5) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995

56/58 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

56/58 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

57/58 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

57/58 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

57/58 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

57/58 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000

57/58 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

57/58 7 (V 5) Uniforme 0.273 t/m - - - -1.000 0.000 0.000

58/60 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

58/60 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

58/60 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

58/60 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995

58/60 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995

58/60 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

58/60 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995

58/60 7 (V 5) Uniforme 0.299 t/m - - - 0.000 -0.100 0.995

58/60 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

58/60 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

58/60 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

59/60 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

59/60 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

59/60 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

59/60 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000

59/60 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

59/60 7 (V 5) Uniforme 0.273 t/m - - - -1.000 0.000 0.000

60/62 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

60/62 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

60/62 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

60/62 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995

60/62 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995

60/62 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

60/62 6 (V 4) Uniforme 0.167 t/m - - - 0.000 -0.100 0.995

60/62 7 (V 5) Faja 0.299 t/m - 0.000 2.513 0.000 -0.100 0.995

60/62 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

22/106

60/62 7 (V 5) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995

60/62 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

60/62 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

61/62 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

61/62 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

61/62 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

61/62 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000

61/62 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

61/62 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

62/64 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

62/64 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

62/64 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

62/64 3 (V 1) Uniforme 0.120 t/m - - - 0.000 -0.100 0.995

62/64 4 (V 2) Uniforme 0.003 t/m - - - 0.000 0.100 -0.995

62/64 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

62/64 6 (V 4) Faja 0.167 t/m - 0.000 1.759 0.000 -0.100 0.995

62/64 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995

62/64 7 (V 5) Uniforme 0.351 t/m - - - 0.000 -0.100 0.995

62/64 7 (V 5) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

62/64 8 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

62/64 9 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

63/64 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

63/64 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

63/64 3 (V 1) Uniforme 0.076 t/m - - - 0.000 1.000 0.000

63/64 3 (V 1) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

63/64 4 (V 2) Uniforme 0.076 t/m - - - 0.000 1.000 0.000

63/64 4 (V 2) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

63/64 5 (V 3) Uniforme 0.104 t/m - - - 0.000 1.000 0.000

63/64 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000

63/64 6 (V 4) Uniforme 0.152 t/m - - - 0.000 -1.000 0.000

63/64 6 (V 4) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

63/64 7 (V 5) Uniforme 0.248 t/m - - - 0.000 1.000 0.000

63/64 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos

Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)

DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)

53 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

54 Envolvente (Desplazam.) -0.0176 -0.0277 0.0000 -0.0017 -0.0013 -0.0013

0.0176 0.0186 0.0000 0.0033 0.0001 0.0017

55 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

56 Envolvente (Desplazam.) -0.0306 -0.0277 -0.0001 -0.0010 -0.0037 -0.0014

0.0305 0.0186 0.0000 0.0014 0.0026 0.0013

57 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

23/106

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

58 Envolvente (Desplazam.) -0.0412 -0.0277 -0.0001 -0.0015 -0.0057 -0.0018

0.0411 0.0186 0.0000 0.0019 0.0033 0.0014

59 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

60 Envolvente (Desplazam.) -0.0453 -0.0278 -0.0001 -0.0009 -0.0058 -0.0017

0.0451 0.0186 0.0000 0.0015 0.0032 0.0014

61 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

62 Envolvente (Desplazam.) -0.0383 -0.0278 -0.0001 -0.0009 -0.0037 -0.0017

0.0382 0.0186 0.0000 0.0015 0.0023 0.0012

63 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

64 Envolvente (Desplazam.) -0.0257 -0.0278 -0.0001 -0.0012 -0.0019 -0.0013

0.0256 0.0186 0.0000 0.0031 0.0004 0.0017 4.- Reacciones

Nudos Descripción REACCIONES (EJES GENERALES)

RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)

53 Envolvente (Cim.equil.) -1.2011 -1.4993 -0.5265 -3.8632 -1.7118 -0.0008

1.0275 1.9856 1.5077 3.7367 2.1021 0.0006

53 Envolvente (Cim.tens.terr.) -0.7511 -0.9320 -0.0205 -2.4335 -1.0708 -0.0005

0.6409 1.2489 1.0277 2.3236 1.3102 0.0004

55 Envolvente (Cim.equil.) -2.2464 -0.2738 -1.5184 -1.9010 -6.7868 -0.0009

2.6694 0.4179 2.5817 1.2559 7.5018 0.0008

55 Envolvente (Cim.tens.terr.) -1.4661 -0.1727 -0.5193 -1.1844 -4.4126 -0.0005

1.6093 0.2601 1.7922 0.7902 4.5263 0.0006

57 Envolvente (Cim.equil.) -3.0455 -0.2179 -1.8951 -1.6433 -8.5896 -0.0009

3.2301 0.3333 3.3033 1.0832 9.3926 0.0010

57 Envolvente (Cim.tens.terr.) -2.0046 -0.1338 -0.6569 -1.0372 -5.6594 -0.0005

1.9243 0.2121 2.3030 0.6706 5.5985 0.0007

59 Envolvente (Cim.equil.) -3.0732 -0.2126 -1.7578 -1.5542 -8.8265 -0.0009

3.2838 0.3083 3.2966 1.0582 9.7271 0.0009

59 Envolvente (Cim.tens.terr.) -2.0129 -0.1370 -0.5657 -0.9625 -5.7970 -0.0005

1.9663 0.1900 2.2937 0.6748 5.8171 0.0006

61 Envolvente (Cim.equil.) -2.3403 -0.1825 -1.1609 -1.3759 -7.2252 -0.0007

2.7857 0.2555 2.6294 0.9555 8.1699 0.0009

61 Envolvente (Cim.tens.terr.) -1.5114 -0.1138 -0.2767 -0.8610 -4.6704 -0.0004

1.6946 0.1602 1.8217 0.5968 4.9589 0.0006

63 Envolvente (Cim.equil.) -1.5057 -2.2201 -1.0325 -5.7841 -2.6881 -0.0009

1.2454 1.9123 1.8848 3.6846 3.0679 0.0007

63 Envolvente (Cim.tens.terr.) -0.9414 -1.3951 -0.2428 -3.5976 -1.6811 -0.0006

0.7772 1.1903 1.2792 2.3291 1.9135 0.0004 5.- Esfuerzos

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

24/106

Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)

0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L

53/54 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m

Envolvente (Acero laminado)

N- -1.3672 -1.2653 -1.1634 -1.0615 -0.9596 -0.8578 -0.7559 -0.6540 -0.5521

N+ 0.6067 0.6671 0.7275 0.7878 0.8482 0.9086 0.9690 1.0294 1.0897

Ty- -0.9638 -0.7883 -0.6128 -0.4373 -0.2618 -0.1896 -0.4521 -0.7146 -0.9771

Ty+ 1.1259 0.8634 0.6009 0.3649 0.2513 0.1418 0.0915 0.2670 0.4425

Tz- -1.8608 -1.4881 -1.1154 -0.7463 -0.5843 -0.4704 -0.3566 -0.2853 -0.4873

Tz+ 1.4074 1.1797 0.9519 0.7242 0.4964 0.2687 0.3993 0.7720 1.1446

Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006

Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007

My- -3.6200 -2.6394 -1.7681 -1.0299 -0.5957 -0.9250 -1.0356 -0.9094 -0.5645

My+ 3.5075 2.2185 1.1482 0.5630 1.0720 1.2483 1.0667 0.8665 1.0545

Mz- -1.9721 -1.0995 -0.3954 -0.5869 -0.7992 -0.7386 -0.5733 -0.5486 -0.4188

Mz+ 1.6042 0.9589 0.4317 0.1522 0.4792 0.6498 0.6519 0.4714 1.0134

54/56 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.4773 -0.4670 -0.4567 -0.4465 -0.4362 -0.4259 -0.4157 -0.4055 -0.4009

N+ 1.1602 1.1634 1.1666 1.1698 1.1730 1.1762 1.1794 1.1827 1.1915

Ty- -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541 -0.0541

Ty+ 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677 0.0677

Tz- -0.4932 -0.4653 -0.4807 -0.4961 -0.5263 -0.6123 -0.6983 -0.7844 -0.9393

Tz+ 0.8811 0.6536 0.4305 0.2561 0.2905 0.3953 0.5000 0.6048 0.7095

Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004

Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003

My- -1.0539 -0.8383 -0.6677 -0.4798 -0.2529 -0.2236 -0.2187 -0.4556 -0.7642

My+ 0.5643 0.3903 0.3530 0.2892 0.1941 0.1496 0.3483 0.6740 1.0629

Mz- -0.1067 -0.0812 -0.0559 -0.0305 -0.0052 -0.0259 -0.0578 -0.0897 -0.1216

Mz+ 0.1336 0.1017 0.0699 0.0382 0.0064 0.0207 0.0462 0.0717 0.0972

55/56 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m

Envolvente (Acero laminado)

N- -2.3559 -2.2707 -2.1855 -2.1003 -2.0151 -1.9299 -1.8447 -1.7595 -1.6743

N+ 1.5810 1.6315 1.6820 1.7325 1.7830 1.8335 1.8840 1.9345 1.9850

Ty- -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921 -0.3921

Ty+ 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565 0.2565

Tz- -2.0971 -1.7538 -1.5210 -1.2917 -1.0624 -0.8332 -0.6039 -0.4061 -0.6249

Tz+ 2.5243 2.1568 1.7894 1.4219 1.0544 0.6870 0.7355 1.1030 1.4704

Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -6.3383 -4.3908 -2.6737 -1.2884 -0.4005 -1.3043 -1.8388 -1.9733 -2.0675

My+ 7.0924 4.6499 2.5766 1.2534 1.9159 2.3725 2.4599 2.3039 2.5597

Mz- -1.7836 -1.3730 -0.9625 -0.5520 -0.1456 -0.1660 -0.4346 -0.7032 -0.9717

Mz+ 1.1768 0.9083 0.6397 0.3712 0.1067 0.2691 0.6796 1.0902 1.5007

56/58 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.3722 -0.3619 -0.3516 -0.3414 -0.3311 -0.3208 -0.3106 -0.3032 -0.3000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

25/106

N+ 1.1344 1.1376 1.1408 1.1440 1.1472 1.1504 1.1536 1.1597 1.1700

Ty- -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390 -0.0390

Ty+ 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513 0.0513

Tz- -0.4542 -0.3476 -0.3224 -0.3378 -0.3695 -0.4556 -0.5608 -0.7582 -0.9556

Tz+ 0.7042 0.4766 0.2709 0.2258 0.2664 0.3712 0.4759 0.5807 0.6854

Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002

Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001

My- -0.6017 -0.4605 -0.3331 -0.2478 -0.2173 -0.1241 -0.2481 -0.4980 -0.7952

My+ 0.4746 0.3187 0.2539 0.2014 0.1226 0.1761 0.3633 0.6395 0.9546

Mz- -0.0707 -0.0523 -0.0340 -0.0156 -0.0032 -0.0273 -0.0515 -0.0756 -0.0998

Mz+ 0.0935 0.0693 0.0451 0.0210 0.0027 0.0211 0.0394 0.0578 0.0761

57/58 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m

Envolvente (Acero laminado)

N- -3.0178 -2.9287 -2.8397 -2.7507 -2.6617 -2.5727 -2.4836 -2.3946 -2.3056

N+ 1.9701 2.0229 2.0756 2.1284 2.1811 2.2339 2.2866 2.3394 2.3921

Ty- -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121 -0.3121

Ty+ 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052 0.2052

Tz- -2.8410 -2.3570 -1.8730 -1.5843 -1.3053 -1.0264 -0.7475 -0.6147 -0.8595

Tz+ 3.0629 2.6150 2.1671 1.7193 1.2714 0.8235 0.9744 1.4584 1.9424

Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009

Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009

My- -8.0120 -5.5227 -3.3262 -1.5847 -0.5761 -1.7119 -2.3774 -2.5335 -2.8759

My+ 8.9052 5.8099 3.1848 1.6504 2.7533 3.4679 3.6743 3.4131 3.7497

Mz- -1.5396 -1.1982 -0.8568 -0.5221 -0.1932 -0.1118 -0.3286 -0.5530 -0.7774

Mz+ 1.0178 0.7934 0.5690 0.3513 0.1394 0.1674 0.5088 0.8502 1.1916

58/60 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -0.5316 -0.5179 -0.5042 -0.4905 -0.4769 -0.4632 -0.4495 -0.4358 -0.4270

N+ 1.2271 1.2314 1.2356 1.2399 1.2442 1.2485 1.2527 1.2570 1.2662

Ty- -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158

Ty+ 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141 0.0141

Tz- -0.6417 -0.4810 -0.3204 -0.1948 -0.2049 -0.3366 -0.5871 -0.8503 -1.1135

Tz+ 0.9924 0.7292 0.4659 0.2027 0.1377 0.2774 0.4170 0.5701 0.7324

Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001

Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

My- -0.5215 -0.3777 -0.3424 -0.4460 -0.4939 -0.3699 -0.1493 -0.3867 -0.7785

My+ 0.6767 0.2420 0.2668 0.3146 0.3102 0.2510 0.2317 0.4827 0.9810

Mz- -0.0398 -0.0299 -0.0199 -0.0100 -0.0022 -0.0110 -0.0199 -0.0287 -0.0376

Mz+ 0.0331 0.0243 0.0155 0.0074 0.0022 0.0099 0.0198 0.0297 0.0397

59/60 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m

Envolvente (Acero laminado)

N- -3.0106 -2.9165 -2.8224 -2.7283 -2.6342 -2.5401 -2.4460 -2.3519 -2.2578

N+ 1.8434 1.8991 1.9549 2.0107 2.0664 2.1222 2.1780 2.2337 2.2895

Ty- -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901 -0.2901

Ty+ 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989 0.1989

Tz- -2.8682 -2.3566 -1.8476 -1.5528 -1.2579 -0.9631 -0.6682 -0.5944 -0.9867

Tz+ 3.1102 2.6367 2.1632 1.6897 1.2163 0.7428 0.9344 1.4461 1.9577

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

26/106

Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -8.2355 -5.5947 -3.2811 -1.4531 -0.7896 -1.9112 -2.5072 -2.5339 -2.6182

My+ 9.2153 5.9038 3.1179 1.6320 2.8617 3.5041 3.5787 3.2644 3.6793

Mz- -1.4604 -1.1250 -0.7896 -0.4570 -0.1361 -0.1593 -0.3893 -0.6193 -0.8494

Mz+ 0.9908 0.7607 0.5307 0.3035 0.0880 0.2166 0.5520 0.8874 1.2228

60/62 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.6572 -0.6469 -0.6366 -0.6264 -0.6161 -0.6058 -0.5956 -0.5853 -0.5804

N+ 1.3415 1.3447 1.3479 1.3511 1.3543 1.3575 1.3607 1.3639 1.3725

Ty- -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258 -0.0258

Ty+ 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277 0.0277

Tz- -0.5063 -0.3858 -0.3102 -0.3162 -0.3316 -0.4034 -0.4894 -0.6549 -0.8891

Tz+ 0.7884 0.5910 0.3935 0.2106 0.1946 0.2851 0.3898 0.4946 0.5993

Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001

Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002

My- -0.5809 -0.4499 -0.3120 -0.2268 -0.2469 -0.1979 -0.1626 -0.3532 -0.6099

My+ 0.4947 0.2724 0.2041 0.1840 0.1347 0.1511 0.3130 0.5459 0.8365

Mz- -0.0498 -0.0376 -0.0255 -0.0133 -0.0029 -0.0096 -0.0227 -0.0358 -0.0488

Mz+ 0.0557 0.0426 0.0295 0.0165 0.0034 0.0110 0.0231 0.0353 0.0474

61/62 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m

Envolvente (Acero laminado)

N- -2.3978 -2.2998 -2.2019 -2.1040 -2.0061 -1.9082 -1.8102 -1.7123 -1.6144

N+ 1.2529 1.3110 1.3690 1.4270 1.4850 1.5431 1.6011 1.6591 1.7172

Ty- -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395 -0.2395

Ty+ 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712 0.1712

Tz- -2.1870 -1.7729 -1.4857 -1.2222 -0.9588 -0.6953 -0.4318 -0.4920 -0.9143

Tz+ 2.6286 2.2063 1.7840 1.3617 0.9394 0.5171 0.6861 1.1084 1.5307

Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008

Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006

My- -6.7515 -4.4948 -2.5425 -0.9918 -0.8722 -1.7383 -2.1166 -1.9665 -1.6978

My+ 7.7133 4.8150 2.4044 1.2978 2.1609 2.4957 2.3428 2.4262 2.4766

Mz- -1.2898 -1.0017 -0.7144 -0.4282 -0.1419 -0.1339 -0.3399 -0.5459 -0.7519

Mz+ 0.8960 0.6900 0.4848 0.2807 0.0765 0.1506 0.4387 0.7268 1.0149

62/64 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.7343 -0.7240 -0.7138 -0.7035 -0.6932 -0.6830 -0.6727 -0.6624 -0.6561

N+ 1.4781 1.4813 1.4845 1.4877 1.4909 1.4941 1.4973 1.5005 1.5077

Ty- -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408 -0.0408

Ty+ 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533 0.0533

Tz- -0.4969 -0.3764 -0.2559 -0.2029 -0.3459 -0.5714 -0.8056 -1.0709 -1.3774

Tz+ 0.5997 0.3655 0.2316 0.1938 0.2254 0.3214 0.4262 0.5309 0.6357

Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003

Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004

My- -0.3577 -0.3232 -0.3213 -0.3376 -0.3114 -0.1691 -0.2320 -0.4144 -0.6882

My+ 0.3598 0.2583 0.2203 0.1920 0.1746 0.2308 0.4912 0.8840 1.4268

Mz- -0.0751 -0.0559 -0.0366 -0.0174 -0.0031 -0.0282 -0.0533 -0.0784 -0.1035

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

27/106

Mz+ 0.0977 0.0726 0.0475 0.0224 0.0032 0.0214 0.0406 0.0599 0.0791

63/64 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m

Envolvente (Acero laminado)

N- -1.7066 -1.5627 -1.4188 -1.2748 -1.1309 -0.9870 -0.8431 -0.6991 -0.5552

N+ 1.1155 1.2008 1.2861 1.3714 1.4567 1.5420 1.6272 1.7125 1.7978

Ty- -1.1680 -0.9487 -0.7293 -0.5099 -0.2905 -0.2312 -0.5593 -0.8874 -1.2156

Ty+ 1.4115 1.0833 0.7552 0.4376 0.2730 0.1361 0.1502 0.3696 0.5890

Tz- -1.7946 -1.5099 -1.2252 -0.9405 -0.6559 -0.3964 -0.7373 -1.2032 -1.6690

Tz+ 2.0806 1.6148 1.1489 0.6831 0.3803 0.2379 0.0956 0.2211 0.5058

Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -5.4290 -3.3708 -1.6543 -1.7189 -2.2930 -2.2617 -1.6714 -0.8333 -0.6895

My+ 3.4517 2.0188 1.0950 0.3618 0.6971 1.3318 1.6250 1.5480 1.4275

Mz- -2.8776 -1.5602 -0.5060 -0.9196 -1.2565 -1.1669 -0.8055 -0.7156 -0.4615

Mz+ 2.5195 1.3320 0.5596 0.2630 0.7688 0.9894 0.9467 0.6188 1.5434 6.- Tensiones

Barras TENSIÓN MÁXIMA

TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)

53/54 0.7940 79.40 0.000 -0.0334 -0.9615 -1.8608 -0.0003 -3.3896 -1.9659

54/56 0.7742 77.42 0.000 -0.1406 -0.0285 -0.4499 0.0000 -1.0539 -0.0565

55/56 0.6603 66.03 0.000 1.5810 -0.1090 2.5243 0.0000 7.0924 -0.5038

56/58 0.5811 58.11 3.769 -0.1767 0.0194 0.6854 -0.0002 -0.7952 -0.0374

57/58 0.8048 80.48 0.000 1.9701 -0.0591 3.0629 -0.0003 8.9052 -0.3538

58/60 0.7251 72.51 5.025 -0.0167 0.0115 0.6964 0.0000 -0.7785 -0.0288

59/60 0.8828 88.28 0.000 1.8434 -0.1049 3.1102 -0.0005 9.2153 -0.4836

60/62 0.4618 46.18 3.769 0.1388 0.0185 0.5993 0.0002 -0.6099 -0.0339

61/62 0.7629 76.29 0.000 1.2529 -0.0860 2.6286 -0.0008 7.7133 -0.4224

62/64 0.5722 57.22 3.769 1.5037 -0.0408 -1.2740 0.0003 1.4268 0.0786

63/64 0.9113 91.13 0.000 0.5252 1.4112 -1.7874 0.0008 -5.4034 2.5186

Resultados de cálculo en pórtico intermedio 1.- Barras: Descripción

Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.

(kp) (m³) (m) (m) (m)

13/14 Acero (S275) HE 260 A (HEA) 545.10 0.069 8.00 0.70 1.33 8.00 8.00

14/15 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

15/16 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

16/17 Acero (S275) IPE 450 (IPE) 389.72 0.050 5.02 0.05 0.73 1.00 5.02

17/18 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

18/20 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

19/20 Acero (S275) HE 300 A (HEA) 883.12 0.112 10.00 0.70 1.28 10.00 10.00

2.- Cargas (Barras)

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

28/106

Barras Hipót. Tipo Cargas Dirección

P1 P2 L1 (m) L2 (m) X Y Z

13/14 1 (PP 1) Uniforme 0.068 t/m - - - 0.000 0.000 -1.000

13/14 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

13/14 3 (V 1) Uniforme 0.304 t/m - - - 0.000 1.000 0.000

13/14 4 (V 2) Uniforme 0.304 t/m - - - 0.000 1.000 0.000

13/14 5 (V 3) Uniforme 0.149 t/m - - - 0.000 -1.000 0.000

13/14 5 (V 3) Uniforme 0.232 t/m - - - 0.000 -1.000 0.000

13/14 6 (V 4) Uniforme 0.152 t/m - - - 0.000 -1.000 0.000

13/14 7 (V 5) Uniforme 0.207 t/m - - - 0.000 -1.000 0.000

14/15 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

14/15 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

14/15 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

14/15 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 2.010 3.769 0.000 -0.100 0.995

14/15 3 (V 1) Trapez. 0.583 t/m 0.583 t/m 0.000 2.010 0.000 -0.100 0.995

14/15 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 2.010 3.769 0.000 0.100 -0.995

14/15 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 2.010 0.000 0.100 -0.995

14/15 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

14/15 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995

14/15 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

14/15 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

14/15 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

15/16 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

15/16 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

15/16 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

15/16 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995

15/16 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995

15/16 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

15/16 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995

15/16 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

15/16 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

15/16 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

16/17 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

16/17 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

16/17 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

16/17 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995

16/17 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995

16/17 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

16/17 6 (V 4) Uniforme 0.334 t/m - - - 0.000 -0.100 0.995

16/17 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

16/17 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

16/17 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

17/18 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

17/18 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

17/18 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

17/18 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

29/106

17/18 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995

17/18 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

17/18 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

17/18 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

17/18 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

17/18 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

18/20 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

18/20 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

18/20 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

18/20 3 (V 1) Uniforme 0.240 t/m - - - 0.000 -0.100 0.995

18/20 4 (V 2) Uniforme 0.006 t/m - - - 0.000 0.100 -0.995

18/20 5 (V 3) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

18/20 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995

18/20 6 (V 4) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995

18/20 7 (V 5) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

18/20 8 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

18/20 9 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

19/20 1 (PP 1) Uniforme 0.088 t/m - - - 0.000 0.000 -1.000

19/20 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

19/20 3 (V 1) Uniforme 0.152 t/m - - - 0.000 1.000 0.000

19/20 4 (V 2) Uniforme 0.152 t/m - - - 0.000 1.000 0.000

19/20 5 (V 3) Uniforme 0.149 t/m - - - 0.000 1.000 0.000

19/20 5 (V 3) Uniforme 0.232 t/m - - - 0.000 1.000 0.000

19/20 6 (V 4) Uniforme 0.304 t/m - - - 0.000 -1.000 0.000

19/20 7 (V 5) Uniforme 0.207 t/m - - - 0.000 1.000 0.000 3.- Desplazamientos

Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)

DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)

13 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

14 Envolvente (Desplazam.) -0.0176 -0.0364 -0.0002 -0.0069 -0.0007 -0.0027

0.0176 0.0249 0.0000 0.0027 0.0007 0.0028

15 Envolvente (Desplazam.) -0.0305 -0.0371 -0.0268 -0.0064 -0.0017 -0.0030

0.0306 0.0276 0.0065 0.0009 0.0048 0.0034

16 Envolvente (Desplazam.) -0.0411 -0.0372 -0.0445 -0.0028 -0.0023 -0.0018

0.0411 0.0293 0.0077 -0.0001 0.0082 0.0024

17 Envolvente (Desplazam.) -0.0451 -0.0368 -0.0416 -0.0010 -0.0017 -0.0004

0.0452 0.0290 0.0041 0.0036 0.0080 0.0010

18 Envolvente (Desplazam.) -0.0381 -0.0365 -0.0223 -0.0007 -0.0008 -0.0024

0.0382 0.0270 0.0005 0.0062 0.0044 0.0029

19 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

20 Envolvente (Desplazam.) -0.0256 -0.0365 -0.0002 -0.0003 -0.0010 -0.0028

0.0256 0.0248 0.0000 0.0049 0.0011 0.0029

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

30/106

4.- Reacciones

Nudos Descripción REACCIONES (EJES GENERALES)

RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)

13 Envolvente (Cim.equil.) -0.4248 -3.3740 -0.4557 -11.8280 -1.8079 -0.0024

0.4292 3.5315 6.5812 8.1702 1.8185 0.0023

13 Envolvente (Cim.tens.terr.) -0.2655 -1.8932 0.7887 -8.0101 -1.1300 -0.0015

0.2684 2.4432 4.6167 4.5425 1.1370 0.0015

19 Envolvente (Cim.equil.) -0.5176 -4.0794 -1.5820 -17.3800 -2.8097 -0.0032

0.5258 5.1257 7.7765 14.4816 2.8360 0.0030

19 Envolvente (Cim.tens.terr.) -0.3235 -2.7852 0.2413 -10.1561 -1.7561 -0.0020

0.3287 2.9885 5.6340 9.8249 1.7730 0.0019 5.- Esfuerzos

Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)

0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L

13/14 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m

Envolvente (Acero laminado)

N- -6.0089 -5.8494 -5.6899 -5.5304 -5.3709 -5.2114 -5.0520 -4.8925 -4.7330

N+ 0.8208 0.9153 1.0098 1.1043 1.1988 1.2934 1.3879 1.4824 1.5769

Ty- -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024 -0.4024

Ty+ 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982 0.3982

Tz- -3.2785 -2.9899 -2.7622 -2.5345 -2.3067 -2.0790 -1.8512 -1.6450 -1.6444

Tz+ 3.2421 2.7866 2.3311 1.8756 1.4201 0.9646 0.9365 1.5080 2.0794

Mt- -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022 -0.0022

Mt+ 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023 0.0023

My- -11.0042 -7.9049 -5.0243 -2.6819 -1.4581 -2.6413 -3.3873 -3.6595 -3.4945

My+ 7.8663 5.0008 2.8670 1.6466 2.6308 3.5949 4.7994 6.5022 8.0817

Mz- -1.7050 -1.3026 -0.9002 -0.4980 -0.0965 -0.2964 -0.6947 -1.0929 -1.4912

Mz+ 1.6948 1.2966 0.8983 0.5003 0.1029 0.3070 0.7094 1.1118 1.5142

14/15 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -2.0577 -2.0307 -2.0037 -1.9767 -1.9497 -1.9227 -1.8957 -1.8686 -1.8416

N+ 2.1270 2.1351 2.1433 2.1514 2.1595 2.1677 2.1758 2.1839 2.1921

Ty- -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417 -0.2417

Ty+ 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105 0.2105

Tz- -4.2148 -3.9447 -3.6745 -3.4044 -3.1343 -2.8642 -2.5941 -2.3240 -2.0538

Tz+ 2.0645 1.7341 1.4036 1.1251 1.0556 0.9865 0.9174 0.8483 0.7791

Mt- -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057 -0.0057

Mt+ 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093 0.0093

My- -8.0823 -6.9079 -6.2791 -5.6924 -5.1049 -4.9067 -5.0277 -5.0728 -5.0478

My+ 3.4944 2.6028 1.8606 1.8382 2.2663 3.0427 4.1003 5.0410 5.8738

Mz- -0.4856 -0.3718 -0.2579 -0.1440 -0.0302 -0.0787 -0.1775 -0.2767 -0.3759

Mz+ 0.4174 0.3182 0.2191 0.1199 0.0208 0.0839 0.1975 0.3114 0.4253

15/16 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.8762 -1.8492 -1.8222 -1.7951 -1.7681 -1.7411 -1.7141 -1.6871 -1.6601

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

31/106

N+ 2.1985 2.2067 2.2148 2.2230 2.2311 2.2392 2.2474 2.2555 2.2636

Ty- -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625 -0.1625

Ty+ 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420 0.1420

Tz- -2.5497 -2.2795 -2.0094 -1.7393 -1.4692 -1.1991 -0.9290 -0.7955 -0.7880

Tz+ 0.7255 0.6554 0.5863 0.5172 0.4481 0.3790 0.3098 0.2407 0.1716

Mt- -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031 -0.0031

Mt+ 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066

My- -5.0481 -5.3178 -5.5175 -5.6414 -5.6952 -5.6731 -5.5811 -5.4132 -5.1753

My+ 5.8734 6.7840 7.5867 8.3700 9.0760 9.6484 10.0975 10.4130 10.6052

Mz- -0.1411 -0.0645 -0.0291 -0.0956 -0.1622 -0.2289 -0.2958 -0.3627 -0.4296

Mz+ 0.1055 0.0508 0.0318 0.0891 0.1653 0.2417 0.3183 0.3949 0.4714

16/17 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -1.7408 -1.7048 -1.6688 -1.6328 -1.5968 -1.5608 -1.5247 -1.4887 -1.4527

N+ 2.2932 2.3041 2.3149 2.3258 2.3366 2.3475 2.3583 2.3692 2.3800

Ty- -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479 -0.0479

Ty+ 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340 0.0340

Tz- -1.3722 -1.0120 -0.6519 -0.4326 -0.4717 -0.6781 -0.8845 -1.0910 -1.2974

Tz+ 0.5514 0.4341 0.3168 0.2031 0.3125 0.6306 0.9488 1.3103 1.6738

Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009

Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009

My- -5.1760 -5.3309 -5.3614 -5.2570 -5.0282 -4.6645 -4.1763 -3.5533 -2.8058

My+ 10.6053 11.2617 11.6989 11.8987 11.8793 11.6225 11.1465 10.4331 9.5004

Mz- -0.1718 -0.1927 -0.2136 -0.2345 -0.2554 -0.2764 -0.2977 -0.3190 -0.3403

Mz+ 0.1368 0.1665 0.1961 0.2258 0.2554 0.2852 0.3153 0.3454 0.3754

17/18 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.5205 -1.4934 -1.4664 -1.4394 -1.4124 -1.3854 -1.3584 -1.3314 -1.3044

N+ 2.4444 2.4525 2.4606 2.4688 2.4769 2.4850 2.4932 2.5013 2.5094

Ty- -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334 -0.1334

Ty+ 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136 0.1136

Tz- -0.5037 -0.6586 -0.8134 -0.9682 -1.1230 -1.2778 -1.4326 -1.5875 -1.7423

Tz+ 0.9699 1.2086 1.4472 1.6858 1.9319 2.2045 2.4771 2.7497 3.0223

Mt- -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069 -0.0069

Mt+ 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039 0.0039

My- -2.8064 -2.5311 -2.1859 -2.0495 -2.0106 -1.9287 -1.8069 -1.6421 -1.4374

My+ 9.5009 9.0505 8.5835 7.9980 7.2904 6.4504 5.4883 4.3938 3.3999

Mz- -0.5346 -0.4717 -0.4089 -0.3460 -0.2832 -0.2205 -0.1582 -0.0959 -0.0692

Mz+ 0.4950 0.4415 0.3880 0.3345 0.2810 0.2276 0.1747 0.1217 0.0687

18/20 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.3151 -1.2881 -1.2611 -1.2341 -1.2071 -1.1801 -1.1530 -1.1260 -1.0990

N+ 2.5907 2.5988 2.6070 2.6151 2.6232 2.6314 2.6395 2.6476 2.6558

Ty- -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173 -0.3173

Ty+ 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896 0.2896

Tz- -1.1942 -1.3491 -1.5039 -1.6587 -1.8914 -2.3388 -2.7863 -3.2337 -3.6811

Tz+ 2.8327 3.0713 3.3177 3.5903 3.8629 4.1355 4.4082 4.6808 4.9534

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

32/106

Mt- -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083 -0.0083

Mt+ 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040 0.0040

My- -1.4372 -1.4597 -2.1110 -3.3031 -5.0287 -6.8713 -8.8217 -10.8890 -13.0643

My+ 3.4001 3.1471 3.1220 3.4428 4.2641 5.2647 6.4677 7.8899 9.5144

Mz- -0.6112 -0.4618 -0.3123 -0.1628 -0.0165 -0.1143 -0.2506 -0.3870 -0.5234

Mz+ 0.5679 0.4315 0.2951 0.1587 0.0223 0.1364 0.2858 0.4352 0.5847

19/20 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m

Envolvente (Acero laminado)

N- -7.1060 -6.8726 -6.6392 -6.4058 -6.1724 -5.9390 -5.7056 -5.4722 -5.2387

N+ 1.9341 2.0725 2.2108 2.3491 2.4874 2.6257 2.7640 2.9023 3.0406

Ty- -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929 -0.4929

Ty+ 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852 0.4852

Tz- -4.8842 -4.3148 -3.7455 -3.1761 -2.6067 -2.0373 -1.4680 -2.1064 -2.8207

Tz+ 3.7922 3.5075 3.2228 2.9381 2.6534 2.3687 2.0840 1.7994 1.5786

Mt- -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029 -0.0029

Mt+ 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030 0.0030

My- -16.5527 -10.8176 -5.7657 -2.6896 -4.0692 -5.7751 -8.5652 -10.9852 -13.0636

My+ 13.4705 8.9154 4.7018 1.2239 2.1745 5.0628 7.2679 8.7327 9.5143

Mz- -2.6589 -2.0428 -1.4266 -0.8107 -0.1955 -0.3984 -1.0049 -1.6114 -2.2179

Mz+ 2.6340 2.0275 1.4210 0.8149 0.2094 0.4220 1.0382 1.6543 2.2705 6.- Tensiones

Barras TENSIÓN MÁXIMA

TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)

13/14 0.7336 73.36 0.000 -3.1059 0.0171 -3.2177 -0.0002 -11.0042 0.0433

14/15 0.2701 27.01 0.000 -1.8066 0.0347 -2.7432 0.0037 -8.0823 0.0752

15/16 0.2444 24.44 3.769 -1.6601 -0.0169 -0.2663 0.0064 10.6052 0.0349

16/17 0.2692 26.92 2.010 -1.6256 -0.0119 -0.0709 -0.0007 11.9167 -0.0059

17/18 0.2196 21.96 0.000 -1.5205 -0.0171 0.8414 -0.0069 9.5009 -0.0348

18/20 0.4278 42.78 3.769 -1.0625 -0.0462 4.7416 -0.0064 -13.0643 0.1007

19/20 0.7386 73.86 0.000 1.9341 0.0377 -4.8842 -0.0002 -16.5527 0.1218

2.1.2 Cimentación

La cimentación se realiza mediante zapatas centradas para todos los

pilares, arriostradas mediante vigas de atado de hormigón armado.

Tanto las zapatas como las vigas de atado se realizarán con hormigón

armado HA-35/B/20/IV-Qc sobre cama de hormigón de limpieza HM-10 de 10

cm de espesor, y armadura de redondos de acero B-400-S.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

33/106

• Acciones adoptadas en el cálculo

Para los elementos de cimentación de hormigón armado, se han

considerado las siguientes acciones:

Densidad del hormigón armado 2.50 tn/m² (2.30 t/m3 para hormigones en masa y poco armados)

Cargas y sobrecargas: Las consideradas en el CTE DB SE-A

Acciones de la estructura sobre la cimentación.

• Métodos de cálculo e hipótesis de carga

Para el cálculo de los elementos de hormigón se han considerado los

siguientes coeficientes de seguridad, correspondientes a la EHE.

COEFICIENTE DE PONDERACIÓN Y SEGURIDAD

Coeficiente de minoración de resistencia del hormigón γc = 1,50

Coeficiente de minoración de resistencia del acero γs = 1,15

Coeficiente de mayoración de las acciones γf = 1,60

• Resultados obtenidos en el cálculo de la cimentación

Descripción

Referencias Materiales Geometría Armado

Nudo 1 Nudo 15 Nudo 83 Nudo 97

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata cuadrada Ancho: 230.0 cm Canto: 55.0 cm

Sup X: 11Ø12c/20 Sup Y: 11Ø12c/20 Inf X: 11Ø12c/20 Inf Y: 11Ø12c/20

Nudo 28 Nudo 41 Nudo 54 Nudo 67 Nudo 80

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 370.0 cm Ancho zapata Y: 190.0 cm Canto: 90.0 cm

Sup X: 29Ø12c/12.5 Sup Y: 15Ø12c/12.5 Inf X: 29Ø12c/12.5 Inf Y: 15Ø12c/12.5

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

34/106

Nudo 3 Nudo 6 Nudo 9 Nudo 12 Nudo 85 Nudo 88 Nudo 91 Nudo 94

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 250.0 cm Ancho zapata Y: 120.0 cm Canto: 60.0 cm

Sup X: 14Ø12c/18 Sup Y: 6Ø12c/18 Inf X: 14Ø12c/18 Inf Y: 6Ø12c/18

Nudo 18 Nudo 31 Nudo 44 Nudo 57 Nudo 70

Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.250 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 330.0 cm Ancho zapata Y: 170.0 cm Canto: 80.0 cm

Sup X: 13Ø16c/25 Sup Y: 7Ø16c/25 Inf X: 13Ø16c/25 Inf Y: 7Ø16c/25

Descripción

A continuación mostramos las comprobaciones para una zapata de cada

tipo:

• Zapata NUDO 1:

Referencia: 1

Dimensiones: 230 x 230 x 55

Armados: Xi:Ø12c/20 Yi:Ø12c/20 Xs:Ø12c/20 Ys:Ø12c/20

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.176 kp/cm²

Cumple -Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.158 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.423 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 272.3 %

Cumple -En dirección Y:

Reserva seguridad: 29.6 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 1.15 t�m

Cumple

-En dirección Y:

Momento: 3.79 t�m

Cumple

Cortante en la zapata:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

35/106

-En dirección X:

Cortante: 1.22 t

Cumple

-En dirección Y:

Cortante: 4.44 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 6.34 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 55 cm

Cumple

Espacio para anclar arranques en cimentación:

-1:

Mínimo: 0 cm Calculado: 48 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0003

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-98)

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 20 cm

Cumple

-Armado inferior dirección Y:

Calculado: 20 cm

Cumple

-Armado superior dirección X:

Calculado: 20 cm

Cumple

-Armado superior dirección Y:

Calculado: 20 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 20 cm

Cumple

-Armado inferior dirección Y:

Calculado: 20 cm

Cumple

-Armado superior dirección X:

Calculado: 20 cm

Cumple -Armado superior dirección Y:

Calculado: 20 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 59 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 59 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 59 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 59 cm

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

36/106

-Armado sup. dirección X hacia der:

Calculado: 59 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 59 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 59 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 59 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.07

- Relación rotura pésima (En dirección Y): 0.20

- Cortante de agotamiento (En dirección X): 31.64 t

- Cortante de agotamiento (En dirección Y): 31.64 t

• Zapata NUDO 9:

Referencia: 9

Dimensiones: 120 x 250 x 60

Armados: Xi:Ø12c/18 Yi:Ø12c/18 Xs:Ø12c/18 Ys:Ø12c/18

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.214 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.214 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.391 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 1690.9 %

Cumple

-En dirección Y:

Reserva seguridad: 4.3 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 0.39 t�m

Cumple

-En dirección Y:

Momento: 2.19 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 0.06 t

Cumple

-En dirección Y:

Cortante: 2.38 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 11.12 t/m²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

37/106

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 60 cm

Cumple

Espacio para anclar arranques en cimentación:

-9:

Mínimo: 0 cm Calculado: 53 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0003

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 18 cm

Cumple

-Armado inferior dirección Y:

Calculado: 18 cm

Cumple

-Armado superior dirección X:

Calculado: 18 cm

Cumple

-Armado superior dirección Y:

Calculado: 18 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 18 cm

Cumple

-Armado inferior dirección Y:

Calculado: 18 cm

Cumple

-Armado superior dirección X:

Calculado: 18 cm

Cumple

-Armado superior dirección Y:

Calculado: 18 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 65 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 65 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 65 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 65 cm

Cumple

Longitud mínima de las patillas: Mínimo: 12 cm

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

38/106

-Armado inf. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 15 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.02

- Relación rotura pésima (En dirección Y): 0.19

- Cortante de agotamiento (En dirección X): 37.35 t

- Cortante de agotamiento (En dirección Y): 17.65 t

• Zapata NUDO 18:

Referencia: 18

Dimensiones: 170 x 330 x 80

Armados: Xi:Ø16c/25 Yi:Ø16c/25 Xs:Ø16c/25 Ys:Ø16c/25

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.352 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.431 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.524 kp/cm²

Cumple

Vuelco de la zapata:

-En dirección X (1)

No procede

-En dirección Y:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

Reserva seguridad: 16.7 %

Cumple (1)Sin momento de vuelco

Flexión en la zapata:

-En dirección X:

Momento: 2.38 t�m

Cumple

-En dirección Y:

Momento: 7.59 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 0.28 t

Cumple

-En dirección Y:

Cortante: 5.26 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 31.46 t/m²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

39/106

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 80 cm

Cumple

Espacio para anclar arranques en cimentación:

-18:

Mínimo: 0 cm Calculado: 72 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0004

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 16 mm

Cumple

-Parrilla superior:

Calculado: 16 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 25 cm

Cumple

-Armado inferior dirección Y:

Calculado: 25 cm

Cumple

-Armado superior dirección X:

Calculado: 25 cm

Cumple

-Armado superior dirección Y:

Calculado: 25 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 25 cm

Cumple

-Armado inferior dirección Y:

Calculado: 25 cm

Cumple

-Armado superior dirección X:

Calculado: 25 cm

Cumple

-Armado superior dirección Y:

Calculado: 25 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 16 cm

-Armado inf. dirección X hacia der:

Calculado: 16 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 16 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 89 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 89 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 16 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 16 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 89 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 89 cm

Cumple

Longitud mínima de las patillas: Mínimo: 16 cm

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

40/106

-Armado inf. dirección X hacia der:

Calculado: 16 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 16 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 16 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 16 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.04

- Relación rotura pésima (En dirección Y): 0.26

- Cortante de agotamiento (En dirección X): 62.46 t

- Cortante de agotamiento (En dirección Y): 31.86 t

• Zapata NUDO 41:

Referencia: 41

Dimensiones: 190 x 370 x 90

Armados: Xi:Ø12c/12.5 Yi:Ø12c/12.5 Xs:Ø12c/12.5 Ys:Ø12c/12.5

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.35 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.414 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.598 kp/cm²

Cumple

Vuelco de la zapata:

-En dirección X (1)

No procede

-En dirección Y:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

Reserva seguridad: 12.7 %

Cumple (1)Sin momento de vuelco

Flexión en la zapata:

-En dirección X:

Momento: 2.72 t�m

Cumple

-En dirección Y:

Momento: 12.80 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 0.09 t

Cumple

-En dirección Y:

Cortante: 9.29 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 22.87 t/m²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

41/106

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 90 cm

Cumple

Espacio para anclar arranques en cimentación:

-41:

Mínimo: 0 cm Calculado: 83 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0005

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0004

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 12.5 cm

Cumple

-Armado inferior dirección Y:

Calculado: 12.5 cm

Cumple

-Armado superior dirección X:

Calculado: 12.5 cm

Cumple

-Armado superior dirección Y:

Calculado: 12.5 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 12.5 cm

Cumple

-Armado inferior dirección Y:

Calculado: 12.5 cm

Cumple

-Armado superior dirección X:

Calculado: 12.5 cm

Cumple

-Armado superior dirección Y:

Calculado: 12.5 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 100 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 100 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 100 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 100 cm

Cumple

Longitud mínima de las patillas: Mínimo: 12 cm

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

42/106

-Armado inf. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 15 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 15 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.04

- Relación rotura pésima (En dirección Y): 0.30

- Cortante de agotamiento (En dirección X): 77.90 t

- Cortante de agotamiento (En dirección Y): 39.65 t

2.2 Nave de Proceso

2.2.1 Estructura

La estructura de la Nave de Proceso se ha calculado empleando perfiles de

acero laminado S 275 JR. Está formada por dos partes; la primera está

constituida por 8 pórticos rígidos a un agua de 20 m de luz, con 8 m de altura

en los pilares aguas abajo y 10 m en los pilares aguas arriba; y la segunda por

3 pórticos rígidos a un agua de 10 m de luz, con 6 m de altura en los pilares

aguas abajo y 7 m en los pilares aguas arriba, en todos los casos respecto a la

solera terminada (ver figura).

Los pilares irán empotrados en su base a la cimentación mediante placas

de anclaje, con una separación entre pórticos 5 m.

Las correas están formadas por perfiles laminados en caliente IPE 140

separados entre sí 1 m, que reciben la carga de la cubierta.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

43/106

Fig. 5: Detalle de un pórtico intermedio y las correas (cotas en m)

La tipología de la estructura se puede ver de una forma más clara en la

siguiente figura, en la que se muestra una representación 3D de la misma:

Fig. 6: Vista 3D de la estructura metálica

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

44/106

• Acciones adoptadas en el cálculo

Todos los valores de las acciones que se han aplicado en el cálculo de

cada uno de los elementos resistentes se ajustan a lo prescrito en la Norma

“CTE DB SE-AE Acciones en la Edificación”, siendo sus valores los siguientes:

Acciones Gravitatorias

Concargas Peso Propio

Cubierta de chapa: 20 kg/m²

Estructura: 7.850 kg/m³

Carga Permanente -

Sobrecargas De Uso 40 kg/m2

De Nieve H: 300 m 20 kg/m²

Acciones del Viento Según CTE DB SE-AE

Altura Coronación < 10 m. Situación Expuesta.

Acciones Térmicas No se necesitan juntas de dilatación

Acciones Reológicas

No han sido consideradas por tratarse de una estruc-tura toda ella realizada con materiales metálicos y

ser, por tanto, despreciables los efectos de las mismas, según indica la Norma CTE DB SE-A.

Acciones Sísmicas

No han sido consideradas por ser la aceleración básica menor que la mínima exigida para realizar los

cálculos sísmicos según indica el CTE

• Especificaciones de los materiales

El acero empleado en la estructura será del tipo S 275 JR con límite

elástico σe = 275 N/mm2, la estructura secundaria (correas) será del tipo S 275

JR con límite elástico σe = 275 N/mm2. La resistencia de cálculo del acero viene

fijada por la expresión: σu = σe / γa, donde γa es el coeficiente de minoración,

con valor 1, pues el acero tendrá el límite elástico mínimo garantizado.

Las constantes elásticas del acero serán las siguientes:

Módulo de elasticidad E = 2100000 kg/cm2

Módulo de elasticidad transversal G = 810000 kg/cm2

Coeficiente de Poisson µ = 0.30

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

45/106

El coeficiente de dilatación térmica del acero para el cálculo de esfuerzos,

tensiones y deformaciones se tomará: αt = 0.000012 m/m°C.

• Métodos de cálculo e hipótesis de carga

El cálculo se ha realizado mediante programa informático comercial

“METAL 3D” de la casa especializada “CYPE INGENIEROS, S.A.”,

comprobándose la estabilidad estática y elástica, las tensiones y las

deformaciones.

Dichos cálculos están basados en las leyes de la mecánica y en la teoría

de la elasticidad, admitiendo, en alguna ocasión y de modo implícito, la

existencia de estados tensionales plásticos locales.

Las hipótesis de carga utilizadas son las establecidas en el CTE DB SE-AE y

las acciones características las prescritas en el CTE DB SE-AE. Las acciones

consideradas en este cálculo han sido las siguientes:

Acciones constantes:

- el peso propio;

- la carga permanente;

- las acciones térmicas;

Acciones variables:

- las sobrecargas de uso o explotación;

- las acciones de viento;

- la sobrecarga producida por la nieve;

Los coeficientes de ponderación según la hipótesis de carga, la clase de

acción y el efecto favorable o desfavorable de la acción sobre la estabilidad o

las tensiones se dan en el cuadro siguiente:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

46/106

• Resultados en el cálculo de esfuerzos sobre la estructura

Se muestran a continuación los resultados del cálculo sobre la estructura

principal y correas. No se incluyen en estos listados los resultados sobre las

cruces de San Andrés.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

47/106

Resultados de cálculo en pórtico hastial delantero 1.- Barras: Descripción

Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.

(kp) (m³) (m) (m) (m)

1/2 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00

2/4 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

3/4 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 -

4/6 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

5/6 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 -

6/8 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02

7/8 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 -

8/10 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

9/10 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 -

10/13 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

11/12 Acero (S275) HE 240 A (HEA) 422.02 0.054 7.00 0.70 1.22 7.00 7.00

12/13 Acero (S275) HE 240 A (HEA) 180.86 0.023 3.00 2.33 1.80 3.00 3.00

15/12 Acero (S275) IPE 180 (IPE) 94.28 0.012 5.02 0.10 0.76 1.00 5.02

14/15 Acero (S275) HE 220 A (HEA) 328.09 0.042 6.50 0.70 1.23 6.50 -

17/15 Acero (S275) IPE 180 (IPE) 94.28 0.012 5.02 0.10 0.76 1.00 5.02

16/17 Acero (S275) HE 220 A (HEA) 302.85 0.039 6.00 0.70 1.25 6.00 6.00

2.- Cargas (Barras)

Barras Hipót. Tipo Cargas Dirección

P1 P2 L1 (m) L2 (m) X Y Z

1/2 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

1/2 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

1/2 3 (V 1) Uniforme 0.147 t/m - - - 0.000 1.000 0.000

1/2 3 (V 1) Uniforme 0.175 t/m - - - -1.000 0.000 0.000

1/2 4 (V 2) Uniforme 0.147 t/m - - - 0.000 1.000 0.000

1/2 4 (V 2) Uniforme 0.175 t/m - - - -1.000 0.000 0.000

1/2 5 (V 3) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000

1/2 5 (V 3) Uniforme 0.117 t/m - - - 0.000 0.000 -1.000

1/2 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

1/2 6 (V 4) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000

1/2 6 (V 4) Uniforme 0.074 t/m - - - -1.000 0.000 0.000

1/2 7 (V 5) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000

1/2 7 (V 5) Uniforme 0.074 t/m - - - -1.000 0.000 0.000

1/2 8 (V 6) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000

1/2 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000

2/4 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

2/4 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

2/4 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

2/4 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995

2/4 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 2.010 3.769 0.000 -0.100 0.995

2/4 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995

2/4 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 2.010 3.769 0.000 0.100 -0.995

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

48/106

2/4 5 (V 3) Trapez. 0.342 t/m 0.342 t/m 0.000 3.769 0.000 -0.100 0.995

2/4 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

2/4 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

2/4 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

2/4 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

2/4 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

2/4 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

2/4 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

3/4 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

3/4 3 (V 1) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

3/4 4 (V 2) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

3/4 5 (V 3) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

3/4 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

3/4 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

3/4 8 (V 6) Uniforme 0.146 t/m - - - -1.000 0.000 0.000

4/6 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

4/6 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

4/6 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

4/6 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

4/6 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

4/6 5 (V 3) Trapez. 0.342 t/m 0.342 t/m 0.000 1.256 0.000 -0.100 0.995

4/6 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995

4/6 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

4/6 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

4/6 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

4/6 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

4/6 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

4/6 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

4/6 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

5/6 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

5/6 3 (V 1) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

5/6 4 (V 2) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

5/6 5 (V 3) Uniforme 0.273 t/m - - - 1.000 0.000 0.000

5/6 6 (V 4) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

5/6 7 (V 5) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

5/6 8 (V 6) Uniforme 0.170 t/m - - - -1.000 0.000 0.000

6/8 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

6/8 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

6/8 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

6/8 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 -0.100 0.995

6/8 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 0.100 -0.995

6/8 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 -0.100 0.995

6/8 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

6/8 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995

6/8 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995

6/8 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

6/8 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

49/106

6/8 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

6/8 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

7/8 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

7/8 3 (V 1) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

7/8 4 (V 2) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

7/8 5 (V 3) Uniforme 0.273 t/m - - - 1.000 0.000 0.000

7/8 6 (V 4) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

7/8 7 (V 5) Uniforme 0.295 t/m - - - -1.000 0.000 0.000

7/8 8 (V 6) Uniforme 0.170 t/m - - - -1.000 0.000 0.000

8/10 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

8/10 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

8/10 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

8/10 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

8/10 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

8/10 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 2.513 0.000 -0.100 0.995

8/10 5 (V 3) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995

8/10 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

8/10 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

8/10 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

8/10 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

8/10 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

8/10 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

8/10 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

9/10 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

9/10 3 (V 1) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

9/10 4 (V 2) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

9/10 5 (V 3) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

9/10 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

9/10 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

9/10 8 (V 6) Uniforme 0.146 t/m - - - -1.000 0.000 0.000

10/13 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

10/13 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

10/13 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

10/13 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

10/13 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

10/13 5 (V 3) Trapez. 0.351 t/m 0.351 t/m 0.000 3.769 0.000 -0.100 0.995

10/13 5 (V 3) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

10/13 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995

10/13 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995

10/13 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995

10/13 7 (V 5) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995

10/13 8 (V 6) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

10/13 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

10/13 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

10/13 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

11/12 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

11/12 3 (V 1) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

50/106

11/12 3 (V 1) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

11/12 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

11/12 4 (V 2) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

11/12 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

11/12 5 (V 3) Uniforme 0.156 t/m - - - 1.000 0.000 0.000

11/12 6 (V 4) Uniforme 0.156 t/m - - - -1.000 0.000 0.000

11/12 6 (V 4) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

11/12 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

11/12 7 (V 5) Uniforme 0.156 t/m - - - -1.000 0.000 0.000

11/12 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000

11/12 8 (V 6) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

12/13 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

12/13 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

12/13 3 (V 1) Faja 0.067 t/m - 0.000 3.000 0.000 1.000 0.000

12/13 3 (V 1) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

12/13 4 (V 2) Faja 0.067 t/m - 0.000 3.000 0.000 1.000 0.000

12/13 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

12/13 5 (V 3) Faja 0.248 t/m - 0.000 3.000 0.000 1.000 0.000

12/13 5 (V 3) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

12/13 6 (V 4) Faja 0.147 t/m - 0.000 3.000 0.000 -1.000 0.000

12/13 6 (V 4) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

12/13 7 (V 5) Faja 0.147 t/m - 0.000 3.000 0.000 -1.000 0.000

12/13 7 (V 5) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

12/13 8 (V 6) Faja 0.104 t/m - 0.000 3.000 0.000 1.000 0.000

12/13 8 (V 6) Uniforme 0.073 t/m - - - -1.000 0.000 0.000

15/12 1 (PP 1) Uniforme 0.019 t/m - - - 0.000 0.000 -1.000

15/12 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

15/12 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

15/12 3 (V 1) Uniforme 0.097 t/m - - - 0.000 0.100 0.995

15/12 4 (V 2) Uniforme 0.092 t/m - - - 0.000 0.100 0.995

15/12 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 0.000 0.000 0.100 0.995

15/12 5 (V 3) Trapez. 0.199 t/m 0.199 t/m 0.000 5.025 0.000 0.100 0.995

15/12 5 (V 3) Uniforme 0.029 t/m - - - 0.000 0.100 0.995

15/12 6 (V 4) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 0.100 0.995

15/12 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 -0.100 -0.995

15/12 8 (V 6) Uniforme 0.127 t/m - - - 0.000 0.100 0.995

15/12 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

15/12 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

15/12 11 (N 3) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

14/15 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

14/15 3 (V 1) Uniforme 0.194 t/m - - - -1.000 0.000 0.000

14/15 4 (V 2) Uniforme 0.194 t/m - - - -1.000 0.000 0.000

14/15 5 (V 3) Uniforme 0.312 t/m - - - 1.000 0.000 0.000

14/15 6 (V 4) Uniforme 0.312 t/m - - - -1.000 0.000 0.000

14/15 7 (V 5) Uniforme 0.312 t/m - - - -1.000 0.000 0.000

14/15 8 (V 6) Uniforme 0.195 t/m - - - -1.000 0.000 0.000

17/15 1 (PP 1) Uniforme 0.019 t/m - - - 0.000 0.000 -1.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

51/106

17/15 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

17/15 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

17/15 3 (V 1) Uniforme 0.097 t/m - - - 0.000 0.100 0.995

17/15 4 (V 2) Uniforme 0.092 t/m - - - 0.000 0.100 0.995

17/15 5 (V 3) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 0.100 0.995

17/15 5 (V 3) Uniforme 0.029 t/m - - - 0.000 0.100 0.995

17/15 6 (V 4) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 0.100 0.995

17/15 6 (V 4) Trapez. 0.120 t/m 0.120 t/m 2.010 5.025 0.000 0.100 0.995

17/15 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 -0.100 -0.995

17/15 7 (V 5) Trapez. 0.003 t/m 0.003 t/m 2.010 5.025 0.000 -0.100 -0.995

17/15 8 (V 6) Uniforme 0.127 t/m - - - 0.000 0.100 0.995

17/15 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

17/15 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

17/15 11 (N 3) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

16/17 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

16/17 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

16/17 3 (V 1) Uniforme 0.067 t/m - - - 0.000 1.000 0.000

16/17 3 (V 1) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

16/17 4 (V 2) Uniforme 0.067 t/m - - - 0.000 1.000 0.000

16/17 4 (V 2) Uniforme 0.097 t/m - - - -1.000 0.000 0.000

16/17 5 (V 3) Uniforme 0.248 t/m - - - 0.000 1.000 0.000

16/17 5 (V 3) Uniforme 0.156 t/m - - - 1.000 0.000 0.000

16/17 6 (V 4) Uniforme 0.147 t/m - - - 0.000 -1.000 0.000

16/17 6 (V 4) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

16/17 7 (V 5) Uniforme 0.147 t/m - - - 0.000 -1.000 0.000

16/17 7 (V 5) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

16/17 8 (V 6) Uniforme 0.104 t/m - - - 0.000 1.000 0.000

16/17 8 (V 6) Uniforme 0.097 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos

Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)

DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)

1 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

2 Envolvente (Desplazam.) -0.0166 -0.0174 0.0000 -0.0009 -0.0001 -0.0012

0.0165 0.0126 0.0000 0.0020 0.0013 0.0008

3 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

4 Envolvente (Desplazam.) -0.0290 -0.0174 -0.0001 -0.0007 -0.0024 -0.0008

0.0290 0.0126 0.0000 0.0009 0.0035 0.0010

5 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

6 Envolvente (Desplazam.) -0.0392 -0.0174 -0.0001 -0.0011 -0.0031 -0.0009

0.0392 0.0126 0.0000 0.0012 0.0055 0.0013

7 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

52/106

8 Envolvente (Desplazam.) -0.0439 -0.0174 -0.0001 -0.0005 -0.0030 -0.0009

0.0438 0.0126 0.0000 0.0010 0.0057 0.0013

9 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

10 Envolvente (Desplazam.) -0.0383 -0.0174 -0.0001 -0.0005 -0.0023 -0.0008

0.0383 0.0125 0.0000 0.0010 0.0037 0.0013

11 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

12 Envolvente (Desplazam.) -0.0277 -0.0126 -0.0001 -0.0016 -0.0015 -0.0026

0.0317 0.0083 0.0000 0.0020 0.0039 0.0021

13 Envolvente (Desplazam.) -0.0279 -0.0174 -0.0001 -0.0011 -0.0014 -0.0012

0.0281 0.0125 0.0000 0.0026 0.0024 0.0007

14 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

15 Envolvente (Desplazam.) -0.0327 -0.0126 -0.0001 -0.0003 -0.0056 -0.0012

0.0329 0.0083 0.0000 0.0005 0.0053 0.0011

16 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

17 Envolvente (Desplazam.) -0.0179 -0.0126 0.0000 -0.0013 -0.0019 -0.0016

0.0179 0.0083 0.0000 0.0023 0.0018 0.0017 4.- Reacciones

Nudos Descripción REACCIONES (EJES GENERALES)

RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)

1 Envolvente (Cim.equil.) -1.0133 -1.3468 -0.3702 -3.3526 -2.0415 -0.0004

1.1994 1.9378 1.5752 3.0297 1.7054 0.0005

1 Envolvente (Cim.tens.terr.) -0.6319 -0.8366 0.0774 -2.1158 -1.2721 -0.0002

0.7500 1.2193 1.0971 1.8811 1.0672 0.0003

3 Envolvente (Cim.equil.) -2.6256 -0.1827 -1.4646 -1.1935 -7.2631 -0.0006

2.2230 0.2623 2.5810 0.8414 6.5631 0.0006

3 Envolvente (Cim.tens.terr.) -1.5823 -0.1158 -0.4859 -0.7426 -4.3774 -0.0004

1.4512 0.1630 1.7918 0.5314 4.2728 0.0003

5 Envolvente (Cim.equil.) -3.1894 -0.1445 -1.8595 -1.0283 -9.1472 -0.0007

3.0257 0.2083 3.2866 0.7221 8.3312 0.0006

5 Envolvente (Cim.tens.terr.) -1.8997 -0.0878 -0.6358 -0.6536 -5.4465 -0.0005

1.9913 0.1341 2.2882 0.4446 5.4964 0.0003

7 Envolvente (Cim.equil.) -3.2627 -0.1484 -1.7565 -0.9908 -9.5802 -0.0007

3.0652 0.1986 3.2786 0.7284 8.6494 0.0006

7 Envolvente (Cim.tens.terr.) -1.9544 -0.0969 -0.5675 -0.6107 -5.7282 -0.0005

2.0065 0.1215 2.2807 0.4687 5.6834 0.0003

9 Envolvente (Cim.equil.) -2.7933 -0.1255 -1.2015 -0.8570 -8.2000 -0.0007

2.3400 0.1586 2.5938 0.6513 7.2232 0.0005

9 Envolvente (Cim.tens.terr.) -1.7006 -0.0784 -0.3071 -0.5369 -4.9806 -0.0004

1.5101 0.0996 1.7958 0.4078 4.6662 0.0003

11 Envolvente (Cim.equil.) -2.5198 -0.6373 -1.2796 -2.5612 -5.2961 -0.0017

2.2282 0.5350 2.3206 1.6913 3.8503 0.0020

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

53/106

11 Envolvente (Cim.tens.terr.) -1.5736 -0.3907 -0.3813 -1.6321 -3.3057 -0.0010

1.3930 0.3474 1.6003 1.0393 2.4081 0.0013

14 Envolvente (Cim.equil.) -2.9166 -0.2125 -1.8763 -1.0790 -7.3292 -0.0006

2.1593 0.3188 2.2232 0.7169 6.3515 0.0007

14 Envolvente (Cim.tens.terr.) -1.8092 -0.1325 -0.8397 -0.6766 -4.5539 -0.0004

1.3670 0.2000 1.5549 0.4477 4.0050 0.0004

16 Envolvente (Cim.equil.) -1.2293 -1.4045 -0.9106 -3.2037 -2.3615 -0.0010

1.3144 1.4098 1.4251 2.0338 2.0061 0.0010

16 Envolvente (Cim.tens.terr.) -0.7655 -0.8977 -0.3049 -1.9768 -1.4691 -0.0007

0.8227 0.8679 0.9804 1.3097 1.2576 0.0006 5.- Esfuerzos

Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)

0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L

1/2 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m

Envolvente (Acero laminado)

N- -1.4304 -1.2673 -1.1654 -1.0635 -0.9616 -0.8597 -0.7579 -0.6560 -0.5541

N+ 0.4603 0.5207 0.5810 0.6414 0.7018 0.7622 0.8226 0.9042 1.1262

Ty- -1.1242 -0.8617 -0.5992 -0.3582 -0.2397 -0.1302 -0.1051 -0.2806 -0.4561

Ty+ 0.9505 0.7750 0.5995 0.4240 0.2485 0.1913 0.4538 0.7163 0.9788

Tz- -1.8159 -1.4432 -1.0705 -0.6978 -0.3863 -0.2862 -0.1861 -0.3165 -0.5373

Tz+ 1.2645 1.0436 0.8228 0.6019 0.3811 0.1755 0.4446 0.8173 1.1900

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003

My- -3.1412 -1.7415 -1.1031 -0.5821 -0.6823 -0.9380 -0.9817 -0.7957 -0.6755

My+ 2.8450 1.6953 0.7583 0.6232 1.1416 1.2725 1.0458 0.5918 0.6140

Mz- -1.5983 -0.9218 -0.4061 -0.1510 -0.4825 -0.6398 -0.6285 -0.4347 -1.0188

Mz+ 1.9153 1.0561 0.3654 0.5896 0.7997 0.7369 0.5527 0.5164 0.3751

2/4 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.5658 -0.5555 -0.5453 -0.5350 -0.5247 -0.5145 -0.5042 -0.4942 -0.4896

N+ 1.2166 1.2198 1.2230 1.2262 1.2294 1.2326 1.2358 1.2395 1.2485

Ty- -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623 -0.0623

Ty+ 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493 0.0493

Tz- -0.4580 -0.3375 -0.2779 -0.2933 -0.3229 -0.4089 -0.4950 -0.6606 -0.8882

Tz+ 0.9323 0.7047 0.4772 0.2496 0.1710 0.2757 0.3805 0.4852 0.6019

Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003

Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004

My- -0.6136 -0.4934 -0.4177 -0.3256 -0.2686 -0.2090 -0.1407 -0.3213 -0.5736

My+ 0.6754 0.2920 0.2058 0.2014 0.1787 0.1375 0.2153 0.4449 0.7381

Mz- -0.1233 -0.0940 -0.0646 -0.0353 -0.0060 -0.0187 -0.0418 -0.0650 -0.0882

Mz+ 0.0976 0.0744 0.0512 0.0279 0.0047 0.0236 0.0528 0.0821 0.1114

3/4 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m

Envolvente (Acero laminado)

N- -2.3553 -2.2701 -2.1848 -2.0996 -2.0144 -1.9292 -1.8440 -1.7588 -1.6736

N+ 1.5306 1.5810 1.6315 1.6820 1.7325 1.7830 1.8335 1.8840 1.9345

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

54/106

Ty- -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463 -0.2463

Ty+ 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711 0.1711

Tz- -2.4831 -2.1156 -1.7481 -1.3807 -1.0132 -0.6458 -0.7219 -1.0893 -1.4568

Tz+ 2.0753 1.7244 1.4841 1.2548 1.0255 0.7963 0.5670 0.4046 0.6649

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005

My- -6.8686 -4.4692 -2.4391 -1.1896 -1.8760 -2.3097 -2.3742 -2.2218 -2.4765

My+ 6.1286 4.2198 2.5414 1.1911 0.4518 1.3125 1.8039 1.8952 1.9242

Mz- -1.1201 -0.8623 -0.6044 -0.3468 -0.0930 -0.1074 -0.2865 -0.4657 -0.6449

Mz+ 0.7884 0.6092 0.4302 0.2513 0.0781 0.1691 0.4270 0.6848 0.9427

4/6 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.4126 -0.4023 -0.3921 -0.3818 -0.3715 -0.3613 -0.3510 -0.3448 -0.3416

N+ 1.2326 1.2358 1.2390 1.2423 1.2455 1.2487 1.2519 1.2596 1.2698

Ty- -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466 -0.0466

Ty+ 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354 0.0354

Tz- -0.4550 -0.3345 -0.2210 -0.2093 -0.2407 -0.3411 -0.5305 -0.7280 -0.9254

Tz+ 0.7344 0.5068 0.2793 0.1689 0.1910 0.2958 0.4005 0.5053 0.6152

Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001

Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002

My- -0.3692 -0.2886 -0.2214 -0.2355 -0.2200 -0.1096 -0.1714 -0.3857 -0.6474

My+ 0.3852 0.2441 0.1886 0.1717 0.1244 0.1123 0.2321 0.4476 0.7798

Mz- -0.0849 -0.0629 -0.0410 -0.0190 -0.0024 -0.0191 -0.0358 -0.0525 -0.0692

Mz+ 0.0643 0.0476 0.0309 0.0143 0.0029 0.0248 0.0468 0.0687 0.0906

5/6 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m

Envolvente (Acero laminado)

N- -3.0022 -2.9132 -2.8242 -2.7351 -2.6461 -2.5571 -2.4681 -2.3791 -2.2900

N+ 1.9363 1.9891 2.0418 2.0946 2.1473 2.2001 2.2528 2.3056 2.3583

Ty- -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949 -0.1949

Ty+ 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364 0.1364

Tz- -3.0244 -2.5765 -2.1286 -1.6808 -1.2329 -0.7850 -0.9632 -1.4472 -1.9311

Tz+ 2.8226 2.3386 1.8546 1.5417 1.2628 0.9839 0.7104 0.6092 0.8949

Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006

Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007

My- -8.6747 -5.6215 -3.0386 -1.5792 -2.7122 -3.4067 -3.5931 -3.3247 -3.6528

My+ 7.7699 5.3272 3.1775 1.4768 0.6381 1.7318 2.3552 2.4691 2.7423

Mz- -0.9630 -0.7498 -0.5367 -0.3297 -0.1293 -0.0815 -0.2155 -0.3646 -0.5138

Mz+ 0.6794 0.5303 0.3813 0.2387 0.1020 0.1030 0.3161 0.5292 0.7424

6/8 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -0.3328 -0.3191 -0.3054 -0.2917 -0.2781 -0.2644 -0.2507 -0.2370 -0.2302

N+ 1.3577 1.3620 1.3663 1.3706 1.3748 1.3791 1.3834 1.3879 1.3993

Ty- -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128 -0.0128

Ty+ 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100 0.0100

Tz- -0.6420 -0.4814 -0.3207 -0.1608 -0.1282 -0.3049 -0.5681 -0.8314 -1.0946

Tz+ 1.0113 0.7481 0.4848 0.2216 0.0929 0.2324 0.3809 0.5432 0.7055

Mt- 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

55/106

Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

My- -0.5019 -0.2332 -0.2414 -0.4335 -0.4933 -0.3812 -0.1142 -0.3047 -0.6683

My+ 0.7248 0.2040 0.2077 0.2907 0.3085 0.2510 0.1399 0.3602 0.9341

Mz- -0.0301 -0.0221 -0.0141 -0.0061 -0.0020 -0.0064 -0.0127 -0.0190 -0.0253

Mz+ 0.0252 0.0189 0.0126 0.0062 0.0020 0.0100 0.0180 0.0260 0.0341

7/8 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m

Envolvente (Acero laminado)

N- -2.9942 -2.9001 -2.8059 -2.7118 -2.6177 -2.5236 -2.4295 -2.3354 -2.2413

N+ 1.8412 1.8969 1.9527 2.0085 2.0642 2.1200 2.1758 2.2315 2.2873

Ty- -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872 -0.1872

Ty+ 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387 0.1387

Tz- -3.0899 -2.6164 -2.1429 -1.6695 -1.1960 -0.7225 -0.9587 -1.4703 -1.9819

Tz+ 2.8609 2.3493 1.8376 1.5227 1.2278 0.9330 0.6432 0.5928 1.0020

Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006

Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006

My- -9.0766 -5.7885 -3.0261 -1.6190 -2.8483 -3.4822 -3.5483 -3.2084 -3.5841

My+ 8.0699 5.4638 3.1851 1.3852 0.8345 1.9327 2.5053 2.5085 2.6427

Mz- -0.9320 -0.7156 -0.4992 -0.2859 -0.0836 -0.1205 -0.2809 -0.4413 -0.6017

Mz+ 0.6816 0.5212 0.3608 0.2034 0.0570 0.1501 0.3665 0.5829 0.7993

8/10 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.2009 -0.1906 -0.1804 -0.1701 -0.1598 -0.1496 -0.1393 -0.1302 -0.1266

N+ 1.4960 1.4992 1.5024 1.5056 1.5088 1.5120 1.5152 1.5202 1.5300

Ty- -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245 -0.0245

Ty+ 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142 0.0142

Tz- -0.5085 -0.3880 -0.2675 -0.1967 -0.2082 -0.2787 -0.3962 -0.6304 -0.8646

Tz+ 0.8129 0.6155 0.4180 0.2206 0.1229 0.2123 0.3171 0.4218 0.5388

Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002

Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001

My- -0.3944 -0.2745 -0.1947 -0.1845 -0.2420 -0.2046 -0.0962 -0.2506 -0.4730

My+ 0.5457 0.2239 0.1353 0.1495 0.1354 0.1149 0.1975 0.3697 0.6015

Mz- -0.0492 -0.0376 -0.0261 -0.0145 -0.0030 -0.0061 -0.0128 -0.0195 -0.0262

Mz+ 0.0281 0.0217 0.0153 0.0089 0.0024 0.0086 0.0201 0.0316 0.0432

9/10 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m

Envolvente (Acero laminado)

N- -2.3651 -2.2672 -2.1693 -2.0713 -1.9734 -1.8755 -1.7776 -1.6797 -1.5817

N+ 1.2892 1.3472 1.4052 1.4633 1.5213 1.5793 1.6373 1.6954 1.7534

Ty- -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486 -0.1486

Ty+ 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177 0.1177

Tz- -2.6353 -2.2130 -1.7907 -1.3684 -0.9462 -0.5239 -0.7495 -1.1718 -1.5941

Tz+ 2.1870 1.7717 1.4835 1.2201 0.9566 0.6931 0.4296 0.4809 0.9031

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006

My- -7.7405 -4.8341 -2.4154 -1.3758 -2.1649 -2.4997 -2.3466 -2.4093 -2.4570

My+ 6.7500 4.4960 2.5463 0.9930 0.8774 1.7516 2.1380 1.9960 1.9194

Mz- -0.8034 -0.6248 -0.4467 -0.2689 -0.0916 -0.0976 -0.2391 -0.3807 -0.5223

Mz+ 0.6107 0.4693 0.3284 0.1876 0.0473 0.0941 0.2696 0.4485 0.6273

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

56/106

10/13 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.2149 -0.2046 -0.1944 -0.1841 -0.1738 -0.1636 -0.1533 -0.1448 -0.1413

N+ 1.6528 1.6560 1.6592 1.6624 1.6656 1.6688 1.6720 1.6778 1.6876

Ty- -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469 -0.0469

Ty+ 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347 0.0347

Tz- -0.4871 -0.3665 -0.2460 -0.1651 -0.2905 -0.5221 -0.7563 -1.0191 -1.3256

Tz+ 0.6490 0.4148 0.2074 0.1608 0.1848 0.2871 0.3918 0.4966 0.6013

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004

My- -0.2987 -0.1970 -0.2243 -0.2671 -0.2674 -0.1579 -0.2101 -0.3902 -0.6478

My+ 0.3003 0.1823 0.1636 0.1578 0.1649 0.1916 0.4122 0.7934 1.3130

Mz- -0.0858 -0.0638 -0.0417 -0.0197 -0.0022 -0.0177 -0.0340 -0.0504 -0.0667

Mz+ 0.0640 0.0477 0.0314 0.0151 0.0026 0.0247 0.0468 0.0688 0.0909

11/12 0.000 m 0.875 m 1.750 m 2.625 m 3.500 m 4.375 m 5.250 m 6.125 m 7.000 m

Envolvente (Acero laminado)

N- -2.1128 -2.0416 -1.9704 -1.8991 -1.8279 -1.7567 -1.6855 -1.6143 -1.5431

N+ 1.3531 1.3953 1.4375 1.4797 1.5219 1.5641 1.6063 1.6485 1.6907

Ty- -2.0887 -1.7304 -1.3721 -1.0138 -0.6796 -0.4565 -0.2334 -0.1478 -0.5061

Ty+ 2.3628 2.0044 1.6461 1.2878 0.9295 0.5712 0.2129 0.4468 0.8051

Tz- -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005 -0.5005

Tz+ 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003 0.6003

Mt- -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019 -0.0019

Mt+ 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016

My- -2.3984 -1.9605 -1.5226 -1.0944 -0.6978 -1.0341 -1.5593 -2.0846 -2.6098

My+ 1.5922 1.2136 0.9746 0.7455 0.5373 0.3305 0.2305 0.6669 1.1048

Mz- -3.6090 -2.3349 -1.2482 -0.3646 -0.7950 -1.4450 -1.7943 -1.8175 -1.5398

Mz+ 4.9667 3.0624 1.4590 0.6133 1.3260 1.7144 1.8029 1.5863 1.1484

12/13 0.000 m 0.375 m 0.750 m 1.125 m 1.500 m 1.875 m 2.250 m 2.625 m 3.000 m

Envolvente (Acero laminado)

N- -0.9180 -0.8748 -0.8316 -0.7885 -0.7453 -0.7021 -0.6589 -0.6158 -0.5726

N+ 1.7074 1.7330 1.7586 1.7842 1.8098 1.8354 1.8609 1.8865 1.9121

Ty- -0.5139 -0.5797 -0.6455 -0.7113 -0.7771 -0.8429 -0.9087 -0.9746 -1.0404

Ty+ 0.8025 0.8684 0.9342 1.0000 1.0658 1.1316 1.1974 1.2632 1.3290

Tz- -0.7561 -0.8511 -0.9908 -1.1306 -1.2703 -1.4101 -1.5499 -1.6896 -1.8294

Tz+ 0.3894 0.3519 0.3143 0.2768 0.2393 0.2018 0.1642 0.1267 0.0892

Mt- -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034 -0.0034

Mt+ 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055 0.0055

My- -2.6115 -2.3243 -1.9869 -1.5949 -1.1526 -0.6559 -0.5543 -0.6084 -0.6491

My+ 0.1820 0.2920 0.4965 0.6687 0.8111 0.9212 1.0014 1.0498 1.3136

Mz- -1.5399 -1.3356 -1.1075 -0.8537 -0.5763 -0.7969 -1.2331 -1.6950 -2.1805

Mz+ 1.1483 1.0569 0.9506 0.8284 0.6914 0.5383 0.3705 0.4223 0.7996

15/12 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -0.2592 -0.2453 -0.2313 -0.2174 -0.2035 -0.1895 -0.1756 -0.1616 -0.1477

N+ 1.2278 1.2322 1.2366 1.2411 1.2455 1.2499 1.2543 1.2588 1.2632

Ty- -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086 -0.0086

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

57/106

Ty+ 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103 0.0103

Tz- -0.6747 -0.5115 -0.3483 -0.2326 -0.1745 -0.2045 -0.2472 -0.3791 -0.5497

Tz+ 0.8153 0.6447 0.4741 0.3188 0.2452 0.3641 0.5063 0.6485 0.7907

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005

My- -0.5916 -0.2883 -0.1252 -0.2722 -0.4113 -0.4390 -0.4575 -0.7018 -1.1520

My+ 0.7798 0.4212 0.2205 0.2378 0.2887 0.2963 0.3459 0.4504 0.6454

Mz- -0.0362 -0.0308 -0.0258 -0.0210 -0.0161 -0.0112 -0.0064 -0.0015 -0.0050

Mz+ 0.0468 0.0403 0.0338 0.0274 0.0209 0.0144 0.0080 0.0030 0.0074

14/15 0.000 m 0.813 m 1.625 m 2.438 m 3.250 m 4.063 m 4.875 m 5.688 m 6.500 m

Envolvente (Acero laminado)

N- -2.0343 -1.9789 -1.9236 -1.8682 -1.8128 -1.7575 -1.7021 -1.6467 -1.5914

N+ 1.8811 1.9139 1.9467 1.9795 2.0124 2.0452 2.0780 2.1108 2.1436

Ty- -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988 -0.2988

Ty+ 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994 0.1994

Tz- -2.7393 -2.3590 -1.9788 -1.5985 -1.2183 -0.8380 -0.5007 -0.8810 -1.2612

Tz+ 2.0223 1.7846 1.5470 1.3093 1.0716 0.8340 0.5963 0.3587 0.3577

Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007

Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006

My- -6.8810 -4.8160 -3.0476 -1.6250 -1.2670 -1.4329 -1.3022 -0.9225 -1.0152

My+ 5.9505 4.4078 3.0505 1.9180 0.9916 0.4540 0.9118 1.1231 1.0378

Mz- -1.0114 -0.7686 -0.5259 -0.2832 -0.0507 -0.1376 -0.2995 -0.4614 -0.6234

Mz+ 0.6725 0.5105 0.3485 0.1866 0.0256 0.2025 0.4452 0.6880 0.9308

17/15 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -0.1798 -0.1635 -0.1472 -0.1308 -0.1145 -0.0985 -0.0843 -0.0704 -0.0565

N+ 1.0654 1.0698 1.0742 1.0787 1.0831 1.0875 1.0919 1.0964 1.1008

Ty- -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234 -0.0234

Ty+ 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223 0.0223

Tz- -0.6183 -0.4551 -0.2919 -0.1958 -0.1634 -0.2975 -0.5629 -0.8283 -1.0937

Tz+ 1.0294 0.7640 0.4986 0.2413 0.2544 0.3966 0.5388 0.6810 0.8295

Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004

Mt+ 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005

My- -0.6136 -0.4089 -0.3211 -0.3958 -0.4622 -0.3554 -0.1601 -0.4967 -0.9673

My+ 1.0257 0.5386 0.5274 0.4998 0.3864 0.2359 0.1243 0.3518 0.9521

Mz- -0.0557 -0.0410 -0.0263 -0.0126 -0.0074 -0.0144 -0.0284 -0.0424 -0.0564

Mz+ 0.0556 0.0416 0.0276 0.0136 0.0039 0.0177 0.0324 0.0470 0.0617

16/17 0.000 m 0.750 m 1.500 m 2.250 m 3.000 m 3.750 m 4.500 m 5.250 m 6.000 m

Envolvente (Acero laminado)

N- -1.2964 -1.2200 -1.1435 -1.0671 -0.9907 -0.9143 -0.8379 -0.7615 -0.6850

N+ 0.9506 0.9959 1.0412 1.0865 1.1317 1.1770 1.2223 1.2676 1.3129

Ty- -1.2318 -0.9685 -0.7053 -0.5267 -0.4176 -0.3085 -0.1994 -0.1140 -0.2563

Ty+ 1.1535 0.9780 0.8025 0.6270 0.4515 0.2760 0.3535 0.6168 0.8800

Tz- -1.3266 -1.1609 -0.9953 -0.8297 -0.6640 -0.4984 -0.4235 -0.7030 -0.9825

Tz+ 1.3147 1.0352 0.7557 0.5058 0.4194 0.3444 0.2693 0.1942 0.1285

Mt- -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010 -0.0010

Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

58/106

My- -3.0128 -2.1341 -1.3747 -0.7653 -0.5459 -0.5839 -0.4207 -0.4950 -0.6136

My+ 1.9028 1.3924 0.9360 0.5576 0.2594 0.4610 0.7751 0.9601 1.0258

Mz- -1.8797 -1.2816 -0.7622 -0.3278 -0.1922 -0.4613 -0.6051 -0.6120 -0.4926

Mz+ 2.2164 1.4197 0.7494 0.4747 0.7093 0.7397 0.5815 0.5976 0.6260 6.- Tensiones

Barras TENSIÓN MÁXIMA

TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)

1/2 0.7818 78.18 0.000 -1.4019 0.9479 -1.8159 0.0002 -3.1412 1.9083

2/4 0.4696 46.96 0.000 0.0096 0.0175 -0.2470 0.0001 -0.6136 0.0345

3/4 0.5489 54.89 0.000 -1.6258 -0.0209 1.9425 0.0005 6.1281 -0.1113

4/6 0.4699 46.99 3.769 -0.3301 -0.0113 0.6101 0.0002 -0.6474 0.0219

5/6 0.7132 71.32 0.000 -1.7859 -0.0300 2.3784 0.0002 7.7699 -0.1351

6/8 0.6225 62.25 5.025 -0.2228 -0.0073 0.6514 0.0000 -0.6683 0.0182

7/8 0.7610 76.10 0.000 -1.8425 -0.0138 2.4072 0.0000 8.0699 -0.0838

8/10 0.3446 34.46 3.769 -0.1183 -0.0115 0.5266 -0.0002 -0.4730 0.0209

9/10 0.6683 66.83 0.000 -1.7880 -0.0286 2.0105 -0.0003 6.7500 -0.1290

10/13 0.5218 52.18 3.769 1.6784 0.0341 -1.2247 -0.0004 1.3130 -0.0652

11/12 0.9215 92.15 0.000 0.1153 2.3608 0.5871 -0.0007 1.5630 4.9597

12/13 0.4240 42.40 3.000 1.9121 1.3290 -0.0936 0.0014 1.0948 -2.1805

15/12 0.7309 73.09 5.025 0.2313 -0.0041 0.7907 -0.0002 -1.1520 0.0040

14/15 0.6144 61.44 0.000 -0.8330 0.0157 2.0223 -0.0003 5.9505 0.0706

17/15 0.6330 63.30 5.025 -0.0560 0.0092 0.8232 0.0000 -0.9673 -0.0278

16/17 0.6256 62.56 0.000 0.3106 1.1477 1.3147 0.0009 1.7221 2.2002

Resultados de cálculo en pórtico hastial trasero 1.- Barras: Descripción

Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.

(kp) (m³) (m) (m) (m)

75/76 Acero (S275) HE 220 A (HEA) 403.80 0.051 8.00 0.70 1.33 8.00 8.00

76/78 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

77/78 Acero (S275) HE 240 A (HEA) 504.91 0.064 8.38 0.70 1.30 8.38 -

78/80 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

79/80 Acero (S275) HE 240 A (HEA) 527.52 0.067 8.75 0.70 1.30 8.75 -

80/82 Acero (S275) IPE 160 (IPE) 79.29 0.010 5.02 0.05 0.73 1.00 5.02

81/82 Acero (S275) HE 240 A (HEA) 557.66 0.071 9.25 0.70 1.30 9.25 -

82/84 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

83/84 Acero (S275) HE 240 A (HEA) 580.27 0.074 9.63 0.70 1.30 9.63 -

84/86 Acero (S275) IPE 160 (IPE) 59.46 0.008 3.77 0.05 0.73 1.00 3.77

85/86 Acero (S275) HE 240 A (HEA) 602.88 0.077 10.00 0.70 1.22 10.00 10.00

2.- Cargas (Barras)

Barras Hipót. Tipo Cargas Dirección

P1 P2 L1 (m) L2 (m) X Y Z

75/76 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

59/106

75/76 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

75/76 3 (V 1) Uniforme 0.147 t/m - - - 0.000 1.000 0.000

75/76 3 (V 1) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

75/76 4 (V 2) Uniforme 0.147 t/m - - - 0.000 1.000 0.000

75/76 4 (V 2) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

75/76 5 (V 3) Uniforme 0.104 t/m - - - 0.000 -1.000 0.000

75/76 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000

75/76 6 (V 4) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000

75/76 6 (V 4) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

75/76 7 (V 5) Uniforme 0.067 t/m - - - 0.000 -1.000 0.000

75/76 7 (V 5) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

75/76 8 (V 6) Uniforme 0.248 t/m - - - 0.000 -1.000 0.000

75/76 8 (V 6) Uniforme 0.117 t/m - - - -1.000 0.000 0.000

76/78 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

76/78 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

76/78 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

76/78 3 (V 1) Trapez. 0.340 t/m 0.340 t/m 0.000 2.010 0.000 -0.100 0.995

76/78 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 2.010 3.769 0.000 -0.100 0.995

76/78 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 2.010 0.000 0.100 -0.995

76/78 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 2.010 3.769 0.000 0.100 -0.995

76/78 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

76/78 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

76/78 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

76/78 8 (V 6) Trapez. 0.342 t/m 0.342 t/m 0.000 3.769 0.000 -0.100 0.995

76/78 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

76/78 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

76/78 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

76/78 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

77/78 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

77/78 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

77/78 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

77/78 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000

77/78 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

77/78 7 (V 5) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

77/78 8 (V 6) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

78/80 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

78/80 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

78/80 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

78/80 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

78/80 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

78/80 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

78/80 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

78/80 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

78/80 8 (V 6) Trapez. 0.342 t/m 0.342 t/m 0.000 1.256 0.000 -0.100 0.995

78/80 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 1.256 3.769 0.000 -0.100 0.995

78/80 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

78/80 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

60/106

78/80 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

78/80 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

79/80 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

79/80 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

79/80 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

79/80 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000

79/80 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

79/80 7 (V 5) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

79/80 8 (V 6) Uniforme 0.273 t/m - - - -1.000 0.000 0.000

80/82 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

80/82 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

80/82 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

80/82 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 5.025 0.000 -0.100 0.995

80/82 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 5.025 0.000 0.100 -0.995

80/82 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

80/82 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995

80/82 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 5.025 0.000 -0.100 0.995

80/82 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 0.000 5.025 0.000 -0.100 0.995

80/82 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

80/82 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

80/82 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

80/82 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

81/82 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

81/82 3 (V 1) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

81/82 4 (V 2) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

81/82 5 (V 3) Uniforme 0.170 t/m - - - 1.000 0.000 0.000

81/82 6 (V 4) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

81/82 7 (V 5) Uniforme 0.295 t/m - - - 1.000 0.000 0.000

81/82 8 (V 6) Uniforme 0.273 t/m - - - -1.000 0.000 0.000

82/84 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

82/84 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

82/84 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

82/84 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

82/84 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

82/84 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

82/84 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

82/84 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 3.769 0.000 -0.100 0.995

82/84 8 (V 6) Trapez. 0.299 t/m 0.299 t/m 0.000 2.513 0.000 -0.100 0.995

82/84 8 (V 6) Trapez. 0.351 t/m 0.351 t/m 2.513 3.769 0.000 -0.100 0.995

82/84 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

82/84 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

82/84 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

82/84 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

83/84 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

83/84 3 (V 1) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

83/84 4 (V 2) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

83/84 5 (V 3) Uniforme 0.146 t/m - - - 1.000 0.000 0.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

61/106

83/84 6 (V 4) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

83/84 7 (V 5) Uniforme 0.234 t/m - - - 1.000 0.000 0.000

83/84 8 (V 6) Uniforme 0.234 t/m - - - -1.000 0.000 0.000

84/86 1 (PP 1) Uniforme 0.016 t/m - - - 0.000 0.000 -1.000

84/86 1 (PP 1) Uniforme 0.070 t/m - - - 0.000 0.000 -1.000

84/86 2 (SC 1) Uniforme 0.063 t/m - - - 0.000 0.000 -1.000

84/86 3 (V 1) Trapez. 0.120 t/m 0.120 t/m 0.000 3.769 0.000 -0.100 0.995

84/86 4 (V 2) Trapez. 0.003 t/m 0.003 t/m 0.000 3.769 0.000 0.100 -0.995

84/86 5 (V 3) Uniforme 0.106 t/m - - - 0.000 -0.100 0.995

84/86 6 (V 4) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995

84/86 6 (V 4) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995

84/86 7 (V 5) Trapez. 0.167 t/m 0.167 t/m 0.000 1.759 0.000 -0.100 0.995

84/86 7 (V 5) Trapez. 0.479 t/m 0.479 t/m 1.759 3.769 0.000 -0.100 0.995

84/86 8 (V 6) Trapez. 0.351 t/m 0.351 t/m 0.000 3.769 0.000 -0.100 0.995

84/86 8 (V 6) Uniforme 0.025 t/m - - - 0.000 -0.100 0.995

84/86 9 (N 1) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

84/86 10 (N 2) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

84/86 11 (N 3) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

85/86 1 (PP 1) Uniforme 0.060 t/m - - - 0.000 0.000 -1.000

85/86 1 (PP 1) Uniforme 0.025 t/m - - - 0.000 0.000 -1.000

85/86 3 (V 1) Faja 0.067 t/m - 0.000 10.000 0.000 1.000 0.000

85/86 3 (V 1) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

85/86 4 (V 2) Faja 0.067 t/m - 0.000 10.000 0.000 1.000 0.000

85/86 4 (V 2) Uniforme 0.117 t/m - - - 1.000 0.000 0.000

85/86 5 (V 3) Faja 0.104 t/m - 0.000 10.000 0.000 1.000 0.000

85/86 5 (V 3) Uniforme 0.073 t/m - - - 1.000 0.000 0.000

85/86 6 (V 4) Faja 0.147 t/m - 0.000 10.000 0.000 -1.000 0.000

85/86 6 (V 4) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

85/86 7 (V 5) Faja 0.147 t/m - 0.000 10.000 0.000 -1.000 0.000

85/86 7 (V 5) Uniforme 0.175 t/m - - - 1.000 0.000 0.000

85/86 8 (V 6) Faja 0.248 t/m - 0.000 10.000 0.000 1.000 0.000

85/86 8 (V 6) Uniforme 0.117 t/m - - - -1.000 0.000 0.000 3.- Desplazamientos

Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)

DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)

75 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

76 Envolvente (Desplazam.) -0.0167 -0.0269 0.0000 -0.0016 -0.0013 -0.0012

0.0165 0.0175 0.0000 0.0032 0.0001 0.0016

77 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

78 Envolvente (Desplazam.) -0.0291 -0.0270 -0.0001 -0.0009 -0.0036 -0.0013

0.0289 0.0174 0.0000 0.0014 0.0024 0.0012

79 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

62/106

80 Envolvente (Desplazam.) -0.0394 -0.0270 -0.0001 -0.0014 -0.0057 -0.0017

0.0391 0.0174 0.0000 0.0018 0.0031 0.0013

81 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

82 Envolvente (Desplazam.) -0.0440 -0.0270 -0.0001 -0.0008 -0.0058 -0.0017

0.0437 0.0174 0.0000 0.0015 0.0030 0.0013

83 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

84 Envolvente (Desplazam.) -0.0384 -0.0270 -0.0001 -0.0008 -0.0037 -0.0015

0.0382 0.0174 0.0000 0.0015 0.0023 0.0010

85 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

86 Envolvente (Desplazam.) -0.0278 -0.0271 -0.0001 -0.0011 -0.0018 -0.0012

0.0279 0.0174 0.0000 0.0031 0.0003 0.0016 4.- Reacciones

Nudos Descripción REACCIONES (EJES GENERALES)

RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)

75 Envolvente (Cim.equil.) -1.2040 -1.4415 -0.5134 -3.6735 -1.7237 -0.0007

1.0151 1.9811 1.5073 3.5562 2.0497 0.0006

75 Envolvente (Cim.tens.terr.) -0.7528 -0.8959 -0.0124 -2.3149 -1.0781 -0.0005

0.6331 1.2461 1.0274 2.2108 1.2777 0.0004

77 Envolvente (Cim.equil.) -2.2410 -0.2565 -1.4915 -1.8512 -6.5379 -0.0008

2.6275 0.4072 2.5847 1.1765 7.2687 0.0008

77 Envolvente (Cim.tens.terr.) -1.4625 -0.1619 -0.5021 -1.1533 -4.2551 -0.0005

1.5834 0.2534 1.7944 0.7406 4.3823 0.0005

79 Envolvente (Cim.equil.) -3.0395 -0.2037 -1.8703 -1.5980 -8.3168 -0.0009

3.1869 0.3241 3.3022 1.0132 9.1372 0.0010

79 Envolvente (Cim.tens.terr.) -2.0004 -0.1249 -0.6406 -1.0089 -5.4862 -0.0005

1.8977 0.2063 2.2998 0.6269 5.4413 0.0007

81 Envolvente (Cim.equil.) -3.0747 -0.2003 -1.7460 -1.5136 -8.6458 -0.0008

3.2589 0.3005 3.3022 0.9947 9.5684 0.0009

81 Envolvente (Cim.tens.terr.) -2.0134 -0.1293 -0.5576 -0.9370 -5.6814 -0.0005

1.9510 0.1851 2.2976 0.6351 5.7205 0.0006

83 Envolvente (Cim.equil.) -2.3445 -0.1712 -1.1706 -1.3372 -7.2337 -0.0006

2.7895 0.2481 2.6319 0.8957 8.1853 0.0008

83 Envolvente (Cim.tens.terr.) -1.5138 -0.1067 -0.2824 -0.8368 -4.6738 -0.0004

1.6973 0.1556 1.8234 0.5594 4.9703 0.0005

85 Envolvente (Cim.equil.) -1.5581 -2.2233 -0.9660 -5.6258 -2.9645 -0.0008

1.2657 1.8581 1.8838 3.7075 3.1750 0.0007

85 Envolvente (Cim.tens.terr.) -0.9741 -1.3971 -0.2014 -3.4987 -1.8535 -0.0005

0.7900 1.1564 1.2784 2.3435 1.9809 0.0004 5.- Esfuerzos

Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

63/106

0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L

75/76 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m

Envolvente (Acero laminado)

N- -1.3668 -1.2649 -1.1630 -1.0611 -0.9592 -0.8573 -0.7554 -0.6536 -0.5517

N+ 0.5944 0.6548 0.7152 0.7756 0.8360 0.8963 0.9567 1.0171 1.0775

Ty- -0.9521 -0.7766 -0.6011 -0.4256 -0.2501 -0.1879 -0.4504 -0.7129 -0.9754

Ty+ 1.1285 0.8660 0.6035 0.3593 0.2374 0.1279 0.1030 0.2785 0.4540

Tz- -1.8566 -1.4839 -1.1112 -0.7385 -0.5601 -0.4600 -0.3599 -0.2946 -0.4861

Tz+ 1.3532 1.1324 0.9115 0.6907 0.4698 0.2490 0.4035 0.7762 1.1489

Mt- -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005 -0.0005

Mt+ 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007

My- -3.4421 -2.5338 -1.7216 -1.0280 -0.6032 -0.9097 -1.0041 -0.8688 -0.5739

My+ 3.3383 2.0999 1.0735 0.5457 1.0786 1.2506 1.0649 0.8266 1.0384

Mz- -1.9228 -1.0620 -0.3697 -0.5848 -0.7987 -0.7407 -0.5485 -0.5100 -0.3663

Mz+ 1.6155 0.9144 0.4011 0.1485 0.4817 0.6406 0.6310 0.4388 1.0069

76/78 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.4782 -0.4679 -0.4576 -0.4474 -0.4371 -0.4268 -0.4166 -0.4063 -0.4016

N+ 1.1684 1.1716 1.1748 1.1780 1.1812 1.1844 1.1876 1.1909 1.1997

Ty- -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520 -0.0520

Ty+ 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648 0.0648

Tz- -0.4878 -0.4563 -0.4717 -0.4871 -0.5173 -0.6033 -0.6893 -0.7754 -0.9347

Tz+ 0.8858 0.6582 0.4307 0.2382 0.2699 0.3747 0.4794 0.5842 0.6889

Mt- -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004 -0.0004

Mt+ 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003

My- -1.0379 -0.8264 -0.6601 -0.4764 -0.2538 -0.2184 -0.2038 -0.4310 -0.7299

My+ 0.5738 0.3567 0.3291 0.2750 0.1915 0.1478 0.3389 0.6604 1.0452

Mz- -0.1026 -0.0781 -0.0536 -0.0293 -0.0050 -0.0248 -0.0553 -0.0858 -0.1164

Mz+ 0.1279 0.0973 0.0668 0.0365 0.0062 0.0199 0.0444 0.0690 0.0935

77/78 0.000 m 1.047 m 2.094 m 3.141 m 4.188 m 5.234 m 6.281 m 7.328 m 8.375 m

Envolvente (Acero laminado)

N- -2.3587 -2.2735 -2.1883 -2.1031 -2.0179 -1.9327 -1.8474 -1.7622 -1.6770

N+ 1.5559 1.6064 1.6569 1.7074 1.7579 1.8084 1.8589 1.9094 1.9599

Ty- -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821 -0.3821

Ty+ 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403 0.2403

Tz- -2.0922 -1.7297 -1.4779 -1.2486 -1.0193 -0.7901 -0.5608 -0.4025 -0.6633

Tz+ 2.4848 2.1174 1.7499 1.3825 1.0150 0.6476 0.7088 1.0763 1.4437

Mt- -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007 -0.0007

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -6.1052 -4.2028 -2.5309 -1.1937 -0.4545 -1.3170 -1.8103 -1.9035 -1.9876

My+ 6.8733 4.4720 2.4400 1.2049 1.9147 2.3661 2.4482 2.2501 2.4659

Mz- -1.7369 -1.3368 -0.9368 -0.5368 -0.1408 -0.1554 -0.4069 -0.6585 -0.9101

Mz+ 1.1024 0.8509 0.5993 0.3478 0.1003 0.2634 0.6634 1.0635 1.4635

78/80 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.3933 -0.3830 -0.3727 -0.3625 -0.3522 -0.3419 -0.3317 -0.3239 -0.3207

N+ 1.1500 1.1532 1.1564 1.1596 1.1628 1.1660 1.1692 1.1750 1.1853

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

64/106

Ty- -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378 -0.0378

Ty+ 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498 0.0498

Tz- -0.4542 -0.3445 -0.3122 -0.3276 -0.3593 -0.4453 -0.5579 -0.7553 -0.9528

Tz+ 0.7070 0.4795 0.2561 0.2109 0.2515 0.3562 0.4610 0.5657 0.6705

Mt- -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002 -0.0002

Mt+ 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001

My- -0.5823 -0.4460 -0.3234 -0.2459 -0.2175 -0.1202 -0.2333 -0.4761 -0.7663

My+ 0.4474 0.2984 0.2406 0.1951 0.1226 0.1713 0.3537 0.6251 0.9354

Mz- -0.0688 -0.0509 -0.0331 -0.0153 -0.0030 -0.0264 -0.0499 -0.0733 -0.0968

Mz+ 0.0909 0.0674 0.0439 0.0205 0.0025 0.0204 0.0382 0.0560 0.0738

79/80 0.000 m 1.094 m 2.187 m 3.281 m 4.375 m 5.469 m 6.562 m 7.656 m 8.750 m

Envolvente (Acero laminado)

N- -3.0165 -2.9275 -2.8385 -2.7495 -2.6604 -2.5714 -2.4824 -2.3934 -2.3044

N+ 1.9472 1.9999 2.0527 2.1054 2.1582 2.2109 2.2637 2.3164 2.3692

Ty- -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035 -0.3035

Ty+ 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918 0.1918

Tz- -2.8354 -2.3514 -1.8674 -1.5390 -1.2601 -0.9812 -0.7103 -0.6127 -0.8988

Tz+ 3.0223 2.5744 2.1265 1.6786 1.2307 0.7828 0.9517 1.4357 1.9197

Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009

Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009

My- -7.7566 -5.3168 -3.1698 -1.4822 -0.6385 -1.7298 -2.3508 -2.4624 -2.8125

My+ 8.6649 5.6140 3.0335 1.5989 2.7560 3.4643 3.6646 3.3998 3.6628

Mz- -1.4972 -1.1652 -0.8333 -0.5081 -0.1887 -0.1043 -0.3065 -0.5163 -0.7261

Mz+ 0.9522 0.7424 0.5326 0.3295 0.1322 0.1624 0.4943 0.8263 1.1582

80/82 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -0.5451 -0.5314 -0.5177 -0.5040 -0.4903 -0.4766 -0.4629 -0.4492 -0.4399

N+ 1.2461 1.2504 1.2547 1.2589 1.2632 1.2675 1.2718 1.2760 1.2847

Ty- -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158 -0.0158

Ty+ 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148 0.0148

Tz- -0.6417 -0.4810 -0.3204 -0.1903 -0.1994 -0.3329 -0.5853 -0.8485 -1.1118

Tz+ 0.9942 0.7309 0.4677 0.2044 0.1290 0.2686 0.4083 0.5649 0.7272

Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001

Mt+ 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

My- -0.5130 -0.3670 -0.3352 -0.4448 -0.4939 -0.3709 -0.1389 -0.3707 -0.7570

My+ 0.6812 0.2252 0.2554 0.3096 0.3099 0.2510 0.2249 0.4724 0.9767

Mz- -0.0399 -0.0300 -0.0201 -0.0101 -0.0020 -0.0113 -0.0206 -0.0298 -0.0391

Mz+ 0.0352 0.0259 0.0166 0.0073 0.0020 0.0097 0.0197 0.0296 0.0396

81/82 0.000 m 1.156 m 2.312 m 3.469 m 4.625 m 5.781 m 6.937 m 8.094 m 9.250 m

Envolvente (Acero laminado)

N- -3.0158 -2.9217 -2.8275 -2.7334 -2.6393 -2.5452 -2.4511 -2.3570 -2.2629

N+ 1.8326 1.8884 1.9441 1.9999 2.0557 2.1114 2.1672 2.2230 2.2787

Ty- -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827 -0.2827

Ty+ 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874 0.1874

Tz- -2.8696 -2.3580 -1.8463 -1.5244 -1.2295 -0.9347 -0.6470 -0.5993 -1.0089

Tz+ 3.0866 2.6132 2.1397 1.6662 1.1927 0.7192 0.9147 1.4263 1.9379

Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

65/106

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -8.0665 -5.4585 -3.1777 -1.3870 -0.8303 -1.9247 -2.4935 -2.4930 -2.5658

My+ 9.0657 5.7814 3.0227 1.6040 2.8631 3.5070 3.5830 3.2462 3.6204

Mz- -1.4223 -1.0954 -0.7686 -0.4445 -0.1321 -0.1520 -0.3686 -0.5852 -0.8019

Mz+ 0.9312 0.7146 0.4979 0.2841 0.0819 0.2120 0.5388 0.8657 1.1925

82/84 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.6600 -0.6498 -0.6395 -0.6292 -0.6190 -0.6087 -0.5984 -0.5882 -0.5828

N+ 1.3574 1.3606 1.3638 1.3670 1.3702 1.3735 1.3767 1.3799 1.3880

Ty- -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286 -0.0286

Ty+ 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224 0.0224

Tz- -0.5063 -0.3858 -0.3051 -0.3078 -0.3232 -0.3949 -0.4810 -0.6525 -0.8867

Tz+ 0.7908 0.5934 0.3960 0.2051 0.1811 0.2716 0.3764 0.4811 0.5859

Mt- -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001 -0.0001

Mt+ 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002

My- -0.5644 -0.4374 -0.3034 -0.2235 -0.2465 -0.1987 -0.1505 -0.3347 -0.5851

My+ 0.4996 0.2528 0.1908 0.1771 0.1344 0.1482 0.3056 0.5345 0.8210

Mz- -0.0553 -0.0419 -0.0284 -0.0150 -0.0025 -0.0076 -0.0181 -0.0287 -0.0392

Mz+ 0.0451 0.0346 0.0240 0.0135 0.0030 0.0120 0.0254 0.0389 0.0523

83/84 0.000 m 1.203 m 2.406 m 3.609 m 4.813 m 6.016 m 7.219 m 8.422 m 9.625 m

Envolvente (Acero laminado)

N- -2.4000 -2.3021 -2.2042 -2.1063 -2.0084 -1.9104 -1.8125 -1.7146 -1.6167

N+ 1.2622 1.3202 1.3782 1.4363 1.4943 1.5523 1.6104 1.6684 1.7264

Ty- -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326 -0.2326

Ty+ 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606 0.1606

Tz- -2.1911 -1.7759 -1.4878 -1.2243 -0.9608 -0.6973 -0.4338 -0.4875 -0.9098

Tz+ 2.6321 2.2098 1.7875 1.3652 0.9429 0.5206 0.6701 1.0924 1.5147

Mt- -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008 -0.0008

Mt+ 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006

My- -6.7598 -4.5006 -2.5458 -0.9958 -0.8752 -1.7454 -2.1279 -1.9819 -1.6009

My+ 7.7271 4.8245 2.4098 1.2933 2.1611 2.5006 2.3524 2.4353 2.4881

Mz- -1.2535 -0.9737 -0.6947 -0.4168 -0.1388 -0.1263 -0.3195 -0.5127 -0.7059

Mz+ 0.8398 0.6466 0.4542 0.2628 0.0715 0.1455 0.4253 0.7051 0.9849

84/86 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -0.7221 -0.7119 -0.7016 -0.6913 -0.6811 -0.6708 -0.6605 -0.6503 -0.6437

N+ 1.4849 1.4881 1.4913 1.4945 1.4977 1.5009 1.5041 1.5073 1.5143

Ty- -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345 -0.0345

Ty+ 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442 0.0442

Tz- -0.4969 -0.3764 -0.2559 -0.2024 -0.3420 -0.5675 -0.8017 -1.0630 -1.3696

Tz+ 0.6036 0.3694 0.2212 0.1833 0.2149 0.3109 0.4157 0.5204 0.6252

Mt- -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003 -0.0003

Mt+ 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004

My- -0.3489 -0.3122 -0.3141 -0.3341 -0.3127 -0.1715 -0.2235 -0.4009 -0.6698

My+ 0.3389 0.2422 0.2090 0.1867 0.1746 0.2308 0.4862 0.8772 1.4181

Mz- -0.0614 -0.0453 -0.0295 -0.0141 -0.0024 -0.0232 -0.0440 -0.0649 -0.0857

Mz+ 0.0808 0.0601 0.0394 0.0187 0.0036 0.0199 0.0361 0.0524 0.0686

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

66/106

85/86 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m

Envolvente (Acero laminado)

N- -1.7057 -1.5617 -1.4178 -1.2739 -1.1300 -0.9861 -0.8421 -0.6982 -0.5543

N+ 1.0531 1.1384 1.2237 1.3090 1.3943 1.4796 1.5648 1.6501 1.7354

Ty- -1.1870 -0.9676 -0.7483 -0.5289 -0.3095 -0.2057 -0.5338 -0.8619 -1.1900

Ty+ 1.4606 1.1325 0.8043 0.4762 0.2934 0.1565 0.1310 0.3504 0.5697

Tz- -1.7437 -1.4677 -1.1916 -0.9156 -0.6395 -0.3902 -0.7343 -1.2002 -1.6660

Tz+ 2.0836 1.6178 1.1519 0.6861 0.3517 0.2266 0.1016 0.2140 0.4901

Mt- -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006 -0.0006

Mt+ 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008

My- -5.2806 -3.2804 -1.6114 -1.7088 -2.2866 -2.2591 -1.6725 -0.7755 -0.6710

My+ 3.4731 1.8625 1.0288 0.3632 0.6827 1.2996 1.5861 1.5159 1.4188

Mz- -2.9778 -1.6368 -0.5590 -0.8810 -1.2496 -1.2147 -0.8507 -0.7862 -0.5575

Mz+ 2.7787 1.4141 0.6164 0.2354 0.7635 1.0078 0.9888 0.6847 1.4228 6.- Tensiones

Barras TENSIÓN MÁXIMA

TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)

75/76 0.7814 78.14 0.000 -0.0454 -0.9500 -1.8566 -0.0003 -3.3662 -1.9174

76/78 0.7635 76.35 0.000 -0.1712 -0.0283 -0.4409 0.0000 -1.0379 -0.0560

77/78 0.6399 63.99 0.000 1.5559 -0.1057 2.4848 0.0000 6.8733 -0.4889

78/80 0.5601 56.01 3.769 -0.1924 0.0184 0.6705 -0.0002 -0.7663 -0.0356

79/80 0.7823 78.23 0.000 1.9472 -0.0564 3.0223 -0.0002 8.6649 -0.3408

80/82 0.7042 70.42 5.025 -0.0429 0.0105 0.6877 0.0000 -0.7570 -0.0261

81/82 0.8677 86.77 0.000 1.8326 -0.1026 3.0866 -0.0005 9.0657 -0.4718

82/84 0.4471 44.71 0.000 -0.6600 -0.0275 -0.2616 0.0000 -0.5644 -0.0531

83/84 0.7622 76.22 0.000 1.2622 -0.0837 2.6321 -0.0007 7.7271 -0.4106

84/86 0.5465 54.65 3.769 1.5105 -0.0325 -1.2701 0.0003 1.4181 0.0625

85/86 0.9403 94.03 0.000 0.4195 1.4605 -1.7365 0.0008 -5.2550 2.7787

Resultados de cálculo en pórtico intermedio 1.- Barras: Descripción

Barras Material Perfil Peso Volumen Longitud Co.pand.xy Co.pand.xz Dist.arr.sup. Dist.arr.inf.

(kp) (m³) (m) (m) (m)

67/68 Acero (S275) HE 260 A (HEA) 545.10 0.069 8.00 0.70 1.33 8.00 8.00

68/69 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

69/70 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

70/71 Acero (S275) IPE 450 (IPE) 389.72 0.050 5.02 0.05 0.73 1.00 5.02

71/72 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

72/74 Acero (S275) IPE 450 (IPE) 292.29 0.037 3.77 0.05 0.73 1.00 3.77

73/74 Acero (S275) HE 300 A (HEA) 883.12 0.112 10.00 0.70 1.22 10.00 10.00

2.- Cargas (Barras)

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

67/106

Barras Hipót. Tipo Cargas Dirección

P1 P2 L1 (m) L2 (m) X Y Z

67/68 1 (PP 1) Uniforme 0.068 t/m - - - 0.000 0.000 -1.000

67/68 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

67/68 3 (V 1) Uniforme 0.294 t/m - - - 0.000 1.000 0.000

67/68 4 (V 2) Uniforme 0.294 t/m - - - 0.000 1.000 0.000

67/68 5 (V 3) Uniforme 0.207 t/m - - - 0.000 -1.000 0.000

67/68 6 (V 4) Uniforme 0.133 t/m - - - 0.000 -1.000 0.000

67/68 7 (V 5) Uniforme 0.133 t/m - - - 0.000 -1.000 0.000

67/68 8 (V 6) Uniforme 0.149 t/m - - - 0.000 -1.000 0.000

67/68 8 (V 6) Uniforme 0.232 t/m - - - 0.000 -1.000 0.000

68/69 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

68/69 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

68/69 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

68/69 3 (V 1) Trapez. 0.583 t/m 0.583 t/m 0.000 2.010 0.000 -0.100 0.995

68/69 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 2.010 3.769 0.000 -0.100 0.995

68/69 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 2.010 0.000 0.100 -0.995

68/69 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 2.010 3.769 0.000 0.100 -0.995

68/69 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

68/69 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

68/69 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

68/69 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

68/69 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

68/69 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

68/69 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

69/70 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

69/70 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

69/70 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

69/70 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995

69/70 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995

69/70 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

69/70 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

69/70 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

69/70 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

69/70 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

69/70 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

69/70 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

70/71 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

70/71 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

70/71 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

70/71 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 5.025 0.000 -0.100 0.995

70/71 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 5.025 0.000 0.100 -0.995

70/71 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

70/71 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 5.025 0.000 -0.100 0.995

70/71 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 5.025 0.000 -0.100 0.995

70/71 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

70/71 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

68/106

70/71 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

70/71 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

71/72 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

71/72 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

71/72 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

71/72 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995

71/72 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995

71/72 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

71/72 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

71/72 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 3.769 0.000 -0.100 0.995

71/72 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

71/72 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

71/72 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

71/72 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

72/74 1 (PP 1) Uniforme 0.078 t/m - - - 0.000 0.000 -1.000

72/74 1 (PP 1) Uniforme 0.139 t/m - - - 0.000 0.000 -1.000

72/74 2 (SC 1) Uniforme 0.125 t/m - - - 0.000 0.000 -1.000

72/74 3 (V 1) Trapez. 0.240 t/m 0.240 t/m 0.000 3.769 0.000 -0.100 0.995

72/74 4 (V 2) Trapez. 0.006 t/m 0.006 t/m 0.000 3.769 0.000 0.100 -0.995

72/74 5 (V 3) Uniforme 0.213 t/m - - - 0.000 -0.100 0.995

72/74 6 (V 4) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995

72/74 6 (V 4) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995

72/74 7 (V 5) Trapez. 0.334 t/m 0.334 t/m 0.000 1.759 0.000 -0.100 0.995

72/74 7 (V 5) Trapez. 0.748 t/m 0.748 t/m 1.759 3.769 0.000 -0.100 0.995

72/74 8 (V 6) Uniforme 0.254 t/m - - - 0.000 -0.100 0.995

72/74 9 (N 1) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

72/74 10 (N 2) Uniforme 0.051 t/m - - - 0.000 0.000 -1.000

72/74 11 (N 3) Uniforme 0.101 t/m - - - 0.000 0.000 -1.000

73/74 1 (PP 1) Uniforme 0.088 t/m - - - 0.000 0.000 -1.000

73/74 1 (PP 1) Uniforme 0.050 t/m - - - 0.000 0.000 -1.000

73/74 3 (V 1) Faja 0.133 t/m - 0.000 10.000 0.000 1.000 0.000

73/74 4 (V 2) Faja 0.133 t/m - 0.000 10.000 0.000 1.000 0.000

73/74 5 (V 3) Faja 0.207 t/m - 0.000 10.000 0.000 1.000 0.000

73/74 6 (V 4) Faja 0.294 t/m - 0.000 10.000 0.000 -1.000 0.000

73/74 7 (V 5) Faja 0.294 t/m - 0.000 10.000 0.000 -1.000 0.000

73/74 8 (V 6) Faja 0.381 t/m - 0.000 10.000 0.000 1.000 0.000 3.- Desplazamientos

Nudos Descripción DESPLAZAMIENTOS (EJES GENERALES)

DX (m) DY (m) DZ (m) GX (rad) GY (rad) GZ (rad)

67 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

68 Envolvente (Desplazam.) -0.0167 -0.0350 -0.0002 -0.0068 -0.0007 -0.0026

0.0164 0.0233 0.0000 0.0026 0.0006 0.0025

69 Envolvente (Desplazam.) -0.0291 -0.0357 -0.0266 -0.0064 -0.0048 -0.0032

0.0289 0.0259 0.0066 0.0010 0.0016 0.0028

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

69/106

70 Envolvente (Desplazam.) -0.0393 -0.0358 -0.0443 -0.0028 -0.0081 -0.0023

0.0391 0.0277 0.0079 -0.0001 0.0022 0.0017

71 Envolvente (Desplazam.) -0.0440 -0.0355 -0.0416 -0.0010 -0.0079 -0.0009

0.0437 0.0274 0.0045 0.0036 0.0017 0.0002

72 Envolvente (Desplazam.) -0.0384 -0.0351 -0.0222 -0.0007 -0.0044 -0.0025

0.0382 0.0254 0.0009 0.0062 0.0008 0.0020

73 Envolvente (Desplazam.) 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

74 Envolvente (Desplazam.) -0.0278 -0.0351 -0.0002 -0.0002 -0.0011 -0.0025

0.0279 0.0232 0.0000 0.0049 0.0011 0.0024 4.- Reacciones

Nudos Descripción REACCIONES (EJES GENERALES)

RX (t) RY (t) RZ (t) MX (t�m) MY (t�m) MZ (t�m)

67 Envolvente (Cim.equil.) -0.4008 -3.2129 -0.4119 -11.2431 -1.7001 -0.0021

0.4009 3.5685 6.6018 7.6488 1.7083 0.0022

67 Envolvente (Cim.tens.terr.) -0.2505 -1.7928 0.8153 -7.6441 -1.0623 -0.0013

0.2506 2.4661 4.6398 4.2171 1.0679 0.0014

73 Envolvente (Cim.equil.) -0.5729 -3.9016 -1.6049 -16.8960 -3.0898 -0.0026

0.5617 4.9935 7.7533 13.7137 3.0471 0.0028

73 Envolvente (Cim.tens.terr.) -0.3579 -2.6737 0.2263 -9.8550 -1.9299 -0.0016

0.3511 2.9062 5.6115 9.3435 1.9048 0.0017 5.- Esfuerzos

Barras Esf. ESFUERZOS (EJES LOCALES) (t)(t�m)

0 L 1/8 L 1/4 L 3/8 L 1/2 L 5/8 L 3/4 L 7/8 L 1 L

67/68 0.000 m 1.000 m 2.000 m 3.000 m 4.000 m 5.000 m 6.000 m 7.000 m 8.000 m

Envolvente (Acero laminado)

N- -6.0283 -5.8688 -5.7093 -5.5498 -5.3903 -5.2308 -5.0713 -4.9119 -4.7524

N+ 0.7795 0.8740 0.9685 1.0631 1.1576 1.2521 1.3466 1.4411 1.5356

Ty- -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758 -0.3758

Ty+ 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758 0.3758

Tz- -3.3132 -2.8120 -2.6078 -2.4077 -2.2075 -2.0074 -1.8072 -1.6345 -1.6669

Tz+ 3.0910 2.6493 2.2076 1.7659 1.3242 0.8825 0.9010 1.4724 2.0439

Mt- -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021 -0.0021

Mt+ 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020

My- -10.4559 -7.5519 -4.8400 -2.6368 -1.4532 -2.5478 -3.2183 -3.4295 -3.2166

My+ 7.3773 4.6563 2.6521 1.5502 2.5879 3.5878 4.7933 6.3579 7.9348

Mz- -1.6014 -1.2256 -0.8500 -0.4745 -0.0993 -0.2848 -0.6606 -1.0364 -1.4122

Mz+ 1.5941 1.2183 0.8426 0.4672 0.0921 0.2776 0.6534 1.0291 1.4049

68/69 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -2.0834 -2.0564 -2.0294 -2.0024 -1.9754 -1.9484 -1.9214 -1.8944 -1.8674

N+ 2.1102 2.1184 2.1265 2.1346 2.1428 2.1509 2.1590 2.1672 2.1753

Ty- -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343 -0.2343

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

70/106

Ty+ 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587 0.2587

Tz- -4.2105 -3.9404 -3.6703 -3.4002 -3.1300 -2.8599 -2.5898 -2.3197 -2.0496

Tz+ 2.0270 1.6966 1.3661 1.1328 1.0637 0.9946 0.9255 0.8564 0.7872

Mt- -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092 -0.0092

Mt+ 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056 0.0056

My- -7.9354 -6.7330 -6.0819 -5.5154 -4.9481 -4.7714 -4.9132 -4.9793 -4.9753

My+ 3.2165 2.3426 1.6181 1.6161 2.0606 2.8529 3.9257 4.8816 5.7296

Mz- -0.4727 -0.3623 -0.2520 -0.1416 -0.0312 -0.0813 -0.2030 -0.3249 -0.4468

Mz+ 0.5283 0.4064 0.2845 0.1626 0.0408 0.0793 0.1895 0.2998 0.4102

69/70 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.9026 -1.8756 -1.8486 -1.8216 -1.7946 -1.7675 -1.7405 -1.7135 -1.6865

N+ 2.2018 2.2099 2.2181 2.2262 2.2343 2.2425 2.2506 2.2588 2.2669

Ty- -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574 -0.1574

Ty+ 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759 0.1759

Tz- -2.5468 -2.2766 -2.0065 -1.7364 -1.4663 -1.1962 -0.9261 -0.7757 -0.7642

Tz+ 0.7386 0.6694 0.6003 0.5312 0.4621 0.3930 0.3239 0.2548 0.1856

Mt- -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065 -0.0065

Mt+ 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032 0.0032

My- -4.9755 -5.2581 -5.4707 -5.6073 -5.6740 -5.6648 -5.5857 -5.4306 -5.2056

My+ 5.7292 6.6507 7.4643 8.2978 9.0097 9.5879 10.0429 10.3643 10.5625

Mz- -0.1448 -0.0706 -0.0288 -0.0690 -0.1517 -0.2344 -0.3171 -0.3998 -0.4826

Mz+ 0.1804 0.0975 0.0146 0.0784 0.1524 0.2264 0.3004 0.3744 0.4485

70/71 0.000 m 0.628 m 1.256 m 1.884 m 2.512 m 3.141 m 3.769 m 4.397 m 5.025 m

Envolvente (Acero laminado)

N- -1.7675 -1.7314 -1.6954 -1.6594 -1.6234 -1.5874 -1.5514 -1.5154 -1.4793

N+ 2.3129 2.3238 2.3346 2.3455 2.3563 2.3672 2.3780 2.3889 2.3997

Ty- -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497 -0.0497

Ty+ 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639 0.0639

Tz- -1.3726 -1.0125 -0.6523 -0.4190 -0.4543 -0.6607 -0.8671 -1.0735 -1.2800

Tz+ 0.5346 0.4173 0.3000 0.1868 0.2964 0.6146 0.9370 1.3005 1.6640

Mt- -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009 -0.0009

Mt+ 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009

My- -5.2062 -5.3758 -5.4209 -5.3311 -5.1169 -4.7678 -4.2943 -3.6859 -2.9530

My+ 10.5624 11.2250 11.6685 11.8745 11.8613 11.6107 11.1409 10.4336 9.5072

Mz- -0.0749 -0.1117 -0.1514 -0.1912 -0.2311 -0.2709 -0.3108 -0.3507 -0.3907

Mz+ 0.1070 0.1378 0.1687 0.1995 0.2304 0.2613 0.2921 0.3231 0.3543

71/72 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.5475 -1.5205 -1.4935 -1.4665 -1.4395 -1.4125 -1.3855 -1.3584 -1.3314

N+ 2.4763 2.4844 2.4926 2.5007 2.5088 2.5170 2.5251 2.5332 2.5414

Ty- -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761 -0.0761

Ty+ 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932 0.0932

Tz- -0.4873 -0.6421 -0.7969 -0.9517 -1.1066 -1.2614 -1.4162 -1.5710 -1.7258

Tz+ 0.9499 1.1885 1.4271 1.6658 1.9182 2.1908 2.4634 2.7360 3.0086

Mt- -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039 -0.0039

Mt+ 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069 0.0069

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

71/106

My- -2.9536 -2.6861 -2.3486 -1.9988 -1.9316 -1.8423 -1.7131 -1.5409 -1.3289

My+ 9.5077 9.0510 8.5714 7.9876 7.2816 6.4433 5.4829 4.3901 3.3146

Mz- -0.3917 -0.3558 -0.3199 -0.2841 -0.2482 -0.2124 -0.1768 -0.1417 -0.1066

Mz+ 0.4211 0.3772 0.3333 0.2894 0.2455 0.2016 0.1581 0.1149 0.0718

72/74 0.000 m 0.471 m 0.942 m 1.413 m 1.884 m 2.355 m 2.827 m 3.298 m 3.769 m

Envolvente (Acero laminado)

N- -1.3430 -1.3160 -1.2890 -1.2620 -1.2350 -1.2080 -1.1810 -1.1540 -1.1269

N+ 2.6343 2.6425 2.6506 2.6587 2.6669 2.6750 2.6831 2.6913 2.6994

Ty- -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179 -0.2179

Ty+ 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376 0.2376

Tz- -1.2242 -1.3790 -1.5338 -1.6886 -1.9213 -2.3688 -2.8162 -3.2636 -3.7111

Tz+ 2.8045 3.0431 3.2987 3.5713 3.8439 4.1165 4.3891 4.6617 4.9343

Mt- -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042 -0.0042

Mt+ 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082

My- -1.3287 -1.3446 -1.9867 -3.1643 -4.8767 -6.7059 -8.6431 -10.6971 -12.8591

My+ 3.3152 2.9833 2.9588 3.2784 4.1112 5.1260 6.3430 7.7793 9.4179

Mz- -0.4402 -0.3376 -0.2350 -0.1323 -0.0297 -0.0912 -0.2031 -0.3151 -0.4270

Mz+ 0.4683 0.3564 0.2445 0.1326 0.0207 0.0730 0.1756 0.2782 0.3809

73/74 0.000 m 1.250 m 2.500 m 3.750 m 5.000 m 6.250 m 7.500 m 8.750 m 10.000 m

Envolvente (Acero laminado)

N- -7.0843 -6.8509 -6.6175 -6.3841 -6.1507 -5.9173 -5.6839 -5.4505 -5.2171

N+ 1.9553 2.0937 2.2320 2.3703 2.5086 2.6469 2.7852 2.9235 3.0618

Ty- -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265 -0.5265

Ty+ 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372 0.5372

Tz- -4.7601 -4.2080 -3.6559 -3.1038 -2.5516 -1.9995 -1.4474 -2.1583 -2.8726

Tz+ 3.6255 3.3115 3.0613 2.8111 2.5609 2.3107 2.0606 1.8104 1.6048

Mt- -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026 -0.0026

Mt+ 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025

My- -16.0985 -10.5072 -5.5785 -2.6692 -4.0793 -5.5941 -8.3324 -10.7455 -12.8584

My+ 12.7509 8.4614 4.4722 1.1738 2.1809 5.0115 7.1796 8.6300 9.4178

Mz- -2.8564 -2.1985 -1.5405 -0.8826 -0.2249 -0.4606 -1.1321 -1.8037 -2.4752

Mz+ 2.8971 2.2258 1.5545 0.8833 0.2122 0.4346 1.0927 1.7508 2.4089 6.- Tensiones

Barras TENSIÓN MÁXIMA

TENS. () APROV. (%) Pos. (m) N (t) Ty (t) Tz (t) Mt (t�m) My (t�m) Mz (t�m)

67/68 0.6965 69.65 0.000 -3.0590 0.0008 -3.0080 0.0001 -10.4558 0.0317

68/69 0.2654 26.54 0.000 -1.8084 -0.0361 -2.7131 -0.0037 -7.9309 -0.0766

69/70 0.2441 24.41 3.769 -1.6865 0.0163 -0.2788 -0.0063 10.5625 -0.0389

70/71 0.2683 26.83 2.010 -1.6522 0.0089 -0.0808 0.0007 11.8937 0.0019

71/72 0.2191 21.91 0.000 -1.5474 0.0137 0.8276 0.0069 9.5068 0.0300

72/74 0.4209 42.09 3.769 -1.1101 0.0448 4.7133 0.0064 -12.8588 -0.0945

73/74 0.7485 74.85 0.000 1.9553 0.0712 -4.7601 -0.0002 -16.0985 0.4599

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

72/106

2.2.2 Cimentación

La cimentación se realizará mediante zapatas centradas para todos los

pilares, arriostradas mediante vigas de atado de hormigón armado.

Tanto las zapatas como las vigas de atado se realizarán con hormigón

armado HA-35/B/20/IV-Qc sobre cama de hormigón de limpieza HM-10 de 10

cm de espesor, y armadura de redondos de acero B-400-S.

• Acciones adoptadas en el cálculo

Para los elementos de cimentación de hormigón armado, se han

considerado las siguientes acciones:

Densidad del hormigón armado 2.50 tn/m² (2.30 t/m3 para hormigones en masa y poco armados)

Cargas y sobrecargas: Las consideradas en el CTE DB SE-A

Acciones de la estructura sobre la cimentación.

• Métodos de cálculo e hipótesis de carga

Para el cálculo de los elementos de hormigón se han considerado los

siguientes coeficientes de seguridad, correspondientes a la EHE.

COEFICIENTE DE PONDERACIÓN Y SEGURIDAD

Coeficiente de minoración de resistencia del hormigón γc = 1,50

Coeficiente de minoración de resistencia del acero γs = 1,15

Coeficiente de mayoración de las acciones γf = 1,60

• Resultados obtenidos en el cálculo de la cimentación

Descripción

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

73/106

Referencias Materiales Geometría Armado

Nudo 1 Nudo 75

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata cuadrada Ancho: 215.0 cm Canto: 50.0 cm

Sup X: 10Ø12c/22 Sup Y: 10Ø12c/22 Inf X: 10Ø12c/22 Inf Y: 10Ø12c/22

Nudo 36

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata cuadrada Ancho: 280.0 cm Canto: 65.0 cm

Sup X: 16Ø12c/17 Sup Y: 16Ø12c/17 Inf X: 16Ø12c/17 Inf Y: 16Ø12c/17

Nudo 11 Nudo 16 Nudo 41 Nudo 85

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata cuadrada Ancho: 235.0 cm Canto: 55.0 cm

Sup X: 12Ø12c/20 Sup Y: 12Ø12c/20 Inf X: 12Ø12c/20 Inf Y: 12Ø12c/20

Nudo 18 Nudo 30 Nudo 43 Nudo 51 Nudo 59 Nudo 67

Hormigón: HA-35, Yc=1.5 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 295.0 cm Ancho zapata Y: 200.0 cm Canto: 70.0 cm

Sup X: 18Ø12c/16 Sup Y: 12Ø12c/16 Inf X: 18Ø12c/16 Inf Y: 12Ø12c/16

Nudo 49 Nudo 57 Nudo 65 Nudo 73

Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 360.0 cm Ancho zapata Y: 240.0 cm Canto: 85.0 cm

Sup X: 27Ø12c/13 Sup Y: 18Ø12c/13 Inf X: 27Ø12c/13 Inf Y: 18Ø12c/13

Nudo 3 Nudo 5 Nudo 7 Nudo 9 Nudo 77 Nudo 79 Nudo 81 Nudo 83

Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 295.0 cm Ancho zapata Y: 195.0 cm Canto: 70.0 cm

Sup X: 18Ø12c/16 Sup Y: 12Ø12c/16 Inf X: 18Ø12c/16 Inf Y: 12Ø12c/16

Nudo 14 Nudo 24 Nudo 28 Nudo 39

Hormigón: HA-35, Yc=1.5 Acero: B 500 S, Ys=1.15 Tensión admisible en situaciones persistentes: 0.200 MPa Tensión admisible en situaciones accidentales: 0.300 MPa

Zapata rectangular centrada Ancho zapata X: 275.0 cm Ancho zapata Y: 195.0 cm Canto: 65.0 cm

Sup X: 16Ø12c/17 Sup Y: 11Ø12c/17 Inf X: 16Ø12c/17 Inf Y: 11Ø12c/17

Comprobación

A continuación mostramos las comprobaciones para una zapata de cada

tipo:

• Zapata NUDO 1:

Referencia: 1

Dimensiones: 215 x 215 x 50

Armados: Xi:Ø12c/22 Yi:Ø12c/22 Xs:Ø12c/22 Ys:Ø12c/22

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.175 kp/cm²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

74/106

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.158 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.435 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 153.1 %

Cumple

-En dirección Y:

Reserva seguridad: 69.8 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 1.58 t�m

Cumple

-En dirección Y:

Momento: 2.59 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 1.80 t

Cumple

-En dirección Y:

Cortante: 3.08 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 5.72 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 50 cm

Cumple

Espacio para anclar arranques en cimentación:

-1:

Mínimo: 0 cm Calculado: 43 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0002

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0003

Cumple

-Armado superior dirección X:

Mínimo: 0.0002

Cumple

-Armado superior dirección Y:

Mínimo: 0.0002

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 22 cm

Cumple

-Armado inferior dirección Y:

Calculado: 22 cm

Cumple

-Armado superior dirección X:

Calculado: 22 cm

Cumple

-Armado superior dirección Y:

Calculado: 22 cm

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

75/106

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 22 cm

Cumple

-Armado inferior dirección Y:

Calculado: 22 cm

Cumple

-Armado superior dirección X:

Calculado: 22 cm

Cumple

-Armado superior dirección Y:

Calculado: 22 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 54 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 54 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 54 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 54 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 54 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 54 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 54 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 54 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.11

- Relación rotura pésima (En dirección Y): 0.18

- Cortante de agotamiento (En dirección X): 27.21 t

- Cortante de agotamiento (En dirección Y): 27.21 t

• Zapata NUDO 41:

Referencia: 41

Dimensiones: 235 x 235 x 55

Armados: Xi:Ø12c/20 Yi:Ø12c/20 Xs:Ø12c/20 Ys:Ø12c/20

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.171 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.248 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.376 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 175.9 %

Cumple

-En dirección Y:

Reserva seguridad: 34.7 %

Cumple

Flexión en la zapata:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

76/106

-En dirección X:

Momento: 1.52 t�m

Cumple

-En dirección Y:

Momento: 3.47 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 1.59 t

Cumple

-En dirección Y:

Cortante: 4.01 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 6.46 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 55 cm

Cumple

Espacio para anclar arranques en cimentación:

-41:

Mínimo: 0 cm Calculado: 48 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0002

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0003

Cumple

-Armado superior dirección X:

Mínimo: 0.0002

Cumple

-Armado superior dirección Y:

Mínimo: 0.0002

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 20 cm

Cumple

-Armado inferior dirección Y:

Calculado: 20 cm

Cumple

-Armado superior dirección X:

Calculado: 20 cm

Cumple

-Armado superior dirección Y:

Calculado: 20 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 20 cm

Cumple

-Armado inferior dirección Y:

Calculado: 20 cm

Cumple

-Armado superior dirección X:

Calculado: 20 cm

Cumple

-Armado superior dirección Y:

Calculado: 20 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 60 cm

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

77/106

-Armado inf. dirección X hacia izq:

Calculado: 60 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 60 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 60 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 60 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 60 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 60 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 60 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.08

- Relación rotura pésima (En dirección Y): 0.18

- Cortante de agotamiento (En dirección X): 32.33 t

- Cortante de agotamiento (En dirección Y): 32.33 t

• Zapata NUDO 36:

Referencia: 36

Dimensiones: 280 x 280 x 65

Armados: Xi:Ø12c/17 Yi:Ø12c/17 Xs:Ø12c/17 Ys:Ø12c/17

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.286 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.462 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.605 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 165.1 %

Cumple

-En dirección Y:

Reserva seguridad: 20.1 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 4.60 t�m

Cumple

-En dirección Y:

Momento: 10.14 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 3.86 t

Cumple

-En dirección Y:

Cortante: 8.56 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 20.09 t/m²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

78/106

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 65 cm

Cumple

Espacio para anclar arranques en cimentación:

-36:

Mínimo: 0 cm Calculado: 58 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0003

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0005

Cumple

-Armado superior dirección X:

Mínimo: 0.0002

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 17 cm

Cumple

-Armado inferior dirección Y:

Calculado: 17 cm

Cumple

-Armado superior dirección X:

Calculado: 17 cm

Cumple

-Armado superior dirección Y:

Calculado: 17 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 17 cm

Cumple

-Armado inferior dirección Y:

Calculado: 17 cm

Cumple

-Armado superior dirección X:

Calculado: 17 cm

Cumple

-Armado superior dirección Y:

Calculado: 17 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 71 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 71 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 72 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 72 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 71 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 71 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 72 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 72 cm

Cumple

Se cumplen todas las comprobaciones

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

79/106

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.14

- Relación rotura pésima (En dirección Y): 0.31

- Cortante de agotamiento (En dirección X): 44.55 t

- Cortante de agotamiento (En dirección Y): 44.55 t

• Zapata NUDO 18:

Referencia: 18

Dimensiones: 200 x 295 x 70

Armados: Xi:Ø12c/16 Yi:Ø12c/16 Xs:Ø12c/16 Ys:Ø12c/16

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.273 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.434 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.559 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 409.0 %

Cumple

-En dirección Y:

Reserva seguridad: 68.6 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 1.89 t�m

Cumple

-En dirección Y:

Momento: 6.93 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 1.15 t

Cumple

-En dirección Y:

Cortante: 5.50 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 15.4 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 70 cm

Cumple

Espacio para anclar arranques en cimentación:

-18:

Mínimo: 0 cm Calculado: 63 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

80/106

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0004

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0002

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 16 cm

Cumple

-Armado inferior dirección Y:

Calculado: 16 cm

Cumple

-Armado superior dirección X:

Calculado: 16 cm

Cumple

-Armado superior dirección Y:

Calculado: 16 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 16 cm

Cumple

-Armado inferior dirección Y:

Calculado: 16 cm

Cumple

-Armado superior dirección X:

Calculado: 16 cm

Cumple

-Armado superior dirección Y:

Calculado: 16 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 29 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 29 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 77 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 77 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 29 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 29 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 77 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 77 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.05

- Relación rotura pésima (En dirección Y): 0.26

- Cortante de agotamiento (En dirección X): 49.86 t

- Cortante de agotamiento (En dirección Y): 33.62 t

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

81/106

• Zapata NUDO 49:

Referencia: 49

Dimensiones: 240 x 360 x 85

Armados: Xi:Ø12c/13 Yi:Ø12c/13 Xs:Ø12c/13 Ys:Ø12c/13

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.31 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.49 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.621 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 522.9 %

Cumple

-En dirección Y:

Reserva seguridad: 23.6 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 3.49 t�m

Cumple

-En dirección Y:

Momento: 14.50 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 1.65 t

Cumple

-En dirección Y:

Cortante: 10.78 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 15.26 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 85 cm

Cumple

Espacio para anclar arranques en cimentación:

-49:

Mínimo: 0 cm Calculado: 78 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0005

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

82/106

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 13 cm

Cumple

-Armado inferior dirección Y:

Calculado: 13 cm

Cumple

-Armado superior dirección X:

Calculado: 13 cm

Cumple

-Armado superior dirección Y:

Calculado: 13 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 13 cm

Cumple

-Armado inferior dirección Y:

Calculado: 13 cm

Cumple

-Armado superior dirección X:

Calculado: 13 cm

Cumple

-Armado superior dirección Y:

Calculado: 13 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 35 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 35 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 96 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 96 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 35 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 35 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 96 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 96 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.05

- Relación rotura pésima (En dirección Y): 0.30

- Cortante de agotamiento (En dirección X): 72.52 t

- Cortante de agotamiento (En dirección Y): 48.12 t

• Zapata NUDO 7:

Referencia: 7

Dimensiones: 195 x 295 x 70

Armados: Xi:Ø12c/16 Yi:Ø12c/16 Xs:Ø12c/16 Ys:Ø12c/16

Comprobación Valores Estado

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

83/106

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.24 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.303 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.481 kp/cm²

Cumple

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 705.2 %

Cumple

-En dirección Y:

Reserva seguridad: 3.3 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 1.11 t�m

Cumple

-En dirección Y:

Momento: 7.88 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 0.65 t

Cumple

-En dirección Y:

Cortante: 6.65 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 8.33 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 70 cm

Cumple

Espacio para anclar arranques en cimentación:

-7:

Mínimo: 0 cm Calculado: 63 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0005

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-98)

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 16 cm

Cumple

-Armado inferior dirección Y:

Calculado: 16 cm

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

84/106

-Armado superior dirección X:

Calculado: 16 cm

Cumple

-Armado superior dirección Y:

Calculado: 16 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 16 cm

Cumple

-Armado inferior dirección Y:

Calculado: 16 cm

Cumple

-Armado superior dirección X:

Calculado: 16 cm

Cumple

-Armado superior dirección Y:

Calculado: 16 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 27 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 27 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 77 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 77 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 27 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 27 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 77 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 77 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.03

- Relación rotura pésima (En dirección Y): 0.31

- Cortante de agotamiento (En dirección X): 49.86 t

- Cortante de agotamiento (En dirección Y): 32.76 t

• Zapata NUDO 14:

Referencia: 14

Dimensiones: 195 x 275 x 65

Armados: Xi:Ø12c/17 Yi:Ø12c/17 Xs:Ø12c/17 Ys:Ø12c/17

Comprobación Valores Estado

Tensiones sobre el terreno:

Criterio de CYPE Ingenieros

-Tensión media en situaciones persistentes:

Máximo: 2 kp/cm² Calculado: 0.208 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes sin viento:

Máximo: 2.5 kp/cm² Calculado: 0.21 kp/cm²

Cumple

-Tensión máxima en situaciones persistentes con viento:

Máximo: 2.5 kp/cm² Calculado: 0.427 kp/cm²

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

85/106

Vuelco de la zapata:

Si el % de reserva de seguridad es mayor que cero, quiere decir que los coeficientes de seguridad al vuelco son mayores que los valores estrictos exigidos para todas las combinaciones de equilibrio.

-En dirección X:

Reserva seguridad: 623.1 %

Cumple

-En dirección Y:

Reserva seguridad: 1.9 %

Cumple

Flexión en la zapata:

-En dirección X:

Momento: 1.05 t�m

Cumple

-En dirección Y:

Momento: 6.04 t�m

Cumple

Cortante en la zapata:

-En dirección X:

Cortante: 0.82 t

Cumple

-En dirección Y:

Cortante: 5.69 t

Cumple

Compresión oblicua en la zapata:

-Situaciones persistentes:

Criterio de CYPE Ingenieros

Máximo: 509.68 t/m² Calculado: 6.86 t/m²

Cumple

Canto mínimo:

Artículo 59.8.1 (norma EHE-98)

Mínimo: 25 cm Calculado: 65 cm

Cumple

Espacio para anclar arranques en cimentación:

-14:

Mínimo: 0 cm Calculado: 58 cm

Cumple

Cuantía geométrica mínima:

Criterio de CYPE Ingenieros

Mínimo: 0.002

-En dirección X:

Calculado: 0.0021

Cumple

-En dirección Y:

Calculado: 0.0021

Cumple

Cuantía mínima necesaria por flexión:

Artículo 42.3.2 (norma EHE-98)

Calculado: 0.0011

-Armado inferior dirección X:

Mínimo: 0.0001

Cumple

-Armado inferior dirección Y:

Mínimo: 0.0004

Cumple

-Armado superior dirección X:

Mínimo: 0.0001

Cumple

-Armado superior dirección Y:

Mínimo: 0.0003

Cumple

Diámetro mínimo de las barras:

Recomendación del Artículo 59.8.2 (norma EHE-

Mínimo: 12 mm

-Parrilla inferior:

Calculado: 12 mm

Cumple

-Parrilla superior:

Calculado: 12 mm

Cumple

Separación máxima entre barras:

Artículo 59.8.2 (norma EHE-98)

Máximo: 30 cm

-Armado inferior dirección X:

Calculado: 17 cm

Cumple

-Armado inferior dirección Y:

Calculado: 17 cm

Cumple

-Armado superior dirección X:

Calculado: 17 cm

Cumple

-Armado superior dirección Y:

Calculado: 17 cm

Cumple

Separación mínima entre barras:

Recomendación del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 10 cm

-Armado inferior dirección X:

Calculado: 17 cm

Cumple

-Armado inferior dirección Y:

Calculado: 17 cm

Cumple

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

86/106

-Armado superior dirección X:

Calculado: 17 cm

Cumple

-Armado superior dirección Y:

Calculado: 17 cm

Cumple

Longitud de anclaje:

Criterio del libro "Cálculo de estructuras de cimentación", J. Calavera. ed. INTEMAC, 1991

Mínimo: 15 cm

-Armado inf. dirección X hacia der:

Calculado: 32 cm

Cumple

-Armado inf. dirección X hacia izq:

Calculado: 32 cm

Cumple

-Armado inf. dirección Y hacia arriba:

Calculado: 72 cm

Cumple

-Armado inf. dirección Y hacia abajo:

Calculado: 72 cm

Cumple

-Armado sup. dirección X hacia der:

Calculado: 32 cm

Cumple

-Armado sup. dirección X hacia izq:

Calculado: 32 cm

Cumple

-Armado sup. dirección Y hacia arriba:

Calculado: 72 cm

Cumple

-Armado sup. dirección Y hacia abajo:

Calculado: 72 cm

Cumple

Se cumplen todas las comprobaciones

Información adicional:

- Zapata de tipo rígido (Artículo 59.2 (norma EHE-98))

- Relación rotura pésima (En dirección X): 0.04

- Relación rotura pésima (En dirección Y): 0.27

- Cortante de agotamiento (En dirección X): 43.75 t

- Cortante de agotamiento (En dirección Y): 30.86 t

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

87/106

( )

=

∑=

221

mMj

om

McalA

RCqG

Qs

n

i

aiii

3.1 Caracterización

3.1.1 Configuración

De acuerdo con el Real Decreto 2267/2004, de 3 de Diciembre, que

aprueba el Reglamento de Seguridad contra incendios en establecimientos

industriales, el establecimiento es del tipo E.

3.1.2 Carga de fuego de las áreas de incendio

Para el cálculo del nivel de riesgo intrínseco del establecimiento

procederemos al cálculo de la densidad de carga al fuego del establecimiento

mediante la metodología dada por el anteriormente citado R.D. 2267/2004:

Calculamos en primer lugar la densidad de carga de fuego de cada uno de

los sectores de incendio en los que está dividida la instalación, y que en este

caso coincidirán con cada una de los distintos edificios de los que está

compuesta:

donde:

QS = densidad de carga de fuego, ponderada y corregida, del sector o área de

incendio, en MJ/m2 o Mcal/m2.

3

3 Cálculo del sistema contra incendios

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

88/106

( )

=

∑=

221

mMj

om

McalA

RCSq

Qs

n

i

aiisi

Gi = masa, en kg, de cada uno de los combustibles (i) que existen en el sector

o área de incendio (incluidos los materiales constructivos combustibles).

qi = poder calorífico, en MJ/kg o Mcal/kg, de cada uno de los combustibles (i)

que existen en el sector de incendio.

n= número de combustibles diferentes que existen en el sector de incendios.

Ci = coeficiente adimensional que pondera el grado de peligrosidad (por la

combustibilidad) de cada uno de los combustibles (i) que existen en el sector de

incendio.

Ra = coeficiente adimensional que corrige el grado de peligrosidad (por la

activación) inherente a la actividad industrial que se desarrolla en el sector de

incendio, producción, montaje, transformación, reparación, almacenamiento,

etc.

A = superficie construida del sector de incendio o superficie ocupada del área

de incendio, en m2.

Como alternativa a la fórmula anterior se puede evaluar la densidad de

carga de fuego, ponderada y corregida, Qs, del sector de incendio aplicando las

siguientes expresiones:

a) Para actividades de producción, transformación, reparación o cualquier otra

distinta al almacenamiento:

donde:

QS, Ci , Ra y A tienen la misma significación que en el apartado anterior.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

89/106

( )

=

∑=

221

mMj

om

McalA

RhCqS

Qs

n

i

aiivii

qsi = densidad de carga de fuego de cada zona con proceso diferente según los

distintos procesos que se realizan en el sector de incendio (i), en MJ/m2 o

Mcal/m2.

Si = superficie de cada zona con proceso diferente y densidad de carga de

fuego, qsi diferente, en m2.

n= número de procesos diferentes que se llevan a cabo en el sector de

incendios.

Los valores de la densidad de carga de fuego media, qsi, pueden

obtenerse de la tabla 1.2.

b) Para actividades de almacenamiento:

donde:

QS, Ci, Ra y A tienen la misma significación que en el apartado anterior.

qvi = carga de fuego, aportada por cada m3 de cada zona con diferente tipo de

almacenamiento (i) existente en el sector de incendio, en MJ/m3 o Mcal/m3.

hi = altura del almacenamiento de cada uno de los combustibles, (i), en m.

si = superficie ocupada en planta por cada zona con diferente tipo de

almacenamiento (i) existente en el sector de incendio en m2.

n= número de combustibles diferentes almacenados en el sector de incendios.

Los valores de la carga de fuego, por metro cúbico qvi, aportada por cada

uno de los combustibles, pueden obtenerse de la tabla 1.2.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

90/106

( )

=

=

=22

1

1

mMj

om

Mcal

A

AQ

Qen

i

i

n

i

isi

( )

=

=

=22

1

1

mMj

om

Mcal

A

RAQ

Qn

i

ei

n

i

aeiei

E

El nivel de riesgo intrínseco de un edificio o un conjunto de sectores y/o

áreas de incendio de un establecimiento industrial, a los efectos de la aplicación

de este reglamento, se evaluará calculando la siguiente expresión, que

determina la densidad de carga de fuego, ponderada y corregida, Qe, de dicho

edificio industrial.

donde:

Qe = densidad de carga de fuego, ponderada y corregida, del edificio industrial,

en MJ/m2 o Mcal/m2.

Qsi = densidad de carga de fuego, ponderada y corregida, de cada uno de los

sectores o áreas de incendio, (i), que componen el edificio industrial, en MJ/m2

o Mcal/m2.

Ai = superficie construida de cada uno de los sectores o áreas de incendio, (i),

que componen el edificio industrial, en m2.

n= número de sectores o áreas de incendios del edificio.

A los efectos de este reglamento, el nivel de riesgo intrínseco de un

establecimiento industrial, cuando desarrolla su actividad en más de un edificio,

ubicados en un mismo recinto, se evaluará calculando la siguiente expresión,

que determina la carga de fuego, ponderada y corregida, QE, de dicho

establecimiento industrial:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

91/106

donde:

QE = densidad de carga de fuego, ponderada y corregida, del establecimiento

industrial, en MJ/m2 o Mcal/m2.

Qei = densidad de carga de fuego, ponderada y corregida, de cada uno de los

edificios industriales, (i), que componen el establecimiento industrial en MJ/m2

o Mcal/m2.

Aei = superficie construida de cada uno de los edificios industriales, (i), que

componen el establecimiento industrial, en m2.

n= número de edificios diferentes que componen el establecimiento industrial.

Evaluada la densidad de carga de fuego ponderada, y corregida de un

sector o área de incendio, (QS), de un edificio industrial (Qe) o de un

establecimiento industrial (QE), según cualquiera de los procedimientos

expuestos en los apartados anteriores, el nivel de riesgo intrínseco del sector o

área de incendio, del edificio industrial, o del establecimiento industrial, se

deduce de la tabla 1.3.

A continuación calculamos el nivel de riesgo intrínseco de cada área del

establecimiento:

3.1.2.1 Área de almacenamiento

Esta área se ubica en el edificio de almacenamiento de troncos. En ella se

almacenan los troncos de eucalipto que llegan a la planta. Además en esta

área se realiza el astillado de la madera y un almacenamiento primario de las

astillas. Los datos a tener en cuenta para el cálculo del nivel de riesgo

intrínseco, considerando que es tanto una actividad de almacenamiento como

una actividad de maquinaria, son:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

92/106

Almacenamiento de troncos:

• Densidad de carga al fuego media (qs) � 6300 MJ/m3

• Riesgo de activación (Ra) � 1,5

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie almacenamiento � 185 m2

• Altura de almacenamiento (h) � 3 m

• Qs � 24570 MJ/m2

Almacenamiento de astillas:

• Densidad de carga al fuego media (qs) � 2100 MJ/m3

• Riesgo de activación (Ra) � 2,0

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie almacenamiento � 25 m2

• Altura de almacenamiento (h) � 5 m

• Qs � 13650 MJ/m2

Maquinaria:

• Densidad de carga al fuego media (qs) � 200 MJ/m2

• Riesgo de activación (Ra) � 1,5

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie � 15 m2

• Qs � 260 MJ/m2

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

93/106

La superficie total del área es 600 m2 y haciendo la combinación las

actividades tenemos que la carga de fuego ponderada para esta área es de

12226 MJ/m2.

3.1.2.2 Área silo principal

Esta área junto al edificio de proceso. En ella se realiza el

almacenamiento de las astillas previo al secado de las mismas. Los datos a

tener en cuenta para el cálculo del nivel de riesgo intrínseco, considerando que

es una actividad de almacenamiento:

• Densidad de carga al fuego media (qs) � 2100 MJ/m3

• Riesgo de activación (Ra) � 2,0

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie almacenamiento � 100 m2

• Altura de almacenamiento (h) � 11 m

• Qs � 30030 MJ/m2

La superficie total del área es 100 m2 y haciendo la combinación las

actividades tenemos que la carga de fuego ponderada para esta área es de

60060 MJ/m2.

3.1.2.3 Área proceso

Esta área en el edificio de proceso. Los datos a tener en cuenta para el

cálculo del nivel de riesgo intrínseco, considerando que es tanto una actividad

de almacenamiento como de maquinaria:

Almacenamiento de astillas:

• Densidad de carga al fuego media (qs) � 2100 MJ/m3

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

94/106

• Riesgo de activación (Ra) � 2,0

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie almacenamiento � 8 m2

• Altura de almacenamiento (h) � 2 m

• Qs � 5460 MJ/m2

Maquinaria:

• Densidad de carga al fuego media (qs) � 200 MJ/m2

• Riesgo de activación (Ra) � 1,5

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie � 500 m2

• Qs � 260 MJ/m2

La superficie total del área es 700 m2 y haciendo la combinación las

actividades tenemos que la carga de fuego ponderada para esta área es de

290 MJ/m2.

3.1.2.4 Área sala de control

Esta área se encuentra en el edificio de proceso. En ella se encuentran los

equipos necesarios para el control del proceso de generación de energía. Los

datos a tener en cuenta para el cálculo del nivel de riesgo intrínseco son:

• Densidad de carga al fuego media (qs) � 600 MJ/m3

• Riesgo de activación (Ra) � 1,5

• Coef. de peligrosidad por comb. (Ci) � 1,0

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

95/106

• Superficie � 100 m2

• Qs � 30030 MJ/m2

La superficie total del área es 100 m2, por lo que la carga de fuego

ponderada para esta área es de 900 MJ/m2.

3.1.2.5 Área de transformación

Esta área se encuentra en el edificio de proceso. En ella se encuentra el

transformador elevador. Los datos a tener en cuenta para el cálculo del nivel

de riesgo intrínseco son:

• Densidad de carga al fuego media (qs) � 300 MJ/m3

• Riesgo de activación (Ra) � 1,5

• Coef. de peligrosidad por comb. (Ci) � 1,3

• Superficie � 100 m2

• Qs � 390 MJ/m2

La superficie total del área es 100 m2, por lo que la carga de fuego

ponderada para esta área es de 585 MJ/m2.

3.1.2.6 Área exterior

Esta área comprende todas las zonas al aire libre del establecimiento,

formada por los viales, zonas de aparcamiento, acerados, y la zona donde se

encuentran el depósito de agua para proceso y las torres de refrigeración. Los

datos a tener en cuenta para el cálculo del nivel de riesgo intrínseco son:

• Densidad de carga al fuego media (qs) � 200 MJ/m3

• Riesgo de activación (Ra) � 1,0

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

96/106

• Coef. de peligrosidad por comb. (Ci) � 1,0

• Superficie � 5946 m2

• Qs � 200 MJ/m2

La superficie total del área es 5946 m2, por lo que la carga de fuego

ponderada para esta área es de 200 MJ/m2.

3.1.2.7 Área caseta de control de acceso

En ella se encuentra la caseta donde se registran las entradas y salidas de

camiones, midiéndose además la humedad de los troncos de entrada y la

cantidad de los mismos. Los datos a tener en cuenta para el cálculo del nivel

de riesgo intrínseco son:

• Densidad de carga al fuego media (qs) � 400 MJ/m3

• Riesgo de activación (Ra) � 1,0

• Coef. de peligrosidad por comb. (Ci) � 1,0

• Superficie � 54 m2

• Qs � 400 MJ/m2

La superficie total del área es 54 m2, por lo que la carga de fuego

ponderada para esta área es de 400 MJ/m2.

3.1.2.8 Área edificio servicios generales

Esta área se regula según el Código Técnico de la Edificación (BOE nº 74

de 28 de marzo de 2006) y su Documento Básico, Seguridad en caso de

incendio (DB-SI), puesto que en ella se realiza una actividad no industrial y el

área construida es superior a 250 m2.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

97/106

El Documento Básico DB-SI especifica parámetros objetivos y

procedimientos cuyo cumplimiento asegura la satisfacción de las exigencias

básicas y la superación de los niveles mínimos de calidad propios del requisito

básico de seguridad en caso de incendio, excepto en el caso de los edificios,

establecimientos y zonas de uso industrial a los que les sea de aplicación el

“Reglamento de seguridad contra incendios en los establecimiento industriales”,

en los cuales las exigencias básicas se cumplen mediante dicha aplicación.

Exigencia básica SI 1: Propagación Interior: se limitará el riesgo de

propagación del incendio por el interior del edificio.

Exigencia básica SI 2: Propagación exterior: se limitará el riego de

propagación del incendio por el exterior, tanto en el edificio considerado como

otros edificios.

Exigencia básica SI 3: Evacuación de ocupantes: el edificio dispondrá de

los medios de evacuación adecuados para que los ocupantes puedan

abandonarlo o alcanzar un lugar seguro dentro del mismo en condiciones de

seguridad.

Exigencia básica SI 4: Instalaciones de protección contra incendios: el

edificio dispondrá de los equipos e instalaciones adecuados para hacer posible

la detección, el control y la extinción del incendio, así como la transmisión de la

alarma a los ocupantes.

Exigencia básica SI 5: Intervención de bomberos: se facilitará la

intervención de los equipos de rescate y de extinción de incendios.

Exigencia básica SI 6: Resistencia al fuego de la estructura: la estructura

portante mantendrá su resistencia al fuego durante el tiempo necesario para

que puedan cumplirse las anteriores exigencias básicas.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

98/106

Compartimentación en sectores de incendio

El edificio de servicios generales constituye un único sector de incendios,

ya que al ser catalogado como de pública concurrencia tiene un área construida

menor que 2500 m2, separado del resto de los edificios industriales mediante

paramentos con la resistencia al fuego requerida en el CT. El área construida

de dicho sector es:

S= 500 m2

Para el cálculo de la densidad carga de fuego emplearemos el ANEJO B.4

del Documento Básico, Seguridad en caso de incendio (DB-SI). El valor de

cálculo de la densidad de carga de fuego se determina en función del valor

característico de la carga de fuego del sector, así como de la probabilidad de

activación y de las previsibles consecuencias del incendio, como:

qf,d =q f,k * m * δq1 * δq2 * δn * δc

siendo:

qf,k valor característico de la densidad de carga de fuego, según B.5.

m coeficiente de combustión que tiene en cuenta la fracción del

combustible que arde en el incendio. En los casos en los que el material

incendiado sea de tipo celulósico (madera, papel, tejidos, etc.) puede tomarse

m= 0,8. Cuando se trate de otro tipo de material y no se conozca su coeficiente

de combustión puede tomarse m=1 del lado de la seguridad.

δq1 coeficiente que tiene en cuenta el riesgo de iniciación debido al

tamaño del sector.

δq2 coeficiente que tiene en cuenta el riesgo de iniciación debido al tipo de

uso o actividad.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

99/106

δn coeficiente que tiene en cuenta las medidas activas voluntarias

existentes, δn = δn1 δn2 δn3

δc coeficiente de corrección según las consecuencias del incendio.

Por tanto, el valor de cálculo de la densidad de carga de fuego del área

SG01-EDIFICIO SERVICIOS GENERALES es:

3.2 Sectorización

La máxima superficie construida admisible de cada sector de incendio

será la que se indica en la siguiente tabla:

Máxima superficie construida admisible de cada sector de incendio

Riesgo intrínseco del sector de incendio Configuración del establecimiento Tipo A m2

Tipo B m2

Tipo C m2

Bajo: (1) (2) (3) (2) (3) (5) (3) (4) 1 2.000 6.000 SIN LÍMITE 2 1.000 4.000 6.000

Medio:

(1) (2) (3) (2) (3) (3) (4) 3 500 3.500 5.000 4 400 3.000 4.000 5 300 2.500 3.500

Alto:

(3) (3) (4) 6

No admitido 2.000 3.000

7 1.500 2.500 8 No admitido 2.000

3.2.1 Sectores de incendio

Un sector de incendio puede estar formado por una o varias áreas de

incendio. En nuestro caso el establecimiento estará formado por cinco sectores

de incendios. A continuación se muestra una tabla donde se enumeran los

2, 6310.187.025.159.11365m

MJq df =⋅⋅⋅⋅⋅=

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

100/106

distintos sectores con las áreas de incendio que los componen, además de los

valores de las cargas de fuego y el nivel de riesgo intrínseco de cada sector.

Cabe destacar que en el sector “servicios generales” no tiene sentido hablar de

nivel de riesgo ni de configuración, ya que este sector se rige por el CTE.

SECTORES ÁREAS QUE LO

FORMAN SUPERFICIE DEL ÁREA

(m2) CARGA DE FUEGO

(MJ/m2) NIVEL DE RIESGO

CONFIGURACIÓN

EXTERIOR EXTERIOR 5946 200

CASETA DE COTROL DE ACCESO

54 400

SECTOR 6000 202 BAJO 1 E

ALMACENAMIENTO ALMACENAMIENTO 600 8151

SECTOR 600 8151 ALTO 7 C

SILO PRINCIPAL SILO PRINCIPAL 100 60060

SECTOR 100 60060 ALTO 8 C

PROCESO PROCESO 700 290

SALA DE CONTROL 50 900

SALA DE TRANSFORMACIÓN

50 585

SECTOR 800 347 BAJO 1 C

SERVICIOS GENERALES

SERVICIOS GENERALES

500 588

SECTOR 500 631 CTE -

Fig. 7: Cálculo de la carga de fuego de las áreas/sectores

3.2.2 Nivel de riesgo del establecimiento

Hasta ahora hemos calculado el nivel de riesgo intrínseco de los sectores

de incendio que componen la instalación completa, por lo que calcularemos a

continuación el nivel de riesgo intrínseco de todo el establecimiento.

( )21587m

MJQE =

El nivel de riesgo intrínseco del establecimiento es por tanto medio 4.

3.3 Instalaciones necesarias

De acuerdo con lo establecido en el Reglamento de Instalaciones de

Protección Contra Incendios en los Establecimientos Industriales 2267/2004, de

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

101/106

3 de Diciembre; en este apartado se cuestiona la necesidad de las

instalaciones y actuaciones para el cumplimiento de la citada norma.

3.3.1 Hidrantes exteriores

Debido a que los sectores de incendios que conforman el establecimiento

tienen una configuración tipo C o E, a que todos los sectores tienen una

superficie inferior a 2000 m2 (excepto el exterior), y puesto que el sector

exterior tiene riesgo intrínseco bajo, no es necesario la instalación de hidrantes

exteriores según el RD 2267/2004.

3.3.2 Red de bocas de incendio equipadas (BIEs)

Según el RD 2267/2004, será necesaria la instalación de una red de BIEs

en el sector ALMACENAMIENTO, puesto que tiene una configuración tipo C, su

nivel de riesgo intrínseco es alto y su superficie total construida es mayor de

500 m2.

Se instalarán dos BIEs de 25 mm con toma de 45 mm, puesto que son

suficientes para cubrir todo el sector.

3.3.3 Rociadores automáticos

Debido a que los sectores de incendios de riesgo intrínseco alto tienen una

superficie inferior a 1000 m2, no es necesaria la instalación de rociadores

automáticos según el RD 2267/2004.

3.3.4 Columna seca

No es necesaria la instalación de sistemas de columna seca según el RD

2267/2004 puesto que la altura de evacuación del establecimiento industrial es

inferior a 15 m.

3.3.5 Sistema de abastecimiento de agua y grupo de bombeo

Será necesaria la instalación de un sistema de abastecimiento de agua

para las BIEs del sector Almacenamiento.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

102/106

El grupo de bombeo estará formado por una bomba eléctrica y una jockey

para la presurización del sistema. Se dispondrá además de un depósito con

agua suficiente para el funcionamiento en continuo de las dos BIEs durante 60

min, que estará destinado exclusivamente a tal fin.

3.3.6 Extintores de incendio

Se instalarán extintores de incendio portátiles en todos los sectores de

incendio, menos en el área exterior ya que es de configuración tipo E y su nivel

de riesgo es bajo 1. Los extintores empleados serán de polvo polivalente ABC

de 6kg, con una eficacia mínima de 34A.

Junto a los cuadros eléctricos se instalarán además extintores de anhídrido

carbónico (CO2) para evitar los posibles conatos de incendio de origen eléctrico,

puesto que los de polvo ABC no se permiten por norma para este fin al ser

conductores de la electricidad.

3.3.7 Detectores automáticos

Según el RD 2267/2004 no es necesario la instalación de detectores

automáticos de incendio en ningún sector, puesto que en los de riesgo

intrínseco bajo no es necesario, los sectores de riesgo intrínseco alto tienen una

superficie menor de 800 m2.

3.3.8 Sistemas manuales de alarma de incendios

Se instalarán sistemas manuales de alarma de incendios (pulsadores) en

todos los sectores de nuestro establecimiento. Se colocarán siempre junto a las

salidas de los diferentes sectores.

3.3.9 Estabilidad al fuego de los elementos constru ctivos portantes

Todos los sectores de incendio cumplirán la estabilidad al fuego que fijada

por el Real Decreto 2267/2004, es decir:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

103/106

• Sectores de riesgo alto: EF-90

• Sectores de riesgo medio: EF-60

• Sectores de riesgo bajo: EF-30

Además todas las escaleras que sean recorridos de evacuación deben

cumplir con las exigencias anteriores.

Cuando una medianería o un elemento constructivo de compartimentación

en sectores de incendio acometa a la cubierta, la resistencia al fuego de esta

será, al menos, igual a la mitad de la exigida a aquel elemento constructivo, en

una franja cuya anchura sea igual a 1 m. Esta franja podrá encontrarse:

• Integrada en la propia cubierta, siempre que se justifique la permanencia

de la franja tras el colapso de las partes de la cubierta no resistente.

• Fijada en la estructura de la cubierta, cuando esta tenga al menos la

misma estabilidad al fuego que la resistencia exigida a la franja.

• Formada por una barrera de un m de ancho que justifique la resistencia

al fuego requerida y se sitúe por debajo de la cubierta fijada a la

medianería. La barrera no se instalará en ningún caso a una distancia

mayor de 40 cm de la parte inferior de la cubierta.

No obstante, si la medianería o el elemento compartimentador se prolonga

un metro por encima de la cubierta, como mínimo, no es necesario que la

cubierta cumpla la condición anterior.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

104/106

3.3.10 Evacuación

• Recorridos de evacuación:

Las distancias máximas de los recorridos de evacuación de los sectores de

incendio no superarán los valores indicados en el Real Decreto 2267/2004,

serán los siguientes:

Riesgo 1 salida recorrido único 2 salidas alternativas

Bajo 35 m (*) 50 m

Medio 25 m (**) 50 m

Alto - 25 m

(*) La distancia se podrá aumentar a 50 m si la ocupación es inferior a 25

personas.

(**) La distancia se podrá aumentar a 35 m si la ocupación es inferior a

25 personas.

• Puertas de evacuación:

Las puertas situadas en los recorridos de las vías de evacuación abrirán

siempre en el sentido de la evacuación y se deberán poder abrir en cualquier

momento desde el interior sin ayuda especial.

Las puertas de evacuación deberán ser abatibles, de eje vertical y con una

anchura de al menos 80 cm. Estas puertas no pueden estar instaladas sobre los

portones para vehículos, sean estos motorizados o no. Los portones para

vehículos no se considerarán salidas de evacuación.

El mecanismo de apertura de las puertas de de evacuación la planta serán

barras de emergencia conforme a UNE EN 1125 en los sectores de mayor

ocupación. En el resto de zonas pueden instalarse manillas o pulsadores

conforme UNE EN 179.

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

105/106

• Alumbrado de emergencia:

El alumbrado de emergencia se realizará de acuerdo a lo especificado en

el apartado “3.16. Instalación de alumbrado” de la Especificación General de

Equipos Electromecánicos, electricidad, control e instrumentación.

La instalación de alumbrado de emergencia se diseñará de acuerdo con lo

indicado en la ITC-BT-028 del REBT y el CTE.

Para otros casos, se establecerán como mínimo los requerimientos

siguientes en su diseño:

Niveles de iluminación:

Tipo de alumbrado Nivel de iluminación Alumbrado de evacuación para reconocer y utilizar las

rutas de evacuación en los ejes de los pasos principales (medido en el suelo)

1 lux

Alumbrado de evacuación para identificar los puntos de los servicios contra incendios (puestos de control locales y

BIEs) y cuadros locales de fuerza y alumbrado 5 lux

Alumbrado de ambiente para identificar y acceder a las rutas de evacuación 0,5 lux

Alumbrado de reemplazamiento en salas eléctricas. 150 lux (50 % del alumbrado de la sala)

Alumbrado de reemplazamiento en salas de control. 250 lux (50 % del alumbrado de la sala)

La instalación de los sistemas de alumbrado de emergencia será fija,

estará provista de fuente propia de energía y será capaz de mantener la

intensidad indicada en cada caso al menos durante una hora.

• Señalización:

Se señalizarán todas las salidas de uso habitual y de emergencia, así como

los medios de protección contra incendios de utilización manual, según la

norma UNE 23034 y en base a los siguientes criterios:

CÁLCULOS

PLANTA DE GENERACIÓN DE ENERGÍA ELÉCTRICA A PARTIR DE BIOMASA CON UNA POTENCIA DE 2 MW

106/106

a) Las salidas de recinto, planta o edificio de más de 50 m2 tendrán

una señal con el rótulo “SALIDA”, que serán fácilmente visibles

desde todo punto de dichos recintos.

b) La señal con el rótulo “Salida de emergencia” se utilizará en toda

salida prevista para uso exclusivo en caso de emergencia.

c) Se dispondrá de señales indicativas de dirección de los recorridos,

visibles desde todo origen de evacuación desde el que no se

perciban directamente las salidas o sus señales indicativas.

d) En los puntos de los recorridos de evacuación en los que existan

alternativas que puedan inducir a error, también se dispondrán las

señales antes citadas, de forma que quede claramente indicada la

alternativa correcta. Tal es el caso de determinados cruces o

bifurcaciones de pasillos, así como de aquellas escaleras que, en la

planta de salida del edificio, continúen su trazado hacia plantas más

bajas, etc.

e) En dichos recorridos, junto a las puertas que no sean salida y que

puedan inducir a error en la evacuación debe disponerse la señal

con el rótulo “SIN SALIDA” en lugar fácilmente visible.

f) Las señales se instalarán a una altura y en una posición apropiadas

en relación al ángulo visual, teniendo en cuenta posibles

obstáculos.

g) Bajo ningún pretexto se colocarán las señales en las hojas de las

puertas, ya que, en caso de que ésta quedase abierta no sería

visible.