Post on 04-Nov-2015
description
ANCHO SOBRECARGA
MURO 0.400 0.500 T/M2
T
DATOS (MTS)
SISMO
Bz= 1.80 mts 0.50
T = 0.40 mts DENSIDAD ALTURA
hz= 0.50 mts 1.88 Tn/m3 P2 Hp 3.10
Hp= 3.10 mts Dp 3.10 Fp ANGULO FRICCION
E = 0.25 mts 33
G = 0.00 mts
Dp= 3.10 mts P3 P5
Fp= 3.10 6
M = 0.70 mts M E G N
N = 0.45 mts Hd 1.200 P1 hz 0.50
Hd= 1.20 mts
B
BASE 1.804
Peso especifico del concreto (w)= 2.40 T/m3
Peso especifico suelo (&)= 1.88 T/m3
Angulo de Friccion ()= 32.74 Grados
Presion admisible de terreno (q)= 1.42 Kg/cm2
Coeficiente Friccion (u) 0.60 0.52
S/C 0.50 T/m2
Elemento Peso (Ton) Brazo (m) Mr = P*X h s/c 0.266 mts
1 2.16 0.90 1.95
2 2.98 1.15 3.42 Ka 0.298
3 0.93 0.87 0.81
4 0.00 1.35 0.00 Pa 2.016
5 2.64 1.58 4.17
S/C 0.23 1.58 0.36 Ps/c 0.149
Total 8.94 10.71
Ea 3.63 1.20 4.35 u 0.600
S/C 0.54 1.80 0.97
Total 4.16 5.32
** Si consideramos el empuje pasivo Ep para aumentar la fuerza estabilizadora construyendo un
diente de C
Ep = 4.54 Tn/m
FS = M estabiliz = 2.01 >1.5 CONFORME
VERIFICACION DE ESTABILIDAD
VERIFICACION DE MUROS DE CONTENCIN - TIPO 01
CHEQUEO AL VOLTEO
VERIFICACION DE MUROS DE CONTENCIN - TIPO 01
M volteo
FS = u*Fv +Ep 2.38 >1.50 CONFORME
Fh
X = ( Mr - Ma ) 0.60
P
e = B/2 - X 0.30
B/6 > e = 0.30 >e CONFORME
q1 = 9.89 tn/m2 CONFORME
q2 = 0.02 tn/m2 CONFORME
q